8/13/2019 Optical Surface Measurements for Very Large Flat Mirrors 2008
http://slidepdf.com/reader/full/optical-surface-measurements-for-very-large-flat-mirrors-2008 1/13
Optical surface measurements for very large flat mirrors
J. H. Burge, P. Su, J. Yellowhair, and C. Zhao
College of Optical Sciences, University of Arizona, Tucson, AZ 85721, USA
ABSTRACT
Flat mirrors as large as 4 meters in diameter can be manufactured to high accuracy, limited bythe surface metrology. We present metrology systems that are specifically optimized for
measuring very large flats to high accuracy. A large aperture vibration insensitive Fizeau
interferometer combined with stitching software provides high resolution surfacemeasurements. Low order shape errors can be measured using scanning slope measurements
from precision inclinometers or an autocollimator with scanning pentaprism.
Keywords: Flat mirrors, optical fabrication, optical testing, large optics
1. INTRODUCTION
High quality flat mirrors that are several meters in diameter have been proposed for use as autocollimating flatsfor system testing and for turning mirrors in giant new telescopes. The production of such mirrors requires new
techniques for optical metrology that are inherently scalable. We have developed three different measurement methods
that are not limited in size and could easily accommodate flat mirrors up to 4 meters across using existing hardware.
The easiest test to implement uses only electronic inclinometers or levels.1 In this test, the levels are placed on the
optical surface to measure the slope. Operating in a differential mode, these measurements can achieve 0.35 µrad slope
accuracy per sampled point, which allows measurement accuracy of only 32 rms power for a 4-m diameter flat. Two-axis levels and dense sampling can be used to provide higher order surface measurements.
A similar slope measurement uses an autocollimator and scanning pentaprism2 to achieve measurement accuracy
of 0.2 µrad, which provides < 50 nm rms power for a 4-m diameter flat mirror. This system has inherent advantagesover the scanning levels because it is non-contact for the optical surface and it can be performed at any orientation.
The highest accuracy measurements can be performed with a vibration insensitive 1-m aperture Fizeau phaseshifting interferometer.3 This system can make measurements with ~ 2 nm accuracy. The data from multiple
subapertures can be combined to give full aperture data for the large flat with < 5 nm rms accuracy. The data from the
subapertures can be combined using a modal maximum likelihood method4, which provides simultaneous calibration ofthe reference flat with the mirror being measured. Alternatively, the subaperture data can be combined using stitching,
which preserves the full resolution of the measurements.5
2. SLOPE MEASUREMENTS
The surface of a flat is unique—the ideal flat mirror has the same slope at all points. We can use this fact formeasuring departures from flatness. If we measure the slope variations accurately, then we can determine the shapeerrors. We use two fundamental references for measuring slope variations – the earth’s gravitational field, and the linear
propagation of light. The systems that utilize these principles are discussed below.
[email protected]; phone 520-621-8182, fax 520-621-3389
Advanced Optical and Mechanical Technologies in Telescopes and Instrumentation, edited by Eli Atad-Ettedgui,Dietrich Lemke, Proc. of SPIE Vol. 7018, 701817, (2008) · 0277-786X/08/$18 · doi: 10.1117/12.790048
Proc. of SPIE Vol. 7018 701817-1
8/13/2019 Optical Surface Measurements for Very Large Flat Mirrors 2008
http://slidepdf.com/reader/full/optical-surface-measurements-for-very-large-flat-mirrors-2008 2/13
C u s t o m b a s ep l a t e w i t h t h r e e
h I f s p h e i t s
R e f e r e n c eS : a n ' i f l 9e ; e I : f : x e o ;l e • ; e I
L a r g e f l a t m i r r o r
( a )
R e f e r e n c e l e v e l
a n n ; l ; : e le a s u r e s Z a n d Z
r / e a s L r e s Z & Z 5 . Z E , Z 7 . Z 8 ,a n d Z l
e a s L r e s 4 , Z 6 . . Z 7 , Z S ,. 1 . a n d Z 1 1 .
