Next Generation Air/Ground CommunicationsNext Generation Air/Ground Communications
(NEXCOM) Program(NEXCOM) ProgramPresented to
Airborne Internet Collaboration GroupReston VA
April 17, 2003
Dieter ThigpenIntegrated Product Team for Communications
Federal Aviation Administration
2
What is NEXCOM? Next Generation Air/Ground Communications
• FAA’s program to modernize and improve VHF air/ground communications in the National Airspace System (NAS)– Fundamental change from analog to digital technology
• VHF Digital Link Mode 3 (VDL-3)– Time Division Multiple Access Technology– Maintains current 25 kHz frequency separation, but – Provides 4 non-interfering channels on 1 frequency– All channels suitable for voice or data
– Operates in the 118-137 MHz band allocated for Air Traffic use
• Impacts both ground and airborne elements of the NAS
3
National Airspace System (NAS)Transition to Digital Communications
Dem/ValDem/Val
• Analog Voice, 25 KHz
• Full Operational Evaluation& Exercise of Digital Voiceand Datalink (VDL-3)
Next 5 years
AnalogVoice
5-10 years
• Maintain Terminal Analog Voice
• Implement VDL-3Digital Voice
Enroute High Airspace
National Airspace
RCAGARTCC
VDL-3Link
10-15 years
• Expand EnrouteDigital Voice (VDL-3)
• Initiate TerminalDigital Voice (VDL-3)
• Increase Datalink Capacity& Capability (VDL-3)
TerminalAirspace
15-20 years
• Expand Digital Voice (VDL-3) to all domains
• Expand Datalink Capacityin all domainsand all applications(VDL-3)
AFSS
4
• VHF and UHF ATC bands• Approximately 10,000 VHF
assignments• Approximately 50,000 VHF &
UHF TX, RX & TCVRs• Dedicated networks for each
operational environment• Limited restoral capabilities• Limited remote maintenance
capability
NAS Air/Ground Communications Infrastructure Components
61 AFSSs, 14 FSSs Automated Flight Service Stations, Flight Service Stations
21 ARTCCs & 3 CERAPsAir Route Traffic Control Center,Combined Center Radar Approach Control
793 RCAGsRemote Communications Air/Ground
1854 RCOsRemote
Communications Outlet
175 TRACONsTerminal Radar Approach Control
1422 RTRsRemote Transmitter Receiver
346AirportTowers
720 BUECsBack up Emergency
Communications
5
National Airspace System Environments
Typical System Handoff:
Preflight into Departure: Tower hands off to TRACON; TRACON hands off to En Route System.
Departure, En Route, Descent into Approach: ARTCCs, AFSSs and Remote Comm Facilities (RCAG, RCO, RTR, BUEC) hand off to each other and eventually back to a TRACON. That Approach TRACON will handoff to the destination Tower.
Terminal Environment Terminal EnvironmentEn Route
Terminal: D
epartu
re
Terminal: Destination
RCFs
RCFs
RCFs
RCFs
RCFs
RCFs
AFSS
As long as aircraft is below 10,000 ft
From when aircraft returns to 12,000 ft
6
NEXCOM Acquisition Program Elements
Multimode Digital Radio
Analog & digital
Ground System
System Demo Program
NEXCOM architecture & commercial avionics
Digital capability forvoice and data
VHF T/R
RIUGNI
Avionics
Analog & digital
7
NEXCOMAcquisition Program Elements
Multimode Digital Radio (MDR)• Compatible with today’s radios
– Double Side Band-AM 25 kHz
– 8.33 kHz
– VDL Mode3
– Interfaces to the future NEXCOM Ground System
• Replaces current NAS ITT & Motorola CM200 radios– Initial use is replacement of aging radio infrastructure
• Contract Awarded July 01 to ITT; Base Year with 9 Options• Operational testing at Key Site complete Fall 02
• Further operational testing at second key site Fall 03
• Radio deployment begins early 2004
8
NEXCOM Acquisition Program Elements
Ground System Segment
• Components• Radio Interface Unit (RIU)
– Provides capability for digital communications
• Ground Network Interface (GNI)
– Provides connectivity for voice switches
• Two-Phase Development• Rapid Preliminary Development Effort (RPDE) (Mar 02-Dec 04)
– ITT and Harris Teams selected as vendors in Feb 03
• Full Scale Development Program (FSDP) (Jan 05-Dec 07)– Only RPDE vendors compete
VHF T/RRadio
InterfaceUnit
GroundNetworkInterface
9
NEXCOM Acquisition Program Elements
Avionics • Components
• Multimode VHF radio• Radio Control Panel• Communications Management Unit (optional)
• FAA/Manufacturer Agreements signed Dec 01• Rockwell Collins, Honeywell – airlines• Avidyne – general aviation• Pending agreement – business jets
• Agreements include cost sharing and payable events
• Pre-production models to be used in System Demo II (Fall 03)
• Goal is certified avionics commercially available in 2005
10
NEXCOM Acquisition Program Elements
System Demonstration Program• Series of three demonstrations
– Fall 02, Fall 03 at FAA Tech Center• Demo 1 was very successful• Participants included NATCA controllers and pilots
– Fall 04 at an operational site
• Objectives– Fall 02: VDL Mode 3 Technology viability– Fall 03: NEXCOM Architecture feasibility
• Vendors provide pre-production avionics– Fall 04: Operational suitability
• Commercial avionics
11
NEXCOM Schedule
2001 2003 2004 200920052002 2006 2007 2008
System DemoProgram
10/03SystemDemo II
10/04OperationalDemo
10/02SystemDemo I
MultimodeDigitalRadio 7/01
Contract Award
MDR deployment
3/04Notice ofAvailability TSO
9/03AEECApprovedChar.
