Product Catalog
www.hinkleymetalproducts.com
PAGE 2
CONTENTSPRODUCT PAGE NUMBER
VENTS & FLANGES.....................................................................Tall Cone Roof Vent...................................................................... Wind Band Cap.............................................................................. Short Cone Roof Vent....................................................................Texas Cap......................................................................................Storm Collar....................................................................................Replacement Flange........................................................................Gable Louver End Vent.....................................................................K-9 Louver.........................................................................................Slant Back Roof Vent.............................................................................FLASHING.........................................................................................Apron...............................................................................................Style D Gable & Eave Drip...............................................................Roof Edge Cap...................................................................................Valley..............................................................................................Wall.................................................................................................Water Stop Valley.............................................................................Water Return Nailing Clip.............................................................................Counter...................................................................................................Water Diverter...................................................................................................Termite Shield...................................................................................................Z-Flashing...................................................................................................Gravel Guard...................................................................................................Angle...................................................................................................Step Wall...................................................................................................Window...................................................................................................Step Counter...................................................................................................CHIMNEY...................................................................................................Chimney Pan w/Top.............................................................................Chimney Pan...................................................................................................Chimney Pan w/Top & Screen.............................................................................Standing Seam Chimney Top.............................................................................Chimney Cricket...................................................................................................MISCELLANEOUS.............................................................................Water Heater A/C Pan.............................................................................Header(conducter heads).................................................................Chimney Cricket.............................................................................Scupper................................................................................Wall Shield.............................................................................Square to Round Transition ...............................................................................CONTACT INFORMATION..............................................................................
345678910111213141516171819202122232425262728293031323334353637383940414243
PAGE 3
VENTS and FLANGES
Tall Cone Roof VentWind Band CapShort Cone Roof VentTexas CapStorm CollarReplacement FlangeGable Louver End VentK-9 LouverSlant Back Roof Vent
PAGE 4
TALL CONE
ROOF FLANGE/ROOF JACKDesigned to flange over gas water heater and central heat vent pipes.
TOP OPENING SIZE: STANDARD ROOF PITCH:
3” FLAT THRU 6/12
4” FLAT THRU 6/125” FLAT THRU 6/126” FLAT THRU 6/12
All other size top opening and roof pitch will be special order
STANDARD MATERIAL:Mill Finished Galvanized
SPECIAL ORDER MATERIAL:Painted Galvanized, Mill Finished Aluminum
Painted Aluminum, Copper
MECHANICALLY JOINED, DOUBLELOCKED, SEAMED,SEALED ANDPOWER PRESSED
DOUBLE LOCKSEAM DOWN SLOPE
OPTION: 1/2” HEM EDGEWATER RETURN 1/2”
SIZE OF OPENING TOACCOMMODATE MOSTDOUBLE WALL PIPES
PAGE 5
WIND BAND CAPUsed with Tall and Short Cone Combination.
SIZE
3”
4”
5”
6”
STANDARD MATERIAL:Mill Finished 26 Ga. Galvanized
SPECIAL ORDER MATERIALS:Painted Galvanized, Mill Finished Aluminum
Painted Aluminum, Copper
(Other Sizes Are Available Upon Request)
PAGE 6
SHORT CONE ROOF FLANGE
ROOF JACKThis flange is, designed to be, used with a storm collar and vent cap. Thedouble wall vent pipe extends through the flange and storm collar. The
storm collar skirts over the roof flange. The vent cap is secured directly ontothe top of the double wall vent pipe.
TOP OPENING SIZE: STANDARD ROOF PITCH:
3” FLAT THRU 6/12
4” FLAT THRU 6/125” FLAT THRU 6/126” FLAT THRU 6/12
All other size top opening and roof pitch will be special order
STANDARD MATERIAL:Mill Finished Galvanized
SPECIAL ORDER MATERIAL:Painted Galvanized, Mill Finished Aluminum
Painted Aluminum, Copper
MECHANICALLY JOINED, DOUBLELOCKED, SEAMED,SEALED ANDPOWER PRESSED
DOUBLE LOCK SEAMDOWN SLOPE SIZE OF OPENING TO
ACCOMMODATE MOSTDOUBLE WALL PIPES
VENTCAP
STORMCOLLAR
ROOFFLANGE
OPTION: 1/2” HEM EDGEWATER RETURN 1/2”
PAGE 7
TEXAS VENT CAPUsed with Tall and Short Cone Combination.