S c a n
r r o r
4 fA / 1
2.1 Measurement of slope variation using inclinometers
We use inclinometers, or electronic levels to measure surface slope variations. We modified two high precisionuni-axis electronic levels (Leveltronic made by Wyler AG) to rest on three polished tungsten carbide half-spheres. We
use two levels, a reference B and a scanning level A. We place the reference level B onto the surface and adjust the tilt
of the flat until the absolute level is within 20 arcsec or so. Then we place the scanning level A adjacent to level B andwe set the zero for both levels. The scanning level is moved sequentially across the mirror and the difference between A
and B is recorded. Since the levels measure in one direction, it is important to maintain their alignment. The levels andgeometry are shown in Figure 1.
Figure 1. Electronic levels can be used for measuring surface flatness.
We make a set of measurements across different diameters with the uniaxial levels. We can increase the number of
scans to sample higher order errors and to reduce the noise for the lower order terms. We recognize the value in using
dual-axis levels and sampling the full surface. So far, we have only used the single axis levels. The layouts for the scans
are shown in Figure 2.
Figure 2. Scan layout for single axis and dual axis scans.
Single axis levels, linear scans
Dual axis levels, general scans
Proc. of SPIE Vol. 7018 701817-2
8/13/2019 Optical Surface Measurements for Very Large Flat Mirrors 2008
http://slidepdf.com/reader/full/optical-surface-measurements-for-very-large-flat-mirrors-2008 3/13
The accuracy of the measurements with the electronic levels is quite good. A detailed analysis is presented
elsewhere1 and summarized here. The dominant error in the measurements comes from noise in the levels themselves.
The effect of the noise can be reduced by averaging. The slope errors for the system at the University of Arizona are
listed in Table 1.
Table 1. Error analysis for flat measurement with E-levels
Error source ExplanationValue(rad)
Noise in the levels and calibration Determined from repeatability experiments 0.25
Drift due to environment This is monitored and kept to 0.10 µrad by re-sampling a
reference point
0.10
Axes coupling (guide rail) Random variations of the scanning e-level orientation
couple with the absolute tilt of the flat.
0.13
Levels placement and setting Random position errors couple with the mirror slope 0.01
Software fit error (residual) High frequency surface errors are not fully sampled 0.13
Gravity Local gravity variation 0.10
Total error (root sum square) 0.34
A least squares fit is used to determine the low order shape errors as represented by Zernike polynomials using the
slope data. A Monte Carlo simulation of three line scans, as shown in Figure 2c, with 12 measurements per scan was
performed assuming 0.34 µrad variation per measurement (0.48 µrad for a differential measurement). The results for a 2-
m mirror show overall accuracy of 50 nm rms overall and only 16 nm rms power. This result would scale linearly with
mirror diameter, so a 4-m mirror can be measured to 32 nm rms power.
Table 2. Measurement accuracy for 2-m flat mirror from Monte Carlo simulation with 0.34 µrad error per measurement
Aberration Zernike Gradient Measurementaccuracy (nm rms)
Power Z4 = 2( x
2
+ y
2
) – 1 4 x î + 4 y 16
Z5 = ( x2 – y2) 2 x î – 2 y 29Astigmatism
Z6 = 2 xy 2 y î + 2 x 29
Z7 = 3( x3 + xy2) – 2 x (9 x2 + 3 y2 – 2) î + 6 xy 11Coma
Z8 = 3( x2y + y3) – 2 y 6 xy î + (3 x2 + 9 y2 – 2) 11
Spherical Z9 = 6( x4 + y4) – 6( x2 + y2) + 1 12 x(2 x2 – 1) î + 12 y(2 y2 – 1) 8
RSS 50
The advantage of the e-level measurement is obviously the low cost. However, this test is cumbersome to perform and it cannot be used on coated optics without risking damage to the coatings. We have pursued a more
accurate, optical version of this test that uses an electronic autocollimator and pentaprisms.
