The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
1
Carl BisaillonOPAL-RT
Power Hardware-In-the-Loop (PHIL)
Optic Fiber ORION Protocol
Gernot PammerEGSTON
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
2
Workshop plan
EGSTON COMPISO solution presentationo Introduction of EGSTONo Description of the COMPISOo Benefits & Features of the COMPISO
Join Hands-on Demonstratono Power Hardware-In-the-Loop with COMPISO through ORION Optic Fiber protocol
OPAL-RT presentationo Introduction of partnership with EGSTONo OP4500 product and PHIL ORION solutiono Benefits, Features and Accomplishments on the PHIL with COMPISO
OPAL-RT road mapo Future for OPAL-RT and EGSTON in their partnership
Q&A
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
3
HQ, Sales, R&D
Production Facilities
Local sales teams
Employees
Sales 2013
Certification
Austria (Eggenburg, Vienna)
Czech Republic, China, India
Germany, China, India
1.035
€ 44.5 Millions
ISO 9001 ISO/TS 16949
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
4
Products & Applications
Cable SystemsInductive Components
Power SuppliesAutomotive Components
medical equipment
chargers
sanitarian applications
security applications
stroke magnets/solenoids
coils for elektric drives
sensor coils
antenna coils
transformers & chokes
power supplies for industrial
applications
white goods
telecom industry
robots
construction machinery
machines for agriculture
cranes
railway vehicles
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
5
Products & Applications (March 2014)
Power Electronics
COMPISOUltra Compact Bidirectional Multi Purpose Inverter
with Sinusodial Output
Digital Amplifiers
DC-DC Converters
DC-AC Converters
DC-AC Drive Inverters
Converter Components
Converter System
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
6
Ultra Compact Bidirectional Multi Purpose Inverter with Sinusoidal Output
WHAT IS COMPISO ?
COMPISO
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
7
COMPISO digital amplifier
…0010100101010…
Digital Input Signal
Analogue Output Signal10µs
Processing Delay
4 QuadrantOutput
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
8
Transfer Function – No load
10 kHz-1 dB
10 kHz-25°
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
9
Transfer Function – RL = 3 Ω
10 kHz-1 to -3 dB
10 kHz-40 to -48 °
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
10
3-Phase Amplitude Output Voltage
Full span (400VRMS)
up to 5 kHz
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
11
• Digital Amplifier
• Extremely low ripple (< 0.15% VIN)
• Full span output voltage (400 VRMS) up to 5 kHz
• Signal bandwidth: 10kHz / -3 dB
• Extremely high output dynamics
(load jump 10% to 90% < 100µsec)
• Low signal transport & processing latency: 10µsec
COMPISO Summary
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
12
• Standard Buck-Boost Converter
• COMPISO Converter6-leg step-up / step down converter withcoupled inductors
COMPISO Features - Converter
VOUT
IIN
IOUTL
C
C
=
=
Z
S
S
VIN
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
13
• Ripple Graph• VDC_LINK=800V & IOUT=100A
COMPISO Features - Ripple
• Ripple Theory
Best case
Min (3)
Worst case
Max (4)
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
14
• Modules• DC-DC Converter
• POUT=120kW, IOUT=±150ADC, VOUT = 800VDC
• Single-phase AC-DC Converter• SOUT= 40kVA, IOUT=±126ARMS, VOUT= 400VRMS
• Power Rack = 3 Converters• DC-DC Converters (360kW)
• AC-DC Converters (120kVA)
• Cascading• DC Mode: IOUT = 150 to 1.500 ADC
• AC Mode: IOUT = 126 to 1.260 ARMS
COMPISO Features - Modules
19“
8 H
UC PR
C PM 1
C PM 2
C PM 3
C PR
C PM 1
C PM 2
C PM 3
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
15
• UDP-Link• Standard 100 Mbps optical Ethernet
• Asynchronous Package Transfer
• Parametrization
• Status information
• RT-Link (ORION by OPAL-RT)• High Speed optical interface
• Synchronous Package Transfer
• Send Set Points in real-time to COMPISO
• Receive measurement values (Voltage, Current) from COMPISO
COMPISO Interface Types
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
16
• Control Modes• Raw Duty Cycle (Active Damping)
• Voltage Control
• Current Control
• Signal Sources• Internal
• Arbitrary Waveform Generator
• External• RT-Link (ORION)
• UDP-Link
COMPISO Control ModesCPM
UDP
AWFG
RT-Link
V
A
Current controller
Active damping
Voltage controller
Vint
Iint
VDC link
CPM Power Path
CPM Internal Controller
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
17
• Set Point Generator• External RT Controller
• HIL
• Inner Closed Loop• Voltage Control
• Current Control
COMPISO Closed Loop – Inner Loop Mode
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
18
• Set Point Generator• External RT Controller
• HIL
• Inner Closed Loop• Raw Duty Cycle Active Damping
• Outer Closed Loop• Control Loop implemented in
RT-Controller / HIL
COMPISO Closed Loop – Outer Loop Mode
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
19
• Set Point Generator• External RT Controller
