ETAPisthemost
comprehensiveelectricalengineering
softwaresolutionforthedesign,simulation,
operation,andautomationofgeneration,
transmission,distribution,andindustrialpower
systems.
ETAPisdevelopedunderanestablishedquality
assuranceprogramandisusedworldwideas
ahighimpactsoftware.ETAPiscompletely
localizedinsixlanguageswithtranslatedoutput
reportsinsevenlanguages.
Asafullyintegratedenterprisesolution,ETAP
extendstoaReal-TimePowerManagement
Systemtomonitor,control,automate,simulate,
andoptimizetheoperationofpowersystems.
ProductOverview
Enterprise Software Solutionfor Electrical Power Systems
Network AnalysisShort Circuit - ANSI / IEEE•ANSI/IEEEC37Standards•IEEE141&399Standards•UL®489Standard•Integrateswithprotectivedevicecoordination•Automaticdeviceevaluationfor3-phase,1-phase,&panelsystems
•GeneratorCBevaluation•Phase-shiftingtransformer•Loadterminalshortcircuitcalculation
Short Circuit - IEC•IEC60909,60282,60781,&60947Standards•Transientfaultanalysis-IEC61363Standard•Integrateswithprotectivedevicecoordination•Automaticdeviceevaluationfor3-phase,1-phase,&panelsystems
•User-definablevoltagecfactor•Loadterminalshortcircuitcalculation
Load Flow•Powerflow•Demandload•Voltagedrop•Powerfactorcorrection•Automaticdeviceevaluation•Automatictemperaturecorrection•2W&3WtransformerLTC/regulatoractions•Real&reactivepowerlosses•Extensiveviolationalerts•Multi-reportResultAnalyzer•Auto-Runloadflowbasedonsystemchanges•AdaptiveNewton-Raphsonmethod•Fastconvergenceforsystemswithnegligibleimpedance
•Handlingoftransmissionseriescompensation
Motor Acceleration•Dynamicmotoracceleration•Voltageflicker•Motor&loaddynamicmodels•Staticmotorstarting•Multi-sequencestarting•Conventionalstartingdevices•Softstarterdevices•VFDfrequencycontrolmotorstarting•Load&generationtransitioning•MotorOperatedValve(MOV)simulation•Comprehensivealarm&warning•Startmotorindividuallyorbasedongroups
Modular
Arc FlashAC Arc Flash•IEEE15842002&2004Standards•NFPA®70E2000,2004,&2009Standards•CSAZ4622008Standard•ASTMD120-02aStandard•OSHA29CFR1910Standard•NationalElectricCode®(NEC)110.6•NationalElectricSafetyCode®(NESC)•Embeddedshortcircuit&devicecoordination•3&1-PhaseArcFlashSequence-of-Operation•Graphicaldisplayofdevicetripsequence•Automaticverificationofdeviceduty•User-definedincidentenergycorrectionfactor•CurrentLimitingFuse(CLF)modeling•IncidentEnergyplots•LVtransformerarcflashlimit•Maintenancemodeswitch•Relayactions(49,50,51,67,79,87)•Panels&single-phasesystems•Multi-reportResultAnalyzer•Labels,workpermits,&datasheets
DC Arc Flash•MaximumPowerMethod•Stokes&OppenlanderMethod•PaukertMethod•Determineincidentenergy•Assessarcflashprotectionboundary•ArcFlashViewer•Multi-reportResultAnalyzer•Labelsandworkpermits
Panel SystemsPanel ANSI & IEC•Intelligentpaneldesign&analysis•3-phase(3&4Wire)panels•1-phase(2&3Wire)panels•1-phase(A,B,C,AB,BC,CA,&3Wire)panels•ANSI&IECStandards•NationalElectricCodeloadfactors•Loadflowwithgraphicalperphasedisplay•Automaticdevicedutyevaluation&alerts•Automaticupdatingofupstreampanels•ExportpanelschedulestoMicrosoftExcel•Panelwithinternal&externalfeeders&loads
Protective DevicesCoordination & Selectivity•AC&DCcoordination•Graphicallyadjustabledevicesettings•Extensivedevicelibrary(verified&validated)•Embeddedshortcircuitanalysis•Embeddedmotoraccelerationanalysis•Multi-axistimecurrentcurves•Comprehensiveplotoptions•Adjustablemagnifying-glasszoomview•Timedifferencecalculator•Multi-function/levelrelays•Devicesettingreports•Automaticdetectionofprotectionzones•Protection&coordinationzoneviewer
