Index
Part numbers listed are for internal purpose and are subjected to change.
Stock Items
ComponentSelection Chart
Fuselink selectionType II co-ordination - Fuse back-upType II co-ordination - Fuseless system
Controlgear
Auxiliary ContactorsPower ContactorsThermal Overload RelayElectronic TimersMPCBCLDOL Starter
Fusegear
LV HBC Fuselinks for Industrial ApplicationsHBC Fuselinks for protection ofSemiconductor DevicesHigh Voltage HBC FuselinksMoulded Fuse Holders and Fuse BasesFuse Distribution Boards
Switchgear
Wall mounting type CombinationFuse Switch UnitsWall mounting type Switch Fuse Units/ Fuse Switch UnitsSwitch Disconnector Fuse Units in open execution& in SS EnclosuresFuse Switch Disconnector UnitsOn Load Changeover Switches
Circuit Breakers Moulded Case Circuit BreakersAir Circuit Breakers
ResidentialProducts
Miniature Circuit Breakers, MCB Distribution BoardsResidual Current Circuit BreakersTime Switches
BuswaysBusway SystemsAccessories for Busways
LV Capacitors MPP, APP & Mixed Dielectric
A2-4
B5-13
C14-20
D21-25
E26-42
F43-46
G47-48
H49-50
A2
Typ
e R
efe
ren
ce &
Ra
tin
g
Cu
rre
nt
Ra
tin
g(A
MP
S)
Typ
e
“VS
”Ty
pe
“T
S”
Typ
e
“T”
Do not use the Fuselinks having higher Current Rating than the rating of the equipment
Fuselink Selection Chart
CMM
WITH
BS
FUSES
SP
WITH
DIN
FUSES
SP
WITH
BS
FUSES
SP CLIPON FUSES
CHD
CH
WM
LP
DIN
SAFECLIP
NS/SM
Ind
ep
en
de
nt
Mo
un
ted
Sw
itch
es
Fuse
Fit
tin
gs
Pa
ne
l Cu
bic
le M
ou
nte
d S
wit
che
s
Fuselink Selection Chart
2A
-20
A2
A-2
0A
25
A-3
2A
2A
-63
A2
A-3
2A
36
A-6
3A
6A
-32
A3
6A
-63
A8
0A
-12
5A
12
5A
-20
0A
80
A-1
00
A1
25
A-2
50
A2
50
A-3
15
A3
55
A-4
00
A4
00
A-6
30
A6
30
A-8
00
A8
0A
-10
0A
80
A-1
25
A1
25
A-1
60
A1
25
A-2
00
A1
25
A-2
50
A2
50
A-3
15
A4
50
A-5
00
A3
55
A-4
00
A3
55
A-4
00
A4
50
A-5
00
A5
60
A-8
00
A5
60
A-8
00
A6
A-6
3A
6A
-16
0A
36
A-2
00
A3
6A
-25
0A
25
0A
-31
5A
25
0A
-40
0A
31
5A
-63
0A
VS
A
VS
BV
SF
VS
FV
SK
VS
KV
ST
TSD
STS
DS
TSFP
TSF
TSF
TSK
TST
TSM
TSM
STS
TSTS
LSTS
L
TSA
TSS
TSD
TSD
C
SS
NS
NS
ES
EIT
EIT
TIA
TIS
TCP
TFP
TC TF TKF
TM TTM TLM
NSHSM32SM63
SM125SC20SC32SC63
ISG160ISG250ISG400ISG630
LP32LP63
WM20WM32WM63CH63
CH100CH200CH315
CHD400CHD500CHD630CHD800
SP32SP63SP32SP63
SP100SP03
SP160SP04SP05SP06SP07
SP630SP800SP63D
SP100DSP03D
SP160DSP04DSP05DSP06DSP07D
SP630DSP800DCMM125CMM200CMM250CMM315CMM400CMM630CMM800
6A
-10
0A
VS
B
VS
B6
A-1
25
A
Low Voltage Components - Buy Log Effective from 29.12.2008
A3
Component Selection Chart
MOTOR SWITCH FUSE HBC FUSE CONTACTOR O/L RELAY
KW HPFLCAmps
Type
MOTOR
RatingAmps
Type RatingAmps
Type RatingAmps
Type RatingAmps
MOTOR SWITCH FUSE HBC FUSE CONTACTOR (Star) O/L RELAY
KW HPLineAmps
Type
MOTOR
RatingAmps
RatingAmps
Type RatingAmps
PhaseAmps
RatingAmps
Type Type RatingAmps
Type
Motor Feeders 415V - DOL Starting - Type 2 coordination as per IS 13947
0.37 0.5 1.1 SP32 32 EIT4 4 CL00 9 RT0G 1.0-1.5
0.55 0.75 1.5 SP32 32 EIT4 4 CL00 9 RT0G 1.0-1.5
0.75 1 2 SP32 32 EIT4 4 CL00 9 RT0J 1.5-2.2
1.1 1.5 2.5 SP32 32 EIT6 6 CL00 9 RT1J 1.8-2.7
1.5 2 3.4 SP32 32 EIT10 10 CL00 9 RT0K 3.2-4.8
2.2 3 4.5 SP32 32 EIT10 10 CL00 9 RT0L 4.7-7
3 4 6.2 SP32 32 EIT16 16 CL00 9 RT0M 6.7-10
3.7 5 7.3 SP32 32 EIT16 16 CL00 9 RT0M 6.7-10
5.5 7.5 11 SP32 32 EIT20 20 CL01 12 RT0P 10-15
7.5 10 14 SP32 32 EIT32 32 CL02 18 RT0P 10-15
9.3 12.5 19 SP63 63 EIT32 32 CL25 52 RT0U 19-28
11 15 21 SP63 63 EIT50 50 CL25 25 RT0U 19-28
15 20 28 SP63 63 EIT63 63 CL04 32 RT1V 25-32
18.5 25 35 SP100 100 TSD80 80 CL45 40 RT1W 30-40
22 30 40 SP100 100 TSD80 80 CL45 40 RT2E 30-43
30 40 55 SP03 125 TSDS100 100 CL07 65 RT2H 54-65
37 50 66 SP03 125 TSDS100 100 CL07 65 RT2J 64-82
45 60 80 SP160 160 TSFP160 160 CL08 80 RT2J 64-82
50 66 88 SP160 160 TSFP160 160 CL09 95 RT2L 78-97
55 75 100 SP05 250 TSF200 200 CL10 105 RT2M 90-110
75 100 135 SP05 250 TSF250 250 CL13 140 RT3E* 110-140
90 125 165 SP05 250 TSF250 250 CK08 185 RT3F* 140-190
110 150 200 SP06 315 TSK315 315 CK85 205 RT4P* 175-280
132 180 230 SP07 400 TSMS400 400 CK09 250 RT4LP* 175-280
160 215 285 SP07 400 TSMS400 400 CK95 309 RT4LR* 200-310
200 270 350 CMM 400 TSMS400 400 CK10 420 RT5LD* 315-500
250 335 437 CMM 630 TST500 500 CK11 550 RT5LD* 315-500
315 430 530 CMM 630 TST560 560 CK11 550 RT5LE* 430-700
355 480 600 CMM 630 TST630 630 CK12 700 RT5LE* 430-700
450 600 750 CMM 800 TST800 800 CK13 825 RT6LA* 500-850
CONTACTOR (Delta)
Motor Feeders 415V - Star Delta Starting - Type 2 coordination as per IS 13947
2.2 3 4.8 2.8 SP32 32 EIT6 6 CL00 9 CL00 9 RT0H 2.2-3.3
3.7 5 7.8 4.5 SP32 32 EIT10 10 CL00 9 CL00 9 RT0K 3.2-4.8
5.5 7.5 11 6.5 SP32 32 EIT16 16 CL00 9 CL00 9 RT0L 4.7-7
7.5 10 14 8.1 SP32 32 EIT20 20 CL00 9 CL01 12 RT0M 6.7-10
9.3 12.5 18 10.4 SP32 32 EIT25 25 CL00 9 CL01 12 RT0P 10-15
11 15 21 12.1 SP32 32 EIT25 25 CL01 12 CL02 18 RT0P 10-15
15 20 28 16.1 SP32 32 EIT32 32 CL02 18 CL25 25 RT0S 14-20
18.5 25 35 20.2 SP63 63 EIT50 50 CL02 18 CL25 25 RT1T 17.5-22
22 30 40 23 SP63 63 EIT50 50 CL25 25 CL03 25 RT1U 21-26
30 40 53 30.6 SP63 63 EIT63 63 CL04 25 CL45 40 RT1W 30-40
37 50 66 37.5 SP100 100 TSD80 80 CL04 32 CL06 50 RT1W 30-40
45 60 78 45 SP03 125 TSDS100 100 CL04 32 CL06 50 RT2G 42-55
55 75 100 58 SP03 125 TSDS100 100 CL45 40 CL07 65 RT2H 54-65
75 100 135 78 SP160 160 TSFP160 160 CL06 50 CL08 80 RT2J 64-82
90 125 165 95 SP160 160 TSFP160 160 CL08 80 CL10 105 RT2M 90-110
110 150 200 115 SP05 250 TSF250 200 CL08 80 CL13 130 RT3D 90-120
132 180 240 139 SP05 250 TSF250 250 CL09 95 CK75C 150 RT3E* 110-140
160 215 271 156 SP06 315 TSK315 315 CL13 140 CK08C 185 RT3F* 140-190
200 270 340 196 SP07 400 TSMS355 355 CK75C 150 CK85B 205 RT4LP* 175-280
250 335 398 243 CMM 630 TSMS400 400 CK08C 185 CK95B 309 RT4LP* 175-280
315 430 530 328 CMM 630 TSL560 560 CK85B 205 CK10C 420 RT5LC* 250-400
355 480 600 360 CMM 630 TSL630 630 CK85B 205 CK10C 420 RT5LC* 250-400
400 536 673 404 CMM 800 TSL750 750 CK10C 420 CK10C 420 RT5LD* 315-500
450 600 756 438 CMM 800 TST800 800 CK10C 420 CK11C 550 RT5LE* 430-700
Above overload relay ratings recommendation is for load with normal starting time. For long starting time please contact our nearest sales office*
Low Voltage Components - Buy Log Effective from 29.12.2008
0.55/0.75 1.5 GPS1BSAF 1.6 CL00 9
0.75/1 1.9 GPS1BSAG 2.0 CL00 9
1.1/1.5 2.5 GPS1BSAH 4.0 CL00 9
1.5/2 3.4 GPS1BSAH 4.0 CL25 25
2.2/3 4.8 GPS1BSAJ 6.3 CL25 25
3.7/5 7.7 GPS1BSAK 10 CL25 25
5.5/7.5 11.6 GPS1BSAL 13 CL25 25
7.5/10 14.4 GPS1BHAM 16 CL25 25
11/15 21.1 GPS1BHAP 25 CL25 25
15/20 28 GPS2BHAM 32 CL04 32
18.5/25 35 GPS2BHAS 40 CL45 4022/30 41 GPS2BHAT 50 CL06 50
30/40 55 GPS2BHAU 63 CL07 65
37/50 60 GPS3BHAV 100 CL10 105
45/60 83 GPS3BHAV 100 CL10 105
55/75 99 GPS3BHAW 200 CK75C 150
75/100 136 GPS3BHAW 200 CK75C 150
90/125 162 GPS3BHAW 200 CK08C 185
110/150 200 GPS3BHAX 400 CK09B 250
132/180 231 GPS3BHAX 400 CK10C 420
150/203 263 GPS3BHAX 400 CK10C 420
160/215 281 GPS3BHAX 400 CK10C 420
185/250 324 GPS3BHAX 400 CK10C 420
200/270 354 GPS3BHAX 400 CK10C 420
LineCurrent@415V
Surion MPCB Contactor
RatingType Type(A)
Type 2 Coordination - DOL 415V (50 kA)
MotorRatingKW/HP (A)
(A)
A4
Type 2 Coordination - Star Delta 415V (50 kA)
Note:
The MCPB will trip only on Short-circuits and on overloads it gives a trip signal to the contactor through a NC control froman inbuilt relay.The MCPB also gives the trip signal through NC control from the inbuilt relay to the contactor for protection against single phasing and phase reversal.
