OLAND A/S 70 20 19 11 www.totalventilation.com
76
With the Oland standard range of rectangular ducts and fittings, strong, rigid and airtight duct systems can be built quickly and economically.Both ducts and fittings are manufactured to order.
Ducts and fittings are manufactured in accordance with DS447 (ventilation standards), and are designed for a pressure or Vacuum of up to 1000Pa. ( 100mm vc).
The Oeland duct system is manufactured to tightness class B, but can be ordered and manufactured to tight-ness class C.
Material Quality StandardGalv sheet DX51D+Z275MA EN10142 tol. EN10143OS-Grid DX51D+Z275MA EN10142Joint filler Acrylic fillingTightening rubber Standard Polyethylen Application temperatures from -70°C to +80°C.
Tolerance:
A and B give the ducts internal measurementsAverage size A/B +0 -4 mm (A+B)< 1200 mmAverage size A/B +0 -6 mm (A+B) > 1200 mmLenght L +6 -0
Alternative materialsRust free acid proof AISI 316L / SIS2343 / EN1.4404Aluminium 2S ½HAluminium 57S½H
Rectangular ducts Largest side length (mm) 1-500 501-999 >1000 AlternativSheet thickness galvanised (mm) 0,6 0,7 0,9 1,25Sheet thickness rust free acid proof (mm) 0,5 0,7 0,7
The width of the sheets in the table is applicable to a pressure of 1000 Pa under the assumption that duct sides are dia-gonally crossed or are made in such way that the largest side length is over 300mm..
Bearings:
The distance between supports depends on the ducts’ tight-ness and the total cross sections. Supports distance should be highest 2m. Finally expansion bolts can be subjected to permanent load of 200N and short term with 1000N pr. bolt.
A
B
Rectangular ducts in general
OS OS-bearing
LOS Movable OS-bearing
EBM OS endplate mounted
SMOOTH Smooth
BEBM Tray-endplate mounted
HF High folds 25 mm
HF30 High folds 30 mm
HF40 High folds 40 mm
BF Concealed folds
Assambling code
Assembling:
Exterior corner Type UH should be fitted to
choice.
Connecting bar Type C are inserted by sliding
them together
Ducts are connected together
Sealing strip Type OTShould be inserted in the
groove
All products are be delivered withOS bars as standard.Contact Oeland if other bar types are demanded.
OS Installation instructions
Pressure loss charts: See pressure loss values on www. totalventilation.com
OLAND A/S 70 20 19 11 www.totalventilation.com
77
For flexible branching of rectangular ducts. Has a standard length of 100mm and is fitted with OS- strip in one end and a folded seam HF-40 on the other end
The ST has a standard length of 100mm and is fitted with an OS strip in one end and a folded seam HF40 on the larger end. For length bigger than 100mm use type SS.
The ducts are delivered in standard lenghts of 1000, 1500 and 2000. They can be produ-ced for special orders. Ducts are as standard fitted with OS.Check generally for alternative assembling codes. Ducts are braced when one side is exceeds 800mm.
Also available in rust free version: Type RKAS
L
B
A
DuctType KA
KA - A - B L= S1/S2eks. KA - 300 - 200 L=1000 OS/OS
Order information:
Also available in rust free version: Type RST
A
A+100
B
L
HF40
ST - A - B L= S1/S2Eks. ST - 500 - 700 L=100 OS/HF40
Order information:
BranchType ST
A B
L = 100
HF40
TUD - A - B - L Længde
Order information:
NozzleType TUD
OLAND A/S 70 20 19 11 www.totalventilation.com
78
Type KB is manufactured to degrees 1-90°. The standard radius is 100, A and A2 can differ, but for B it is always equal. The standard type is fitted with OS at both ends
Also available in rust free version: Type RKB
A
BA2
A
B
A2
A2
II
A
A x B
I
A2x
B
R 100
25S1
S2
KB - GR - A - B - A2 (R / I / II) S1/S2eks. KB - 90 - 500 - 300 - 200 OS/OS
Order information:
Type FB is manufactured to degrees 1-180°. The standard Radius=100, A and A2 can dif-fer but for B it is always equal. The standard type is fitted with OS at both ends.
Also available in rust free version: Type RFB
A
B
A2
A
BA2
A x B
IA
2 x
B
II
R 100
S1
S2
25
A
A2
FB - GR - A - B - A2 (R / I / II) S1/S2eks. FB - 90 - 500 - 300 - 200 OS/OS
Order information:
The guide plates are fastened with a tin-dowel. The tin dowel gives a strong connection with the help of a ø11 mm drill and hammer. The tin-dowel can withstand a pull of 100kg and can be applied on sheet thickness of up to 1,25 mm. The rubber packing assures a tight assembling. The radius is shown in the tables. Guide plates are only produced to order.
