(FOTO) (FOTO)
(FOTO) (FOTO)
(FOTO) (FOTO)
PIN BRAZE, CADWELD 41
Bevel the edges of the plant coating surrounding the Pinbraze.
Roughen the surface of the plant coating surrounding the Pinbraze with an abrasive pad or sand paper. Remove all contaminations.
Degrease with isopropyl alcohol. Do not use a thinner.
12820-04-2020
1 2
3 4
5 6
APPLICATION MANUAL 2020
(FOTO) (FOTO)
(FOTO) (FOTO)
(FOTO) (FOTO)
41
Apply preheated Paste around the Pinbraze and underneath the connecting wire. Check the adhesion of the paste
Fill the area around the Pinbraze with preheated Paste. Avoid air inclusions.
Pre cut a patch of Wrappingband according to the above drawing and place it over the Paste.
12920-04-2020
7 8
9 10
11 12
APPLICATION MANUAL 2020
PIN BRAZE, CADWELD
(FOTO) (FOTO)
(FOTO) (FOTO)
(FOTO) (FOTO)
41
A holiday test using a high voltage tester must be carried out on the green Stopaq Wrappingband prior to the application of any Outerwrap. The test must be carried out at a minimum of 15kV.
Always use approved and certified holiday test equipment.
Apply Outerwrap HTPP with tension over the Wrappingband and avoid air inclusions. Start and finish with an overlap of at least 50mm on plant coating adjacent to the Wrappingband.
13020-04-2020
13
15 16
APPLICATION MANUAL 2020
Use strips of Wrappingband to place the CP cable with loops on the surface.
1817
14
PIN BRAZE, CADWELD
Top Related