7/28/2019 MIL-G-48737 Grenade, Hand, Offensive, Mk3A2
1/19
NIL-G-48737 (PA)1 October 1975
MILITARY SPECIFICATIONGRENADE, HAND, OFFENSIVE; MK3A2 w/FUZE M206A2 WITH SAFETY CLIPLOADING, ASSEMBLING AND PACKING
This specificationis approved for use by all Departmentsand Agencies of the Department ofDefense.1 SCOPEZ.1 This specification covers the loading, assemblingand packing for one type of grenade, designated as Grenade$Hand, Offensive; MK3A2, with Fuze F1206A2with Safety clip,usfngthe Charge Demolition: Block (TNT) 1/2 Pound Assembly.2. APPLICABLE DOCUMENTS2.1 The followlng documents of the Issue in effect ondate of invttatfon for bids or request for pro~osal. form apart of this specificationSPECIFICATIONS
MILITARYMIL-A-48078 -
STANDARDSMILITARY
MIL-sTD-lo5 -
P?IL-STD-1169 -
to the-extent sp~cified herein.
Ammunition, Standard Quality Assur-ance Provisions, General Specl.fica-tlon For
Sampling Procedures and TablesFor Inspection by Attributes (ABC-STD-105)Packaging, Packing and MarkingFor Shipment of Inert AmmunitionComponents
Source: http://www.assistdocs.com -- Downloaded: 2013-06-11T07:57ZCheck the source to verify that this is the current version before use.
7/28/2019 MIL-G-48737 Grenade, Hand, Offensive, Mk3A2
2/19
MIL-G-4873T (PA)DRAWINGS
U.S. ARMY PICATINNY ARSENAL9215458 -g274414, -
g274416 -
Grenade, Hand, Offensive; MK3A2 w\FuzeM206A2 with Safety ClipPacking and Marking for Container,Ammunition, Fiber PA76 for Grenade, Hand,Offensive; MK3A2 w/Fuze M206A2 withSafety ClipPacking and Marking for Box, Ammunition forGrenade, Hand, Offensive;m3A2 w/Fuze M206A2with Safety Clip in Fiber Container PA76.
CCopies of specifications,standards, and drawings requiredby suppliers in connectionwith specific procurement functionsshouldby the be obtained from the procuring activity or as directedContracting Officer).
3* REQUIREMENTS3. 1 Material. - Materials shall be in accordance withapplicable drawings and specifications.3.2 Grenade. - The grenade shall comply with all require-ments specified on Drawing (dwg.) 9215458 and with all require-ments specified in applicable specifications.3.3 Functioning. - The grenade shall detonate in not lessthan three (3) seconds nor more than 10 seconds, withoutevidence of large fragments of unburned explosive.3.4 Release resistance. - The safety clip shall not be
disengaged from its assembled position over the lever by aload of twenty-five (.25)ounces, minimum (min.) when tested(see 6.4).
3.5 X-ray examination of Fuze Grenade M206A2 prior toloadingin theGrenade:~~~e,eA2. - ~~ch fuze shallbeX-rayedand its radiograph shall .beexamined before loadingof the fuze into the grenade for the following defects:delay column missing; short delay column; Variation in columndensity; voids at bottom of delay column; anvil punch penetra-
$
2
Source: http://www.assistdocs.com -- Downloaded: 2013-06-11T07:57ZCheck the source to verify that this is the current version before use.
7/28/2019 MIL-G-48737 Grenade, Hand, Offensive, Mk3A2
3/19
MIL-c&48737 (PA)tion at bottom of deI.aycolumn; porosity in the fuze body;broken styphnate and azide In detonator cup; foreign matterin delay column. This examination shall be conducted asspecified.
3. 6 Workmansh2~. - All,parts and assemblies shall be fab-ricated and loaded in a thorough workmanlike manner, and allmanufacturing, processing, and assembly operations shall becorrectlyperformed. They shall be clean and free of burrs,sharp edges, unblended radii, surface defects, chips$ dirt,grease and oil (except where specifically required), corrosionproducts and other foreign matter. The cleaning method usedshall not be in~uri.ous to any part or assembly nor shall theybe contaminated by the cleaning agent. Exterior surface coat-ings shall be continuous except for a few light scratches notexposing base material. All required markings shall be neatand sharply defined. Required packing shall be dry.