SIZE
3”
4”
5”
6”
STANDARD MATERIAL:Mill Finished 26 Ga. Galvanized
SPECIAL ORDER MATERIALS:Painted Galvanized
Mill Finished AluminumPainted Aluminum
Copper
(Other Sizes Are Available Upon Request)
PAGE 8
STORM COLLAR
PAGE 9
REPLACEMENT FLANGE
w/CAP
Used to replace lead or neoprene flashing. Flashings are handcrafted to fit the exact roof pitch. All seams are soldered
STANDARD MATERIAL:Mill Finished Galvanized
Copper
(When Ordering Specify Exact Roof Pitch)
FITS OVERSTANDARD PIPES
STANDARD ROOFPITCH:
1” 0/12 THRU 12/12
2” 0/12 THRU 12/12
3” 0/12 THRU 12/12
4” 0/12 THRU 12/12
PAGE 10
GABLE LOUVER
Gable louvers are designed to allow the attic to breathe.Venting helps to eliminate moisture and excessive heat.
LOUVER SIZEWHEN ORDERING SPECIFY:
Type Of MaterialRoof pitch or degreeMeasurement of A, B, C
STANDARD MATERIAL:Mill Finished 26 Gauge Galvanized
SPECIAL ORDER MATERIALS:Copper
Stainless Steel
(Other Sizes Are Available Upon Request)
C
BA
PAGE 11
K-9 LOUVER
Roof top louvers are designed to allow the attic to breathe.Venting helps to eliminate moisture and excessive heat.
LOUVER SIZEWHEN ORDERING SPECIFY:
Type Of MaterialRoof pitch or degree
Measurement of A, B, C, & D
STANDARD MATERIAL:Mill Finished 26 Gauge Galvanized
SPECIAL ORDER MATERIALS:Copper
Stainless Steel
(Other Sizes Are Available Upon Request)
D
C
BA
PAGE 12
SLANT BACK ROOF VENTThe Slant Back Roof Vent is recommended for duct outlet inkitchen and bathroom exhaust fans. The Slant Back Vent is
also used as an attic static vent.
STANDARD MATERIAL:Mill Finished 26 Ga. Galvanized
SPECIAL ORDER MATERIALS:Mill Finished Aluminum
Painted AluminumCopper
(Other Sizes Are Available Upon Request)
OPTION 1/2” HEMEDGE WATERRETURN
THE COLLAR IS MECHANICALLY JOINED, DOUBLE LOCKED, SEAMED, SEALED AND POWERPRESSED THE COLLAR OPENING SIZE IS 9 5/8”, AN INSECT SCREEN IS ATTACHED TO THE TOPOF THE COLLAR
PAGE 13
FLASHING
ApronStyle D Gable & Eave DripRoof Edge CapValleyWallWater Stop ValleyWater Return Nailing ClipCounter
Water DiverterTermite ShieldZ-FlashingGravel GuardAngleStep WallWindowStep Counter
PAGE 14
APRONThe standard apron flashing is normally installed where a horizontalroof meets and slants down and away from a vertical wall. The backside of the flashing is installed behind siding or brick counter flashing.
The front apron is installed over the shingles.
STANDARD SIZE 9”W X 120”LA. 3 1/2”B. 5”C. 1/2” Kick
STANDARD MATERIAL:Mill Finished 26 Ga. Galvanized
SPECIAL ORDER MATERIALS:Painted Galvanized, Mill Finished Aluminum
Painted Aluminum, Copper
(Other Sizes Are Available Upon Request)
BACK
FRONT
CKICK
A
B
PAGE 15
B
A
D &E
C
STYLE “D”
GABLE & EAVE DRIP EDGEGable and Eave flashing are normally used to cap or flash the jointbetween the gable and eave edge of the roof sheathing and the topof the fascia. Edge trim also adds support to the shingles when theyare extended over the roof’s edge. The kick at the bottom of the face
diverts rainwater from the fascia board.
