Environics®
Environics®
ISO 9001
Certified
WHAT DOES
ENVIRONICS MANUFACTURE
GAS CALIBRATORS
GAS MIXERS
GAS DILUTORS
REDUCED OXYGEN BREATHING DEVICES
BLENDED GAS ON DEMAND SYSTEMS
HUMIDIFICATION SYSTEMS
ZERO AIR GENERATORS
OZONE SYSTEMS
BENEFITS OF
ENVIRONICS SYSTEMS
Environics accuracy is 10x’s
better than a standard MFC
• +/- 1% of set-point
• Characterization of MFC’s
• Internally stored calibration data
• Linear interpolation
• Nist traceable primary flow
standard
BENEFITS OF
ENVIRONICS SYSTEMS
Generate calibration gas standards from % to
ppb levels
Multi-point calibration at the push of a button.
Produces mixes containing up to 8 individual
component gases in a balance gas.
Generate dilution ratios up to 10,000:1.
Produce custom, user-specified
mixes/dilutions within seconds of start-up
Produce fully NIST traceable mixes/dilutions at
+/- 1% of set-point accuracy.
Exact concentrations on hand at all times
SERIES 6100 MULTI-GAS CALIBRATOR
STANDARD
4x20 LCD DISPLAY
8 INPUT & 8 OUTPUT LINES (STATUS)
RS232 SERIAL COMMUNICATIONS
4 SPAN PORTS
OPTIONS
PHOTOMETER
ADDITIONAL SPAN PORTS
PERMEATION OVEN
3RD MFC FOR INCREASED DILUTION
CAPABILITY
SERIES 6103
OZONE TRANSFER STANDARD &
MULTI-GAS CALIBRATOR
Ambient calibrator
2 MFC based system
Ozone generator
Photometer
RS-232 & status board
Ability to include a 3rd MFC and
permeation
SERIES 6100 & 6103
DISPLAY
• 4 LINE X 20 CHARACTERS
• MENU/PROGRAM USER FRIENDLY
• LCD BACKLIT
• CONTRAST ADJUSTABLE (SOFTWARE)
CHASSIS
• 19” PORTABLE
• INPUTS & OUTPUTS 1/4” STAINLESS
STEEL
• OVERHANG - INPUT PORTS
• WEIGHT 30 LBS.
• 15” w x 7” h x 7.5” d
Zero Air Generator
SERIES 7000
ZERO AIR GENERATOR
Ability to produce up to 20lpm @ 30 psi
Zero air on demand
Internal compressor
Visual dew point indicator
Chassis has complete access for ease of maintenance
Light weight
THC & CO scrubber optional
SERIES 7000
ZERO AIR GENERATOR
VISUAL DEW POINT INDICATOR
Observe the color of the dew point indicator to confirm whether the membrane air dryer is functioning normally.
When dew point indicator color is blue: Functioning normally
When dew point indicator color is pink: Dew point temperature is high (outlet air is moist)*
It takes about 1 hour from the start of air flow for the dew point indicator color to change.
*Note: Atmosphere pressure dew point is approx. -10◦C or more
Series 4000
Gas Mixing System
Series 4040
Gas Dilution System
Environics®
Series 4000/4040 Features
Up to 4 Flow Controllers
Capable of mixing (4000) or
diluting (4040) gases.