1. Guide plate : A < 550
35% of A-measurement
A
A2
2 Guide plate : 550 <= A < 1000
15% of A-measurement
A
A2
40% of A-measurement
3. Guide plate : 1000 <= A
12% of A-measurement
A
A2
25% of A-measurement52% of A-measurement
Bend ductType KB
Guide plate for KB and FB
Bend ductType FB
OLAND A/S 70 20 19 11 www.totalventilation.com
79
The standard length is L=100mm.The standard make is centric, but can also be produced with straight sides.Is delivered with OS.
Rust free version: Type RPSF
L =
100
A
Ø
B
Ø
L =
100OS
Ø
A B
L
PSF - A - B - Ø L= S1PSF - 200 - 500 - Ø315 L=100 OS
Order information;
There is a length limit on the offset C.Contact Oland
Rust free version Type RSB
L
C
A
B
SB - A - B L= C= S1/S2eks. SB - 800 - 500 L=600 C=300 OS/OS
Order information;
Branch from round - squaredType PSF
S-BENDType SB
BA
L
SKN - A - B L= GR S1/S2SKN - 500 - 400 L=100 GR=45 OS/OS
Order information;
Angular ductType SKN
OLAND A/S 70 20 19 11 www.totalventilation.com
80
It doesn’t matter from which side you look at the reduction piece. It is therefore important to define reference points. Reference point 1 is to your bottom left side(see fig. A)
Measure how reference point 2 is located in relation to reference point1. This will give offset c,d and
length L.See fig B if you are in doubt
whether it is + or -.
Imagine the axis c and d through reference point 1.( fig B)
referencepoint
1
A
B
B2
2
A2
referencepoint
2
A2
B2
B
1
A
Fig. A -c-c,+d +c,+d
-c,-d +c,-d
-d
+c
+d
1
referencepointto A2 x B2
referencepointto A x B =
duct piece facingyou
c
d
1
2
L
duct piece facingyou
The type SS reducer is manufactured with built-in offset and length upon request. ( see table for standard lengths)Specify the type no v (1-5) or the off-set c or d.Please read the instructions at the bottom of this page in order to define the item correctly.Delivered as standard with OS.
Rustfree version: Type RSS
B A
B2A2
L
A
B
d
c
A2 x B2S2
LA2
B2 A x BS1
V=1 V=2 V=3 V=5V=4
V=2 V=3 V=5V=4
varianttyper
SS - A - B - A2 - B2 L= v (eller c/ d)= S1/S2Eks. SS - 800 - 500 - 400 - 300 L=450 v=4 OS/OS
Order information:
A
B
d
c
The type OG reducer is manufactured with built-in offset and length upon request. ( see table for standard lengths) Specify the type no. v (1-5) or the off-set c or d.Please read the instructions at the bottom of this page in order to define the item correctly.Delivered as standard with OS.
Rust free version: Type ROG
Ø
L
AB V=2 V=3 V=5V=4
V=1 V=2 V=3 V=5V=4
OG - A - B - Ø L= v (eller c/d)= S1OG - 600 - 400 - 315 L=450 v=4 OS
Order information:
Standard lengths for OG/SS:Largest side < 350 : L = 300 mmLargest side > 350 < 800 : L = 450 mmLargest side > 800 : L = 600 mm
ReducerType SS
Order Instructions for SS and OG
Reduction pieceType OG
Standard lengths for OG/SS:Largest side< 350 : L = 300 mmLargest side > 350 < 800 : L = 450 mmLargest side > 800 : L = 600 mm
OLAND A/S 70 20 19 11 www.totalventilation.com
81
Type FT is manufactured with radius=100.It is delivered with OS as standard.
Also available in rust free version: Type RFT
A2
B
A
A3
II III
I
A2A3
A
R
FT - A - B - A2 - A3 S1/S2/S3 (I/II/III)eks. FT - 400 - 500 - 300 - 200 OS/OS/OS
Order information
The flexible-joint FLF to REDUCE noise, heat or vibrations in the ventilation system.
Example: from ventilation to ducting string.The flexible connection total length = 150 mm 45/60/45=60mm flex migration.
Temperatures -30°-+70°
It is delivered with Os as standard.
AB
FLF - A - B S1/S2eks. FLF - 350 - 500 OS/OS
Order information:
T- pieceType FT
Flexible-jointType FLF
OLAND A/S 70 20 19 11 www.totalventilation.com
82
The endplate type EB is for installation on a OS- end. The EB can be delivered ready assembled: type EBM
Also available in rust freeversion: Type REB
A
B10
EB - A - Beks. EB - 400 - 300
Order information
A
B
10
The OS- endplate type EBN with mesh to install on a OS-end.The EBN can be delivered ready assembled: type EBMN
EBN - A - Beks. EBN - 500 - 400
Order information
OS-EndplateType EB
OS Endplate Type EBN
A
B
The endplate tye BEB is for installation on a plain end and is installed with screws and jointed.The BEB can be delivered ready assembled: type BEBM
BEB - A - Beks. BEB - 400 - 300
Order information
Tray EndplateType BEB
OLAND A/S 70 20 19 11 www.totalventilation.com
83
F - 60 - A - Beks. F - 60 - 500 - 400
SPJ - A - Beks. SPJ - 500 - 400
The rectangular duct damper type SPJ for regulation or shut-off.