Component Selection Chart
LineCurrent@415V
Contactor
RatingType Type(A)
MotorRatingKW/HP (A)
(A)2.2/3 4.8 2.8 GPS1BSAJ 6.3 CL25 25
3.7/5 7.7 4.5 GPS1BSAK 10 CL25 25
5/5/7.5 11.6 6.7 GPS1BSAL 13 CL25 257.5/10 14.4 8.4 GPS1BHAM 16 CL25 25
11/15 21.1 12.2 GPS1BHAP 25 CL25 25
15/20 28 16.2 GPS2BHAR 32 CL04 32
18.5/25 35 20.3 GPS2BHAS 40 CL04 32
22/30 41 23.8 GPS2BHAT 50 CL06 50
30/40 55 31.9 GPS2BHAU 63 CL06 50
37/50 69 40 GPS3BHAV 100 CL08 80
45/60 83 48.1 GPS3BHAW 200 CL09 95
55/75 99 57.4 GPS3BHAW 200 CL10 105
75/100 136 78.9 GPS3BHAW 200 CK75C 150
90/125 162 94 GPS3BHAX 400 CK08C 185
110/150 200 116 GPS3BHAX 400 CK09B 250
150/203 263 152.5 GPS3BHAX 400 CK95B 309
160/215 281 163 GPS3BHAX 400 CK95B 309
185/250 324 187.9 GPS3BHAX 400 CK10C 420
(A)
PhaseCurrent@415V
Surion MPCB
Low Voltage Components - Buy Log Effective from 29.12.2008
• Series RL and its accessories
• Series (M) Mini and its accessories
Power Contactors
• Series CL 3P, AC
• Series CK 3P, AC
• Series CL 3P, DC
• Series CK 3P, DC
• Series CL 4P, AC
• Series CK 4P, AC
• Series CSC capacitor switching
Accessories for Contactors
• Spares for contactors
Thermal Overload Relay
• Series RT and its accessories
Motor Protection Circuit Breaker
• Surion and its accessories
CL DOL Starter without enclosure
• Up to 10 hp 3 phase.
Auxiliary Contactors
B5
Controlgear
Low Voltage Components - Buy Log Effective from 29.12.2008
B6
Auxiliary Contactors
Series RL- AC1 rating: 20 A AC - Control
Controlgear
Contacts Code
Arrangement Reference
Buy Log/
Unit
4NO 690
3NO+1NC 690
2NO+2NC 690
4NC 690
RL4RA040T
RL4RA031T
RL4RA022T
RL4RA004T
DC - Control
Contacts Code
Arrangement Reference
4NO t 1020
3NO+1NC t 1020
2NO+2NC t 1020
4NC t 1020
RL4RD040T
RL4R 031TD
RL4R 022TD
RL4R 004TD
Series M (Mini) - AC1 rating: 16A AC - Control
Contacts Code
Arrangement Reference
4NO t 650
3NO+1NC t 650
2NO+2NC t 650
1NO+3NC t 650
4NC t 650
MCRA040AT
MCRA031AT
MCRA022AT
MCRA013AT
MCRA004NT
DC Control
Contacts CodeArrangement Reference
4NO t 860
3NO+1NC t 860
2NO+2NC t 860
MCRC040AT
MCR 031ATC
MCR 022ATC
Coil Voltage Codes - AC/DC
t D G J N W
AC/50Hz 24 48 110 220 415
DC 24 48 110 220 -
Note:1 To complete the ordering code ref. replace the
t symbol ( ) the code corresponding to the voltage.
2. For other coil voltages please contact our nearest Sales Office.
t
t
t
t
Power ContactorSeries CL - 3 Pole, AC Control
25 12 9 4 5.5 1 0 t585§CL00A310T
25 12 9 4 5.5 0 1 t585§CL00A301T
25 18 12 5.5 7.5 1 0 t650§CL01A310T
25 18 12 5.5 7.5 0 1 t650§CL01A301T
32 25 18 7.5 10 1 0 t740§CL02A310T
32 25 18 7.5 10 0 1 t740§CL02A301T
45 32 25 11 15 1 0 t950§CL25A310T
45 32 25 11 15 0 1 t950CL25A301T
60 40 32 16 20 1 0 t1980§CL04A310M
60 40 32 16 20 0 1 t1980CL04A301M
60 50 40 22 30 1 1 t3050§CL45A311M
90 65 50 25 35 1 1 t3700§CL06A311M
110 80 65 37 50 1 1 t5050§CL07A311M
110 95 80 45 60 1 1 t6300§CL08A311M
140 105 95 50 68 1 1 t7350§CL09A311M
140 110 105 55 75 1 1 t8050§CL10A311M
AC1Rating
AC3-Long LifeMax. 3PhaseMotor Output
at 415V AC
Aux. ContactArrangement
CodeReference
Amps Amps KW HP NO NCAmps
AC3Normal
Life
AC3LongLife
Series CK - 3 Pole, AC Control
250 185 150 80 110 1 1 CK75CA311t11450§
250 205 185 100 135 1 1 CK08CA311t14700§
315 250 205 125 170 1 1 CK85BA311t16300§
315 300 250 132 180 1 1 CK09BE311t19700§
450 400 309 160 220 1 1 CK95BE311t23100§
600 475 420 230 315 1 1 CK10CE311t28770§
700 630 550 315 430 1 1 CK11CE311t43000
1000 800 700 400 545 1 1 CK12BE311t72000
1250 1000 825 450 610 1 1 CK13BA311t118000
Amps Amps KW HP NO NC
Max. 3PhaseMotor Outputat 415V AC
Aux. ContactArrangement
CodeReference
Special Application contactors for Steel Plants available on request.Please contact our nearest Sales Office.
AC1Rating
AC3Rating
Norma Life
AC3Rating
Long Life
Amps
Coil Voltage Codes - AC
t D J N § U W
50Hz 24 110 230 380 415
160 130 125 1 1 t9700CL12A311M65 85
200 140 130 1 1 10800§CL13A311M70 95
NEW CL12-13
Buy Log/Unit
Buy Log/Unit
Buy Log/
Unit
Buy Log/
Unit
Buy Log/
Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
*Note: In case of electronic coil module, please suffix 'U' for 380 / 415V.
*
t
AC-3Rating
Long Life
Long LifeMax. 3 PhaseMotor Output
at 415 AC
Aux. ContArrangement
CodeReference
Series CL - 3 Pole, DC Control
Amps KW HP NO NC
Coil Voltage Codes - DC
t D J N
DC 24 110 220
* This CK range fitted with Electronic Module can be used both forAC and DC control.
Note1. To complete the ordering code ref. replace the symbol ( ) by the code corresponding to the voltage.2. For other coil voltages please contact our nearest sales office.