• HIL
• Inner Closed Loop• Voltage Control
• Outer Closed Loop• Control Loop implemented in
RT-Controller / HIL
• Current Control
COMPISO Closed Loop – Cascaded Loop Mode
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
20
PHIL hands-on demonstration
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
21
• OP4500• Simulated distribution grid
(residential model)
• Voltage source with harmonics
• Fault breakers on grid
• A PHIL load in simulatedneighbourhood
• ORION protocol by Optic Fiber
• Load measurement by Ain (Closed-loop)
PHIL demonstration architecture
To Be connected to
the 13th house as a
Hardware Under Test
Simulated Part
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
22
• PHIL Architecture• COMPISO System
• Real load
• OP4500 target
• External Measurement (CT&VT)
• GUI• RT-LAB (TestDrive)
• EGSTON GUI SCADA
PHIL hands-on demonstration architecture
DC
AC 3~
50/ 60 Hz
C OM PIS O
A C G R ID
DC
AC 3~
50/ 60 Hz
C OM PIS O
A C G R ID
D C
A C 3 ~
5 0 / 6 0 H z
C OM PIS O
A C G R ID
DC
AC
C OM PIS O
A C Inve r t e r
DC
AC
C OM PIS O
A C Inve r t e rT R A N S F OR M E R
e
5 0 / 6 0 H z
G r id
~~
~
C ir c u it
B r e a ke r
COMPISO Power Conversion System
A C - D C D e vic e
U nd e r T e s tM e a s u r e m e nt
D C
A C / D C
C OM PIS O
D ig it a l A m p
V D C
A
V~
C ONT R OL
GU I
U D P- Link
S w it c h
R T - Link
E G S T ON G U I
S C A D A
C ONT R OL
GU I
H a r d w a r e In
t h e Loop
G U I
H IL
(R T - C ont r olle r )
D r ive r
Pr oc e s s or
Power Rating – Cascaded Systems
Input Voltage range 560 VAC,RMS
Power (Basic) 120 kW
Power (Cas 2) 240 kW
Power (Cas 3) 360 kW
Power (Cas 4) 480 kW
Power (Cas 5) 600 kW
Power (Cas 6) 720 kW
Power (Cas 7) 840 kW
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
23
• Load voltage from OP4500 to COMPISO by Optic Fiber• Grid measured voltage 220 Vrms
• COMPISO generates voltage• Hardware unipolar voltage 60 Vpk
• Current tranformer for measurement• Hardware current 2 Apk
• Load current from hardware to OP4500 by Ain• Current injected in grid 14 Arms
• Load seen by simulated grid• Active power of 3 kW
Demonstration & Results
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
24
• Close-loop system may becomeunstable under certain condition
• Instability caused by delays maydamage equipment and reduceprecision
PHIL Stability Analysis• Stability depends on:
• Ratio of load power over short-circuit power of the feeder
• Type of load• Damping of source impedance• Power amplifier bandwidth• Simulator’s sampling frequency• Use of current feedback filter
PHIL simulation equivalent circuit
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
25
• Instability caused by the interaction of:• Lsource (linear gain with a phase of −𝜋
2)
• L//R filter and voltage amplifier (Limit gain, add phase lag)
• IO time delay (add linear phase lag)
• Type of load (Higher power, higher gain)• Resistive (No phase effect)• Inductive (Reduce Lsource phase & gain)• Capacitive (Increase Lsource phase & gain)
• Current feedback filter (Limit gain at fc)
PHIL Stability Analysis+
-
)(sFsource
sTe
1 )(sFampli
2
1
Z
2I
bI1
1V
aI1 )(sF filtersT
e 2
sT
Filteramplisource
b
a esFsFsFZsI
sIsF .
21
1 )()()(1
)(
)()(
sss
s
ssL
ZsF
filterampliLR 1
1
1
1
1
1
1
1.
1)(
2
CwjZ
12 wjLZ 22 22 RZ
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
26
• Bode Diagram• Stability becomes gain dependent
when phase reaches 0
• Maximum stable load (ga𝑖𝑛 ≤ 1), determines max load power
• Lower sample time increases the simulation stability and accuracy
• Cut all frequencies beyond a phase gain of -π
PHIL Stability Analysis Conclusions
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
27
• Xeon E3 4 cores processor up to 3.3Ghz
• Xilinx Kintex-7 FPGA
• CPU model sample time down to 7µs
• FPGA chip sample time down to 250ns
• 4 optional 2-Gbits SFP optical interface
• 64 DIO with 50ns latency
• 32 fast analog converters (16-bit precision)
OP4500
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
28
• A design by Antoine Keirsbulck (FPGA and Driver Team Leader at OPAL-RT)
• Low-speed digital communication protocol
• Baud rate 25 MHz
• Manchester Coder/Decoder
• Requires the 126-0509 LVDS to fiber optic adapter
• EGSTON applicationo Message time intervals of 4µso 1 command header word and 3 data words
PHIL ORION Protocol – Opal Remote IO Network
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
29
• Permits transmission over a safedistance without distorsion in highpower environment
• High speed signal transmission
• ORION is an open access protocol• Spec available on demand
• Simple wiring
Benefits, features and accomplishments
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
30
• University of Padua• 3-phase PHIL
• 30-60 kW system
Future for OPAL-RT and EGSTON
The 7th International Conferenceon Real-Time Simulation TechnologiesMontreal | 9-12 June, 2014
31
Questions and Contacts
Carl Bisaillon, Eng. Jr.Application [email protected]: 1-514-935-2323 ext 357Fax: 1-514-935-4994