Product Catalogue
Intelligent PDUs
7/25/2019 Pdu Mini Catalogo
2/16
Reduce energy costs:
Identify high power consumption
equipment by using logs and port
monitoring
Find opportunities for consolidation
of underutilised equipment such as
near-idle servers
Use environmental monitoring to
identify overcooling situations where
temperatures could be increased for
energy cost reduction
Manage and optimise power
capacity:
Use real-time remote monitoring to
understand usage vs. capacity andmake informed decisions on
equipment additions and data centre
changes
Evaluate actual usage versus
design assumptions (using equipment
nameplate ratings) to understand truepower needs which may help increase
equipment densities
Spot and prevent potential
problems to ensure uptime:
Use alarms to quickly identify
problems and drive resolution sooner
Set alarm thresholds to spot
potential problems such as overloads
that could lead to power loss and
downtime
Use logs to identify erratic power
consumption
Use environmental monitoring to
evaluate planned vs. actual
temperatures to identify areas with
insufficient cooling
Efficiently control power functionsand resolve problems quickly:
Use individual outlet control to
remotely restart equipment or shut
down specific units
Use sequencing to safely start upor shut down equipment and avoid
creating demand spikes
Benets of
Intelligent PDUs
7/25/2019 Pdu Mini Catalogo
3/16
7/25/2019 Pdu Mini Catalogo
4/16
Siemons line of intelligent PDUs
provide valuable energy
consumption data while reliably
delivering power to critical IT
equipment. Each of our PDU
families deliver real-time power
information with varying degrees
of intelligent functionality rangingfrom basic Metered units to
full-featured Managed PDUs -
providing multiple options based
on the level of data and control
requirements.
Siemons intelligent PDUs may beused as stand-alone units, or they
can communicate with third-party
software through common open
networking protocols.
All of our network-capable intelligent
PDUs also have the capacity to
connect environmental sensors,
allowing temperature, airflow, and
humidity to be measured to further
troubleshoot and optimise data centre
efficiency.
PDU Families
Metered
Monitored
Smart
Switched
Managed
Intelligent PDUs
FUNCTION
Built-In Display for Local Use
Device-Level Monitoring
Remote Monitoring via Ethernet Port
Environmental Sensor Ports
Locking Outlets
Outlet-Level MonitoringOutlet-Level Switching/Control
METERED
P
P
MONITORED
P
P
P
P
SMART
P
P
P
P
P
P
7/25/2019 Pdu Mini Catalogo
5/16
Configurations
Various plug inputs
Single and 3-phase voltages
Horizontal and zero-U vertical styles
3m (10 ft.) cords (other lengths available
on requests)
Test data included with each unit
SWITCHED
P
P
P
P
P
P
MANAGED
P
P
P
P
P
P
P
7/25/2019 Pdu Mini Catalogo
6/16
Units have environmental monitoring
capabilities through two RJ12 ports
to support two separately purchased
sensors directly, or up to 16 sensorsconnected via splitters
Metered PDUs provides local visualmonitoring capability through a
built-in LED meter that displays
real-time consumption data.
Metered PDUs are a cost-effective
alternative to monitored or switched
PDUs when remote monitoring is not
desired, while providing a more
intelligent alternative to basic PDUs.
Metered PDUs The 3 phase and 60A units measurecurrent (amps) that scrolls through
each phase
Single-phase PDUs measure power
by scrolling through power factor,
amps, volts and watts
Alarm conditions with high or low
thresholds with notifications via buzzer,
email, or SNMP trap
7/25/2019 Pdu Mini Catalogo
7/16
Remote monitoring is established
via an RJ45 port for network
connection. Data can be
downloaded in PDA, XML andSNMP formats
The LCD display provides the ability
to view power data locally. The
display is customizable for data
type, unit of measure and uniquedevice naming
7/25/2019 Pdu Mini Catalogo
8/16
Monitored and Smart PDUs enable
remote monitoring of power
consumption.
Smart PDUs
Smart PDUs offer the highest level of
monitioring by providing outlet-level
data collection.
Monitored PDUs
Monitored PDUs collect data at an
aggregate, device- level, generating a
smaller quantity of information to
simplify management.