3.7 IHrst article inspection,.- This specification containstechnical provisions for first article inspection. Requirementsfor the submission of first article samples by the,contractorshall be as specified In the-contract.4. QUALITY ASSURANCE PROV1S1ONS4.1 Responsibilityfor inspection and standard qualityassurance provislonso - Unless otherwfse s ecffied herein or%n he contract, Ehe provisions of MTL-A-4 078 shall applyand are hereby made a part of this detail specification.4.2 Classificationof inspections. - The following types
of hSpeCtbn shall be conducted on hls item.First article inspection:: Quality conformanceinspection4.3 First article inspection4.3.1 Submission. - The contractor shall submit a firstarticle sample (see b.lb) as designated by the ContractingOfficer. The first article sample shall consist of twenty (20)complete sets of parts and sub-assemblies (i.e.$twenty (20)each of every component and sub-assembly). The first articlesample shall be evaluated in accordance with the provisions of
4.3.2 and 4.3.3.3
Source: http://www.assistdocs.com -- Downloaded: 2013-06-11T07:57ZCheck the source to verify that this is the current version before use.
7/28/2019 MIL-G-48737 Grenade, Hand, Offensive, Mk3A2
4/19
MIL-G-48737 (PA)4.3.2 Inspections to be performed. - See MIL.A-48078 andparas 4.4.2.1 thru 4.4.2.5, testing per para. 4.4.3, and Table Ispecified herein.4.3.3 Rejection. - (See MIL-A-48078)
4
Source: http://www.assistdocs.com -- Downloaded: 2013-06-11T07:57ZCheck the source to verify that this is the current version before use.
7/28/2019 MIL-G-48737 Grenade, Hand, Offensive, Mk3A2
5/19
0 u
eTABLE1
-FZRSTARTICLEINP.ECTZON
CAFCOOD
T
#t+
HIL-G-L8737(PA)
RW~GN
G
H
O
M
w
l
9
I
w
S
C
S
?EHG
AM
NA
C
NO
A
EMO
T
S
RR
P
UT
tz
P
/N
OM
P
.
p
,
In
Ps
Emno
fodes
20
3.2
4423thru.4$2.5
F
G
E
d
2
3
4
T R
r
2
1
X
e
2
:
4
Amy
Emno
fodes
20
3.2
h.b.2.3
Tests
Functioning
20
3*3
4.5.1
N
>
S&O
F
,.,
,,,,
.
.
.
Source: http://www.assistdocs.com -- Downloaded: 2013-06-11T07:57ZCheck the source to verify that this is the current version before use.
7/28/2019 MIL-G-48737 Grenade, Hand, Offensive, Mk3A2
6/19
MIL-G-48737 (PA)4.4 Quality conformance inspection4.4.1 Inspectionlot formation.- Inspectionlots shallcomply with the lot formationprovisionsof MIL-A-48078.In addition,inspectionlots of grenadesshall contain:
a. Parts of one lot interfix number from-one manu-facturer.b. Fuzes from not more than one serial lot of onelot interfix number from one manufacturer.c. Charges from one supplier containingnot morethan two lots of TNT from one manufacturer.
4.4.2.Examination.- (See MIL-A-48078). Unless otherwisespecifiedin the classificationof defects and test tables,samplingplans for major and minor defects shall be in accord-ance with MIL-STD-105,InspectionLevel II. Equipment nece-ssary for the performanceof the inspectionslisted shall bein accordancewith 4.4.4
Source: http://www.assistdocs.com -- Downloaded: 2013-06-11T07:57ZCheck the source to verify that this is the current version before use.
7/28/2019 MIL-G-48737 Grenade, Hand, Offensive, Mk3A2
7/19
*
1
i?2!v$5
;Mla
o0aG-4o
fSource: http://www.assistdocs.com -- Downloaded: 2013-06-11T07:57ZCheck the source to verify that this is the current version before use.