Sequence-of-Operation•Viewdeviceoperationsequencegraphically•Devicefailure&backupoperation•Sequenceviewer•Normalized(shifted)curves•Currentsummation•Relayactions(27,49,50,51,51V,59,67,79,87)
Relay Test Set Interface•Interfaceswithtesting&maintenancedatabase•Exportshortcircuit&protectiverelaysettings•Plotdevicesteady-stateresponse•ComparerelayresponsewithOEMdata•Displayrelayactualtransientresponse•Analyzerelayfalsetrips&mis-operation•ExporttoCOMTRADEformat
User-Defined Dynamic Model•Fullgraphicalmodelbuilder•Libraryofpre-builtmodels•Integratedwithtransientstabilitymodels•Widevarietyofblocksforbuildingmodels•Import&ExportSimulink®models•Variousmodeltestingmethods•Real-timecompiling&linkingofmodel•AutomaticUDMlinkstocomponents•Compile&testdirectlyfromtheUDMbuilder
Intuitive
Cable SizingAmpacity & Sizing•IEEE399Standard•NFPA70-NationalElectricCode•ICEAP54Standard•IEC60364-5-52,60364-4-43Standards•BS7671Standard•Ampacity/CurrentCarryingCapacityCalculator•Sizingbasedonampacity,voltagedrop,shortcircuit,harmonics,&overloadprotection
•Maximumoraverageoperatingcurrent•Armor&Sheaththermalcalculation•GroundingconductorselectionbasedonNEC•CableLibrarywithneutral,grounding/protectiveearthing(PE)conductor
•Addauxiliaryneutral&PEconductors•Optimal&alternativesizes•ModelForms:BS&user-definable•ReportsinCrystalReports&Excel
Protective Earthing (PE) Conductor Sizing•IEC60364-5-54Standard•BS7671Standard•PEthermalrequirements&sizing•User-definedfaultcurrent&clearingtime•ReportsinCrystalReports&Excel•Considerleakagecurrent
Electric Shock Protection•IEC60364-4-41Standard•BS7671Standard•EN50122Standard•TN-C,TN-S,TN-C-S,TT,&ITEarthingtypes•Electricshockrequirements•Loopimpedance¤tcalculation•Touchvoltagecalculation&evaluation•ConsiderresistancetoGround/Earth•GFCI/RCCBprotection•ReportsinCrystalReports&Excel
Parameter Estimation•Estimateinductionmachineequivalentcircuitparametersbasedonreadilyavailablemanufacturerdata
•Single-cagemodels•Rotordeep-bareffects
Renewable EnergyWind Turbine Generator•Modelunlimitedwindturbinegenerators•Detailedmodelingofturbinedynamics,aerodynamics,&powercoefficients
•DFIGwithpitch&convertercontroller•Simulatewinddisturbancelikeramp&gust•Individualorzone-baseddisturbances•WECCwindturbinemodels•WTGmanufacturer/modellibrary
Photovoltaic Array•Solarfarmmodeling•Solarirradiancebasedonlocation&time•Performanceadjustmentcoefficients•AC&DCSystemAnalysis•Inverterdynamicmodeling&operationmodes•MaximumPeakPowerTracking(MPPT)•Constantcurrentsourcemodeling•ModelPVsystemswithindividualpanels•ModelDCcables&combinerboxes•ExtensiveManufacturer/Modellibrary•P-V&I-Vcurves
Cable SystemsUnderground Thermal Analysis•Neher-McGrathMethod•IEC60287Standard•Steady-statetemperature•Ampacityoptimization•Automaticcablesizing•Transienttemperature•Intelligentrule-basedalignment&spacingtools•Automaticconduitdistribution&spacing•Uniform&non-uniformconduitarrangements•Custom,NEC,orIEEErule-basedspacing•Wizardforcreatingraceways
Cable Pulling•Integratedwithone-linediagramcables•Integratedwithundergroundracewayscables•Pullmultiplecables•Completelyflexiblepullgeometry•FullETAPcablelibraryintegration•Display3-Dpullingpathgeometry
Dynamics & TransientsTransient Stability•Completesynchronous&inductionmachinemodels•Comprehensiveexcitationsystemmodels•Comprehensivegovernor-turbinemodels•PowerSystemStabilizer(PSS)models•GE,Westinghouse,&Solargasturbines•User-definedDynamicModels(UDM)•Unlimitedsequenceofevents&actions•Typical&commondisturbances&operations•Automaticactionsbasedonrelaysettings•Short-time&long-timesimulation•Variabletotalsimulationtime&simulationstep•3-phase&line-to-groundfaultactions•Auto-synccheckaction•EmbeddedNewton-Raphsoninitialloadflow•VFD/VSDdynamicmodeling•LumpedLoaduser-defineddynamicmodeling•UPSparalleloperationmodeling•PVArraysourcemodeling•Invertersourcemodeling