Monitored
and Smart PDUs
Units have environmental monitoring
capabilities through two RJ12 ports
to support two separately purchasedsensors directly, or up to 16 sensors
connected via splitters
7/25/2019 Pdu Mini Catalogo
9/16
Remote monitoring is establishedvia an RJ45 port for network
connection. Data can be downloaded
in PDA, XML and SNMP formats
The LCD display provides the
ability to view power data locally.
The display is customizable fordata type, unit of measure and
unique device naming
7/25/2019 Pdu Mini Catalogo
10/16
Switched and
Managed PDUsIn addition to power monitoring,
switched and managed PDUs
enable users to remotely control
individual receptacles by
allowing equipment to berestarted or remotely shut down.
Switched PDUs
Switched PDUs combine total PDU
power monitoring with port-level
switching. They are the ideal
solution when port control isneeded but only aggregate
consumption data is desired.
Managed PDUs
Managed PDUs offer the highest
level of control and monitoring by
providing outlet-level monitoring
and outlet-level switching.
7/25/2019 Pdu Mini Catalogo
11/16
The LCD display provides the ability to
view power data locally. The display is
customizable for data type, unit of
measure and unique device naming.
User definable URL for each outlet.
Units have environmental monitoring
capabilities through two RJ12 ports to
support two separately purchasedsensors directly, or up to 16 sensors
connected via splitters.
Remote monitoring is established via
an RJ45 port for network connection.
Data can be downloaded in PDA, XML
and SNMP formats.
7/25/2019 Pdu Mini Catalogo
12/16
IntelligentPDU
Software IntroductionThe Intelligent PDUs browser-based softwarecan be accessed through the use of the units
individual IP address.
This can be utilised remotely to access charts, logs,
and alarms and directly interface with the unit toconfigure and define settings, including high or low
thresholds for notifications via buzzer, email, or
SNMP trap. Data can be downloaded in PDA, XML
and SNMP formats.
Scan Here to watch Siemons
full software introduction videoor visit: www.siemon.com/ipdu
7/25/2019 Pdu Mini Catalogo
13/16
Sequential start up
and shut down to
manage loads.
The browser-basedinterface is used to
access charts, logs,
and alarms.
Sensors Page -Delta Configuration.
7/25/2019 Pdu Mini Catalogo
14/16
Specications
General
Safety Compliance
Emissions
Cord Length
Circuit breakers
Outlet Color Coding
Material
Finish
Warranty
Environmental
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Operating Elevation
Storage Elevation
Networking
Networking Protocols
Ethernet Link Speed
Data Formats
CE (International PDUs only)
FCC Part 15 Class A
3m (10 ft.)
30A and higher units
On 3 phase units for load balancing
18 Gauge Steel
Black powder coat
3 Years
-10C to 40C (50 to 104F)
-25C to 65C (-13 to 149F)
5% to 95% (non-condensing)
5% to 95% (non-condensing)
0 to 2000m (0 to 6561ft)
0 to 15240m (0 to 50000ft)
(not applicable to metered units)
HTTP, HTTPS (SSL/TLS), SMTP, POP3, ICMP,
DHCP, TCP/IP, NTP, Telnet, Syslog
10 Mbit; half-duplex
HTML, SNMP, CSV/Plain Text, XML
7/25/2019 Pdu Mini Catalogo
15/16
Mounting
Vertical PDUs mount via tooless
button attachments and include a
mounting bracket for additional flexibility
Horizontal PDUs mount to standard
EIA 19 in. configurations
7ENS-TEMPTemperature Sensor
7ENS-TEMPHAFTemp/ Airflow/ Humidity Sensor
7ENA-SPLIT-5Splitter RJ12 x 5 way
7ENS-WKITWater Sensor Cable
7ENS-WATERWater Sensor
AccessoriesA range of accessories have beendeveloped to support the
application of the Intelligent PDU
solution into varying
environments, each designed
to measure specific sets of datasuch as: humidity, presence of
water, temperature and variations
in airflow.
Mounting
Vertical PDUs mount via tooless
button attachments and include a
mounting bracket for additional flexibility
Horizontal PDUs mount to standard
EIA 19 in. configurations