STANDARD SIZES:
FACESIZE
METAL CUT SIZE A B CD
KICKE
HEM
1” 5” 1 1/4” 5/8” 3” 3/8” 1/8”
1 1/4” 5” 1 1/2” 5/8” 2 2/3” 3/8” 1/8”1 1/2” 5” 1 3/4” 5/8” 2 1/2” 3/8” 1/8”
STANDARD MATERIAL:Mill Finish AluminumMill Finish Galvanized
White, Ivory, Brown and Gray Aluminum
SPECIAL ORDER MATERIALS:Other Colors Aluminum, Painted Galvanized, Copper
(Other Sizes Are Available Upon Request)
PAGE 16
ROOF EDGE CAP
FLASHINGRoof edge cap flashing is used to cap or flash the joint between the
roof sheathing and the top of the fascia. The kick at the bottom of theface is designed to allow water run off to drip free of the fascia board
and underlying construction.
STANDARD SIZES:
FACE SIZE METAL CUT SIZE A B C1” 4” 3 3/4 1/4
1 1/2” 5” 3 1/2 1 1/22” 5” 3 1 1/2 1/23” 6” 3 2 1/2_ 1/2
STANDARD MATERIAL:Mill Finished GalvanizedMill Finished Aluminum
SPECIAL ORDER MATERIALS:Painted Galvanized, Painted Aluminum, Copper
(Other Sizes Are Available Upon Request)
C
B
A
PAGE 17
STANDARD VALLEY
The standard valleys are normally installed on low-pitched roofs 6/12and under and all slopes have the same angle. The 1/2” hem edge
on both sided of the valley act as a water diverter decreasing thechance of water getting under the shingles.
Use water return clips to secure the metal to the deck.Do not nail in the pan area or toenail to the deck.
STANDARD SIZE 15”W X 120”LA. 7”B. 7”C. 1/2” Water Return
STANDARD MATERIAL:Mill Finished Galvanized
SPECIAL ORDER MATERIALS:Painted Galvanized
Mill Finished AluminumPainted Aluminum
Copper
(Other Sizes Are Available Upon Request)
PAN PAN C 1/2” WATERRETURN
AB
PAGE 18
WALLThe standard wall flashing is normally installed where a non-
horizontal roof intersects a vertical wall. The back of the flashing isinstalled behind the siding or brick counter flashing. Shingles areinstalled over the 1/2” hem (water return) and lapped into the pan.
The 1/2” hem (water return) acts as a water diverter decreasing thechance of water getting under the shingles. Use water return clips to
secure the flashing to the deck. Do not nail into the pan.
STANDARD SIZE 9”W X 120”LA. 3 1/2”B. 5”C. 1/2” Water Return
STANDARD MATERIAL:Mill Finished 26 Ga. Galvanized
SPECIAL ORDER MATERIALS:Painted Galvanized
Mill Finished AluminumPainted Aluminum
Copper
(Other Sizes Are Available Upon Request)
BACK
PAN
A
BC Water Return
PAGE 19
WATERSTOP VALLEYWaterstop Valleys are normally installed on houses that have
different angles of roof slopes. The waterstop 1” raise diverter in thecenter will reduce the possibility of the water running across and
under the shingles on the side with the lower angle. The 1/2” hemedge on both sides also acts as a water diverter decreasing the
chances of water getting under the shingles. Use water return clips tosecure the metal to the deck. Do not nail in the pan area or toe nail to the deck.
STANDARD SIZE 18”W X 120”LA. 7 1/2”B. 7 1/2”C. 1” DiverterD. 1/2” Water Return
STANDARD MATERIAL:Mill Finished Galvanized
SPECIAL ORDER MATERIALS:Painted Galvanized
Mill Finished AluminumPainted Aluminum
Copper
(Other Sizes Are Available Upon Request)
A
B
DC
PAN
PAN
PAGE 20
WATER RETURN
NAILING CLIP
Nailing clips are used to secure flashingswith water return to the deck.