Proc. of SPIE Vol. 7018 701817-3
8/13/2019 Optical Surface Measurements for Very Large Flat Mirrors 2008
http://slidepdf.com/reader/full/optical-surface-measurements-for-very-large-flat-mirrors-2008 4/13
2.2 Measurement of slope variation using autocollimator with scanning pentaprism
The shape of the flat mirror can be sampled with a scanning pentaprism2,6 system, such as that shown in Figure 3.
This technique scans the beam from an autocollimator across the pupil using a pentaprism. Slope variations aremeasured and integrated to give the profile along the line of the measurement. Multiple scans can be made to build up a
full surface. This test has been proven at the University of Arizona where a 1.6-m diameter flat mirror was measured to
12 nm rms.2 This simple system achieves such high accuracy by taking advantage of a special property of the pentaprism – the light is deviated by an angle, nominally 90°, which is completely insensitive to tilt of the prism itself.
Thus no additional reference is required. Data from a 1.6-m flat mirror are shown in Figure 4.
Scanning Pentaprism Test
• Two pentaprisms are co-aligned to a high resolution autocollimator
• The beam is deviated by 90 to the test surface
• Any additional deflection in the return beam is a direct measure of surface slope changes
• Electronically controlled shutters are used to select the reference path or the test path• One prism remains fixed (reference) while the other scans across the mirror
• A second autocollimator (UDT)
maintains angular alignment of
the scanning prism through an
active feedback control
Shutters
Autocollimator system
Fixed prism
(reference )
Scanning
prism
Feedback
mirror
Mechanical
supports
Coupling
wedge
ELCOMAT
(Measuring AC)
UDT
(Alignment AC)
Shutters
Autocollimator system
Fixed prism
(reference )
Scanning
prism
Feedback
mirror
Mechanical
supports
Coupling
wedge
ELCOMAT
(Measuring AC)
UDT
(Alignment AC)
1
Figure 3. Scanning pentaprism measurement for large flat mirrors.
This test achieves very high accuracy using a high performance autocollimator and utilizing the weak sensitivity ofmeasurement errors to systematic error in the alignment. The dominant error comes from the 0.2 µrad noise that arises
from air motion in the lab. The effects of alignment and geometry are limited to 0.02 µrad rms, as shown in Tables 3 and4. This accuracy is achieved even though the prisms themselves and all of the static and dynamic alignment terms areallowed to be 1000 times larger than this.
Proc. of SPIE Vol. 7018 701817-4
8/13/2019 Optical Surface Measurements for Very Large Flat Mirrors 2008
http://slidepdf.com/reader/full/optical-surface-measurements-for-very-large-flat-mirrors-2008 5/13
M e e s u r e d S l o p e D e t a W i t h Z e m l k e P o P y l l o m l e l F I t1 0 0 0
8 0 0
6 0 0
4 0 0
2 0 0
' :- 6 0 0 f
- 8 0 0
- 1 0 0 O
r a d i u s ( n o r m a l i z e d )
0 s l o p e d a t a
I
Figure 4. Data from University of Arizona scanning pentaprism measurement of 1.6-m flat.9
Table 3. Sources of error for UA scanning pentaprism system
Parameter Description Tolerance
PP
Initial misalignment of the
prism roll< 0.13 mrad
PP Variation in prism roll < 0.05 mrad rms
AC
Misalignment of the
autocollimator roll relative todirection of motion
< 0.10 mrad
AC Variation in autocollimator roll < 0.05 mrad rms
PPInitial misalignment of the
prism yaw< 0.13 mrad
PP Variation in prism yaw < 0.05 mrad rms
Table 4. Effect of errors on slope measurement
ContributionLine of sight
deviation (nrad rms)
2 PP PP 13
AC PP 7
AC PP 7
AC PP 5
AC PP 5
RSS 18
Analysis of scanning pentaprism measurements were made for the TMT tertiary mirror 7. This large flat has anelliptical shape 3.5 x 2.5 meters. We evaluate the performance of the scanning pentaprism system for determining the
lowest order shape errors in the flat, power and astigmatism, shown in Table 5.