7/28/2019 MIL-G-48737 Grenade, Hand, Offensive, Mk3A2
8/19
0
CAFCOOD
T
MILGb
(PA
P
TT
DWNN
4422
C
A
t
S
1
9
A
F
O
N
HG
AM
N
C
NO
A
ENOOT
S
RRM
P
R
UT
IO%
P
/N
OM
C
N
d
M
B 1
F
f
w
o4%32
Vsu
Min201.
E
p
w
1+%3.6
Visual
N e
-.
--
.
Source: http://www.assistdocs.com -- Downloaded: 2013-06-11T07:57ZCheck the source to verify that this is the current version before use.
7/28/2019 MIL-G-48737 Grenade, Hand, Offensive, Mk3A2
9/19
0
CAFCOOD
&T
MLq4
(P
{
P~
DWNN
.4,2.3
r3renade,and,Assembly
SM
1O2
9215458
NHG
A3A
NO
A
C
ENO0T
S
RRM
P
,
UT
Ko%
P
M
/N
OM
:c
,
1
SafetyPnpo
ca
oinCeC~Y
formed
1%
32
V
2
P
ringassemblymissing
1%
32
Vsu
3
Safetyclipmissingorincorrectly
assembled
100%
3.2
Visual
4
Eitherorbothleverhingeearsmissing
1
32
Vsu
5
Bothleverhingeearsnotbentawayfrom
the
bodypastthevert~calcenterline
ofthebodyhingebosses
1%
3.2
Yisual/FigurelB
6
Endsofbothleverhingeearsnotbent
upwards
100$
32
V
1
?
A
1
E
l
h
e
n
b
a
f
t
b
p
t
v
c
lnofthebodyhingebosses
04%32
Visual/FigurelB
102
Endofeitherleverhingeearnotbent
upwards
0.40%
3.2
Visual/Figure1A
flajor
131
Fuzeofincorrectdesignat.lon
04
32
Visual
132
Washerm$ssing
:.C$
;.;
Visual
1
Fuzenotfullyseated
.
.
Visual
HoTs&
\
-----
Source: http://www.assistdocs.com -- Downloaded: 2013-06-11T07:57ZCheck the source to verify that this is the current version before use.
7/28/2019 MIL-G-48737 Grenade, Hand, Offensive, Mk3A2
10/19
CAFCO
T
MLG4
(P)
P
TT
DWNN
4423
Grenade,Hand,Assembly
9215458
cent
S
2O2
N
HG
AM
NO
A
C
ENOOT
S
O
RRM
P
R
UT
1%
P
/N
O
M
Minor
201
Overallheight
0.65%
3.2
Gage
202
Markingincorrect,incompleteorillegiblt
0.65%
3.2
Visual
203
Evidenceofpoorworkmanship
1.00%
3.6
Visual
Ya,lor
,,,
Test
ReleaseResistance
,,,
500
(a)
3=4
4.5.2
.(G)Note
Acceptwith5orlessdefects
Rejectwith6ormoredefects
(
N .
-m.
--
,
.
,
.
*
Source: http://www.assistdocs.com -- Downloaded: 2013-06-11T07:57ZCheck the source to verify that this is the current version before use.
7/28/2019 MIL-G-48737 Grenade, Hand, Offensive, Mk3A2
11/19
*
q
CAFCOOD
T
MIL-G-h8737(PA)..
DWNN
&2&Seed
FbCaw
SW
927,4414
HEXYil~li~ll
AM
NA
MO
A
C
W
SHOO1
S
i?KEEP
UT
&%
P
/N
OAM
(kG
N
dn
M
B131.&mtainerutorpuncturedhroughlllayers
Ok
Visual
1
T
i
b
w
04%xVaw
1
M
elo
dsoe
opue
;40
3.2
Visual
134
G
q
3
M
~2
C
0
3
M
2
T
tm
0
3
V
2
H
n
inmeeoiebe
065%
visual
204.Evidencefpoororkmanship
1.OZ
:::
visual
N
--
-
--
VAFOMX
F
7
Source: http://www.assistdocs.com -- Downloaded: 2013-06-11T07:57ZCheck the source to verify that this is the current version before use.