STANDARD SIZEA. 1/2”B. 1 1/2”C. 1/2”
STANDARD MATERIAL:Mill Finished Galvanized
SPECIAL ORDER MATERIALS:Painted Galvanized
Mill Finished AluminumPainted Aluminum
Copper
(Other Sizes Are Available Upon Request)
C
BC
AC
PAGE 21
COUNTER FLASHINGThe standard counter flashing is normally installed where a roof slopeintersects a brick wall. The counter flashing is attached to the brick
wall and flashes over any roof to wall flashing.
STANDARD SIZE 6”W X 120”LA. 1 / 4”B. 5 / 8”C. 4 – 3 / 8”D. 1 / 2”E. 1 / 4” w/ hem (optional)
STANDARD MATERIAL:Mill Finished 26 Ga. Galvanized
SPECIAL ORDER MATERIALS:Painted Galvanized
Mill Finished AluminumPainted Aluminum
Copper
(Other Sizes Are Available Upon Request)
C
A
BD
E
PAGE 22
WATER (RAIN) DIVERTER
Water diverter is used to divert water from falling off the roof onto anentryway or an air conditioner unit. Water diverters are used on
houses without gutters.
STANDARD SIZE 9”W X 120”LA. 7”B. 1 1/2”C. 1/2” Hem
STANDARD MATERIAL:Mill Finished Galvanized
SPECIAL ORDER MATERIALS:Painted Galvanized
Mill Finished AluminumPainted Aluminum
Copper
(Other Sizes Are Available Upon Request)
A
B
C
PAGE 23
TERMITE SHIELD
PAGE 24
Z - FLASHINGWhere an exterior wall is over eight feet tall. Z Flashing is used toflash where the two pieces butt between the top of the bottom and
bottom of the top sheet.
STANDARD SIZES:
SIZE METAL CUT SIZE A B C
1 / 2 ” 3” 1- 1 / 2 ” 1 / 2 ” 1 “5 / 8” 3” 1- 3 / 8 ” 5 / 8 ” 1 ”3 / 4 “ 3” 1- 1 / 4 ” 3 / 4 ” 1”
1 “ 3” 1 “ 1 “ 1”
STANDARD MATERIAL:Mill Finished Galvanized
AVAILABLE MATERIALS:Painted Galvanized
Mill Finished AluminumPainted Aluminum
Copper
(Other Sizes Are Available Upon Request)
A
B
C
PAGE 25
GRAVEL GUARD
PAGE 26
ANGLE
PAGE 27
STEP WALL
PAGE 28
WINDOW
PAGE 29
STEP COUNTER
PAGE 30
Chimney Tops
Chimney Pan w/TopChimney PanChimney Pan w/Top & ScreenStanding Seam Chimney TopChimney Cricket
PAGE 31
CHIMNEY PAN WITH TOP
WHEN ORDERING SPECIFY:CHIMNEY TOPS ARE CUSTOM FABRICATED TO FIT THE
FRAMING OF EACH CHIMNEY, ALL MEASUREMENTS HAVE TOBE FURNISHED WHEN ORDERING.
AVAILABLE MATERIALS:
MILL FINISHED 26 GA. GALVANIZEDCOPPER 16 OZ.
PAGE 32
(Other Sizes Are Available Upon Request)
CHIMNEY PANChimney Pans are designed to cap and flash the top of a chimney.
The flue pipe will extend through the pan.
CHIMNEY PAN SIZEWHEN ORDERING SPECIFY:1. Type Of Material2. Roof Pitch Or Degree3. Measurements Of A, B, C, D, & E
STANDARD MATERIAL:Mill Finished 26 Ga. Galvanized
SPECIAL ORDER MATERIALS:Copper, Stainless Steel
BOTTOM EDGE HAS _” HEM TURNEDINSIDE OF PAN
2 1/2”
2”
Chimney pan
SIDEVIEW
DA
B
C
E
PAGE 33
(Other Sizes Are Available Upon Request)
CHIMNEY PAN WITH TOP
SIZEWHEN ORDERING SPECIFY:
CHIMNEY TOPS ARE CUSTOM FABRICATED TO FIT THEFRAMING OF EACH CHIMNEY, ALL MEASUREMENTS HAVE TO
BE FURNISHED WHEN ORDERING.