The damper blade has a thickness of 1.25 mm as standard with a through going shaft. It can be adjusted from the outside with a lever turning from 00 – 900.
L = B + 50
L
A
B
B
H
The fire damper type F60 is designed for fire protec-tion in ventilation systems.
The fire shutters are of the louvre type with self-lock-ing slats, made from galvanized steel plate.
The fire damper is fitted with a safety fuse calibrated for a melting point of 700C, but they can also be delivered with safety fuses for other temperatures on demand.
All fire dampers are equipped with 2 springs in order to secure a positive shut off, and they can be mounted both vertically and horizontally.
Order information:
Snit X-X
110
X
X
B
H
Sound absorberType SPJ
Fire damperType F60
Order information:
OLAND A/S 70 20 19 11 www.totalventilation.com
84Fire damperType ETPS-EI
The ETPS-E1 is a rectangular fire damper. The damper casing is made from warm galvanized steel plate with flanged connections in both end and two inspection hatches.The damper blade is made of calcium silica. The blade shafts are made from stainless steel.The overall length is 500 mm as standard. Shorter versions of 400mm or 335 mm are also avai-lable together with a additional mounting frame.(to be ordered separately)The fire damper type ETPS-1 meets the European standard EIS-90 and it has been tested to the standard EN 1366-2. The damper meets tightness class C.The fire damper unit should be mounted with the blade shaft in either vertical- or in a horizontal position.For further information and ad-vice, please visit us at: www.totalventilation.com
ETPS-EI - B - H - C - D
D = release system 1 = safety fuse 70°C 2 = safety fuse 90°C 3 = 24V with thermal sensor 4 = 24V 5 = 230V with thermal sensor 6 = 230V C = overall length mm 1 = 355 mm( + frame ER2 or ER3) 2 = 400 mm 3 = 500 mm (standard)
Width mm (200-1500)
Height mm (200-800)
For other solutions , please contact Oland A/S, or visit us at: www.totalventilation.com
120
L = 355L = 400L = 500K
KK
K
355400
500
(B+37 / H+37)±7
7
10.5 10.5
70
35 35
3535
B
H
For Fire dampers class E30- E120, please Oland A/S, or visit us at: www.totalventilation.com
35
15
B
15
15
n x 200 x
1535
n x
200
x
H
220
B/H 200 250 300 350 400 450 500 600 700 800 900 1000 1100 1200 1300 1400 1500x 120 145 170 195 120 145 170 120 170 120 170 120 170 120 170 120 170n 0 0 0 0 1 1 1 2 2 3 3 4 4 5 5 6 6
Fire damperType ETPS-E
OLAND A/S 70 20 19 11 www.totalventilation.com
85
JAL t.motor
JAL u.motor A
B
The JAL louver damper is designed for continuous regula-tion of the air flow through a ventilation system.It is air tight, but it is NOT gas tight.The dampers are designed to be attached to air conditio-ning units and as dampers in mixing chambers.The dampers are designed for a temperature range bet-ween -200C and + 1000C with a pressure difference of up to 400 Pa and 80% relative humidity.The max air velocity through the damper is 20 m/sec.
JAL - T - A - B
H Hand operatedM Prepared for motor
Louvre damperType JAL
A 200 300 400 500 600 800 1000 1200 1400 1600 1800 2000
200 0,032 0,048 0,065 0,081 0,097 0,129
300 0,048 0,073 0,097 0,121 0,145 0,194 0,242 0,291
400 0,065 0,097 0,129 0,162 0,194 0,258 0,323 0,388 0,452 0,517
500 0,081 0,121 0,162 0,202 0,242 0,323 0,404 0,485 0,565 0,646 0,727 0,808
600 0,097 0,145 0,194 0,242 0,291 0,388 0,485 0,582 0,678 0,775 0,872 0,969
800 0,129 0,194 0,258 0,323 0,388 0,517 0,646 0,775 0,905 1,034 1,163 1,292
1000 0,215 0,323 0,404 0,485 0,646 0,808 0,969 1,131 1,292 1,454 1,615
1200 0,259 0,388 0,485 0,582 0,775 0,969 1,163 1,357 1,551 1,745 1,938
1400 0,452 0,565 0,678 0,905 1,131 1,357 1,583 1,809 2,035 2,262
1600 0,646 0,775 1,034 1,292 1,551 1,809 2,068 2,326 2,585
1800 0,727 0,872 1,163 1,454 1,745 2,035 2,326 2,617 2,908
2000 0,808 0,969 1,292 1,615 1,938 2,262 2,585 2,908 3,231
Free area (m²) with 100% opening
The JAL damper can be fitted to the duct by means of an OS20 flange. The fitting is done with C strip or mounting screws. The main body of the damper is made from un-treated aluminium.