AC1Rating
at 415V
AdmissiblePower AC 1
Aux. ContArrangement
CodeReference
Series CK - 4 Pole, AC Control
Amps KW NO NC
200 143 1 1 CK07BA411 17000
325 233 1 1 CK08BA411 24000
400 287 1 1 CK09BE411 33000
500 359 1 1 CK95BE411 41600
600 431 1 1 CK10CE411 58500
700 503 1 1 CK11CE411 61000
1000 719 1 1 CK12BE411 84500
1250 898 1 1 CK13BA411 215000
Coil Voltage Codes - AC
t D J N U W
50Hz 24 110 230 380 415
Controlgear
B7
AC1Rating
at 415V
AdmissiblePower AC 1
Aux. ContArrangement
CodeReference
Series CL - 4 Pole, AC Control
Amps KW NO NC
25 18 0 CL01A400T 790¾
32 23 CL02A400T 920¾
40 25 GCL25A400T 1400¾
45 32 CL03A400M 1920¾
60 43 CL04A400M 3400¾
90 64 CL05A400M 6100
110 79 CL07A400M 7250
140 100 CL09A400M 9800
AC 3Rating
Normal Life
Amps
AC-3Rating
Long Life
Long LifeMax. 3 PhaseMotor Output
at 415 AC
Aux. ContArrangement
CodeReference
Series CK - 3 Pole, DC Control
Amps KW HP NO NC
185 150 80 110 1 1 CK75CE311 14000
205 185 100 135 1 1 CK08CE311 18000
250 205 125 170 1 1 CK85BE311 19500
300* 250 132 180 1 1 CK09BE311 19700
400* 309 160 220 1 1 CK95BE311 23100
475* 420 230 315 1 1 CK10CE311 28770
630* 550 315 430 1 1 CK11CE311 43000
800* 700 400 545 1 1 CK12BE311 72000
AC-3Rating
Normal Life
Amps
12 9 4 5.5 1 0 CL00D310T
18 12 5.5 7.5 1 0 CL01D310T
25 18 7.5 10 1 0 CL02D310T
32 25 11 15 1 0 CL25D310T
32 25 11 15 1 0 CL03D310M
40 32 16 20 1 0 CL04D310M
50 40 22 30 1 1 CL45D311M
65 50 25 35 1 1 CL06E311M
80 65 37 50 1 1 CL07E311M
95 80 45 60 1 1 CL08E311M
105 95 50 68 1 1 CL09E311M
110 105 55 75 1 1 CL10E311M
910
1020
1100
2250
2700
3250
3950
5600
6250
7600
9200
10800
160 CL12A400M 11900
200 CL13A400M 13300
110
143
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
3. All current ratings are at 415VAC, 50HZ.
NEW CL12-13
0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
0 0
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
t
IthCurrent
kVAR Ratingat 415 V AC
Aux. ContArrangement
CodeReference
Series CSC-3 Pole, AC Control
Amps kVAR NO NC
25 8 1 1 CSC08A311 1400
25 13 1 1 CSC12A311 1460 n
32 17 1 1 CSC16A311 1950
45 21 1 1 CSC20A321 2100
45 26 2 1 CSC25A321 2625 n
60 31 2 1 CSC30A321 5200
90 47 1 1 CSC45A311 7150
110 57 1 1 CSC55A311 8200
140 73 1 1 CSC70A311 11500
Amps
Power Contactor for Capacitor Switching
Coil Voltage Codes - AC
t D J N W § 7
50Hz 24 110 230 415 240v
(Wide Band)
Note:1. To complete the ordering code ref. replace the symbol ( ) by the code corresponding to the Voltage.
Controlgear
B8
Pneumatic Timer Block
For usewith
Mounting Type TimeCodeRef.
RL4R..
CL00..
CL13
Frontal
Frontal
Delayed
ON
Delayed
OFF
1350
1NO+1NC 0.1..30S BTLF30C
1NO+1NC 1..60S BTLF60C
1NO+1NC 0.1..30S BTLF30D
1NO+1NC 1..60S BTLF60D
Mechanical Latch Blocks
For use with Code Ref.
RL4R..,CL00..CL13 RMLF 1600
ContactArrange-
ments
t
t
t
t
t
t
t
t
t
t
t
Accessories for RL/CL/CK Contactor
Instantaneous and Timed Auxiliary Contact Block
For Usewith
MountingContactArrange-
ment
CodeReference
RL4RCL00..CL13 Front
1NO Instantaneous BCLF10 70n1NC Instantaneous BCLF01 7 n0
1NO Make early BCLF10G(3) 155
1NC Break late BCLF01G(3) 155
1NO+1NC BCLL11 275
2NO Instantaneous BCLL20 275n
1NO+1NC BRLL11 275
2NO Instantaneous BRLL20 275
(1). First side mounted block.
(2). Second side mounted block.
(3). BCLF 10G and BCLF01G are ‘Make Before’ (NO) and
‘Break After’ (NC) auxiliary contacts.
Note:a) Maximum number of auxiliary contacts is Four for RL4R..CL00 to CL25 Six for CL03 to CL13 Eight for CL06 to CL13 Eight for CK75 to CK13
Coil Voltage Codes - AC/DC
t D G J N U
50Hz 24 - 110 220 415/440
DC 24 48 - - -
Note:1. To complete the ordering code ref. replace the symbol ( ) by the code corresponding to the voltage.
Type
RL 4R..CL00..CL13CK75..CK13
(1)Side
(2)Side
t
Instantaneous
Instantaneous
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
Mechanical Interlock
Accessories for RL/CL/CK Contactors
For use with MountingCode
Reference
RL4R..CL00..CL13 Side BELA 275
Side BELA02* 790
CK07..CK12B Side BEKH 1600CK75C..CK95B Vertical BEKVS 4200
CK10..CK11..CK13 Vertical BEKVA 4400
CK13.. Vertical BEKV 5200
*Also with inbuilt 2NC contacts for Electrical Interlock.
Directly connected parallel to the coil terminals A1-A2
Transient Voltage Supressor Block
For use withControlCircuit
Type CodeReference
AC
AC/DC
RL4RCL00..CL45
CL00..CL13RL4R
R/C
Varistor
12Vto48V BSLR2G 375
50Vto 127V BSLR2K 375
130Vto250V BSLR2R 37524Vto48V BSLV3G 400
50Vto127V BSLV3K 400
130Vto250V BSLV3R 400
277Vto500V BSLV3U 400
Electronic Timer Module
ControlCircuit
For use with
TypeCode
Reference
RL4AR..CL00..CL13
24-250VAC/DC
DelayedON
DelayedOFF
0.1...2S BETL02C 1680
1.5..45S BETL45C 1680
0.1...3S BETL02D 1680
1..60S BETL45D 1680
Instantaneous Auxiliary Contact Block
Accessories for Series M Contactors
1165
1450
Electronic Timer Block
ControlCircuit
For use with
TypeCode
Reference
MCR..,MCO..,MC
24-250v
AC/DC
DelayedON
DelayedOFF
0.5-60S
0.2-24S MREBE20AC2
MREBC10AC2
Directly connected parallel to the coil terminals A1-A2
Transient Voltage Supressor Block
MCRA..,
MCOA.,MC1A
For use with ControlCircuit
TypeCode
Reference
AC R/C
VaristorD CMCRA..,
MCOC.,MC1C
12V to 60V MPOAAE1 325
110V to 240V MPOAAE2 325
6V to 250V DC MPOCAE3 325
Controlgear
B9
U e
Time
For usewith
CodeReferenceMounting
Number ofContacts
ContactArrangement
MCRA..MCRC..MCOA..MC1A..MCOC..MC1C..
Front
2 2 0 MARN220AT 2602 1 1 MARN211AT 260
2 0 2 MARN202AT 2604 4 0 MARN440AT 370
4 3 1 MARN431AT 3704 2 2 MARN422AT 370
4 1 3 MARN413AT 370
4 0 4 MARN404AT 370
Time
U e
Kit comprising Mechanical interlock and Contactor jointing parts
Mechanical Interlock
For usewith
Type ContactArrangement
MCR..,MCO.,MC1 Mechanical Nil MMHO 275
CodeReference
NO NC
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
Controlgear
Spares for the Air Break Contactors
Contact Kits
For use withNo. of
Sets (1)Type
Note:
1 One set consists of 2 fixed contacts, one moving contact and accessary parts
CL00 3 NO V31200B 320CL01 3 NO V31201B 395
CL02 3 NO V31202B 440CL25 3 NO V31225B 470
CL04 3 NO V31204B 720CL45 3 NO V31245B 1670
CL06 3 NO V31206B 1920CL07 3 NO V31207B 2420
CL08 3 NO V31208B 3190CL09 3 NO V31209B 3950
CL10 3 NO V31210B 4600CK07B.. 1 NO V1107BA 1900
CK75C.. 1 NO V1175CA 2125
CK08C.. 1 NO V1108CA 2450
CK85B.. 1 NO V1185BA 2790CK09B.. 1 NO V1109BA 3430CK95B.. 1 NO V1195BA 3950
CK10C.. 1 NO V1110CE 5650
CK11C.. 1 NO V1111CE 6600CK12B.. 1 NO V1112BA 11000CK13B.. 1 NO V1113BA 16000
Spare Coil - AC & AC/DC
For use with ControlType
CircuitCode
Reference
Spare Coil - Pure DC
For use withCode
Reference
MCRC..,MCOC..,MC1C MB0C
RL4RD..,CL00D to CL25D LB1D
CL03D.. to CL45D LB3D
CL06..to CL10EL LB4E
450
900
1300
2950
Coil Voltage Codes - AC/DC
Note:
1. To complete the ordering code ref. replace the symbol
( ) by the code corresponding to the voltage.
2. Coils KB4E, KB5E, KB6E, KB7E to be used with electronic
module type KM4E, KM5E, KM6E, KM7E respectively.
3. For other coil voltages please contact our nearest
sales office.
D J N
AC/DC 24 110 220
Coil Voltage Codes - AC
nD J N W 7
50Hz 24 110 230 415 240V
Coil Voltage Codes - DC
Note:1. To complete the ordering code ref. replace the symbol ( ) by the code corresponding to the voltage
D J N
DC 24 110 220
B10
CodeReference
MCRA.. (Mini) AC Coil MBOA 330
RL46..,CL00A to CL25A
CSC12A.. to CSC25A AC Coil LBA1A 330
CL03A.. to CL45A..,CSC30A AC Coil LB3A 720
CL06A.. to CL13A..,
CSC45A AC Coil LB4A 1100
to CSC70A
CK75CA3.. to CK08CA3 AC Coil C12168 1700
CK75CE3.., CK08CE3.. Coil KB4E 1700
AC/DC Electronic KM4E 3700
Module
CK85BA3..,CK07BA4 AC Coil C04255 1950
CK08BA4 AC Coil C04787 2500CK85BE3..,CK09BE3.., AC/DC Coil KB5E 3650
CK95BE3 Electronic KM5E 4500
Module
CK10CE3..,CK11CE3, AC/DC Coil KB7E 5600
CK10CE4.. CK11CE4.. Electronic KM7E 4600
Module
CK12BE3..,CK09BE4.., AC/DC Coil KB6E 5600
CK95BE4 Electronic KM6E 4500
Module
CK13BA3 AC Coil C08998 16500
CK08B.. 1 NO V1108B4 2750
t
t
t
t
t
t
t
t
t
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
Controlgear
B11
Series RT1
For use withSetting Range Code
ReferenceA (Min.) A (Max.)