7/28/2019 MIL-G-48737 Grenade, Hand, Offensive, Mk3A2
12/19
CAFCOOD
T
MIL-G-48737(PA)
P
TT
DWNN
4425W
P
~
~1
9274416
N
HG
AM
N
NO
A
C
ENOOT
S
O
RRM
P
R
UT
1%
P
/N
OM
C
N
d
M
B 1
S
w
m
l
04%32V
1
H
ol
(
a
oh%
V
133.
B
d
oLO%:
V
F
201
S
w
i
0
3.2
V
202
M
i
i
O%
V
2
E
p
w
10%;
V
N .
-
-
--.
S
Q
#
F
Source: http://www.assistdocs.com -- Downloaded: 2013-06-11T07:57ZCheck the source to verify that this is the current version before use.
7/28/2019 MIL-G-48737 Grenade, Hand, Offensive, Mk3A2
13/19
MIL-G-48737 (PA)SAFE2Y LEVER SAFETY LEVER
L~G .;r~ ... : ! CT%
REJECT(Tips Not Turned VP)
h FUZE \.BODYY
/TIP
I
/
REJECT ?(Tips Not Past ~
\
Center $Ane of Lug)B
/,
L .ACCEPTABLE(TipsPast CenterLine and TurnedUP) .
\,
\,
1-,
k UZEODY
/ $,I_/FIGURE 1
b~iIMAGINARY&OF LUG,~Dad/ , ----1 FUZEi j 1 SAFETY\~ \,(
LEVER
I13Source: http://www.assistdocs.com -- Downloaded: 2013-06-11T07:57Z
Check the source to verify that this is the current version before use.
7/28/2019 MIL-G-48737 Grenade, Hand, Offensive, Mk3A2
14/19
MIL-G-48737 (PA)4.4.3 Testing4. 4. 3. 1 Functi.onin&. - The grenadeobserved for any evidence of failure torequirements as classified in Table II.
TABLE IIDefects
Functioning time less than min.or greater than max. (See 3.3)Failure to function (see 3.3)Evidence of large fra ments of7nburned explosive see 3.3)
4.4.3.1.1 Beginning with the first
assemblies shall becomply with the
ClassificationCriticalMajor A
Major Alot produced and con-
tinuing until three (3) consecutive lots have com lied with7he applicable requirements specified, eighty (8o grenadesassemblies shall be selected for test. The lot shall berejected if during the test a critical defect occurs or ifthree (3) or more assemblies exhibit any of the major defectslisted in.Table II.
4. 4. 3. 1. 2 After three (3) consecutive lots have compliedwith the acceptance criteria of 4.4.3.1.1, thirty (30) grenadeassemblies shall be selected for test. The lot shall beaccepted on zero failures and,shall be rejected if a criticaldefect occurs, or if two (2) or more grenades exhibit any ofthe defects listed in Table 11. The lot shall undergo aretest of thirty (30) samples if one major defect (see TableII) occurs in the initial sample group. Upon retesting thelot shall be rejected if a critical defect occurs or if twoor more assemblies exhibit any of the major defects listedin Table II.
4.4.3.2 X-ray examination of fuze assembly prior to loadinginto the grenade~handMK3A2(see305). Each fuze prior to
14
.Source: http://www.assistdocs.com -- Downloaded: 2013-06-11T07:57ZCheck the source to verify that this is the current version before use.
7/28/2019 MIL-G-48737 Grenade, Hand, Offensive, Mk3A2
15/19
ML-G-48737 (I ?~)loading Into the NX3A2 grenade shall be subject to the exsmina-tlom for compliance with the requirements as specified in Table111.