Generator Start-Up•Cold-stategeneratorstarting•Loadgeneratorspriortosynchronousspeed•Frequency-dependentmachinemodels•Frequency-dependentnetworkmodels•AnexpansiontotheTransientStabilitymodule•User-defineddynamicmodelinterface
TransformerMVA Sizing•Sizingbasedonconnectedoroperatingload•ANSI&IECstandardtypes,classes,&ratings•Considersambienttemperature,altitude,loadgrowth,&loadfactors
•MVASizingbasedoncoolingstages
Tap Optimization•ANSI/IEEEC57.116Standard•Optimizeunittransformerturnsratio•Considerssystemvoltagevariation•Considersgenerationstationauxiliaryload•Generatorreactivecapacityvs.voltageplots
Integrated
Power QualityHarmonic Load Flow•IEEE519Standard•Harmonicsspectrumupto250thorder•Automaticdistortionevaluation(THD&IHD)•Telephoneinfluencefactors(TIF&I*T)•Calculate&reportI*TB(Balanced)&I*TR(Residual)
•VFDharmonicmodeling•UPSACinput&outputmodelingforharmonicorders
•PVArraymodelingforharmonicorders•Automaticalertsofviolations•Harmonicsourceslibrary•EmbeddedAdaptiveNewton-RaphsonMethod•EmbeddedAcceleratedGauss-SeidelMethod
Interharmonics•Interharmonicmodeling&simulation•Performvoltageflickerlimitationstudies•InterharmonicdistortionindicescalculationbasedonIEC61000-4-7
•Adjustableharmoniccurrentbase•Automaticharmonicspectrumgeneration•Automaticinterharmonicfrequencygeneration
Frequency Scan•User-definablefrequencyrange•Resonanceconditionidentification&alerting•User-customizableplots
Harmonic Filters•Filterdesign&sizing•Single-tuned,high-pass,&band-passfilters•Automaticfilteroverloadingalert•Interharmonicfiltermodeling
Control SystemsDC Control Systems Diagram•Simulationofoperationsequence•Pickup&dropoutvoltagecalculation•Automaticalerts•Burden&inrushmodes•Controlledcontacts•Integratedwithbatterydischargecalculation•Integratedwithone-linediagram•Stateenginewithautomatic&step-by-stepsequence-of-operationofcontrolrelays,switchingactions,etc.
DataX PlusMicrosoft® Excel Interface•Bi-directionalExceldataexchange(Open&FixedFormats)
•MapExcelworksheetstoETAPelements•SynchronizedatatoETAPprojects•Performconsistencychecksduringdataexchange
•SubstitutemissinginformationwithETAPdefaults&librarydata
Project Merge•ParallelETAPprojectdevelopment•MergeBase&RevisionData•MergeTCCsViews•Multi-usermanagementofprojectmerge
SmartPlant® Electrical Interface•Bi-directionaldataexchange•MapattributesofSPELwithETAPelements•Databasemappingviagraphicuserinterface
e-DPP® Interface•Mapattributesofe-DPPtoETAPelements•Synchronizee-DPPdatatoETAPprojects•Databasemappingviagraphicuserinterface
DC SystemsLoad Flow •IEEE946Standard•IntegratedAC&DCsystems•EmbeddedNewton-RaphsonMethod•Voltagedrop•Powerlosses•Batteryauto-activation•Charger/UPScurrentlimit•Charger/UPSmodeauto-switching•DCconvertermodeling•Motormodelauto-switching
Short Circuit•IEEE946Standard•IntegratedAC&DCsystems•Totalbus&branchcontributionfaultcurrents•Faultcurrentrisingtime•BatterymodelingperANSI/IECStandard•ChargermodelingperANSI/IECStandard
Battery Discharge & Sizing•IEEE308,485,&946Standards•IntegratedAC,DC,&ControlSystemDiagram•Batterydischargesimulation•Batterysizing•DischargeviaDCloadflowordutycyclesummation
•Voltagedrop&lossconsideration•Class1EDCpower&controlsystemmodels•Simulationofcontrolsystemwithbatterydischargevoltage
•Dutycyclediversityfactor•Loadmodeltypeperoperatingcharacteristics•Batterydutycyclecalculatedfromindividualloads