Measurement of M3 with the scanning pentaprism system was simulated, including the data reduction. A Monte-
Carlo simulation was run to see the uncertainty in determining the first three modes of the mirror: mostly astigmatism
and power. The pentaprism test was modeled with a random Gaussian distribution with standard deviation of 0.2 µrad.The data was then fit to the first three modes. 100 Monte-Carlo runs were performed and statistics of the fitted
coefficients of the three modes and the residual were calculated. Table 5 lists the results. Higher order modes haveincreased slope variation per µm of surface height, so they can be measured more accurately than power andastigmatism, but only if enough scans are made to fully sample them. With 0.2 µrad rms noise and multiple scans, each
mode can be determined to < 20 nm rms.
Proc. of SPIE Vol. 7018 701817-5
8/13/2019 Optical Surface Measurements for Very Large Flat Mirrors 2008
http://slidepdf.com/reader/full/optical-surface-measurements-for-very-large-flat-mirrors-2008 6/13
S U U S I I I 5 - l - 0 5 0 U - U U U U U
S L a o . . S o c . . - & r : . O d c S . f l S a f l m E i 1 a L . . 1 b
( a )
i . £ b 0 L 0 L i . J .
l l . - — 1 —
—
- i
— — —
I
— — — — — — — — — — — — — — — — — — .
( a )
- Z . 8 - Z . 6 - 0 . J 2 0 0 2 Z . 4 Z . 6 a e
Table 5. Results of 100 Monte-Carlo simulations of the pentaprism measurements of the 3.5 x 2.5-m TMT tertiary mirror
with 0.2rad measurement uncertainty is per point. The resulting error for each of the low order modes is given.
Mode 1: 20 nm rms Mode 2 : 24 nm rms Mode 3: 9 nm rms
We have presented two slope measurement methods. We measured the same surface with both techniques and
found the agreement to be exceptional. The raw slope data and the calculated surface shape are presented for both casesin Figure 5.
Figure 5. The same surface measured with the electronic levels and the scanning pentaprism system produce virtually
identical results.
Proc. of SPIE Vol. 7018 701817-6
8/13/2019 Optical Surface Measurements for Very Large Flat Mirrors 2008
http://slidepdf.com/reader/full/optical-surface-measurements-for-very-large-flat-mirrors-2008 7/13
3. SUBAPERTURE INTERFEROMETRY WITH STITCHING SOFTWARE
3.1 Fizeau interferometry
Large optics can be measured efficiently with subaperture Fizeau interferometry. The data from the subaperture
measurements can be stitched together to give full surface maps. There are two key technical issues with this method:
efficiency and accuracy. The test configuration is shown Figure 1
The Fizeau interferometer uses reflection from a reference surface that is held only a few mm from the surface
being measured. The reflection from the reference surface is interfered with light reflected from the surface under test,and the difference between the two reflected wavefronts is used for the measurement. Phase shifting interferometry can
be performed by either pushing the reference plate with PZT piezoelectric transducers or by using a simultaneous phaseshifting interferometer that uses polarization to separate the reflections.
The simultaneous phase shifting interferometer uses two beams with orthogonal polarization with some tilt
difference. These two are each reflected from the reference surface and from the surface under test. By setting therelative tilts for the optics, one can select the reference and test beam with appropriate orthogonal polarizations. Then
the phase shifting is performed using polarization optics to create 3 or 4 interferograms that have 90° relative phase shift
and can be read out simultaneously. The wavefront phase is then calculated from the set of interferograms. This freezes
out the effect of vibration. Commercially available systems that can be used in this mode are produced by ESDI and 4DTechnologies.
As long as the physical separation is small, then the effects of imperfect wavefronts due to limitations in the
illumination optics and the test plate glass do not significantly affect the measurement. The analysis for such errors is
given by Burge8. Also, the effect of birefringence in the test plate has been shown to have negligible effect for the
simultaneous phase shifting interferometers as long as circular polarization is used.
9
The use of a standard vibration insensitive Fizeau interferometer with the remote test plate was demonstrated for1-m aperture measurements.10 This system used the H-1000 instantaneous Fizeau system from ESDI and included an
off-axis parabola for illumination. Measurements achieve a noise level of 3 nm rms over the 1-m aperture.