CL00. to CL45
0.16 0.26 RT1B 8700.25 0.41 RT1C 8700.4 0.65 RT1D 870
0.65 1.1 RT1F 870n1.0 1.5 RT1G 870n1.3 1.9 RT1H 870n
1.8 2.7 RT1J 870n
2.5 4.0 RT1K 870n4.0 6.3 RT1L 870n
5.5 8.5 RT1M 870n
8.0 12 RT1N 870n
10.0 16 RT1P 870n14.5 18 RT1S 950n17.5 22 RT1T 950n21.0 26 RT1U 950n
25.0 32 RT1V 1425n30.0 40 RT1W 1425n
Series RT2
CL06.,toCL13.,
11.5 15 RT2A 207514.5 19 RT2B 2075
18.5 25 RT2C 2075
24.0 32 RT2D 207530.0 43 RT2E 2075 n42.0 55 RT2G 2075
54.0 65 RT2H 260064.0 82 RT2J 260078.0 97 RT2L 260090.0 110 RT2M 2600
On Delay Timer
DescriptionCode
Reference
Multirange /Multivoltage timer,2 C/O-3Secs/30Secs3 mins / 30 mins,24V to 240V AC/DC
HODT2COZ n1100
Star Delta Timers
Electronic Timers
DescriptionCode
Reference
0 - 30 secs, 230V AC, 2 C/O HSDT2CON 990 n0 - 30 secs, 415V AC, 2 C/O HSDT2COW 990 n
Thermal Overload relays
Series RT0 Series RT3
For use withSetting Range Code
Reference
CK75.,CK08
55 8063 9090 120
110 140140 190
RT3BRT3CRT3D
RT3ERT3F
380038003800
38003800
Series RT4
CK85.,CK09CK95
120 190 RT4N 6600175 280 RT4P 6600200 310 RT4R 6600
Series RT5
CK10-CK12
120 190 RT5A 6800175 280 RT5B 6800250 400 RT5C 8600
315 500 RT5D 8600
430 700 RT5E 8600
A (Min.) A (Max.)
Accessories
CodeReference
Separate mounting base for RT1 Relays RTXP 300n
Separate mounting base for RT2 Relays RT2XP 460
Setting range cover protection for RT range RTX3 220
Remote reset kit for RT range (cable length 0.5 Mtr.) RTXS 1400
Remote reset kit for RT range (cable length 1Mtr.) RTXSL 2200
Remote electrical reset kit for RT range RTXRRB 1700
Description
*RTO Relays are available in contactor mounting version only.
Setting Range
RT0G1.5 740
RT0J2.2 740
RT0H3.3 740RT0K4.8 740
RT0L7.0 740RT0M10.0 740RT0P15.0 740
RT0S20.0 790RT0U28.0 790
1.0
1.5
2.2 3.2
4.7 6.710.0
14.0 19.0
For usewith A (Min) A (Max)
Code Ref
CL00 toCL25
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
Frame 1
Surion MPCB Standard offer
RatingHigh Performance
ThermomagneticRatingCode
0.1-0.16,100kA GPS1BHAA0.16-0.25A,100kA GPS1BHAB
0.25-0.4A,100kA GPS1BSAC GPS1BHAC
0.4-063A,100kA GPS1BSAD GPS1BHAD
0.63-1A,100kA GPS1BSAE GPS1BHAE1-1.6A,100kA GPS1BSAF GPS1BHAF
1.6-2.5A,100kA GPS1BSAG GPS1BHAG
2.5-4A,100kA GPS1BSAH GPS1BHAH4-6.3A,100kA GPS1BSAJ GPS1BHAJ
6.3-10A,100kA GPS1BSAK GPS1BHAK
9-13A,50kA GPS1BSAL GPS1BHAL11-16A,25kA GPS1BSAM GPS1BHAM14-20A,25kA GPS1BSAN GPS1BHAN19-25A,25kA GPS1BSAP GPS1BHAP
25-32A,25kA GPS1BSAR
24502450
2450
2520
25752575
2800
2800
2800
3050
3150315034003400
4500GPS1BHAR
18501850
1850
2080
21502150
2150
2150
2150
2200
2415 2 4152600 3050
4200
Frame 2
RatingStd. Thermomagnetic High Performance
Thermomagnetic
CodeRating
Code6-10A,100kA GPS2BSAK GPS2BHAK 5150
9-13A,50kA GPS2BSAL GPS2BHAL 5350
11-16A,25kA GPS2BSAM GPS2BHAM 5350
14-20A,25kA GPS2BSAN GPS2BHAN 5700
19-25A,25kA GPS2BSAP GPS2BHAP 5800
24-32A,25kA GPS2BSAR GPS2BHAR 5950
28-40A,25kA GPS2BSAS GPS2BHAS 6400
35-50A,25kA GPS2BSAT GPS2BHAT 740045-63A,25kA GPS2BSAU GPS2BHAU 7700
Controlgear
B12
0.1-0.16,100kA0.16-0.25A100kA
0.25-0.4A,100kA
0.4-063A,100kA
0.63-1A,100kA
1-1.6A,100kA
1.6-2.5A,100kA
2.5-4A,100kA4-6.3A,100kA
6.3-10A,100kA
9-13A,100kA 11-16A,50kA14-20A,50kA19-25A,50kA
25-32A,50kA
6-10A,100kA
9-13A,50kA
11-16A,50kA
14-20A,50kA
19-25A,50kA
24-32A,50kA
28-40A,50kA
35-50A,50kA45-63A,50kA
Std. Thermomagnetic
CodeGPS1BSAAGPS1BSAB
3750
3750
3750
4000
5000
5000
5950
68506850
Accessories
Note:
1 For other Accessories Viz. Lug busbar, 3 Pole bar, Conversion kit , etc., please contact our nearest sales office.
2 *-Please mention coil code J-110V, N-220V, W-415-440V XXX & YY Contact Combination 10-NO, 01-NC, 20-2NO
Description Code Reference
Black external control IP55 x GPS 1 H GPA1HAB
Black external control IP55 x GPS 2 GPA2HAB
Front auxiliary block 1NO/1NC x GPS 1./GPS2 GPAC10FBA
Side contact block left 1NO+1NC GPS1./GPS2 GPACXXLLA
Side contact block right 1NO+1NC GPS1./GPS2 GPACXXLRA
Alarm contact block frontal 1NO GPS1./GPS2 GPALXXFRA
Side aux. cont. block Alarm + Aux GPS1./GPS2 GPADXXYYLL
Shunt trip (right) GPS1/GPS2 GPASLRAA*
Undervolt. relay (right) GPS1/GPS2 GPAULRAA*
Enclosure (extern). IP41 + acces. x GPS1*S Surface Mounting GPES41A*
Enclosure (extern). IP55 + acces. x GPS1*S Surface Mounting GPEES55A
Enclosure (inside). IP41 + acces. x GPS1*S Flush Mounting GPEF41A
Enclosure (inside) IP55 + acces. x GPS1*S Flush Mounting GPEF55A
950
950
400
425
425
425
600
1150
1150
500
600
500
600
Buy Log/ Unit
Buy Log/ Unit
Buy Log/ Unit
Buy Log/ Unit
Buy Log/ Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
Low Voltage Fuselinks
tDIN type, 6A to 630A, 500V AC in sizes 000,00,1,2 & 3
tBS type, 2A to 800A, 415V/660V AC in ‘Bolted’ and ‘Clip-on’ Versions
tOnly manufacturer of 660V fuselinks
Salient features
tConforms to IS 13703 - 1 & 2-1993/IEC269/BS88
tLow Let thru energy & Low Watt loses
tNon deteriorating-retain characteristics till the fuse operates on fault, irrespective of time
tPositive discrimination between upstream and downstream devices
tAlso available special fuses for signaling circuits in ferrule construction
HBC Fuselinks for Protection of Semiconductor devicesType GS
tConforms to IS 13703-4
tFast and super fast acting fuselinks for rectifier and thyristor protectionusing silver elements of proven design
tWide voltage range from 240V to 1000V, current rating 5A to 1200A
tFor Fuse operation indication, trip indicator fuses can be used along withmicro switch mounting kits
tSingle & multibody construction
Type PSC*
tAmerican Standard
- with blade contacts
50A - 2500A, 500 to 700V AC
63A - 1100A, 1000 to 1330V AC
- without blade contacts
63A - 2500A, 500 to 700V AC
63A - 1100A, 1000 to 1300V AC
tDIN Standard
- with blade contacts
63A - 1400A, 660 to 1200V AC
63A - 1100A, 900 to 1200V AC
* For Prices contact our nearest Sales Office
High Voltage HBC Fuselinks
tConforms to IS 9385/BS 2692/IEC 282-1
tHigh Voltage HBC Fuselinks for 11/6.6/3.3kV for backup protection
tType K-KEBXO/KEMXO Fuselinnks for 11kV circuits (max. service voltage12kV rms for use in oil to protect distribution circuit)Ferrule type construction having lengths 254/359 mmalso suitable for use in 7.2kV system
tType H2CAS/H3CAS Fuselinks with tag arrangement for use in air fordistribution and capacitor circuits of 11kV rating
tType K-3.3kV/6.6kV Fuselinks for use in air, for motor startingapplications (for max voltage 3.6/7.2kV) have single and double bodyconstruction.For 3.3kV,630A & for 6.6kV 400/500/630A have double body construction
tType VTF for Voltage Transformer/PT protection - 6.6kV/11kV rating
Moulded Fuse holders and Fuse base for 415V AC Circuits
tType NS/SM Fuse holders - 20A to 125A (BS)NSH/SM-H for front cable connectionNSB/SM-B for busbar/cable connectionNSP -for back stud connection
tType safe clip use holders - 20A to 63A (BS) fully shroudedsuitable for DIN rail mounting
tISG Fuse Bases for DIN Fuses/6A to 630A
tCompact 3 Phase Fuse Base ISG for DIN Fuses upto 160A
HBC Fuselinks for Industrial Application
tFrench Standard
- with blade contacts
63A - 1400A, 660V AC
63A - 1100A, 900 to 2100V AC
- without blade contacts
63A - 500A, 450 to 660V AC
63A - 1800A, 600 to 1250V AC
315A - 3600A, 550 to 1200V AC
Fusegear
C14
Most trusted for over three decadesWidest Fuse range - Fuse for every application
Low Voltage Components - Buy Log Effective from 29.12.2008
Rating List Code CartonAmp No. Reference Qty.