Avionics8/04
CertifiedAircraft
10/01MOPS
10/02Strawman
CharacteristicsComplete
01/10Operational
6/05-12/09 Aircraft equip
10/01Sys Reqs
Doc
2/03RPDEContract Awards
1/05Full Scale Dev Contract Award
Validation & Inter-Operability Tests
10/07Keysite
12/01GIAs
04/04Begin
Deployment
8-11/02Ops
Testing
GroundSystem
07-12 Implementation
12
Technical Slides
Back Up Slides
13
Spectrum Requirements GrowthC
irc
uit
s (
10
00
s)
5
10
15
20
25
1998 2003 2008 2013 2018 2023 2028Year
Increasing Cost and Difficulty of Provisioning New Circuits
Historically, circuit growth Averages 4% per year.
Increasing cost/difficulty ofplacing new circuitsreduces growth rate
Reduced growth rate implies less-efficient NAS.
Growth in A/G Circuit Demand
23 spectrum recovery initiatives
(ASR)
• Growth in channel demand is based on # of flights, not passenger growth
• Channel demand must meet peak flight period demand, not average demand
Unsatisfied DemandReduces NAS Efficiency
# DeployedA/G Circuits
14
Typical TDMA Frame FormatConfigurations
* Slot devoted entirely as Management Subchannel
A DCB
TDMA Frame 120 ms
4V
3TDis
cret
e A
ddre
ssed
Voi
cean
d D
ata
Voi
ce O
nly
Voice VoiceVoiceVoice
3V1D DataVoiceVoiceVoice
2V2D Voice DataDataVoice
*Voice/Data
Voice/Data
Voice/Data
User GroupsSupported
Services toEach Group
4
N/A
2
3Dedicated Voice
w/Shared Data Slot
Demand AssignedVoice and Data
(Trunked)
Dedicated Voiceand Data
Dedicated VoiceOnly
15
VDL-3 Channel Structure
= 120 ms “TDMA frame” is the fundamental timing framework= Each slot contains two independent “bursts” = M bursts are used for channel management; while V/D
bursts are used for voice or data transfers
4-slot Configurations
Time slotA
Time slotB
Time slotC
Time slotD
30 ms slot
ManagementSubchannel
Voice/DataSubchannel
TDMA Frame (120 ms)
16
• Frequency range 118–137 MHz• Channelization 25 kHz centers• Channel structure Same frequency for uplink and downlink• Radio range* 200 nmi for 4-slot configurations
600 nmi for 3-slot configurations• Symbol rate 10.5 kbaud (3 bits /symbol) • Modulation Differential 8-ary Phase Shift Keying
(D8PSK) • Access technique Time Division Multiple Access (TDMA)• Voice encoding 4.8 kbps (Normal Voice)
4.0 kbps encoding (Truncated Voice) • Data Functionally simultaneous with voice
* Range takes into consideration of propagation delay and timing errors of the aircraft radios only
NEXCOMVDL 3 CHARACTERISTICS
17
Summary
• The NEXCOM system is currently under development and projected Initial Operational Capability by end of 2009.
• NEXCOM is implementing a Command and Control Link (CCL). (There is no requirement to deliver wide bandwidth applications)
• Internet Protocol (IP) would require international (International Civil Aviation Organization) and national (Radio Technical Commission for Aeronautics Inc.) certification for use as an Air Traffic Control CCL.
• VDL Mode 3 has operated with Internet Protocol (IPv4) using the CLNP (ConnectionLess Network Protocol) interface at the WJHTC. FAA has not validated IPv4.
18
Acronyms
AEEC Airlines Electronics Engineering Committee NOA Notice of AvailabilityARTCC Air Route Traffic Control Center NPRM Notice of Proposed RulemakingASP Acquisition Strategy Paper OEP Operational Evolution PlanBUEC Back Up Emergency Communications OTA Other Transaction AuthorityCA Contract Award RCAG Remote Communications Air/GroundCERAP Combined Center Radar Approach Control RCO Remote Communications OutletCSMA Carrier Sense Multiple Access RTR Remote Transmitter ReceiverDLAP Data Link Application Processor RPDE Rapid Preliminary Development EffortFAT Factory Acceptance Test RIU Radio Interface UnitFSDP Full Scale Development Program SAT Site Acceptance TestGNI Ground Network Interface SC Special CommitteeICAO International Civil Aviation Organization SIR Screening Information RequestIOC Initial Operational Capability SRD System Requirements DocumentIPP Integrated Program Plan STC Supplemental Type CertificateISD In-Service Decision TDMA Time Division Multiple AccessJRC Joint Resource Council TSO Technical Standard OrderMDR Multi-Mode Digital Radio TSOA Technical Standard Order AuthorizationMOPS Minimum Operational Performance Standards VDL VHF Digital Link
Top Related