•Optionsforbattery&loaddutycycle1minutespan
•Multipleuserselectedoptionsforbatterycharacteristicinterpolation
•Multiplediversity&correctionfactors•BatterysizingreportinIEEE485Standardformat
•Plotbatterycapacity,voltage,¤t•Plotbusvoltage&load&branchflow•Detailedbatterylibrary
Distribution SystemsUnbalanced Load Flow•Unbalancedpowerflow•Single-phase&unbalanced3-phasemodeling•Unbalanced&nonlinearloadmodeling•Open-deltatransformermodeling•Center-taptransformermodeling•Three1-phasetransformermodeling•Isolatedsub-systemswithvoltage-controlsourcemodeling
•Isolated1-phasesource&systemmodeling•Seriesfaultoropenphaseconditionmodeling•Phase&sequencevoltage,current,&power•Voltage¤tunbalancefactors•Transmissionlinecoupling•Automaticdeviceevaluation•Reportvoltage&powerinmulti-units
Optimal Power Flow•Solvemultipleobjectivessimultaneously•Interiorpointmethodwithbarrierfunctions•Minimizepowerlosses•Activepoweroptimization•Reactivepoweroptimization•Optimaldispatch
Optimal Capacitor Placement•Optimallocation&banksize•Minimizeinstallation&operationcosts•Individualsourceoraverageenergycost•Voltage&powerfactorobjectives•Minimum,maximum,&averageloading•Branchcapacityrelease&costsavings•Reviewcapacitorimpactonthesystem•Capacitorcontrolmethod•Flexibleconstraints
Reliability Assessment•Systemreliability•Customerorientedindices•Energy(cost)indices•Sensitivityanalysis•Single&doublecontingency
Single-Phase Distribution•ANSI&IECStandards•Loadflowwithgraphicalperphasedisplay•Voltagedrop&powerlosses•Voltage¤tunbalancefactors•Automaticdevicedutyevaluation&alerts
Geographic Information System
GIS Map•ViewGISmapsinETAP•DisplayanalysisresultsonGISmaps•SynchronizeGISdatatoETAPprojects•Usegraphicaluserinterfacefordatamapping•Controlmodification&accept/rejectactions•Checkconsistencyfordatasynchronization•UtilizeGISmaptools•GIShandlingof1-phasesystems
Ground Grid SystemsFinite Element Method•3-Dplotsforstep,touch,&absolutepotentials•3-Dirregularconfigurations•3-Dgraphicalinterfaceviews•Rods&conductorsinanydirection•Graphicaldisplayofoverlimits
IEEE 80 & 665 Standards•Conductor&rodoptimization•3-Dgraphicalinterfaceviews
Transmission LineLine Constants•Conductor&groundwirelibraries•Built-inconfigurations:horizontal,vertical,etc.•Generalconfiguration:X,Y,&Zcoordinates•Multi-linemutualcoupling•Phase&sequenceimpedancematrix•Transposed&un-transposedlines•Short&longlinemodels•Multiplelayersoilmodel•Calculatedoruser-definedimpedances
Line Ampacity•Conductorampacityvs.temperature•IEEE738Standard•Determinemaximumoperatingtemperatureforvariousloadingconditions
•Deratedampacitybasedontemperaturelimit•Considerweather,solarheat,&geographicallocation
Sag & Tension •Sag/tensionvs.temperature•Multiplespansbetweendead-endstructures•Levelspansofunequallength•Solvespansofunequallengthondifferenthorizontalplanes
•Includeeffectsofwind,temperature,&kfactor
HVDC Transmission Link•Detailedrectifier&convertermodeling•CompositeAC/DC&DC/ACsystems•Built-incontrolschemes•Inclusivetransformermodel•Automaticharmonicspectrumcalculation•Easy-to-useintegratedmodel
Comprehensive
ISO 9001:200810 CFR 50 Appendix B 10 CFR 21ANSI/ASME N45.2ASME NQA-1ANSI / IEEE 730.1CAN / CSA-Q396.1.2ANSI N45.22
ETAP Quality AssuranceETAP's quality assurance is specifically dedicated to meeting the requirements of:
ETAPisVerifiedandValidated(V&V)againstfieldresults,realsystemmeasurements,establishedprograms,andhandcalculationsinordertoensureitstechnicalaccuracy.EachreleaseofETAPundergoesacompleteV&Vprocessusingthousandsoftestcasesforeachandeverycalculationmoduleandlibrarydata.