HBC Fuselinks for Industrial Application
DIN Type Fuselinks (Blade Contacts)
Type VS-500 V AC
Size 000
6 VSA6 SFD850000610 VSA10 SFD8500010
16 VSA16 SFD850001620 VSA20 SFD8500020
25 VSA25 SFD850002532 VSA32 SFD850003236 VSA36 SFD850003650 VSA50 SFD8500050
63 VSA63 SFD8500063
6 190 n
275 n
325 n
350 n
Size 00
6 VSB6 SFD8310006
8 VSB8 SFD8310008
10 VSB10 SFD8310010
16 VSB16 SFD8310016
20 VSB20 SFD8310020
25 VSB25 SFD8310025
32 VSB32 SFD831003236 VSB36 SFD8310036
50 VSB50 SFD8310050
63 VSB63 SFD8310063
80 VSB80 SFD8310080
100 VSB100 SFD8310100
125 VSB125 SFD8310125
160 VSB160 SFD8310160
6
6
6
478 n
500 n540 n
Size 1
3
33
36 VSF36 SFD8330036
50 VSF50 SFD8330050
63 VSF63 SFD8330063
80 VSF80 SFD8330080
100 VSF100 SFD8330100
125 VSF125 SFD8330125160 VSF160 SFD8330160
200 VSF200 SFD8330200250 VSF250 SFD8330250
1100 n
Size 3
315 VST315 SFD8350315
355 VST355 SFD8350355400 VST400 SFD8350400500 VST500 SFD8350500630 VST630 SFD8350630
1100 n
1
1
695 n
Size 2
250 VSK250 SFD8340250
315 VSK315 SFD8340315355 VSK355 SFD8340355400 VSK400 SFD8340400
714 n
1
1
34 n
37 n
41 n
51 n
BS Type Fuselink
Type SS/NS/ES
Clip-on Fuselinks with Staggered Tags - 415 V AC
Rating List Code CartonAmp No. Reference Qty.
53 n
20
20
20
20
20
2 SS2 SFA81060024 SS4 SFA8106004
6 SS6 SFA810600610 SS10 SFA810601016 SS16 SFA810601620 SS20 SFA8106020
2 NS2 SFA93110024 NS4 SFA9311004
6 NS6 SFA931100610 NS10 SFA931101016 NS16 SFA931101620 NS20 SFA9311020
25 NS25 SFA9311025
32 NS32 SFA93110322 ES2 SFA81210024 ES4 SFA8121004
6 ES6 SFA812100610 ES10 SFA812101016 ES16 SFA8121016
20 ES20 SFA8121020
25 ES25 SFA812102532 ES32 SFA812103236 ES36 SFA8121036
50 ES50 SFA8121050
63 ES63 SFA8121063
53
62
66
Type EIT
Fuselink with Offset Tags
(2 hole fixing-Bolted) - 415 V AC
20
20
20
2 EIT2 SFA81200024 EIT4 SFA8120004
6 EIT6 SFA812000610 EIT10 SFA812001016 EIT16 SFA8120016
20 EIT20 SFA812002025 EIT25 SFA812002532 EIT32 SFA8120032
36 EIT36 SFA812003650 EIT50 SFA8120050
63 EIT63 SFA8120063
Fusegear
C15
Buy Log/UnitBuy Log/
Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
Type T - 660 V ACOffset Tags (2 hole fixing - Bolted)
Rating List Code CartonAmp No. Reference Qty.
10 54 n
6 TIA6 SFB8116006
10 TIA10 SFB811601016 TIA16 SFB811601620 TIA20 SFB811602025 TIA25 SFB8116025
32 TIA32 SFB811603236 TIS36 SFB8124036
50 TIS50 SFB812405063 TIS63 SFB812406380 TCP80 SFB8125080
100 TCP100 SFB8125100
125 TFP125 SFB8126125
160 TFP160 SFB8126160200 TFP200 SFB8126200
10 98 n
6 201 n
3 326 n
38 n
75 n
127 n
134 n
202 n
Type TS - 415 AC
Offset Tags (2 hole fixing - Bolted)
Rating List Code CartonAmp No. Reference Qty.
6 TSA6 SFB8316006
10 TSA10 SFB831601016 TSA16 SFB8316016
20 TSA20 SFB831602025 TSA25 SFB831602532 TSA32 SFB8316032
36 TSS36 SFB832303650 TSS50 SFB8323050
63 TSS63 SFB832306380 TSDS80 SFB8324080
100 TSDS100 SFB8324100125 TSDS125 SFB8324125
80 TSD80 SFB8328080100 TSD100 SFB8328100
125 TSD125 SFB8328125125 TSFP125 SFB8327125
160 TSFP160 SFB8327160200 TSFP200 SFB8327200
20
20
10
10
10
165 n10
165 n10
142 n
Central Tags (2 hole fixing - Bolted)
192 n
259 n
287 n
578 n
625 n
956 n
1208 n
10
10
10
10
1
1
1
1
80 TSDC80 SFB8337080100 TSDC100 SFB8337100
125 TSF125 SFB8340125160 TSF160 SFB8340160
200 TSF200 SFB8340200250 TSF250 SFB8340250
250 TSK250 SFB8345250315 TSK315 SFB8345315
355 TSMS355 SFB8361355400 TSMS400 SFB8361400
450 TSTS450 SFB8366450500 TSTS500 SFB8366500
560 TSLS560 SFB8371560630 TSLS630 SFB8371630
670 TSLS670 SFB8371670710 TSLS710 SFB8371710
750 TSLS750 SFB8371750800 TSLS800 SFB8371800
10 186 n
1 478
751
761
1092 n
1323 n
Central Tags (4 hole fixing - Bolted)
1
1
1
1
355 TSM355 SFB8360355400 TSM400 SFB8360400450 TST450 SFB8365450500 TST500 SFB8365500
560 TSL560 SFB8370560
630 TSL630 SFB8370630670 TSL670 SFB8370670710 TSL710 SFB8370710
750 TSL750 SFB8370750800 TSL800 SFB8370800
205 n
310 n
457 n
6
3
1
Central Tags (2 hole fixing - Bolted)
80 TC80 SFB813508080 102TC80 SFB8136080
100 TC100 SFB8135100100 102TC100 SFB8136100
125 TF125 SFB8140125
160 TF160 SFB8140160200 TF200 SFB8140200250 TF250 SFB8141250
250 TKF250 SFB8145250315 TKF315 SFB8145315
982
1030 n
1360 n
1650
Central Tags (4 hole fixing - Bolted)
1
1
1
1
355 TM355 SFB8160355400 TM400 SFB8160400
450 TTM450 SFB8165450500 TTM500 SFB8165500
560 TTM560 SFB8165560630 TTM630 SFB8165630
630 TLM630 SFB8170630670 TLM670 SFB8170670
710 TLM710 SFB8170710750 TLM750 SFB8170750
800 TLM800 SFB8170800
Fusegear
C16
Buy Log/Unit
Buy Log/Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
120 n
230 n
404
520
788
1008
136
265
500
625 n
977
1205
1985
HBC Fuselink for Protection ofSemiconductor Devices
Type GS Fuselink for Diode Protection
Rating List Code CartonNo. Reference Qty.Volt. Amp
10
10
6
6
6
6
10
10
6
6
6
6
3
250VAC
250VAC
690VAC
800VAC
5 GSA5 SFE8110005G10 GSA10 SFE8110010G
15 GSA15 SFE8110015G20 GSA20 SFE8110020G
25 GSA25 SFE8111025G50 GSA50 SFE8111050G
75 GSA75 SFE8111075G100 GSA100 SFE8111100G
150 GS450/150 SFE8120150G200 GS450/200 SFE8120200G
250 GS450/250 SFE8120250G300 GS450/300* SFE8120300G400 GS450/400* SFE8120400G500 GS450/500* SFE8120500G
5 GSB5 SFE8130005G10 GSB10 SFE8130010G
15 GSB15 SFE8130015G20 GSB20 SFE8130020G
25 GSB25 SFE8130025G45 GSB45 SFE8130045G
50 GSB50 SFE8130050G75 GSB75 SFE8130075G
100 GS1000/100 SFE8131100G150 GS1000/150 SFE8131150G
200 GS1000/200 SFE8131200G250 GS1000/250 SFE8131250G
300 GS1000/300* SFE8131300G400 GS1000/400* SFE8131400G
500 GS1000/500 SFE8131500G
500 RGS500 SFE8140500
310 n
672 n
1071 n
1250
1281 n
Type GSG Fast acting Fuselink for Tyristor Protection
10
5
6
3
3
690VAC
16 GSG1000/16* SFE8230016G25 GSG1000/25* SFE8230025G
30 GSG1000/30* SFE8230030G35 GSG1000/35* SFE8230035G
40 GSG1000/40* SFE8230040G45 GSG1000/45* SFE8230045G
55 GSG1000/55* SFE8230055G75 GSG1000/75* SFE8231075G
85 GSG1000/85* SFE8231085G110 GSG1000/110* SFE8231110G
150 GSG1000/150* SFE8231150G175 GSG1000/175 SFE8232175G
200 GSG1000/200 SFE8232200G235 GSG1000/235 SFE8232235G
300 GSG1000/300 SFE8232300G325 GSG1000/325 SFE8232325G
350 GSG1000/350 SFE8232350G
Type GSM Ultra-fast acting multibody Fuselink for
Diode & Thyristor Protection
Rating List Code CartonNo. Reference Qty.Volt. Amp
800VAC
1000VAC
Note: For special tags please contact our sales office
63 GSMJ63 SFE8340063 1 410
120 GSMJ120 SFE8340120 1 950
180 GSMJ180 SFE8340180 1 1444240 GSMJ240 SFE8340240 1 1848300 GSMJ300 SFE8340300 1 2132350 GSMJ350 SFE8340350 1 2835
400 GSMJ400 SFE8340400 1 3329460 GSMJ460 SFE8340460 1 3654
520 GSMJ520 SFE8340520 1 4011580 GSMJ580 SFE8340580 1 4851
630 GSMJ630 SFE8340630 1 5440680 GSMJ680 SFE8340680 1 5775
800 GSMJ800 SFE8340800 1 77601000 GSMJ1000 SFE8341100 1 9849
1200 GSMJ1200 SFE8341120 1 1100463 GSMK63 SFE8350063 1 473
120 GSMK120 SFE8350120 1 1024180 GSMK180 SFE8350180 1 1454
240 GSMK240 SFE8350240 1 2090300 GSMK300 SFE8350300 1 2389
350 GSMK350 SFE8350350 1 3008400 GSMK400 SFE8350400 1 3622
460 GSMK460 SFE8350460 1 4016520 GSMK520 SFE8350520 1 4904
580 GSMK580 SFE8350580 1 5245630 GSMK630 SFE8350630 1 5807680 GSMK680 SFE8350680 1 6526
800 GSMK800 SFE8350800 1 81901000 GSMK1000 SFE8351100 1 115451200 GSMK1200 SFE8351120 1 12595
Fuselink Trip Indicator
List Code CartonNo. Reference Qty.