The seals at the damper blades are made of a special rubber composition.The moving parts of the damper unit are outside the airstream.
A [m]
B [m
]
2,0
1,5
1,0
0,5
00,5 1,0 1,5 2,0
20Nm
15Nm
10Nm
5 Nm
Necessary momentum value for clo-sure of the door and service motor.
OLAND A/S 70 20 19 11 www.totalventilation.com
86
1000
100
10
11 2 3 4 5 6 7 8 9 10v [m.s-1]
pres
sure
loss
p [P
a]
75 dB(A) 80 dB(A) 84 dB(A) 85 dB(A)
α=25°
v [m.s-1]
0°
30°
60°
Air flow
Air velocity and pressure loss across the damper, including the intensity noise level for xxx, at different opening angles of the rails.
1000
10
100
p [P
a]
10 1001 1000360036 68,4 100 360 10003,6 10
Volume flow qVLBA [l.s. m-2][m3h-1m-2]
4 123Density class
Tightness classes at different pressure loss, measure after DIN 1964, EN 1751.
The airflow qv showsJAL curve in a diagram and also in a louvre damper tightness class. The pres-sure loss line is decided at the intersection as given and the airflow can therefore be decided to.
qvlba = 68,4 m3. h-1. m-2
Find the ducts average area from the following: S = A x B = 1,4 x 1,6 = 2,24 m2
Following that the total airflow through a louver damper will be: qv = qvlba. S = 68,4 x 2,24 = 153,2 m3. h-1
Louvre damperType JAL
OLAND A/S 70 20 19 11 www.totalventilation.com
87
B
H
The louvre grate type PZA is used as an external grate for inlet- or exhaust air.The tilted slats prevent water to enter the duct behind it.The grate is made from polished aluminium.
net
40
Non recomended area
Inlet
Exha
ust
100
80
60
5040
2
10
20
30
5
pres
sure
loss
∆P
t [P
a]
3 4 5 109876
v [m.s-1]Air velocity
432,521,510,50,40,20,13
Pre
ssur
e lo
ss [
m3 /
h]5000
10000150002000025000
30000
3500038000
Effect area [m2]
A 200 250 300 350 400 450 500 600 700 800 900 1000 1200 1400
200 0,03 0,03 0,04 0,05 0,05 0,06 0,07 0,08 0,10 0,11 0,12 0,14 0,17 0,19
250 0,03 0,04 0,05 0,06 0,07 0,08 0,09 0,10 0,12 0,14 0,16 0,18 0,21 0,25
300 0,04 0,05 0,06 0,07 0,08 0,09 0,11 0,13 0,15 0,17 0,19 0,21 0,26 0,30
350 0,05 0,06 0,07 0,09 0,10 0,11 0,12 0,15 0,18 0,20 0,23 0,25 0,30 0,36
400 0,05 0,07 0,08 0,10 0,11 0,13 0,14 0,17 0,20 0,23 0,26 0,29 0,35 0,41
450 0,06 0,08 0,09 0,11 0,13 0,14 0,16 0,20 0,23 0,26 0,30 0,33 0,40 0,46
500 0,07 0,09 0,11 0,12 0,14 0,16 0,18 0,22 0,26 0,29 0,33 0,37 0,44 0,52
600 0,08 0,10 0,13 0,15 0,17 0,20 0,22 0,26 0,31 0,35 0,40 0,44 0,54 0,63
700 0,10 0,12 0,15 0,18 0,20 0,23 0,26 0,31 0,36 0,42 0,47 0,52 0,63 0,73
800 0,11 0,14 0,17 0,20 0,23 0,26 0,29 0,35 0,42 0,48 0,54 0,60 0,72 0,84
900 0,12 0,16 0,19 0,23 0,26 0,30 0,33 0,40 0,47 0,54 0,61 0,67 0,81 0,95
1000 0,14 0,18 0,21 0,25 0,29 0,33 0,37 0,44 0,52 0,60 0,67 0,75 0,91 1,06
1200 0,17 0,21 0,26 0,30 0,35 0,40 0,44 0,54 0,63 0,72 0,81 0,91 1,09 1,27
1400 0,19 0,25 0,30 0,36 0,41 0,46 0,52 0,63 0,73 0,84 0,95 1,06 1,27 1,49
Net opening.
PZA- B - HHeightWidth
Lovre grillType PZA
Ikke anbefalet område
Indtag
Afka
st
100
80
60
5040
2
10
20
30
5
trykt
ab ∆
Pt
[Pa]
3 4 5 109876
v [m.s-1]Lufthastighed
Order information:
OLAND A/S 70 20 19 11 www.totalventilation.com
88
With 30mm insulation.
For fitting to ducts, both plain and insulated.
