www.labec.com.au
Laboratory Equipment Pty Ltdemail: [email protected] Ph: 02 9560 2811 • Fax: 02 9560 6131
Serv
ing
the
Scie
ntifi
c, M
edic
al a
nd R
esea
rch
indu
stri
es s
ince
194
5
2014
Milk Analyzers
M-MIA-SLC / Standard Low Cost Milk Analyzer
M-MIA-S / Standard Milk Analyzer
LABEC Milk Analyzers are user-friendly, rapid analysers which can be applied for measurement of fat (FAT), solids non-fat (SNF), density, proteins, lactose, salts, water content percentages, temperature (°C), freezing point, pH, conductivity, as well as total solids directly after milking, at collecting stage and during processing.
Model M-MIA-SLCMeasuring time Measuring parameters Standard complete Additional options
90 Sec
FAT: 0.01% ~ 25%SNF: 3% ~ 15%Density: 1015 ~1040kg/m3Proteins: 2% ~ 7%Lactose: 0.01% ~ 6%Water content: 0% ~ 70%Temp. of milk: 1°C ~ 40°CFreezing point: -0.400°C ~ 0.700°CSolids: 0.4 – 1.5%
1. Sample visualization on LED display2. Possibility to measure 1 sample - 90 seconds3. Adapter 220-110 V4. Spare silicone tubes5. Syringe6. Plastic sample holder7. Calibrations Cow, Sheep, and UHT milk8. Operation Manual9. Cardboard transport case10. CD – Service pack
NoAdditional
options
ModelMeasuring time Measuring parameters Standard complete Additional options
Ph Option
Conductivity
M-MIA-S
60 Sec
FAT: 0.01% ~ 25%SNF: 3% ~ 15%Density: 1015 ~ 1040kg/m3Proteins: 2% ~ 7%Lactose: 0.01% ~ 6%Water content: 0% ~ 70%Temp. of milk: 1°C ~ 40°CFreezing point: -0.400°C ~ 0.700°CSolids: 0.4 ~ 1.5%
1. Sample visualization on LCD display(green)2. Possibility to measure 1 sample – 90 seconds (option 60 seconds)3. Adapter 220-110 V4. Spare silicone tubes 5. Syringe6. Plastic sample holder7. Calibrations Cow, Sheep, and UHT milk8. Operation Manual9. Cardboard transport case10. CD – Service Pack
High Fat 45% (High Density)
90 Sec
M-MIA-SLC M-MIA-S
www.labec.com.au
Laboratory Equipment Pty Ltdemail: [email protected] Ph: 02 9560 2811 • Fax: 02 9560 6131
Serv
ing
the
Scie
ntifi
c, M
edic
al a
nd R
esea
rch
indu
stri
es s
ince
194
5
2014
SPECIFICATIONS Milk Analyzers
Environmental conditions:• Ambient air temperature: 10°C ~ 40°C (option 43°C) • Milk temperature: 1°C ~ 40°C • Relative humidity: 30% ~ 80%
ElEctrical ParamEtErs: • AC Power Supply voltage: 220V/110VDC • Power Supply voltage: 12V to 14,2V • Power Consumption: 30W max.
mEchanical ParamEtErs: • Dimensions: W290 x D300 x H330mm • Weight: < 5 kg
• Embedded printer. • Embedded keypad. • Integrated weight scales. • Additional serial printer. • Matrix printer (option). • External keypad (option).
Features:• Peristaltic pump – automatic cleaning. • Knee-joint (mobile) input pipe. • Adjustable to the input pipe pH probe holder. • Possibility of using different sample holders. • Integrated pH and conductivity measuring. • Self calibration without computer.