Volt. / Amp
è500/700 V AC TI300 SFB9101300 20 155 n
è707/1000 V AC TI600 SFB9101600 20 200 n
è800/1200 V AC TI1200 SFB9102120 20 300
è1414/2000 V AC TI2000 SFB9102200 20 331è
RMS/Peak Voltage
è GS 450, GS 1000 & GSG 1000 type fuses are also available with
Inbuilt trip indicator
Please contact our nearest sales office for product information
Fusegear
C17
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
203
536
270
Kits for mounting Trip Indicator Fuselink
Description of Unitsrequiring kits
TripIndicator
Kit CodeReference
GSA25 to 100A TI300 SFE9000001
GS450/150-500A TI300 SFE9000002GSB25-75A TI600 SFE9000003
GSG100/25-150A/785E GSG 1000/75-150A TI600 SFE9000003GSG1000/100-500A TI600 SFE9000004GSG1000/175-350A/784E TI600 SFE9000004
Micro Switch with onechangeover contact andadaptor for fixing tripindicator Fuselinks
SFE9000005
GSM63A TI1200 SFE9000011GSMJ120-1200A/954 GSMJ400-460A/955 GSMJ
GSMK63A TI2000 SFE9000011
RGS500A TI1200 SFE9000010
GSMK120-1200A/954 GSMK400-460A/955 GSMK 520-680A
TI1200 SFE9000008
TI2000 SFE9000008
Fuselink for Distribution/Motor Circuit
Volt. AmpList Code CartonNo. Reference Qty.
Rating
7.2kVAC
50 K81SVX50 SFK8230050 1 613263 K81SVX63 SFK8230063 1 6132n80 K81SVX80 SFK8230080 1 6746n
100 K81SVX100 SFK8230100 1 7088n125 K81SVX125 SFK8230125 1 8190n160 K81SVX160 SFK8230160 1 8190n
200 K81SVX200 SFK8230200 1 9240n250 K81SVX250 SFK8230250 1 11445n315 K81SRX315 SFK8230315 1 14440
350 K81SRX350 SFK8230350 1 15435400 K82SSX400 SFK8230400 1 26040
500 K82SSX500 SFK8230500 1 28560630 K82SSX630 SFK8230630 1 30975
Fusegear
C18
Buy Log/Unit
Buy Log/Unit
12kVAC 2977 n
Type KEBXO Fuselink for Distribution Circuits
(for use in Oil)
Volt. AmpRating List Code Carton
No. Reference Qty.
5 KEBXO5 SFK8110005 110 KEBXO10 SFK8110010 1
16 KEBXO16 SFK8110016 120 KEBXO20 SFK8110020 1
25 KEBXO25 SFK8110025 136 KEBXO36 SFK8110036 1
40 KEBXO40 SFK8110040 145 KEBXO45 SFK8110045 1
50 KEBXO50 SFK8110050 163 KEBXO63 SFK8110063 1
80 KEBXO80 SFK8110080 1
Buy Log/Unit
4956
5513
5985
6773
7823
8663
1302016695
High Voltage HBC Fuselink3.6 kV Fuselink for Distribution/Motor Circuit
Volt. AmpList Code CartonNo. Reference Qty.
Rating
2888 n
n
3.6kVAC
5 K3PGX5 SFK8210005 110 K3PGX10 SFK8210010 1
16 K3PGX16 SFK8210016 1
20 K3PGX20 SFK8210020 1
25 K3PGX25 SFK8210025 132 K3PGX32 SFK8210032 1
40 K3PGX40 SFK8210040 150 K3PGX50 SFK8210050 1
63 K3PGX63 SFK8210063 1 80 K3PGX80 SFK8210080 1
100 K81PEX100 SFK8220100 1160 K81PEX160 SFK8220160 1
200 K81PEX200 SFK8220200 1
250 K81PEX250 SFK8220250 1
315 K81PEX315 SFK8220315 1350 K81PEX350 SFK8220350 1
450 K81PRX450 SFK8220450 1
630 K81PFX630 SFK8220630 1
Buy Log/Unit
3638
3801
4132
4636
Type KEMXO Fuselink for Distribution Circuit (for use in Oil)
Volt. Amp
Rating List Code CartonNo. Reference Qty.
12kVAC
5 KEMXO5 SFK9211005 1
10 KEMXO10 SFK9211010 116 KEMXO16 SFK9211016 1
20 KEMXO20 SFK9211020 125 KEMXO25 SFK9211025 1
36 KEMXO36 SFK9211036 140 KEMXO40 SFK9211040 1
45 KEMXO45 SFK9211045 1
50 KEMXO50 SFK9211050 163 KEMXO63 SFK9211063 1
80 KEMXO80 SFK9211080 190 KEMXO90 SFK9211090 1
100 KEMXO100 SFK9211100 1
120 KEMXO120 SFK9211120 1
Buy Log/Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
Type H2CAS Fuselink for Distribution Circuit (for use in Air)
List Code CartonNo. Reference Qty.Volt. Amp
Rating
12kVAC
2645 n
2790
5 H2CAS5 SFK8120005 1
6.3 H2CAS6.3 SFK8120006 110 H2CAS10 SFK8120010 1
16 H2CAS16 SFK8120016 120 H2CAS20 SFK8120020 1
25 H2CAS25 SFK8120025 131 H2CAS31 SFK8120031 1
36 H2CAS36 SFK8120036 1 40 H2CAS40 SFK8120040 1
45 H2CAS45 SFK8120045 150 H2CAS50 SFK8120050 1
56 H2CAS56 SFK8120056 163 H2CAS63 SFK8120063 1
71 H2CAS71 SFK8120071 180 H2CAS80 SFK8120080 1
90 H2CAS90 SFK8120090 1100 H2CAS100 SFK8120100 1
Type H3CAS Fuselink for Distribution Circuit (for use in Air)
List Code CartonNo. Reference Qty.Volt. Amp
Rating
12kVAC
2645
5 H3CAS5 SFK8121005 1 6.3 H3CAS6.3 SFK8121006 1
10 H3CAS10 SFK8121010 116 HECAS16 SFK8121016 1
20 H3CAS20 SFK8121020 125 H3CAS25 SFK8121025 1
31 H3CAS31 SFK8121031 136 H3CAS36 SFK8121036 1
40 H3CAS40 SFK8121040 145 H3CAS45 SFK8121045 1
50 H3CAS50 SFK8121050 156 H3CAS56 SFK8121056 1
63 H3CAS63 SFK8121063 171 H3CAS71 SFK8121071 1
Type VTF Voltage Transformer Fuselink
11 kV AC VTF11/3A SFB9103001 1 795 n11 kV AC 5XVTF11/3A SFB9103002 1 860 n
6.6 kV AC VTF 6.6/3A SFB9103005 1 765 n
BS type fuse holder - Type NS & SM: Moulded Fuse Holder
NS(upto32 A)
415VAC
32 NSH SFF8111000 Front 95 n
NSP SFF8111001 Back 100 n 10 - - -NSB SFF8111002 Busbar 100 n
32 SM32H SFF8215000 Front 155nSM32B SFF8215002 Busbar 170 n 10 - TIA TSA -
63 SM63H SFF8220000 Front 195 n 10 - TIA TSS -SM63B SFF8220002 Busbar 230n 10 - TIS - -
125 SM125H SFF8225000 Front 540 n
SM125B SFF8225002 Busbar 595 n 5 - TCP TSD -
Fusegear
Moulded Fuse Holder and Fuse Base for 415V AC CircuitType SC: Safe Clip
List Code Connection CartonNo. Reference QuantityVolt. Amp
Rating Associated HBC Fuselink
Clip onBolted Blade
Contact
*Suitable for DIN rail mounting
20 SC20H SFF8510000 Front 85 n 10 SS
32 SC32H* SFF8511000 Front 105 10 NS63 SC63H SFF8530000 Front 175 n 10 ES
415VAC
High Voltage HBC Fuselink
C19
20 SC2 H0 D* SFF8512000 Front 92 10 SS
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
16A, 32A, 63A, & 100A 3 phase Fuse distribution boards
4/8/12 way DB for 16/32/63A and 4/6/8 way DB for 100A
These use HBC fuses and Fuse holders type NS/SM
Ample cable space
Dust protection gaskets, safety phase barriers and detachable endplates at the top and bottom are standard features
Ref Standard IS 2675-1983
Fuse Distribution Board
Volt. Amp
Rating No. ofways
List No.CodeReference (excluding
Fuselinks)
Associated HBC Fuselinks
CLIP - ON
Bolted
T TS
415VAC
4 N4TN SGV8511004 4990
16 8 N8TN SGV8511008 7520 NS - -
12 N12TN SGV8511012 10640
4 SM32TN4 SGV8615004 9670
32 8 SM32TN8 SGV8615008 15590 n- TIA TSA
12 SM32TN12 SGV8615012 23240 n
4 SM63TN4 SGV8620004 13090
63 8 SM63TN8 SGV8620008 20680 n- TIA, TIS TSA, TSS
12 SM63TN12 SGV8620012 28380
4 SM100TN4 SGV8625004 23240
100 6 SM100TN6 SGV8625006 30400 - TCP TSD
8 SM100TN8 SGV8625008 33400
Fusegear
C20
DIN Type ISG Fuse Base
DIN Type ISG Fuse Base 3 Pole
160 ISG160 SFF8410000 - 240 n 3 - - - VSB250 ISG250 SFF8431000 1 3 - - - VSF
400 ISG400 SFF8441000 2 3 - - - VSK630 ISG630 SFF8451000 3 3 - - - VST
415VAC
500VAC 160 ISG160 SFF8461000 - 650 1 - - - VSB
470 n750 n970 n
Buy Log/ Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
Wall Mounting & Panel Mounting Units
Wall Mounting Type Combination Fuse Switch Unit
Type CH in Cast iron enclosures from 63A to 315A
Type CHD in sheet steel enclosures from 400A to 800A
Both CH and CHD available in 3 pole & 4 pole versions
Wall Mounting Type - Switch Fuse Unit
Sheet steel clad switch fuse unit Type LP - 32A & 63A TP & N versionwith SM fuse holders. These units have side operating handles
Range 32A to 800A, AC23A duty
Switch disconnectors and Switch disconnector fuse units available in TPN and4 pole version
Compact dimensions
Different configuration to accommodate BS, DIN and clip-on Fuselinks
Accessories - Aux switch
Door Drive - FD kits Complete with Door Interlock, Defeat and Pad locking fecility
Conforms to IS 13947-3-1993
Type CMM FSDUs
Conforms to IS 13947-3-1993
125A to 800A (AC23A) in 2 basic frame sizes
Highest current carrying capacity in their class
The units have draw-out Fuse Carriage
Lowest down time required during fuse failure and maintenance
Ideal solution for process industries, where down time is very critical
Fixed and Totally Draw out type configuration
Robust and sturdy construction - best suited for Indian conditions
Only type FSDUs with maintainable contact system
Fixed/Moving contacts available as spare
Switchgear
D21
Panel Mounting Type
Switch Disconnector Fuse Units / Fuse Switch Disconnector Units
Type SP SDFUs
Low Voltage Components - Buy Log Effective from 29.12.2008
Wall Mounting Type Combination Fuse Switch UnitType CH: Cast Iron Enclosure TPN
Volt. Amp
RatingListNo.