Mirror Under Test
1 m reference flat
LHC
(B)
RHC
(A)
Alignment mode
Software screen
Spots from the
test surface
Spots from the
reference surface A B
A BPolarizationInstantaneousinterferometer
IlluminationOptic
Figure 6. Layout of Fizeau test for subaperture interferometric measurement
Proc. of SPIE Vol. 7018 701817-7
8/13/2019 Optical Surface Measurements for Very Large Flat Mirrors 2008
http://slidepdf.com/reader/full/optical-surface-measurements-for-very-large-flat-mirrors-2008 8/13
3.2 Subaperture stitching
Software is used to combine, or stitch, the data from the subapertures to create a full aperture map. Stitching istypically a least-squares type of process where the relative alignment degrees of freedom are determined based on the
consistency of the different measurements. There are two different types of stitching algorithms, those that concentrate
on the overlap regions4, 11, and those that solve for more global consistency.5 They have both been proven to work to thenoise limit. For this project, we have written software that solves for the tip, tilt, and piston of each map in order to
optimize the data consistency in the overlap regions. For the case of the secondary mirror, power for each subaperturewas determined as well.
The software was tested with some examples and shown to be quite robust. The noise sensitivity for the
individual measurements is presented separately for the cases of the secondary mirror and tertiary mirror. This softwarewas never carefully optimized for this application. It would not be difficult to develop software that has slightly better
noise rejection, but the gains will be marginal.
The basic algorithm was taken from a paper by Otsubo et al.4 The software was written in MATLAB, whose powerful matrix manipulation functions are taken advantage of. Little effort was devoted to better memory management
or improving calculation speed. Test cases were used to verify the accuracy of the software.
The algorithm is briefly described here:
A full-aperture map and valid data mask was created using synthetic data.
Each sub-aperture map has the same matrix size and valid data was masked by its own mask and the full-aperture mask.
Sub-aperture masks determined the overlapped area.
In the overlapped area, average was taken from the fitted sub-aperture data, which was done by adding up the
masks to determine how many sub-apertures cover a specific pixel.
The least squares algorithm described above was used to solve for the alignment degrees of freedom to
minimize the difference between the measurements in the overlap region.
The stitched full-aperture map can be decomposed into Zernike polynomials and the residual is calculated after
Zernike decomposition.
Interference
occurs here
Requires 8 subaperture measurementsto get complete coverage
1.6 m test flat
1 m (8)
subapertures
Large flat miror
1 m reference flat
Rotary air bearing table
Large flat miror
1 m reference flat
Rotary air bearing table
1
Figure 7. A large flat mirror can be fully measured by measuring subapertures. The test accuracy and efficiency areimproved with larger subapertures.
Proc. of SPIE Vol. 7018 701817-8
8/13/2019 Optical Surface Measurements for Very Large Flat Mirrors 2008
http://slidepdf.com/reader/full/optical-surface-measurements-for-very-large-flat-mirrors-2008 9/13
3.3 Demonstration of Fizeau with subaperture stitching
The University of Arizona has successfully developed the world’s largest vibration insensitive phase shiftingFizeau interferometer.12 This uses a 1-m transmission flat, and is capable of measuring to < 3 nm rms over the 1-m
diameter. The geometry for this system is shown in Figure 8 and the details for the reference flat support are shown in
Figure 10.
We developed software for calibrating the subaperture Fizeau test using the ensemble of data we obtain from
rotating both the measurement mirror and the reference mirror. This maximum likelihood approach was used to provide
the shape errors for both parts for the 1-m reference and the 1.6-m mirror under test.5 The comparison between the fullresolution stitching and the modal reconstruction is excellent.
Large flat miror
1 m reference flat
H1000 Fizeau
interferometer
Fold flat
1 m illumination OAP
Rotary air bearing table
Large flat miror
1 m reference flat
H1000 Fizeau
interferometer
Fold flat
1 m illumination OAP
Rotary air bearing table
1
Figure 8. The University of Arizona has developed a large phase shifting Fizeau test for measuring a 1.6-m flat mirror.
