heat pumps
MODERN
R290PROPANE
heatpumps
MODERN
High quality is a core area of HKS LAZAR strat-
egy: from the design, manufacture until
maintenance service.
Top quality
All components are delivered by reputable suppliers
Strict quality control at any phase of production.
Automatic operation.
Extraordinary noise reduction.
Compatible with Internet.
Colour control touch panel.
Cascade heat pumps operation possible
Two heating circuits, and extension possible.
Compatible with wireless thermostat.
Hot water circulation
One of the main priorities for HKS LAZAR is client’s satisfaction.
Comfort
Unique designSome design options available.
A wide range of finish available: exotic wood, com-
posite wood, polycarbonate, architectural concrete.
Different design options available upon request.
Caring for the natural environment is one of the pri-
ority mission HKS LAZAR, that is why our heat
pumps operate on the natural refrigerant R290
(propane). This gas is neutral to the ozone layer
and has a negligible global warming potential
of GWP = 3 (for comparison, the GWP of the
most popular refrigerant R410A is 2088). This is
undoubtedly a great relief for our environment.
However, users will also benefit from having a heat
pump running on R290. There is no obligation to register this
type of equipment and to pay for emissions*. And supple-
menting the losses of R290 is much cheaper, given the rapid
increase in f-gases prices related to the progressive restric-
tions in their production and use. Above all there is no concern
about the necessity to withdraw our pump from use, as it may
be in the case of pumps operating on fluorinated gases (f-gas-
es, eg R410A).
Natural refrigerant R290 (propane)
EfficiencyVery high COP up to 4.78.
No registration or gas-emission fees*.
Wide operation range – prevents use
of other heat sources.
Professional license not required for
installation*.
Programmable weekly operation.
Temperature control.
EcologyCarbon-free heating.
Renewable heat source.
Ozone-friendly R290 gas (ODP=0) that features with low global warming
impact (GWP =3).
* - depends on local laws
Uniquedesign
ASAnthracite | Silver
AAAnthracite | Anthracite
AWCAnthracite | Composite
wood
AWIAnthracite | Iroco exotic
wood
ACAnthracite | Architectural
concrete
GCGrey |
Architectural concrete
GWCGrey | Composite
wood
GSGrey | Silver
GGGrey | Grey
GWIGrey | Iroco exotic
wood
Water heating up to 62ºC
Absorbs heat from the outside air
High efficiency
Natural refrigerant – R 290
Operation at outside temperature down to -25ºC
High COP up to 4.78
Module with an internal heater
High heating output
It limits the work of the additional heat source
Big evaporator
11,5 kW - 22,2 kWPower:
HT 10heat pump
Module with a heaterThe HT10 heat pump with an internal module
for the water or glycol system consists of
an outdoor unit, an indoor unit and a commu-
nication cable.
SCOP3,899
The contents of the internal module:
controller, installation, electric heater.
The HT10 heat pump is equipped with an advanced ecoNET300 communication module as standard, which enables remote pump operation, servicing, viewing the history of parameter changes and sending e-mail messages with alarms.
PC
TB
TCWU
T1, T2
H1
G1, G2
B1
O1
O2
PO1
PO2
PO3
ZT
ZC
ZW1, ZW2
ZM1
ZB1/ZB2
Heat pump
Buffer temperature sensor
DHW tank temperature sensor
Heating circuit temperature sensor
Indoor module with heater
Heaters
Heat buffer
Heating circuit 1
Heating circuit 2
Top source pump
Circuit pump 2
Circuit pump 3
Three-way valve
DHW tank
Non-return valve
Mixing valve 1
Safety valveM
O1 O2T1 T2
PO2 PO3
ZM1
ZW2B1 TB
ZB2
ZW1H1
G2
ZT
PO1
G1
ZB1
ZC
TCWU
PC
Hot water circuit
Cold water circuit
DISTRIBUTOR
The outdoor unit is a monobloc heating pump
made of the highest quality components and
a modern cooling system manufactured in ac-
cordance with COCH module A2 accreditation,
which guarantees the highest quality and safety.
The indoor unit includes a controller that gives
the user many possibilities, electric installation
and auxiliary electric heater.
The units are connected by the supplied com-
munication cable and the hydraulic system.
Control module with heater
Water heating up to 62ºC
Absorbs heat from the outside air
High efficiency
Natural refrigerant – R 290
Operation at outside temperature down to -25ºC
High COP up to 4.78
Internal Smart Module
High heating output
It limits the work of the additional heat source
Big evaporator
11,5 kW - 22,2 kWPower:
HT 10heat pump
Module SmartHT10 heat pump with Smart indoor module for
water or glycol circuit. In this configuration,
the HT10 heat pump consists of an outdoor unit,
a Smart indoor unit and a communication cable.