CodeReference (With type
TS Fuselinks)
Associated HBCFuse-links Bolted Type
Type T Type TS
415VAC
63 CH633N(U) PGH8156102 6960 TIA, TIS TSA, TSS100 CH1003N(U) PGH8160102 10440 TCP TSD, TSA
200 CH2003N(U) PGH8166102 13790 TC, TF TSDC, TSF
315 CH3153N(U) PGH8170102 18850 TC, TF, TKF TSDC, TSF, TSK
Type CH: Four Pole Fuse Switch Units in Cast Iron Enclosure
Volt. Amp
RatingListNo.
CodeReference (With type
TS Fuselinks)
Associated HBCFuse-links Bolted Type
Type T Type TS
415VAC
100 CH1004P PGH8160142 13790 TCP TSD, TSA200 CH2004P PGH8166142 19200 TC, TF TSDC, TSF
315 CH3004P PGH8170142 26100 TC, TF, TKF TSDC, TSF, TSK
Type CH: Four Pole Fuse Switch Units in EnclosureSheet Steel
Volt. Amp
RatingListNo.
CodeReference
(With typeTS Fuselinks)
Associated HBCFuse-links Bolted Type
Type T Type TS415V
AC500 CH5004P PGH8174142 53600 TTM TSM, TST750 CH7504P PGH8177142 66300 TTM, TLM TSM, TST, TSL
Type CHD: Sheet Steel Enclosure TPN
Volt. Amp
RatingListNo.
CodeReference
(With typeTS Fuselinks)
Associated HBCFuse-links Bolted Type
Type T Type TS
415VAC
400 CHD400 PGH8172102 22300 - TSMS500 CHD500 PGH8174102 34200 - TSMS, TSTS
630 CHD630 PGH8176102 36900 - TSMS,TSTS,TSLS
800 CHD800 PGH8178102 46200 - TSMS, TSTS, TSLS800 CHD800* PGH9101003 30900 - -
* Chasis without fuses
Wall Mounting Type Switch Fuse UnitsType LP: TPN Switch Fuse Units in Sheet Steel Enclosure
Volt. Amp
RatingListNo.
CodeReference
(With typeTS Fuselinks)
AssociatedFuse-links Bolted Type
Type T Type TS415V
AC32 LP303N SGG8150202 3900 n TIA TSA63 LP603N SGG8156202 4900 n TIA, TIS TSA, TSS
Switchgear
D22
Spares for LP/CH/CHD Units
Volt. Amp
Rating
CodeReference
TP Moving Contact Assembly
CodeReference
415VAC
TP Shrouded Base AssemblyCode No.
32 LP303N SGG9000001 630 SGG9000003 117063 LP603N SGG9000001 630 SGG9000004 1390
63 CH633(U) PGH9000001 2230 PGH9000012 2560
100 CH1003(U) PGH9000002 2780 PGH9000013 3610
200 CH2003(U) PGH9000003 3480 PGH9000014 5280
315 CH3153N(U) PGH9000004 5700 PGH9000060 6690400 CHD400 PGH9000062 7500 PGH9000063 9170500 CHD500 PGH9000064 11550 PGH9000065 23410630 CHD630 PGH9000066 17000 PGH9000067 25100800 CHD800 PGH9000068 17960 PGH9000069 26400
FP Moving Contact Assembly FP Shrouded Base Assembly100 CH1004P PGH9000044 4430 PGH9000047 5280200 CH2004P PGH9100045 4870 PGH9100048 6840315 CH3154P PGH9100046 8500 PGH9100061 10440
Buy Log/ Unit
Buy Log/ Unit
Buy Log/ Unit
Buy Log/ Unit
Buy Log/ Unit
Buy Log/ Unit
Buy Log/ Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
Volt. Amp
Rating
List No.
CodeReference(TPN)
CodeReference(4 Pole)SwitchedNeutral
TPN SDF’s in SS Enclosure
AssociatedHBCFuselinks
CodeReference
4th Pole asSwitched
Neutral available660V
AC
415VAC
32
63
SP32 EIT-BS BGG8359044 1230n BGG8358034 2450 EIT
SP32NS-Clip-on BGG8359144 1300 BGG8358134 2550 NS
SP63 EIT-BS BGG8361044 1730n BGG8360034 2950 EIT
SP63D - DIN BGG8361344 2050 BGG8360334 3250 VSA
SP63 ES-Clip-on BGG8361144 1950 BGG8360134 3150 ES
125SP03-BS SGG8362044 4700 SGG8362043 5950 BGG8362034 6100 TSDS
SP03 (D) - DIN SGG8362344 5100 SGG8362343 6150 BGG8362134 6500 VSB
200SP04-BS SGG8366044 5650nSGG8366043 6750 BGG8364043 7050 TSF
SP04 (D) - DIN SGG8366344 6100 SGG8366343 7350 BGG8364343 7600 VSF
250SP05-BS SGG8368044 7400nSGG8368043 8450 BGG8368034 9100 TSF
SP05 (D) - DIN SGG8368344 8000 SGG8368343 9300 BGG8368334 9800 VSF
400SP07-BS SGG8372044 11400nSGG8372043 13300 BGG8372034 13800 TSMS
SP07 (D) - DIN SGG8372344 12000 SGG8372343 13900 BGG8372334 14350 VSK
630SP630-BS SGG8374044 17800 BGG8374043 NA NA TSLS
SP630(D) - DIN SGG8374344 18700 BGG8374343 NA NA VST
800SP800-BS SGG8380044 21000 BGG8380043 NA NA TSLS
SP800(D) - DIN SGG8380344 21800 BGG8380343 NA NA -
Note : Buy Log excluding fuse links.
Type SP Switch Disconnector Fuse Units
Panel Mounting Switch Disconnector/Switch Disconnector Fuse Units/Fuse Switch Disconnector Units
Switchgear
D23
Type SP Switch Disconnector TPN
Volt. Amp
RatingList No.
CodeReference
(TPN)
690VAC
415VAC
32 SP32 BGG8459033 1175
63 SP63 BGG8461033 1550 n
125 SP03 SGG9100006 4850
250 SP05 SGG9100013 7600
400 SP07 SGG9100018 11700
630 SP630
100 SP100 4000SGG9100004
SGG9100020 Price on Request
SP100-BS SGG8363044 3800 4850 5115100
TSDS
SP100(D) - DIN SGG8363344 4300 5150 5620 VSA / VSB
SGG8363043
SGG8363343
SGG8363034
SGG8363334
160SP160-BS SGG8365044 4950 6700 6450 TSFP
SP160(D) - DIN SGG8365344 5500 7250 6750 VSB
SGG8365043
SGG8365343
SGG8365034
SGG8365334
315SP06-BS SGG8369044 9900 11450 11700 TSK
SP06 - DIN SGG8369344 10700 12400 12500 VSK
SGG8369043
SGG8369343
SGG8369034
SGG8372034
For other ratings and versions, please contact us
NEW
NEW
NEW
19200
20300
22200
23200
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
Type CMM - TPN Fixed Type FSDU
Accessories for SDF Type SP
Switchgear
D24
Volt. AmpRating List
No.
CodeReference
AssociatedHBC Fuselinks
*Buy Log excluding fuselinks
415VAC
125 CMM125 PGM8162000 6200 TC, TF TSDC, TSF
200 CMM200 PGM8166000 8300 TC, TF TSDC, TSF250 CMM250 PGM8168000 9900 TC, TF TSDC, TSF, TSK
315 CMM315 PGM8170000 12000 - TSK400 CMM400 PGM8172000 15400 - TSMS
630 CMM630 PGM8176000 23800 TTM, TLM TSM, TST, TSL800 CMM800 PGM8178000 26400 TTM, TLM TSM, TST
Buy Log/Unit
*Buy Log excluding fuselinks
Volt. AmpRating List
No.