M-MIA-A / Standard Automatic Milk Analyzer
M-MIA-CC / Milk Collecting Centre
Model M-MIA-AMeasuring time Measuring parameters Standard complete Additional options
Ph Option
Conductivity
60 Sec
FAT: 0.01% ~ 25% (option 45%)SNF: 3% ~ 15%Density: 1015 ~ 1040kg/m3 (1160 kg/m3 option)Proteins: 2% ~ 7%Lactose: 0.01% ~ 6%Water content: 0% ~ 70%Temp. of milk: 1°C ~ 40°CFreezing point: -0.400°C ~ 0.700°C
1. Sample visualization on LCD display2. Possibility to measure 1 sample – 90 seconds (option 50 seconds)3. Adapter 220-110 V4. Peristaltic pump 5. Spare silicone tubes6. Syringe7. Plastic sample holder8. Calibrations Cow, Sheep and UHT milk9. Operation Manual10. Cardboard transport case11. CD – Service pack
High Fat 45% (High Density)
90 Sec
Model M-MIA-CCMeasuring time Measuring parameters Standard complete Additional options
Ph Option
Conductivity
Integrated scales
Accumulator with charger
Real time clock
Remote display
High Fat 45% (High Density)
1. Sample visualization on LCD display2. Possibility to measure1 sample – 50 seconds (option 30 seconds)3. Adapter 220-110 V 4. Peristaltic pump 5. Spare silicone tubes 6. Syringe7. Plastic sample holder 8. Calibrations Cow, Sheep, and UHT milk 9. Operation Manual 10. Cardboard transport case11. CD – Service pack
FAT: 0.01% ~ 25% (option 45 %) SNF: 3% ~ 15%Density: 1015 ~ 1040kg/m3 (1160kg/m3 option)Proteins: 2% ~ 7%Lactose: 0.01% ~ 6%Water content: 0% ~ 70% Temp. of milk: 1°C ~ 40°C Freezing point: -0.400°C ~ 0.700°C Solids: 0.4 ~ 1.5%
30 Sec
50 Sec
www.labec.com.au
Laboratory Equipment Pty Ltdemail: [email protected] Ph: 02 9560 2811 • Fax: 02 9560 6131
Serv
ing
the
Scie
ntifi
c, M
edic
al a
nd R
esea
rch
indu
stri
es s
ince
194
5
2014
SPECIFICATIONS Milk Analyzers
Features:• Peristaltic pump – automatic cleaning. • Knee-joint (mobile) input pipe. • Adjustable to the input pipe pH probe holder. • Possibility of using different sample holders. • Possibility of connecting pH probe. • Integrated pH and conductivity measuring. • Self calibration without computer.
Environmental conditions:• Ambient air temperature: 10°C ~ 40°C (option 43°C) • Milk temperature: 1°C ~ 40°C • Relative humidity: 30% ~ 80%
ElEctrical ParamEtErs: • AC Power Supply voltage: 220V/110VDC • Power Supply voltage: 12V to 14,2V • Power Consumption: 30W max.
mEchanical ParamEtErs: • Dimensions: W250 x D290 x H330mm • Weight: < 4 kg
M-MIA-LA
M-MIA-LA / Laboratory Automatic Milk Analyzer
Model M-MIA-LAMeasuring time Measuring parameters Standard complete Additional options
Ph Option
Conductivity
Integrated scales
Accumulator with charger
Real time clock
Remote display
High Fat 45% (High Density)
1. Sample visualization on LCD display2. Possibility to measure1 sample – 50 seconds (option 30 seconds)3. Adapter 220-110 V 4. Peristaltic pump 5. Spare silicone tubes 6. Syringe7. Plastic sample holder 8. Calibrations Cow, Sheep, and UHT milk 9. Operation Manual 10. Cardboard transport case11. CD – Service pack
FAT: 0.01% ~ 25% (option 45 %) SNF: 3% ~ 15%Density: 1015 ~ 1040kg/m3 (1160kg/m3 option)Proteins: 2% ~ 7%Lactose: 0.01% ~ 6%Water content: 0% ~ 70% Temp. of milk: 1°C ~ 40°C Freezing point: -0.400°C ~ 0.700°C Solids: 0.4 ~ 1.5%
30 Sec
50 Sec
Key features:• User-friendly, simple in operation, maintenance,
calibration and installation.• Portable and compact design. • Very small quantity of milk required. • Low power consumption. • No use of hazardous chemicals. • One year warranty. • Measuring accuracy adjustment can be done
by the user RS 232 Interface.• ESC POS Printer Support. • Two samples self-calibration.
M-MIA-CC
M-MIA-A
Top Related