The contents of the Smart indoor module:
controller, installation, electric heater,
CH/DHW switching valve, circuit pump.
The HT10 heat pump is equipped with an advanced ecoNET300 communication module as standard, which enables remote pump operation, servicing, viewing the history of parameter changes and sending e-mail messages with alarms.
SCOP3,899
PC
G1
B1
O1
O2
TB
TCWU
T1, T2
HK2
P02
P03
ZC
ZM1
ZB1
Heat Pump
Heater
Heat buffer
Heating circuit 1
Heating circuit 2
Buffer temperature sensor
DHW tank temperature sensor
Temperature sensor of the heating circuit
Internal Smart Module
Circuit pump 2
Circuit pump 3
DHW tank
Mixing valve 1
Safety valve
The outdoor unit is a monoblock heating pump
made of the highest quality components and
a modern refrigeration system manufactured in
accordance with COCH module A2 accreditation,
which guarantees the highest quality and safety.
The Smart indoor unit includes a controller
that gives the user many possibilities, an electri-
cal installation, an auxiliary electric heater and
a hydraulic system with a CH/DHW switching
valve.
The units are connected by the supplied com-
munication cable and the hydraulic system.
Smartcontrolmodule
O1 O2T1 T2
PO2 PO3
ZM1
TBB1
G1
HK2
ZB1
ZC
TCWU
PC
Hot water circuit
Cold water circuit
DISTRIBUTOR
Water heating up to 62ºC
Absorbs heat from the outside air
High efficiency
Natural refrigerant – R 290
Operation at outside temperature down to -25ºC
Internal SmartSplit Module
Big evaporator
High heating output
It limits the work of the additional heat source
High COP up to 4.78
11,5 kW - 22,2 kWPower:
HT 10heat pump
Anti-Freeze Module SmartSplitHT10 heat pump with SmartSplit indoor module
for water / glycol circuit consists of outdoor
unit, SmartSplit indoor unit and communication
cable.
The contents of the SmartSplit indoor module:
controller, installation, electric heater,
CH/DHW switching valve, plate exchanger, CH
circuit pump, PC circuit pump, glycol circuit
expansion vessel.
The HT10 heat pump is equipped with an advanced ecoNET300 communication module as standard, which enables remote pump operation, servicing, viewing the history of parameter changes and sending e-mail messages with alarms.
SCOP3,899
PC
G1
B1
O1
O2
TB
TCWU
T1, T2
HK2
PO2
PO3
ZC
ZM1
ZB1
Heat Pump
Heater
Heat buffer
Heating circuit 1
Heating circuit 2
Buffer temperature sensor
DHW tank temperature sensor
Temperature sensor of the heating circuit
Internal Smart Split Module
Circuit pump 2
Circuit pump 3
DHW tank
Mixing valve 1
Safety valve
The outdoor unit is a monobloc heating pump
made of the highest quality components and
a modern cooling system manufactured in accord-
ance with COCH module A2 accreditation, which
guarantees the highest quality and safety.
The SmartSplit indoor unit includes a con-
troller that gives the user many possibilities,
electrical installation, auxiliary electric heater,
CH/DHW switching valve and a hydraulic system
separating the external and internal installation.
As a result, the installation outside the building
can be filled with glycol to protect it against
freezing, while the installation inside the build-
ing can be filled with water.
The units are connected with the supplied com-
munication cable and the hydraulic system.SmartSplit Anti-Freeze Control Module
O1 O2T1 T2
PO2 PO3
ZM1
TBB1
G1
HK2
ZB1
ZC
TCWU
PC
Cold water circuit
Hot water circuit
Glycol
DISTRIBUTOR
Product card
Special precautions when assem-
bling, installing or maintaining the
heat pump. Observe all assembly, in-
stallation and maintenance require-
ments in the device’s instruction
manual.