TABLE IIIDefects
M$ssing delay columnShort delay columnVariation in column density* Voids at bottom of delay columnAnvil punch penetration at bottom1 of delay columnPorosity in fuzebodyBroken styphnate and azi.deindetonator cupForeign matter in delay column
ClassificationCriticalcriticalMajor AMajor AMajor AFlayerAMajor AMajor A
If any fuze shows evidence of any of the defects listed in TableIII, it shall be classified defective and removed from the lot.(see 6.6). The method of fuze examination shall be as specifiedin 4.5.3. Definitions of defective fuzes are defined in 6.5.4.4.4 Inspection equipment. - lhenspection equipment re-quired to perform the inspectlons and tests prescribed in thisspecificationis identified in the Paragraph Reference/Inspec-tion lWethodlcolumn in the tables starting with paragraph 4.4.2.1,and the test method paragraphs (see 4.5). The contractor shallsubmit for approval, inspection equipment designs in accordance.with the terms of the contract. (See Section 6 of MIL-A-48078,and 6.2 herein.)4.5 Test methods and procedures4.5.1 Functioning. - The grenade assembly shall be Immersedin water maintained at seventy (70) plus or minus five (5) de rees?)ahrenheit (F.) for one hour at a depth of not less than two 2Inches. The assembly shall be removed from the water and withinone hour shall be mounted In the functioning test flxtune specifiedin 4.4.4 and detonated by remotely removing the safety pin. Thefixture and grenade.shall be centered in a barricaded arena capableof withstanding the effects of detonation. The grenade assemblyskkallbe observed for compliancewith the requirements.
15
Source: http://www.assistdocs.com -- Downloaded: 2013-06-11T07:57ZCheck the source to verify that this is the current version before use.
7/28/2019 MIL-G-48737 Grenade, Hand, Offensive, Mk3A2
16/19
MIL-G-48737 (pA). . 4.5.2 Release resistance. - The load shall be applied slowlyand steadily, parallel with he safety pin in the clip releasingdirection, until the total load is supported by the clip. Theclip shall be observed for compliance with the requirements.
4.5.3 X-ray examination of fuze assembly. - Inspection equip-ment and the image quality of the radiographs for this examinationshall be satisfactoryto the Procurement Contracting Officer.The direction of the x-ray beam employed in this inspection shallbe perpendicular to the axis of the delay tube.
5* ,,PREPARATIONOR DELIVERY5.1 Preservation and Packaging5.1.1 Level A. - The grenade or grenades, shall be packagedin accordan- dwg. 9274414.5. 2 Packinq.5. 2. 1 Level A. - The unit orbe packed i-dance with dwg.5.3 Marking. - Marking shall9274414 and 9274416.
carton packaged grenades shall9274416.be in accordance with dwgs.
6. NOTES6. 1 Ordering.Data. - Procurement documents shall specifythe following:
and date of this specification,. Title, numberb. Provisions for submission of first article samples.c. provisions of MIL-A-48078.6.2 Submission of inspection equipment designs for approval. -(See MIL-A-48078). Submit equipment designs as required, toCommander: Picatinny Arsenal, ATTN: SARPA-QA-T Dover, NewJersey 07801.6.3 Distributionof ammunition data cards. - Distributionof data c~ owing: ommander, PicatinnyArsenal, ATTN: SARPA-QA-A-M and SARPA-AD-E-C2 Dover, New Jersey07801. Data cards for all lots of grenades and fuzes submitted
to 100% x-ray screening should be annotated to reflect performanceof this inspection.
16
Source: http://www.assistdocs.com -- Downloaded: 2013-06-11T07:57ZCheck the source to verify that this is the current version before use.
7/28/2019 MIL-G-48737 Grenade, Hand, Offensive, Mk3A2
17/19
NIL-G-48737 (PA)6.4 Release Resistance. - The safety clip shall be considereddisengaged from its assembled position over the lever when the squareend of the safety clip moves upon the flat surface of the leverto the extent that the clip does not return to +ts originalassembled position when the load Is removed.6.5 Definitions of critical and major .defectsfor use inx-r.6.5.1 rY~iSSinEr short delay column - (Critical Defect). -TMs defect 3.sdefined, as crittcal when there is no coIumn or*. when,the delay column does not reach the base oilthe threadedportion of the fuze body.6.5.2 Variation in column density (Major A Defect). - Thisdefect is defined as a major defect when there is significantvariation within a given delay column , of the apparent columndensity as viewed on the radiograph.6.5.3 Voids at the bottom of delay column (Major A Defect). -This defect is defined as a major defect when the void at thebottom of the delay column (detonatorend) extends across theentire diameter of the fuze body delay cavity.6.5.4 Anvil punch penetration at bottom of the delay column(Major A defect). - This defect is defined as a major defect whenthe anvil punch penetration at the bottom of the delay column,including any breakout, extends more than 0.100 inch up into thecolumn. (NOTE: Fuzes without any other defects which have anvilpunch penetration, including breakout which does not extend morethan 0.100 inch up into the column are acceptable providing theheight of the delay column is at least 0.700 inch when measured
from the top of the anvil punch mark or breakout. Measurement isnot made from the base of the delay column).6.5.5 Porosity in the fuze body (Major A defect). - This defectIs defined as a major defect when the fuzebody at the intersectionof the threaded portion and the delay Column$ is round to be pOI+OUS.6.5.6 Broken styphnate and azfd.ein detonator cup (Major Adefect). - ~his defect f.Sdefined as a major defect when my broken0 crumbled, or loose styphnate and azide is detected In the detonatortube.