ETAP is a high impact software qualified for use within nuclear, military and mission critical facilities and operations.
Certificate Registration #10002889 QM08
Base PackageBase Package
ETAPBasePackageisasetofcoretools,embeddedanalysismodules,andengineeringlibrariesthatallowyoutocreate,configure,customize,andmanageyoursystemmodel.Coretoolsallowyoutoquicklyandeasilybuild3-phaseand1-phaseACandDCnetworkone-linediagramswithunlimitedbusesandelementsincludingdetailedinstrumentationandgroundingcomponents.Engineeringlibrariesprovidecompleteverifiedandvalidateddatabasedonequipmentmanufacturers'publisheddata.
Cable Manager•Batchcablemanagement•Customizablecablereports•Multi-cablesizing&shockprotectionevaluation•Intelligentsearch/filtering
Data Manager •View/editBase&RevisionData•Viewequipmentpropertiesforindividualfields•Viewequipmentstate&Service•Viewabsolutevalueordifferences•Display&filterdatabasedonstudytype•Graphicaldatamanagement&mergeperindividualequipment
Theme Manager•Displaycolorcodingbasedon:-Standard -Voltagelevel-Area-Grounding(Solid,Low-Z,High-Z,Ungrounded)-Earthing(TT,TN,IT,NEC)
•Displayfaultedbusesbysymbolorcolor
Multi-Dimensional Database•Orthogonalmulti-dimensiondatabase•Unlimitedindependentgraphicalviews•Unlimitedstatusconfigurations•Unlimitedpropertyrevisions•Multipleloading&generationconditions•Lock&unlockelementproperties•10Statestotrackequipmentconditions•Utilizereal-timeoperatingdata•Unlimitedstudysolutions•ODBC–MSAccess,SQLServerconnectivity•Dumpsterwithunlimitedcells:copy&paste•Useraccesssecuritywithpasswordprotection•Edited-by&checked-bywithdatestamping•Mergeprojectfilesviaclipboard
Embedded Analysis Modules
One-Line Diagram•Built-inintelligentgraphics•Automaticequipmentconnectionmode•Networknesting•Integrated1-phase,3-phase,&DCsystems•IntegratedAC,DC,&groundingsystems•Multiplegenerators&gridconnections•Displayresultsonone-linediagrams•Customizablefonttypes,styles,&colors•Customizabledisplayofratings&results•Graphicaldisplayofequipmentgrounding•Graphicaldisplayofoverstresseddevices&alerts
•Hide&showprotectivedevices&groundingelements
•Thememanager•One-linetemplates•Propagationofnominal&ratedvoltage•Propagationofphaseconnection•Automaticdisplayofenergized&de-energizedelementsusingdynamiccontinuitycheck
•Textboxeditorwithdynamiclinktoproperties•OLEobject&ActiveXcontrolintegration•Intelligenttextbox&hyperlinkbookmarks•CustomizableoutputreportsviaCrystalReports
•Batchprintingwithview-dependentprintersettings
•User-friendlyplotting•Keywordbasedelementsearch
One-Line Diagram Templates•Create&utilizeunlimitedone-linetemplates•SharetemplatescreatedbyotherETAPengineers
•UsedefaultprojectIDortemplateID•Usepropertiesfromthedefaultprojectortemplates
•Instantpreviewoftemplates
System Elements•UnlimitedAC&DCelements•1-phase(2&3Wire),2-phase(2&3Wire),3-phase(3&4Wire)
•Unlimitedbuses:licensedependentatrun-time•Nestedviews(compositenetworks&MCC)•Powergrid•Synchronous&inductiongenerators•Photovoltaicarray(PVInterconnectionStudy)•DCPhotovoltaicarray•WindTurbineGenerator•MOV,synchronous,&inductionmotors•Exciters,governors,&stabilizers•Voltage&frequencydependentlumpedload•Cable,line,reactor,&impedancebranches•2W&3Wtransformerswithvoltageregulators•2W&3Wtransformerswithburieddeltawinding•Open-Deltatransformer•Remoteconnectors•Harmonicfilter•StaticVarCompensator•Instrumenttransformers(CT&VT)•Protectivedevices&meters•Single&doublethrowswitches•Groundingswitch•Busduct•Batteries,DCmotors,DCloads&branches•Chargers•Inverters•UPS•DCconverter•VariableFrequency/SpeedDrive(VFD/VSD)•ANSI,IEC,&user-definedsymbols