POWER / COP A7 / W35:
POWER / COP A7 / W65:
POWER / COP A2 / W35:
POWER / COP A-7 / W35:
POWER / COP A-15 / W35:
POWER / COP A-15 / W55:
Communication cable:
Working temperature range:
Maximum flow temperature:
Refrigerant amount:
Power:
Weight:
Dimensions:
Hydraulic connection:
Indoor module with 2-9 kW flow heater:
Internal Smart Module:
Internal SmartSplit Module:
11,5 kW / 4,78
10,1 kW / 2,75
9,1 kW / 4,0
7,1 kW / 3,0
6,1 kW / 2,64
5,7 kW / 1,76
YES
-25ºC ÷ 35ºC
62 ºC
2,0 kg
3x400 V lub 1~230 V
180kg
810 x 1380 x 810
G5/4
YES
14,1 kW
12,8 kW
13,2 kW
9,7 kW
7,5 kW
7 kW
YES
-25ºC ÷ 35ºC
62 ºC
2,1 kg
3x400 V lub 1~230 V
180kg
810 x 1380 x 810
G5/4
YES
17,7 kW
15 kW
15,3 kW
11,3 kW
8,7 kW
8,3 kW
YES
-25ºC ÷ 35ºC
62 ºC
2,2 kg
3 x 400 V
185kg
810 x 1380 x 810
G5/4
YES
22,2 kW
18,8 kW
19,2 kW
14,2 kW
11 kW
10,2 kW
YES
-25ºC ÷ 35ºC
62 ºC
2,4 kg
3 x 400 V
190kg
810 x 1380 x 810
G5/4
YES
HT 10 / 12 HT 10 / 14 HT 10 / 16 HT 10 / 20
ENERGY EF. CLASSPOWER [COOL CLIMATE]
POWER [TEMPERATE CLIMATE]POWER [WARM CLIMATE]
ηs [COOL CLIMETE]ηs [TEMPERATE CLIMATE]
HT 10 / 12A++
10kW12kW14kW134%155%
HT 10 / 14A++
12kW14kW16kW135%154%
HT 10 / 16A++
14kW16kW20kW136%153%
HT 10 / 20A++
16kW20kW22kW135%154%
ηs [WARM CLIMATE]
Qhe [COOL CLIMETE]
Qhe [TEMPERATE CLIMATE]
Qhe [WARM CLIMATE]
LWA
HT 10 / 12180%
4883 kWh
4192 kWh
3620 kWh
54 dB
HT 10 / 14178%
4892 kWh
4208 kWh
3632 kWh
54 dB
HT 10 / 16175%
4558 kWh
4235 kWh
3780 kWh
54 dB
HT 10 / 20170%
4576 kWh
4235 kWh
3874 kWh
54 dB
Special precautions when assem-
bling, installing or maintaining
the heat pump: Observe all as-
sembly, installation and mainte-
nance requirements in the equip-
ment manual.
* - depending on the heat pump model
*
Tanks
NOMINAL CAPACITYMAXIMUM TEMPERATURE AND
OPERATING PRESSURE OF THE TANKINSULATION
WEIGHTENERGY CLASS
TB01 / 200200
66C
TB01 / 300 TB01 / 500300
PUR85C
500
108C
TB01 / 400 TB01 / 600400
101C
600
Removable124C
TB01 / 800800
165C
95ºC / 3 Bar
Special precautions for assembly,
installation or maintenance of the
buffer tank: All installation, installa-
tion and maintenance requirements
contained in the device’s instruction
manual must be observed.
NOMINAL CAPACITYSPIRO COIL – SURFACESPIRO COIL – CAPACITY
SPIRO COIL MAXIMUM WORKING TEMP. AND PRESSIRE
WATER TANK MAXIMUM WORKING TEMP. AND PRESSURE
INSULATIONWEIGHT
OPTIONAL ELECTRIC HEATING ELEMENT
ENERGY CLASS
NOMINAL CAPACITYSPIRO COIL – SURFACESPIRO COIL – CAPACITY
LOWER COIL – SURFACELOWER COIL – CAPACITY
SPIRO COIL MAXIMUM WORKING TEMP. AND PRESSIRE
COIL MAXIMUM WORKING TEMP. AND PRESSIRE
WATER TANK MAXIMUM WORKING TEMP. AND PRESSURE
INSULATIONWEIGHT
OPTIONAL ELECTRIC HEATING ELEMENT
ENERGY CLASS
TH02 / 300 HH02 / 800 / 5 / 2,8TH02 / 500 / 5 TH02 / 800 / 53004,018
116
C
8005,0232,814,3
95ºC / 6 Bar
95ºC / 6 Bar
95ºC / 3 Bar Removable
237G.K.2,0(6/4) / G.K.4,5(6/4) / G.K.6,0(6/4)
G.K.9,0(6/4) / G.K.12 (6/4) C
5005,023
126
C
8005,023
Removable180
C
95ºC / 6 Bar
G.K.2,0(6/4) / G.K.4,5(6/4) / G.K.6,0(6/4) G.K.9,0(6/4)
G.K.12 (6/4)-
95ºC / 3 Bar
PUR
Special precautions for assembly, installation or maintenance of the hygienic water heater tank: All installation, installation and maintenance requirements contained in the device’s instruction manual must be observed.
without a coilbuffer tanks
They are used to store energy. Polyurethane foam insulation,
leatherette housing.
hygienic water heatertanks
They are used to store energy and produce DHW water using a corrugated
stainless steel coil. Polyurethane foam insulation, leatherette housing.