!.
17
Source: http://www.assistdocs.com -- Downloaded: 2013-06-11T07:57ZCheck the source to verify that this is the current version before use.
7/28/2019 MIL-G-48737 Grenade, Hand, Offensive, Mk3A2
18/19
MIL-G-48737 (PA)6.5.7 Foreign matter in delay column (Major A defect). - Thisdefect is defined as a major defect when any foreign matter isdetected in the delay column which could preclude the proper ini-tiation and propagation of the delay element,6. 6 Disposition of defective fuze assemblies6. 6. 1 Critically defective fuze assemblies. - When a criticallydefective fuze is found, this Arsenal (SARPA-QA-A-M) shall benotified immediately and the fuze held pending disposition and inno instance will the fuze be destroyed without permission of theProcurement Contracting Officer.6.6.2 X-ray examination of defective fuze assemblies. - Alldefective fuzes shall be re-x-rayed to confirm their identity,and the effectiveness of the screening process, in additions thisArsenal (SARPA-QA-A-M) will be notified on a continuing basis ofthe quantities and specific types of defects found per lot, sothat remedial action may be taken at the fuze contractors plant.
Custodian: Preparing Activity:Army-PA Army-PAProject Number: 1330-A-072
Source: http://www.assistdocs.com -- Downloaded: 2013-06-11T07:57ZCheck the source to verify that this is the current version before use.
7/28/2019 MIL-G-48737 Grenade, Hand, Offensive, Mk3A2
19/19
STAF4DARDI ZATI O14DOCUMENT l MPR0VEME14T PROPOSAL I OMB I%frptOVdNo. 22-R2SSINSTRUCTIONS:hep~rposefthisformh tosolicit beneficialomments whichill help achieve procure-mertt of suitable products at reasonable cost andmin~m~mel~y,rwiltotherwiseenhance use of the documentDoD contractors, government rictivit,ieci, or manufocturceo/ vendors who are prosgmcti ve suppliers of the productme ~mv~tedo submit comments to tfre government. Fold on lines on reverseside,stapleincomer, and send topreparing activity. Comments submitted on this form do not constitute or imply authorization to waive wry .portion of the referenced document(s) or to smend contrnctunl requirements. Attach any pertinent data whichmay be of use in improving this document. Ifthereareadditional papers,atlsch to form and plsce both in anenve!ope addressed to preparing sctivlty.IOCUMENT iDENTIFIER ANO TITLE
IAME OF ORGANl ZAT@Ot4 ANO AOORESS CONTRACT NUMBER
MATERIAL PROCUREO uNDER AO DIRECT GOVERNMENT CONTRACT ~SUS3COMTRAC
HAS ANY PART OF TuE UOCtIMENT CREATED PROBLEMS OR REQuIRED #NTERPRIETATfl ON IN PROCUREMENTuse?A. GIVE P& RAGRAp H NUMOER AND WOROING.
. .
0. RECOMMENDATIONS FOR CORRECTING TuE 0K3F~Cl EINCl ES
COMMENTS ON ANY 00 CUMENT REQuIREMENT CONSIDERED TOO RIGIO
IS THE DOCUMENT REST5?ICTIVE?~ YE, ~J MO (~f Yeo, h what woy?)
REMARKS
UBMITTE D BY (prirrtodrtypedrrnmen d m k t ro oo - o pt h no ll TELEPHONE NO.
DATE
DUY721426 F?tiPLa,Ccg EO?T$O?4F t JAN eil WHICHMA~ ea ~9aD
Top Related