AVAILABLE MATERIALS
MILL FINISHED 26 GA. GALVANIZEDCOPPER 16 OZ.
(Other Sizes Are Available Upon Request)
PAGE 34
STANDING SEAM
CHIMNEY TOP
SIZEWHEN ORDERING:
CHIMNEY TOPS ARE CUSTOM FABRICATED TO FIT THEFRAMING OF EACH CHIMNEY. ALL MEASUREMENTS HAVE TO
BE FURNISHED WHEN ORDERING.
AVAILABLE MATERIALS
MILL FINISHED 26 GA. GALVANIZEDCOPPER 16 OZ.
ANGLE VIEW
CAP
PIPE
END VIEW
CAP AND PIPE PICTURED FORILLUSTRATION ONLY
PAGE 35
METAL CRICKET
B
C
A
BCSIDE VIEW
A
(Other Sizes Are Available Upon Request)
CHIMNEY CRICKETA cricket is a small a-frame structure built on the up-roof side of thechimney. It spans between the roof and chimney and diverts the
water around the chimney.
CRICKET SIZEWHEN ORDERING SPECIFY:
1. Type Of Material2. Roof Pitch Or Degree
3. Measurements Of A, B, & C
STANDARD MATERIAL:Mill Finished 26 Ga. Galvanized
SPECIAL ORDER MATERIALS:Painted Galvanized
Mill Finished AluminumPainted Aluminum
Copper
PAGE 36
Miscellaneous
Water Heater A/C PanHeaderChimney CricketScupperWall ShieldSquare to Round Transition
PAGE 37
Water Heater and Air
Conditioner Safety PansDesigned for emergency overflow.
PAN SIZE
WHEN ORDERING SPECIFY:Type Of MaterialMeasurements Of A, B, & CSize Of Drain
STANDARD MATERIAL:Mill Finished 26 Ga. Galvanized
SPECIAL ORDER MATERIALS:Stainless Steel
Copper
(Other Sizes Are Available Upon Request)
A
C
BD 3/4”
PAGE 38
CONDUCTOR HEADS
Headers are used as a transition between scuppers/Gutters anddownspouts. Headers guide water from the scupper
or gutters into a drainpipe.
PAN SIZEWHEN ORDERING SPECIFY:
Type Of MaterialMeasurements Of A, B, C, D & E
STANDARD MATERIAL:Mill Finished Galvanized
Copper
SPECIAL ORDER MATERIALS:Mill Finish AluminumPainted AluminumPainted Galvanized
(Other Sizes Are Available Upon Request)
SIDEVIEW
B
C
A
C
DE
PAGE 39
METAL CRICKET
B
C
A
BCSIDE VIEW
A
CHIMNEY CRICKETA cricket is a small a-frame structure built on the up-roof side of thechimney. It spans between the roof and chimney and diverts the
water around the chimney.
CRICKET SIZEWHEN ORDERING SPECIFY:
4. Type Of Material5. Roof Pitch Or Degree
6. Measurements Of A, B, & C
STANDARD MATERIAL:Mill Finished 26 Ga. Galvanized
SPECIAL ORDER MATERIALS:Painted Galvanized
Mill Finished AluminumPainted Aluminum
Copper
PAGE 40
Scupper
Used to drain water through a parapet wall. In most cases, scuppersare used in conjunction with headers and downspouts.
Custom Made
PAGE 41
Wall Shield
Wall Shield is designed to flange over dryer or kitchen exhaust fans.
Kitchen Duct Size: 7" - Other Sizes Available
Custom Made
PAGE 42
Square to Round
Transition
Square to Round Transition - Normally used when connecting asquare or rectangular downspout into a round underground drainpipe.
Custom Made
PAGE 43
CONTACT US...
www.hinkleymetalproduts.com
Top Related