Windows® based Instrument Control
• Runs on your PC
Lightweight and portable
Capable of stand alone operation
Low cost
Accurate (+/- 1% of setpoint)
Series 4000/4040 Main Menu
Series 4000/4040 Gas Library
Series 4000/4040 Cylinder Library
Series 4000/4040 Port Configuration
Series 4000/4040 Concentration Mode
Series 4000/4040 Divider Mode
Series 4000/4040 Program Mode
Series 4000/4040 Schedule Mode
Environics Series 2000 family
Series 2000
Multi-Component Gas Mixer
3 MFC’s based system
Capability of 9 MFC’s
Ability to mix up to 8 different
gases with a balance gas
simultaneously
SERIES 2000
ULTRA CLEAN SYSTEM
2 MFC’s based system
Special materials
• Metal seal MFC’s
• 316ss air actuated valves
• Cajon joints & vcr fittings
Continuous purge
SERIES 2020
GAS DILUTION SYSTEM
3 MFC’s based system
Broad dilution range ratios
• 10:1 (2 MFC’s)
• 10,000:1 (5 MFC’s)
Divider mode - 10 step user
specified
SERIES 2014
VOC GAS DILUTION SYSTEM
Standard system includes:
• 3 MFC’s
• Heated flow path
• Purge circuit
Optional
• Humidification
• Canister filling
SERIES 2010
AUTOMOTIVE GAS DIVIDER
Standard automated 10 step
divider
3 MFC based system
Optional: 03 generator
SERIES 2040
GAS MIXER/DILUTION SYSTEM
4 MFC’S based system
Unique capability to mix or dilute
gas
Mix up to 6 gases
Dilute up to 10,000:1
SERIES 9100
AMBIENT CALIBRATION SYSTEM
Calibration of ambient air analyzers
O3 generator
2 MFC based system
Exceeds all U.S. EPA requirements
OPTIONS
Gas Humidification
Canister Filling
Environics HUMIDIFICATION & CANISTER FILLING
Gas Humidification Features
Add specific RH levels to gas
RH level accurate to 5%
Humidity calibration is NIST traceable
Continuous purge path to prevent
moisture build-up and condensation
Humidifier is rear panel mounted
• Operates on gravity feed principle
Gas Humidification Available Options
Fixed humidity level
Adjustable humidity level
Heated gas path for stability
Multiple flow rate calibrations
Canister Filling Features
Allows you to fill a canister with a blend of
gases to a particular pressure.
Software selectable pressure setting (S-2000)
Stops automatically at desired pressure
Change desired pressure even while filling
Actual pressure displayed in real time
Audit trail capability
• Records Start Time, Gas Concentration,
Desired Pressure, Stop Time and Actual
Pressure
Humidification / Canister Filling
Applications
Low level VOC storage
Canister conditioning for VOC
storage
Storage of low level multi-blends
from high level gases
Simulate actual environmental RH
level conditions in lab experiments
Environics®
PERMEATION
PERMEATION DEVICES • DISPOSABLE PERMEATION TUBES
• LIQUID FILLED DEVICES
• GAS FED PERMEATION DEVICES
ENVIRONICS PERMEATION OVENS • PRECISELY CONTROL TEMPERATURE
• ACCURATELY CONTROL FLOW
CREATES VAPOR EMISSIONS
STANDARD PERMEATION OVEN
ULTRA CLEAN PERMEATION OVEN
GAS OUT
PERMEATION GAS IN & OUT
CARRIER GAS IN
GAS FED PERMEATION OVEN
GAS OUT
LIQUID FILL PORT
CARRIER GAS IN
LIQUID FILLED PERMEATION OVEN
WHY PERMEATION?
LOW LEVEL CONCENTRATIONS
GASES NOT AVAILABLE IN
CYLINDERS
EASE OF SHIPMENT
BENEFITS OF
ENVIRONICS PERMEATION
UP TO EIGHT PERM EATION OVENS IN
ONE SYSTEM
CONTINUOUS PURGE
MFC FOR PERM EATION IS NOT
DEDICATED IT CAN BE USED WITH A
CYLINDER WHEN NOT RUNNING THE
PERM EATION OVEN
ACCURACY OF FLOW & TEM PERATURE
PERMEATION APPLICATION
SENSOR DEVELOPMENT - CHEMICAL &
BIO-CHEMICAL WARFARE AGENTS.
ULTRA-CLEAN SYSTEM
PERM. DEVICES - DISPOSABLE & LIQUID
FILLED.
HUMIDIFICATION
Mass Flow Controllers
Diluent Mass Flow Controller
Permea tion Ovens
Temperature Controllers
•Permeation Oven
•Temperature Controller
•Mass Flow Controllers
Inside View
ROBD2
(Reduced Oxygen Breathing Device)
User interface
Embedded computer control
Integrated pulse oximeter
ROBD2
(Reduced Oxygen Breathing Device)
NEW PRODUCTS
GAS HUMIDIFICATION SYSTEM
SERIES 3000 BLENDED GAS ON
DEMAND
ISO 9001: 2000
UL Listed
CE Mark
Top Related