B
A
For fitting to ducts.
B
A
Productnr.
Amm
Bmm
IIL-3 150 240
IIL-2 240 375
IIL-1 368 500
IIL-0 500 649
Productnr.
Amm
Bmm
Weightkg
LEM-5 200 100 0,37
LEM-4 300 200 1,05
LEM-3 400 300 2,07
LEM-2 500 400 4,18
LEM-1 600 500 7,1
Insulated inspection hatchType IIL
Inspection hatchType LEM
IIL - Nr
3 : 150 - 2402 : 240 - 3751 : 368 - 5000 : 500 - 649
LEM - Nr1 : 200 - 1002 : 300 - 2003 : 400 - 3004 : 500 - 4005 : 600 - 500
For fitting to ducts.
Ø
Inspection hatchType INS
Ødnommm
Amm
Bmm
Weightkg
80 180 80 0,3
100 180 80 0,3
125 180 80 0,3
160 200 100 0,4
200 200 100 0,4
250 200 100 0,4
315 200 100 0,4
400 300 200 1,0
500 300 200 1,0
630 400 300 2,0
800 400 300 2,0
1000 500 400 4,0
1250 500 400 4,0
OLAND A/S 70 20 19 11 www.totalventilation.com
89
ITUD - A - B L= S1/S2eks. TUD - 300 - 200 L=100 OS/HF40
Insulated ducts and fittings are insulated internally 50mm mineral wool as standard. The insulation should be sealed in fragments so as to avoid damage.The insulated ducts and fittings are delivered without bracing.
B
L = 100
A
Insulated passage nozzle-Type ITUD
Order information:
A
B
II =
100
I = 100
a
Insulated ducting bendType IKB
IKB - A - B - a S1/S2eks. IKB - 500 - 300 - 200 OS/HF
Order information:
A
B
15
Insulated endplateType IEB
IEB - A - BIEB - 200 - 350
Order information:
L
B
A
Insulated ductType IKAS
IKAS - A - B L= S1/S2eks. IKAS - 700 - 500 L=1000 OS/EB
Order information:
Insulated ducts and fittings
AB
1000
300
Insulated roof hood, lead- in type ITGFG
ITGFG- A - B - GR = S1/S2eks. ITGFG -700-700 GR=
Order information:
ab
L
AB
Insulated Redcuction pieceType ISS
ISS - A - B - a - b L= S1/S2ISS - 500 - 300 - 600 - 200 L=400 OS/OS
Order information:
When using pre-insulated ducts for fire insulation or condensation insulation or other forms of insulation the weight should not exceed 5kg/m² equivalent to BS 30 which is the standard weight with e.g 50mm fire insula-tion batts.
OLAND A/S 70 20 19 11 www.totalventilation.com
90
AB
L
h = 300
With galvanised flashing0° flashing
Standard length 1000mm.
All roof hoods should be jointed.
Also available in rust free version: Type RTGF-0-A-B
With 45° flashing.
Standard length is 1000mm.
All roof hoods should be jointed.
AB
L
h= 300
Rectangular roof hood 0°Type FTGFG
Rectangular roof hood 45°Type FTGFB-45
FTGFG - 0 - 500 - 300 L=1000
FTGFG - GR - A - B L=
Order information
eks. FTGFB - 45 - 500 - 300 L=1000
FTGFB - GR - A - B L=
Order information:
OLAND A/S 70 20 19 11 www.totalventilation.com
91
The roof hood type LOF is applied as an intake and exhaust hood. Delivered in rec-tangular and squared shapes, but separable with 100mm.(Other measurements can be ordered)The form of the grills makes the type LOF have a large free- area and at the same time keeping the rain out.