By rotating both flats, we were able to calibrate all of the errors except power. Power was measured with the scanning
pentaprism system.
Proc. of SPIE Vol. 7018 701817-9
8/13/2019 Optical Surface Measurements for Very Large Flat Mirrors 2008
http://slidepdf.com/reader/full/optical-surface-measurements-for-very-large-flat-mirrors-2008 10/13
4 - .
C — t
1
8 0
8 0
4 0
2 0
- 2 0
- 4 0
- 8 0
- 8 0
- I O U
' . m E
Figure 9. Data from a 1.6-m flat mirror were reduced two different ways, modally where the modal coefficients are
optimized to provide consistency with the data and by direct stitching where the individual maps are used directly, with
adjustments in tilt and piston.
Figure 10. The 1-m reference flat is supported at the edge with counterweight offloading.
We require hardware modifications to enable the measurement of the larger flat mirrors. The subaperture
measurements must be made at two radial positions to cover the full mirror. The figure below shows how we canaccomplish this for measuring a 2.7-m flat mirror, moving the test hardware between measurements.
Flat Surface by Stit ching Method - power/astigmatism removed
100 200 300 400 500 600 700 800
100
200
300
400
500
600
700
800
6 nm rms after removing power & astigmatism 7 nm rms after removing power & astigmatism
[P. Su] [R. Spowl]
Reconstruction by stitchingModal reconstruction
Bonded pucksand attached
cables
Reference flat
Uppersupport
Test flat
Polishing table
184 nm PV42 nm RMS
Reference Flat Surface measurement
(nm)
Reference Flat FEA
129 nm PV29 nm RMS
(nm)7559432711-6-22-38
Proc. of SPIE Vol. 7018 701817-10
8/13/2019 Optical Surface Measurements for Very Large Flat Mirrors 2008
http://slidepdf.com/reader/full/optical-surface-measurements-for-very-large-flat-mirrors-2008 11/13
- 2 . 6 - 2 - 1 . 6 - l - 0 . 6 0 0 . 6 1 . 6 2 2 . 6
Figure 11. Fizeau measurement of a 2.7-m flat mirror. The optical test system will be moved to two different
locations for the testing of two radial positions. At each position, the 2.65-m mirror is rotated 360°.
We studied the case of using 1m diameter reference mirror for sub-aperture measurements of the elliptical TMT
flat mirror (M3). A total of 19 measurements are needed to cover the whole surface. Figure 12 shows the sub-aperture
distribution assumed for this analysis.
Figure 12. Sub-aperture distributions for the test of the 3.5m x 2.5m TMT elliptical flat mirror M3. The subaperturemeasurements are 1 meter in diameter.
An example of the stitching simulation is shown in Figure 13. An additional 50 Monte Carlo simulations were
run and the full-aperture map was stitched from the 19 sub-aperture measurements each of which has correlated noise of
3 nm. In the simulations, we used 100x100 pixels for each sub-aperture and 250x350 pixels for the full M3 aperture. The
actual matrix for the full-aperture map is 350x350 pixels. The stitched maps were fitted to the 10 modes of M3. The
uncertainties of the fitted coefficients of the 10 modes are shown in Figure 14.
Proc. of SPIE Vol. 7018 701817-11
8/13/2019 Optical Surface Measurements for Very Large Flat Mirrors 2008
http://slidepdf.com/reader/full/optical-surface-measurements-for-very-large-flat-mirrors-2008 12/13
U
/
I
U
iI
a
1\ 1 i ' . ) . * _ _ Ia
L &I
a Y • E
' a ' .
. \ S J .
M3 Subaperture example: 3nm M3 stitched map: 6.4nm rms
M3 low order error from fitting: 3.8nm rms M3 residual from fit: 5.2nm rms.
(3 nm rms after removing global tilt)
Figure 13. An example of stitched map of sub-aperture measurements with 3nm rms noise. This causes an error in the
low order terms of 3.8 nm rms. After removing these terms, the residual noise is about 3 nm rms.