Switching Device Interlock Enforcer•Autoenforcementofswitchinginterlocklogics•Automatic‘pre’&‘post’switchinglogicverification•Interlockbasedoncircuitbreakerpositionsormeterreadings
•Automaticinterlockconflictchecking•Abilitytomodelcascadeswitchingcontrol•Activemonitoringofswitchinginterlockviolations•Switchingplanvalidation
Configuration Manager•Tabulate&controldifferentstatusconfigurations•Comparesource,load,&switchingdevicestatus•Flagchangeddatawithcheckercapability•Copy,merge,export,import,&print
• Cable Constants
• Transmission Line Constants
• Cable Ampacity
• Cable Sizing
• Cable Manager
Network Simulation•Unlimitedbuses(licensedependent)&elements•Looped&radialsystems•Automaticerrorchecking•Userinterfaceforallnetworkanalysismodules•CustomizableETAPpreferenceproperties•Multi-leveluseraccessmanagement
Built-In Calculators•MVA,MW,Mvar,kV,Amp,&PFconversion•Motornameplate&dynamicparameterdata•Generationnameplate•Powergridshortcircuitimpedances•Motor&generationinertia
Output Report Comparator•Built-inoutputreportcomparisontool•Comparehundredsofstudyreportsinoneaction•Verifystudyresultsagainstbenchmarkreports
Project Management•Managestudieswithscenarios¯os•Recordscenariosbasedonstudysettings•Macro-controlledscenarioexecution
Data Exchange (DataX) Base•LegacyprogramconversiontoETAP•Automaticone-linecreation•Protectivedevicelibrarymapping•Convertusingnativefileformats•Built-inconversionsforSKM®Dapper®&Captor™,PSS®E,EasyPower®&others
•WMF/EMF/DXF/PDFexporting•ImportRAW/IEEE/CSVfiles•ExporttoAutoCAD®usingDXFformat•ImportgroundgridplansfromAutoCAD•LoadTicketforinductionmachines
Download a Free Demo at etap.com
Base PackageBase Package
BasePackageincludesanintelligentone-linediagram,elementeditors,verifiedandvalidatedengineeringdevicelibraries,configurationmanager,reportmanager,projectandstudywizards,multi-dimensionaldatabase,thememanager,dataexchange,anduseraccessmanagement.Embeddedanalysismodules,suchasCableAmpacity,CableSizing,andTransmissionLineConstants,provideintegratedaswellasstand-alonecapabilitiestodesign,analyze,andsizeequipment.
Libraries•Comprehensivelibrary(over100,000devices)•ANSI&IECdeviceslibraries•Verified&Validated(V&V)librarydata•V&Vlockeddata•Add,copy,merge,&deletecapabilities•User-defined&controlledlibraries•User-accesscontrol&security•Edited-by&checked-bywithdatestamping•User-controlledlibrarymerge
Report Manager•Customizableoutputreports&plots•Input,results,alerts,&summaryreports•ReportsviaCrystalReportsviewer•PDF,Microsoft®Word,Access,&Excelreports•ElementID&textsearchcapability•Multi-languageReport
License Manager•Stand-Alone•ConcurrentUserLAN&WAN•Networklicensecheckout•Licenseborrowingmanager•Flexiblelicenseborrowingduration•LicenseManagerconfigurationwizardutility
Multiple Language Support•Interface&HelpFileinsixlanguages•Outputreportsinsevenlanguages
Cable
CableFireCoatingProtection
CableFireStopProtection
CableFireWrapProtection
TransmissionLine
LineGroundConductor
MotorNameplate
MotorCKTModel
MotorCharacteristicModel
MotorLoadModel
WindTurbineGenerator
PhotovoltaicPanel
SolarPanel
Fuse
RecloserHydraulic
RecloserElectronicController
HVCircuitBreaker
LVCircuitBreaker
SolidStateTrip
ThermalMagnetic
Electro-Magnetic
MotorCircuitProtector
OverloadHeater
Harmonic
InterruptionCost
Reliability
Battery
ControlContact
ControlRelay
ControlSolenoid
GFI/RCD
Libraries
English
Chinese
Japanese
Russian
Spanish
Portuguese
German
OutputReportsInEveryRelease