Type LOF is designed from galvanized sheets.Weight:
Approx weight: ( for galvanized version)36x H x (A+B)
H
AB
eks. LOF - 600 - 600 H=485 LOF - A - B H=
4 6 8 10 12 14 16 18 20 22 24 26 28 30
A B 285 385 485 585/ 685 785 885 985 1085 1185 1285 1385 1585 1585
300 - 300 1.814 2.721 3.628 4.536 5.443 6.350 7.257
400 - 400 2.419 3.628 4.838 6.048 7.257 8.467 9.676 10.886 12.096
500 - 500 3.024 4.536 6.048 7.560 9.072 10.584 12.096 13.608 15.120 16.632
600 - 600 3.628 5.443 7.257 9.072 10.886 12.700 14.515 19.329 18.144 19.958 21.772 23.587
700 - 700 4.233 6.348 8.464 10.580 12.696 14.812 16.928 19.044 21.160 23.276 25.392 27.508 29.264 31.740
800 - 800 4.836 7.254 9.672 12.096 14.508 16.926 19.344 21.762 24.180 26.598 29.016 31.434 33.852 36.270
900 - 900 5.440 8.160 10.880 13.608 16.320 19.040 21.760 24.480 27.200 29.920 32.640 35.360 38.080 40.800
1000 - 1000 6.048 9.072 12.096 15.120 18.144 21.168 24.192 27.216 30.240 33.264 36.288 39.312 42.336 45.363
1200 - 1200 7.256 10.844 14.514 18.144 21.768 25.396 29.024 32.652 36.280 39.908 43.536 47.164 50.792 54.420
1400 - 1400 8.464 12.696 16.928 21.168 25.392 29.624 33.856 38.088 42.320 46.552 50.784 55.016 59.248 63.480
1600 - 1600 9.676 14.514 19.352 24.192 29.028 33.866 38.704 43.542 48.380 53.218 58.056 62.894 67.732 72.570
1800 - 1800 10.884 16.326 21.768 27.216 32.652 38.094 43.536 48.978 54.420 59.862 65.304 70.746 76.188 81.630
2000 - 2000 12.096 18.144 24.192 30.240 36.288 41.336 43.384 54.432 60.480 66.528 72.576 78.624 84.672 90.720
Number of pallets / Hight L
The capacity diagram in m³/h for squared roof hoods.The marked area= Recommended airflow volume at the intake for roof hoods.Airflow volume is measured from the exterior max. 5m/s at the neck of the roof hood or 3m/s between the bars.
80
30
40
506070
1,5115
20
2 43 4,5
Air velocity through roof hood m/s
Pre
ssur
e lo
ss 4
Ps
Pa
ExhaustInlet
Roof hood with pallets Type LOF
The capacity diagram in m³/h for squared roof hoods.
n = total palettesQ = air volume [m3/h]F = free area [m2]v = air velocity [m/s]H = height [m]A,B = [m]
F = Q
v . 3 6 0 0
n = F
2 . ( A + B ) . 0 , 0 3 5
v =Q
F . 3 6 0 0
v = 8 5 + 5 0 . n
F = 2 . ( A + B ) . n . 0 , 0 3 5
Order information
OLAND A/S 70 20 19 11 www.totalventilation.com
92
Sound absorbers are manufactured with OS- connections to rectangular ducts. The duct is un-insulated or insu-lated internally. Various lining alternatives can be chosen depending of the operating conditions.
Sound absorbers can be of several configurations:LD: Straight sound absorbers of the absorption type.LD/LDH: Angled sound absorbers of the absorption type.LBB: Straight sound absorbers for limited building space.
Description:The sound absorbers comprises a duct made from warm galvanized steel plate and a number of built-in baffles. The duct is made as type KA.To facilitate cleaning, the sound absorbers are fitted with an inspection hatch with snap locks for easy handling.
Rectangular Sound absorber
Use the Windsound-programme for calculations. It can be downloaded for free from www.totalventilation.com
The LD is a duct with installed baffle(type LDB)The baffles are galvanised frames with black bars. To avoid damage the insulation is lined with black fragments.Maximum speed 15m/s.BT: baffle thicknessBA: baffle distance.
The sound level for the airflow velocity sound intensity should lie at least 7-10 db below the sound from the whole unit in the area where the sound absorber is placed.
Rust free version : Type RLD - bb-ba-A-B-L
B
A
L
BTBA
Sound absorberType LD
LD - BT - BA - A - B L= S1/S2LD - 200 - 100 - 900 - 1200 L=1000
Order information
The LD and the LH/LV types are sound absorbers of con-ventional type with baffles made from glass wool plates.
The LLD sound absorber is a type with high damping in the 250 Hz. octave band, and this is normal dimensio-ned. Moreover the damping of frequencies at 63, 125 and 500 Hz should be given priority over higher frequen-cies.
The LBB type is made especially for installations with limited space. This will give high damping in the lower octave bands and the damping element is placed at the largest side within the absorber.
Lydberegningsprogram se www.totalventila-tion.comLydberegningskode for LD : BAKR-1
OLAND A/S 70 20 19 11 www.totalventilation.com
93
LBB - A - B L= S1/S2eks. LBB - 400 - 600 - 650 OS/OS
B
L
BT
Rectangular sound absorberType LDB
LDB - A - B L= S1/S2LDB - 400 - 600 - 650 OS/OS
Order information
B
BABT
A
c
d
A
B
BTBT BA
BA
½ BAc d
The LH is a duct bend lined with a baffle type LDB vertically. BT : Baffle width , BA: Baffle distance. min. length for d + c 100mm.
½ BA
A
A
BT
BA
½ BABTBA
Angle Sound absorber Type LH
LH - A - B L= S1/S2LH - 400 - 600 - 650 OS/OS
Order information
The LV is a duct bend lined with a baffle type LDB vertically. BT : Baffle width , BA: Baffle distancemin. length for d + c 100mm.
Angle Sound absorber Type LV
LV - A - B L= S1/S2LV - 400 - 600 - 650 OS/OS
Order information:
Type LBB is a special sound damper for limited building heights.It gives a high dam-ping effect in the low bands octave.