Mode 12.9 nm rms
Mode 22.4 nm rms
Mode 31.4 nm rms
Mode 41.1 nm rms
Mode 51.4 nm rms
Mode 60.8 nm rms
Mode 70.8 nm rms
Mode 80.8 nm rms
Mode 90.5 nm rms
Mode 100.8 nm rms RSS for all modes:
4.6 nm rmsResidual fromfitting all modes3 nm rms
Figure 14. The uncertainties of the fitted modes and the residual of the stitched map obtained from 50 M-C simulations
with 3 nm rms noise per subaperture.
Proc. of SPIE Vol. 7018 701817-12
8/13/2019 Optical Surface Measurements for Very Large Flat Mirrors 2008
http://slidepdf.com/reader/full/optical-surface-measurements-for-very-large-flat-mirrors-2008 13/13
4. CONCLUSION
Until recently, the possibility of a giant flat mirror, many meters in diameter, was unthinkable. The University ofArizona has developed and implemented flat mirror metrology methods that have been proven on a 1.6-m mirror, and are
directly scalable to mirrors that are many meters across. This measurement capability, coupled with the proven
techniques of large tool grinding and computer controlled polishing enable the University of Arizona to manufacture flat
mirrors as large as 4 meters with proven equipment.
REFERENCES
1) J. Yellowhair, J. H. Burge, “Measurement of optical flatness using electronic levels,” Optical Engineering 47 (2),
023604 (2008).
2) J. Yellowhair and J. H. Burge, "Analysis of a scanning pentaprism system for measurements of large flat mirrors,"Appl. Opt. 46, 8466-8474 (2007).
3) C. Zhao, RA Sprowl, M Bray, JH Burge, “Figure measurement of a large optical flat with a Fizeau interferometer
and stitching technique,” in Interferometry XIII , edited by E. Novak, W. Osten, C. Gorecki, Proc. of SPIE 6293,
62930K, (2006).4) M. Otsubo, K. Okada, J Tsujiuchi, “Measurement of large plane surface shapes by connecting small aperture
interferograms,” Optical Engineering, 33 (2), 608-613, (1994).
5) P. Su, J.H. Burge, R. Sprowl, J. Sasian, “Maximum Likelihood Estimation as a General Method of Combining Sub-
Aperture Data for Interferometric Testing,” in International Optical Design Conference 2006, Proc. SPIE 6342
(2006).
6) P. C. V. Mallik, C. Zhao, J. H. Burge, “Measurement of a 2-meter flat using a pentaprism scanning system,” Optical
Engineering 46 (2), 023602 (2007).
7) Blanco, D. et al ., 2006, “Control & Support of 4-meter class secondary and tertiary mirrors for the Thirty Meter
Telescope”, in Optomechanical Technologies for Astronomy, Eli Atad-Ettedgui, Joseph Antebi and Dietrich Lemke,editors, Proc. SPIE 6273, (2006).
8) J. H. Burge, “Fizeau interferometry for large convex surfaces,” in Optical Manufacturing and Testing , V. J. Doherty
and H. P. Stahl, Editors, Proc. SPIE 2536, 127-138 (1995).9) C. Zhao, D. Kang, and J. Burge, “Effects of birefringence on Fizeau interferometry that uses a polarization phase-
shifting technique,” Applied Optics 44, 7548-7553 (2005).
10) C. Zhao, R.A. Sprowl, M. Bray, J.H. Burge, “Figure measurement of a large optical flat with a Fizeau interferometerand stitching technique,” in Interferometry XIII , edited by E. Novak, W. Osten, C. Gorecki, Proc. of SPIE 6293,
62930K, (2006).
11) M. Bray, “Stitching interferometer for large plano optics using a standard interferometer”, in Optical Manufacturing
and Testing II , ed. H. P. Stahl, Proc. SPIE 3134, 39-50. (1997).
12) J. Yellowhair, P. Su, M. Novak, J. Burge, “Fabrication and testing of large flats,” in Optical Manufacturing and
Testing VII , ed. by J. Burge, O. Faehnle, and R. Williamson, Proc. SPIE 6671, (2007).
Top Related