LocalizedRelease
Intelligent Load Shedding
Load Preservation•Steady-state&transientresponse•Optimalloadpreservation•Fastresponsetime•Reliableoperation•Minimumloadshedding•Proactivecontingencyanalysis•Systemislandinglogic•VFDloadreductioncontrol
System Restoration•Restartinhibition•Logicalloadsequencer•Load/sourcerestorationpriority
Load Shedding Validation•Automaticgenerationoftransientstudycases
•Confirmloadsheddingactions•SimulateILSrecommendation•Integratedstabilityknowledgebase
IntelligentSubstation
Substation Automation•Flexibleautomation•Programmablelogiceditor•Onlinecontrol•Remotecontrol-enable&disablecommands
•Controlinhibitionbasedonsystemoperationalconstraints
Switching Management•Switchingsequencemanagement
•Safety&securityprocedures•Interlocklogicevaluator•Switchingplanvalidation•Controlinhibitionbasedonswitchingoperations
•Safetygroundswitch•Pre-switch&post-actioninterlock•Enforcedinterlocklogicinsimulationmode
•IntegratedoperationwithSwitchingManagementSystem
•Supervisorycontrolforreal-timeswitchingoperation
Load Management•Demand-sidemanagement•Time-of-useloadshifting•Intelligentloadmanagement
Energy ManagementSystem
Automatic Generation Control•Multi-areacontrol•Loadfrequencycontrol•MW&MVARsharing•NERCperformancestandard
Economic Dispatch•Minimizefuelcosts•Optimizeenergycosts•Fastsolution•Robustalgorithms
Supervisory Control•Systemoptimization•Supervisory&advisorycontrolsystem
•Optimalpowerflow•Programmablelogiceditor
Interchange Scheduling•Tariffanalyzer•Ratestructurebuilder•Transactionscheduling•Transactioncontract•Transactionreports•Fuelcostschedulereports
Reserve Management•Operatingreserveanalysis•Reservecapacitymonitoring•Notificationofinadequatereserve•Predictoperatingreserve
Information Storage & Retrieval•SQLServer-baseddataarchiving•Energy,power&non-electricaldatatracking
•Automaticdatahandling•ExporttoMSExcel•CustomizableReports
Monitoring & Predictive Simulation
Advanced Monitoring•NetworkTopologyBuilder&Processor•Intelligentgraphicaluserinterface•Stateestimator&loaddistributor•Process&performancemonitoring•Alarm¬ificationmanagement•Generationreservemonitoring•Multi-statebreakermonitoring&control•Thinclientbasedmonitoring&control•HumanMachineInterface(HMI)templatelibrary
•Web-basedcustomizableHMI
Energy Accounting•Energytariffbuilder•Customizablereports•Real-timeenergycosttracker•Cost&consumptionsummary
Real-Time Simulation•Simulatecircuitbreakeroperation•Identifypotentialoperatingproblems•Simulatemotorstarting&loadchange•Predictoperatingtimeofprotectivedevices
•Predictsystemresponsebasedonoperatoractions
•Perform“WhatIf”operatingscenarios•Web-basedsimulation&alerts•Simulatereal-time&archiveddata•Operatorassistance&training
Event Playback•Replayarchivedhistoriandata•Investigatecause&effect•Explorealternativeactions•Replay“WhatIf”scenarios•Playbackofeventviews•Historicalalarmdatabase
Load Forecasting•Adaptivebusloadforecasting•Real-timetrending•Loadprofilelibrary•Forecastingscenarioarchiving
(800) 477-ETAP • (949) 900-1000
ETAP Real-TimeETAP Real-Time
• Power Management System• Energy Management System• Generation Management System• Distribution Mangement System• Intelligent Load Shedding• Smart Grid & Microgrid Solutions
Real-Time Solutions
B8-1013
© 2012 ETAP / Operation Technology, Inc. All rights reserved. Certain names and/or logos used in this document may constitute trademarks, service marks, or trade names of Operation Technology, Inc. Other brand and product names are trademarks of their respective holders.