Download - ML145 - Flomotion SystemsELECTROMAGNETIC FLOWMETER ML145 BATTERY or SOLAR POWERED CONVERTER FOR ISOMAG ELECTROMAGNETIC FLOWMETERS For use in remote locations or sites with unreliable

Transcript
Page 1: ML145 - Flomotion SystemsELECTROMAGNETIC FLOWMETER ML145 BATTERY or SOLAR POWERED CONVERTER FOR ISOMAG ELECTROMAGNETIC FLOWMETERS For use in remote locations or sites with unreliable

ELE

CT

RO

MA

GN

ET

IC F

LOW

ME

TE

R

ML145BATTERY or SOLAR POWERED CONVERTERFOR ISOMAG ELECTROMAGNETIC FLOWMETERSFor use in remote locations or sites with unreliable power

• Simpleone-buttondisplayofvariousmeasurementparameters

• Poweredbyinternallithiumbatteriesand/orexternalDC(solarpanelorpowersupply)

• Internalbatteriestakeoverifexternalpowerfails

• CompatiblewithallISOMAGflowsensorsupto32”

• Bi-directionalflowmeasurement• Emptypipedetection• Internal2GBdatalogger• PowerToolsoftwareestimatesbattery

life• ISOCONsoftwareforprogramming

anddataretrieval

ML145 FEATURES

Accuracy 0.5%

Mounting Sensor or Remote

Keypad 1 Key

LCD Display 2-Line x 16 Character Alphanumeric (no backlight)

Sensor Size Up to 32” (800mm)

4-20mA Output Y (External Power only)

Pulse/Frequency / Alarm Output

2 Assignable Open Collector

Empty Pipe Detection Yes

Programming Interface

MS Windows PC with USB interface

Datalogger Yes (2GB)

Power Supply Up to 6 Lithium BatteriesExternal Power: 10-30VDC

Power Consumption 0.08W with Batteries0.2W(3Wmax) with External

DC Power or Solar Panel

Protection Rating NEMA 6

Minimum Conductivity 20 uS

Temperature Range -4 to 140F

ML145 SPECIFICATIONS

Page 2: ML145 - Flomotion SystemsELECTROMAGNETIC FLOWMETER ML145 BATTERY or SOLAR POWERED CONVERTER FOR ISOMAG ELECTROMAGNETIC FLOWMETERS For use in remote locations or sites with unreliable

FLOMOTION SYSTEMS Inc.165CreeksideDrive,Suite112BuffaloNY14228Tel:716-691-3941Fax:716-691-1253Email:[email protected]

© COPYRIGHT 2014 FLOMOTION SYSTEMS INC. PGS CS2 110314

FLOMOTION ML145 DIMENSIONS

6.7”

6.7”

5.8”

6.4”5.8”

9.1”