L
A
B
Sound absorber(low octave band)Type LBB
Order information:
Mineral wool is placed on the largest side of the baffleBaffle height er 1/2 A.
Sound calculation programme see www.totalventilation.comSound calculation code for LBB : BAKR-8
Sound calculation programme see www.totalventilation.comSound calculation for LV : BAKR-2
Sound calculation programme see www.totalventilation.comSound calculation for LH : BAKR-2
OLAND A/S 70 20 19 11 www.totalventilation.com
94
Type UH
Type OS
Flange profile
Type C
Brace for OS20
Type OT
Strip mounting
Type OH
Internal corner for OS
Type OK
Terminal screw
Type BFS
Bars External corner for OS-20
Cornertype STAT-2and SSTAT-2
Tube L=3000type STAT-1and SSTAT-1
T-tubetype STAT-3and SSTAT-3
Foottype STAT-4and SSTAT-4
Angle 45°type STAT-6and SSTAT-6
Plasticcaptype STAT-8and SSTAT-8
Wall fittingtype STAT-5and SSTAT-5
Angle 90°type STAT-7and SSTAT-7
T-Crosstype STAT-9and SSTAT-9
Adjustable foot type type STAT-10
FrameworkType STAT / SSTAT
Installation Accessories
Framework system in electro-galv. materials.STAT : Tube 35x35x1,5 fittings 40x40x1,5
SSTAT : Tube 45x45x1,5 fittings 50x50x1,5
OLAND A/S 70 20 19 11 www.totalventilation.com
95
ApplicationThe Oeland pressure monitors TK-1, TK-2, TK-3 and TK-4 is an automatic monitor series designed for control-ling over-/underpressure in ventilation systems and in industrial process air plants.If the pressure settings in the plant (in Pa) is not cor-rect, the monitor will give both a visual and an acoustic alarm signal. A pressure sensor panel is positioned in the control room next to the operator, and it is connected to a pressure transducer Climair 930.4 variants are available covering a range of 20- 2500 Pa.
Presure monitorType TK
Trykvagt - TK - T
1: 20 - 200 Pa2: 50 - 500 Pa3: 200 - 1000 Pa4: 500 - 2500 Pa
Measure area
90mm
115mm
57,5mm
118mm
65mm
55mm
1 2
3
TRYKKONTROL TK230
POWER TEST ALARM
STOP SIRENE
ALARM
Ver.2
TK230Pressure monitor: Climair 930.xx
Dimensions
Caliberation set 6555This set involves 2 aluminium pipes and rubber nozzles and a 2m PVC- horse. The set is installed in the places, where there is specifically wished to measure the pressure in the ventilations system. .
100
Ø6
Ø16
Type Measure area TRYKVAGT-TK-1 20 - 200 Pa Pressure monitor-TK-2 50 - 500 Pa Pressure monitor-TK-3 200 - 1000 Pa Pressure monitor-TK-4 500 - 2500 PaDescription:Oland Pressure monitor-K-1,TK2,TK3 and TK-4 com-prises the following: Pressure control board TK230 Pressure monitor Climair 930Measurement set 6555
Pressure monitor Climair 930 Pressure monitor for over-pressure or under-pressure.The desired pressure level is indicated on the scale button.
Pressure control panel TK230
Display legend:POWER: Green operation lightALARM: Red alarm light blinks if the
pressure is not constant and after 15sec the siren goes off.
STOP SIREN: A stop button that can be used to get stop the siren.
TEST ALARM: There is a pressure button which can be used to test the alarm and siren circuits.
The battery backupIn a power failure situation the battery is automatically sup-
plied with power. The capacity is 24 hours of operation and 2 hours alarm.