MIX 3D
pump group with mixing
Distributors and pump groups
pump group without mixing
distributor
It facilitates and accelerates the execution of the
heating system, precisely regulates the supply tem-
perature, includes a circuit pump, a mixing valve
with an actuator, all built in aesthetic isolation.
without mixing
pump group
It is designed to pump the medium in the heat-
ing installation, facilitates installation, includes
a circuit pump, all built in aesthetic insulation.
2 or 3 circuits
distributor
It facilitates the assembly of pump groups, saves
time, space and installation costs. Made of steel
with polypropylene insulation to reduce heat
loss.
pump group with mixing MIX 3D
Thanks to its compact design and small dimensions, it will perfectly fit
into undeveloped, narrow spaces of the attic.
Use the space
The simplicity of the control mod-
ule, the ease of use of the touch
panel and the possibility of using a
mobile application make our device
user-friendly.
Innowacyjny system kontroli przepływu
powietrza pozwala zwiększyć sprawność
układu nawet o 30%. Wentylatory dosto-
sowują prędkość do aktualnych warunków
pracy, utrzymując zrównoważony bilans stru-
mieni powietrza nawiewanego i wywiewanego.
Be in control
The sound source is suppressed at the place where it
is generated, which makes our air handling units quiet
and efficient. An insulation technology in which closed-
cell, waterproof foam also acts as thermal and acoustic
insulation. The exposed surface absorbs the sound wave
and prevents it from being reflected.
Forget about him
Compatible with HT10 heat pump
Two-stage M5 class filters allow to obtain 40% higher
quality of filtered air compared to standard G3 and
G4 class cartridges. The actual dirty filter system
shows you when to replace the filters.
Feel the freshness
When outside temperatures are below freezing,
freezing moisture blocks the air flow. AR 10 equipped
with an anti-freeze system enables balanced ventila-
tion regardless of weather conditions.
Frost does not scare us
The new heat exchangers maintain an exchange effi-
ciency of 90%, which reduces the annual heating cost
by 30%.
High efficiencyOn cool summer evenings, you can safely bypass the
heat exchanger and enjoy the cool, clean air in the
building.
Take care of the climate
The innovative air flow control system allows you to increase
the efficiency of the system by up to 30%. The fans adjust
their speed to the current operating conditions, maintain-
ing a balanced balance of supply and exhaust air streams.
Balance is the basis
recuperationMODERN
One controller panel
One common indoor setpoint temperature
Automatic compatibility of operating modes
One common Internet System
Diagram of an example installation:
The modern AR 10 dispels doubts!Thanks to its compact design and small dimensions , it will perfectly fit into undeveloped, nar-
row spaces of the attic. The innovative air flow control system allows you to increase the efficiency of the system by up to 30%.
RECUPERATOR
AR 10
Air stream
Maximum heat recovery efficiency
Average annual recovery efficiency
Sound power levelat maximum efficiency
Heat exchanger
Fans
Filters
Power
Maximum current consumed by the device
Dimensions
Weight
Connection stubs
Work temp
SEC – specific energy consumption [kwh/m2/year]:
SEC class:
cool-71,82
A+
temperate-35,63
A
warm-12,27
E
Declared device type:Drive type:
Type of heat recovery system:Thermal efficiency of heat recovery [%]:
The maximum value of the air flow rate [m3/h]:Maximum fan power consumption [W]:
Sound power level [dB(A)]:
BidirectionalStepless fan speed controlDiaphragmatic88%30710050
Flow rate reference value [m3/h]:Pressure difference reference value [Pa]:
Unit power consumption [W(m3/h)]:Control type factor and control type:
Declared maximum internal and external air leakage coefficients [%]:Location and description of the visual warning before replacing the air filter:
Website with assembly instructions:
220500,32CRS = 0,85 MISC = 1,1Internal 2,1%, External 1,9%Control panelwww.hkslazar.com
AEC – annual electricity consumption [kWh/year]:
AHS – annual heating savings [kWh/year]:
cool890
8850
temperate445
4540
warm400
2060
305 m3 / h (100 Pa)
95,00 %
90,00 %
52 dB
Recair with increased efficiency, 100% countercurrent
Centrifugal with EC motors
Filter class orwat M5
230 V / 50 Hz
5,9 A
1122 / 556 / 735 mm
65 kg
200 mm
+0 do +45ºC
We deliver safe, energy-efficientand eco-friendly products WWW.HKSLAZAR.COM
An exemplary diagram of a recuperation installation:
heat pumps
MODERN
HKS LAZAR Spółka z o. o.
44-335 Jastrzębie-Zdrójul. Wodzisławska 15B POLAND
+48 32 47 57 123 | +48 32 47 29 578 | +48 32 47 51 960
WWW.HKSLAZAR.COM