65
65 84
101
57,5
Ø6
-+
65
65 84
101
57,5
Ø6
-+
OLAND A/S 70 20 19 11 www.totalventilation.com
96
Product nr. Product Quantity
SK-S-13 Self drilling screw 4,2x13 1000 pieces
SK-S-20 Self drilling screw 4,2x19 1000 pieces
SK-S-25 Self drilling screw 4,2x19 squared head 1000 pieces
SK-S-38 Self drilling screw 4,8x38 500 pieces
SK-S-50 Self drilling screw 4,8x50 500 pieces
SK Self drilling screw 4,2x13 1000 pieces
Product nr. Product Quantity
BOLT-6x25 Steel tbolt FZ M 6x25 200 pieces
BOLT-6x40 Steel tboltFZ M 6x40 200 pieces
BOLT-8x25 Steel tbolt FZ M 8x25 200 pieces
BOLT-8x40 Steel bolt FZ M 8x40 200 pieces
BOLT-10x25 Steel bolt FZ M 10x25 100 pieces
BOLT-10x40 Steel bolt FZ M 10x40 100 pieces
MØTRIK -6 Nut -M-6 100 pieces
MØTRIK-8 Nut -M-8 100 pieces
MØTRIK-10 Nut-M-10 100 pieces
Product nr. Product Quantity
FRANSKE-SKRUER-6x40 French screw 6x40 200 pieces
FRANSKE -SKRUER-8x50 French screw 8x50 200 pieces
Product nr. Product Quantity
MS Hexagonal magnetic screw holder 1/4" 1 piece
MS-S Squared magnetic screw holder 1 piece
MS-7 Screw holder 1 piece
MS-8 Magnetic screw holder M8 1 piece
MS-10 Magnetic screwholder M10 1 piece
Product nr. Product Quantity
EKSPRESANKER-6x45 Anchor bolt str. 6x45 100 pieces
EKSPRESANKER-6x65 Anchor boltstr. 6x65 100 pieces
Product nr. Product Quantity
PLUGS-8 Nylon dowel M-8 100 pieces
PLUGS-10 Nylon dowel M-10 50 pieces
PLUGS-12 Nylon dowel M-12 25 pieces
Product nr. Product Quantity
POP-1 Galvanised rivet Str. 3,2x6 500 pieces
POP-2 Galvanised rivet Str. 3,2x8 500 pieces
POP-3 Galvanised rivet. Str. 3,2x12 500 pieces
BOR-POPNITTE Rivet 3,3 dobbelt 1 piece
Product nr. Product Quantity
FUGE-VENTITÆT Vent tight acrylic paste 310 ml
FUGE-MULTI GRÅ Grey multipaste 290 ml
FUGE-MULTI HVID White multipaste 290 ml
FUGE-SILICONE HIVD Grey building silicone 310 ml
FUGE-SILICONE HIVD Clear building silicone 310 ml
FUGE-TAG Black roof paste 300 ml
FUGE-SKUM Universal foam 825 ml
FUGE-BRANDKONST. Grey fire constuction 310 ml
FUGEPISTOL-HALVSKÅL Half tube paste pistol 1 piece
FUGEPISTOL-SKILLET Separated paste pistol 1 piece
Accessories
OLAND A/S 70 20 19 11 www.totalventilation.com
97
Product No Product Quantity
HUL-SAV-70 Orifice saw size. 70 without holder 1 piece
HUL-SAV-108 Orifice saw size. 108 without holder 1 piece
HUL-SAV-133 Orifice saw size. 133 without holder 1 piece
HUL-SAV-168 Orifice saw size. 168 without holder 1 piece
HUL-SAV-210 Orifice saw size. 210 without holder 1 piece
BOR-HULSAV Orifice saw drill 1 piece
HULSAV-HOLDER Holder for Orifice saw 11,1 mm incl. Drill 1 piece
Product No. Product Quantity
SKÆRESKIVE-115 Cutting plate size 115x1,6 mm 1 piece
SKÆRESKIVE-125 Cutting plate str.125x1,6 mm 1 piece
SKÆRESKIVE-150 Cutting plate str. 150x1,6 mm 1 piece
SKÆRESKIVE-180 Cutting plate str. 180 mm 1 piece
Product nr. Product Quantity
HÅNDPLADESAKS-HØJRE Bacho Right hand Shears 1 piece
HÅNDPLADESAKS-VENSTRE Bacho Left hand Shears 1 piece
Product nr. Product Øuantity
HØREVÆRN-BØJLE Ear Plugs on loop 1 piece
BESKYTTELSES-BRILLER Protection Goggles 1 piece
Product nr. Product Quantity
SKRUETRÆKKER-FLEX Screw driver 7 mm t/ flexible clip 1 piece
SKRUETRÆKKER Screw driver 7 mm t/ fixed clip 1 piece
Product nr. Product Øuantity
MAKITA-PLADESAKS Makita-metal cutter js-1660 1 piece
MAKITA-SIDEKNIV Extra Knife for Makita-metal cutter 1 piece
MAKITA-CENTER KNIV Center Knife for Makita-Metal cutter 1 piece
DRACCO-PLADESAKS Metal cutter Dr ,,co Fb 3514-1 1 piece
DRACCO-OVERKNIV Upper knife Dr,,co metal cutter 1 piece
DRACCO-UNDERKNIV Bottom knife for Dracco-metal cutter 1 piece
Product nr. Product Quantity
KC-30 Endless band/String 30 m
LKS Lock for string/band 50 pieces
Product nr. Product Quantity
TOMMESTOCK 12 piece wooden carpenters ruler 1 piece
TUSCH Marker pen 1 piece
VATERPAS Magnetic carpenters level with stell edges 1 piece
Product nr. Product Quantity
KNIV-STANLEY Large hobby knife with breakable blades 1 piece
KNIV-BLAD Knife blade pack 10 pieces
Product nr. Product Quantity
SPRAY-ZINK Zinc/Alu spray 400 ml
TAPE Duck tape 50 mm roll 50 m
PATENT Patent band 50 m
Accessories