CodeReference
TPN Withdrawable Type FSDU
AssociatedHBC Fuselinks
415VAC
200 CMM200D PGM8166400 9200 TC, TF TSDC, TSF250 CMM250D PGM8168400 11400 TC, TF TSDC, TSF, TSK
315 CMM315D PGM8170400 13900 TC, TF TSDF, TSF, TSK400 CMM400D PGM8172400 17700 - TSMS
630 CMM630D PGM8176400 27400 TTM, TLM TSMSTSM, TST, TSL800 CMM800D PGM8178400 30500 TSM, TLM TSM, TST
Buy Log/Unit
For SP 100/03/160/04/05/06/07 Code ReferenceAuxiliary Contact 1 NO SGC8308027 180Auxiliary Contact 1 NC SGC8308028 180Phase Barrier kit (SP100/03/160) SGG8900006 120Phase Barrier kit (SP04/5) - 320Phase Barrier kit (SP06/SP07) - 320FD Kit for SP 100/03/160 SGG8900041 500FD Kit for (S 4/ 5/ 6/ 7)P0 0 0 0 SGG8900042 590
Switched Neutral BGG8900035 3230
Switch handle withlegend plate & gasket BGG8900036 1190
Tubular shaft BGG8900037 330Coupler assembly BGG8900039 620
For SP630/800
*For product codes please contact our nearest Sales Office
All the FD Kits will have Door Interlocking, Defeat & Pad Locking as a standard features
Switched Neutral BGG8900027 420Auxiliary Kit (1NO+1NC) BGG8900029 320
Auxiliary Kit (1NO+1NC) only for SP63D BGG8900041 320
Front Drive Kit for SDF/Switch (Black) BGG8900031 380
Front Drive forSafety Switches (Red & Yellow) BGG8900032 420
CodeReference
For SP32/63 Buy Log/Unit
Buy Log/ Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
Spares for CMM Units
Description Code Reference Buy Log/ Unit
Front Drive Kit CMMCMM125CMM200CMM250CMM315CMM400CMM630CMM800Moving Contact CarriageCMM125CMM200CMM250CMM315CMM400CMM630CMM800Caliper Contact Assembly ( Each unit requires 6 sets)CMM125CMM200CMM250CMM315CMM400CMM630CMM800Addon 4-pole
PGM0100070PGM0100071PGM0100072PGM0100073PGM0100074PGM0100075PGM0100076
PGM0100033PGM0100035PGM0100034PGM0100036PGM0100042PGM0100043PGM0100044
PGM0100077PGM0100078PGM0100079PGM0100080PGM0100081PGM0100082PGM0100083PGM8100068
1800180018001800220022002200
45004500580058009900
1440015800
300300300300650650650
4000
On Load Changeover Switch - 4 PoleType SPCO
Conforms to IS 13947 - 3 - 1993Ratings 63 to 3150A, 4 Pole, 415V, AC23A dutyCompact in dimensionsHigh mechanical lifeLOTO - safety feature allows padlocking and tag fixingAccessories - Auxiliary contacts - upto 2 NO + NC (on request)Extendable shaft - 200mm
CodeRATING(A)
List No.Voltage
415V AC
63 SPCO 63 SGG 8601010 3750
125 SPCO 125 SGG 8601020 7100200 SPCO 200 SGG 8601030 9500
250 SPCO 250 SGG 8601040 13500320 SPCO 320 SGG 8601050 14200
400 SPCO 400 SGG 8601060 20600630 SPCO 630 SGG 8601070 24500
800 SPCO 800 SGG 8601080 35500
1000 SPCO 1000 SGG 8601090 58500
1250 SPCO 1250 SGG 8601100 820001600 SPCO 1600 SGG 8601110 114000
2000 SPCO 2000 SGG 8601120 140000
2500 SPCO 2500 SGG 8601130 186000
3150 SPCO 3150 SGG 8601140 255000
Changeover Solutions
D25
Buy Log/ Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
Moulded Case Circuit Breakers
Type Record Plus
Type TM 125/200 with adjustable Thermal Magnetic Trip release
Conforms to - IS13947-2
Rated operational voltage - 415V AC
Range, 3 Pole/4 Pole, 16A to 160 A, 415V AC
Breaking Capacity 25kA, 36kA
Field fittable accessories:
Alarm / Auxiliary switches Shunt release
Front Drive kits
Type Therm 100 with Thermal Magnetic Trip release*
Conforms to IS 13947-2
Range upto 100A, 10KA, 415V AC
1 Pole and 3 Pole versions
Circuit Breaker
Conforms to IEC 60947- 2 / IS 13947-2
Double Break contact system - exceptional current limiting, low let thru energy & high contact life
Range - 16 to 1600A
3 Pole and 4 Pole versions
Thermal Magnetic & Micro Processor based interchageable trip units
Maximum Rated Operational Voltage - 690V AC
Load Line interchangeble
Suitable for isolation
Field fittable accessories:
Alarm / Auxiliary switches Shunt release
Front Drive kits UV release
Motor Operators, Plug in & Draw out versions, Mechanical Interlocking base plates, ATS Controllers
available for complete range
Type LM
- With continuously adjustable Electronic release- With Microprocessor release
Conforms to - IS13947-2
3 Pole and 4 Pole versions
Rated operational voltage - 415V AC
3 frame sizes from 3.2 to 800A
25/35/50/65 KA breaking capacities
Field fittable accessories:
Alarm / Auxiliary switches Shunt release UV release
Earth Fault module Front Drive kits
E26
NEW
Type Spectra EZ Thermal Magnetic release*
Conforms to - IS13947-2
10A to 800A, 3 Pole/4 Pole
18kA, 25kA, 36kA, 50kA Breaking Capacity, 415VAC
Range of internal external accessories*Prices on request
Low Voltage Components - Buy Log Effective from 29.12.2008
*Prices on request
Record Plus
E27
RangeCat Ref PolesFrame / BC RelBreaking
Capacity IcuCode
4900
6100
7700
6100
7500
9500
FDS36kA
Thermo MagneticOL-(0.8-1) In
SC - Fixed
FDS35TD016ED 3 36kA 16A 430161
FDS35TD020ED 3 36kA 20A 430163
FDS35TD025ED 3 36kA 25A 430165FDS35TD032ED 3 36kA 32A 430167
FDS35TD040ED 3 36kA 40A 430169 5800FDS35TD050ED 3 36kA 50A 430178
FDS35TD063ED 3 36kA 63A 432952FDS35TD080GD 3 36kA 80A 432955
FDS35TD100GD 3 36kA 100A 432958FDS35TD125GD 3 36kA 125A 432961 7100FDS35TD160GD 3 36kA 160A 433602 8900
FDS45TD016ED 4 36kA 16A 430224
FDS45TD020ED 4 36kA 20A 430226
FDS45TD025ED 4 36kA 25A 430228
FDS45TD032ED 4 36kA 32A 430230
FDS45TD040ED 4 36kA 40A 430232 7500
FDS45TD050ED 4 36kA 50A 430241
FDS45TD063ED 4 36kA 63A 432964
FDS45TD080GD 4 36kA 80A 432967
FDS45TD100GD 4 36kA 100A 432970
FDS45TD125GD 4 36kA 125A 432973 8900
FDS45TD160GD 4 36kA 160A 433604 11200
FDE 25 kA
Thermo MagneticOL (0.8-1) inSC - Fixed
FDE35TC016EF
FDE35TC020EF
FDE35TC025EF
FDE35TC032EF
FDE35TC040EF
FDE35TC050EF
FDE35TC063EF
FDE35TC080GF
FDE35TC0100GF
FDE35TC0125GF
FDE35TC0160GF
FDE45TC016EF
FDE45TC020EF
FDE45TC025EF
FDE45TC032EF
FDE45TC040EF
FDE45TC050EF
FDE45TC063EF
FDE45TC080GF
FDE45TC100GF
FDE45TC125GF
FDE45TC160GF
3
3
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4
4
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
16A
20A
25A
32A
40A
50A
63A
80A
100A
125A
160A
16A
20A
25A
32A
40A
50A
63A
80A
100A
125A
160A
433649
433651
433653
433655
433657
433659
433661
433663
433665
433667
433669
433697
433699
433701
433703
433705
433707
433709
433711
433713
433715
433717
Thermo Magnetic Release
Thermo Magnetic Release
Buy Log/Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
Record Plus Moulded Case Circuit Breakers
Record Plus
E28
ElectricalOperator
FDEMFD Motor Mechanism 24V AC/DC 430926FDEMFF Motor Mechanism 48V AC/DC 430929
FDEMFH Motor Mechanism 60V AC/DC 430932 12000FDEMFJ Motor Mechanism 110V AC/DC 430935FDEMFN Motor Mechanism 220/250V AC/DC 430938FDEMF8 Motor Mechanism 400/440V AC 430920
* Door Flange FDFH to be ordered separately to use the Door Interlock options
RangeCat Ref PolesFrame / BC RelBreaking
Capacity IcuCode
ManualOperator
FDNRD/5 Extended / Panel or Door Mounted Rotary Handle 436476 1700
FDNRC/5 Rotory Handle through Door* 436474 1500
FDFH Flange 430829 400
ConnectionAccessories
RCDModules
RCD Bottom Mounted 3P 220/440V 431078 9800RCD Bottom Mounted 3P 400/690V 431076 9800
RCD Bottom Mounted 4P 220/440V 431084 10800RCD Bottom Mounted 4P 400/690V 431080 10800
3 Pole Spreader for FD - (set of 3) 430891 4004 Pole Spreader for FD - (set of 4) 430892 550
Phase Barrier FD - (set of 12) 430957 700FD - Plug-in System 3 Pole 430893 6500
FDQDB3HFDQDB3M
FDQDB4HFDQDB4M
FDBSS3FDBSS4
FDJPFDDDF3FDDDF4 FD - Plug-in System 4 Pole 430896 8600
8700
FDN50kA
Thermo MagneticOL-(0.8-1) In
SC - Fixed
FDN36TD016ED 3 50kA 16A 430100
FDN36TD020ED 3 50kA 20A 430101
FDN36TD025ED 3 50kA 25A 430102FDN36TD032ED 3 50kA 32A 430103
FDN36TD040ED 3 50kA 40A 430104FDN36TD050ED 3 50kA 50A 430105
FDN36TD063ED 3 50kA 63A 430106FDN36TD080GD 3 50kA 80A 430630
FDN36TD100GD 3 50kA 100A 430633FDN36TD125GD 3 50kA 125A 430636FDN36TD160GD 3 50kA 160A 433572
FDN46TD016ED 4 50kA 16A 430131
FDN46TD020ED 4 50kA 20A 430132
FDN46TD025ED 4 50kA 25A 430133
FDN46TD032ED 4 50kA 32A 430134
FDN46TD040ED 4 50kA 40A 430135
FDN46TD050ED 4 50kA 50A 430136
FDN46TD063ED 4 50kA 63A 430137
FDN46TD080GD 4 50kA 80A 430752
FDN46TD100GD 4 50kA 100A 430755
FDN46TD125GD 4 50kA 125A 430758
FDN46TD160GD 4 50kA 160A 433590
1060012800
11200
13500
16500
RangeCat Ref PolesFrame / BC RelBreaking
Capacity IcuCode
Thermo Magnetic Release
Buy Log/Unit
Buy Log/Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
Record Plus Moulded Case Circuit Breakers
Record Plus
RangeCat Ref PolesFrame / BC RelBreaking
Capacity IcuCode
FEV36kA
Thermo MagneticOL-(0.8-1) InSC-(5-10) Ir
Switchable Rating PlugOL-(0.4-1) In SC-(2-13) Ir
FEN50kA
Thermo MagneticOL-(0.8-1) InSC-(5-10) Ir
FEN50kA
Micro Processor
Adjustable Rating PlugOL-(0.625-1) In SC-(2-13) Ir
FEV36TA160KF 3 36kA 160A 436798 13200
FEV36TA200KF 3 36kA 200A 431058 13200
FEV36TA250KF 3 36kA 250A 431061 14600FEV46TA160KF 4 36kA 160A 436817 16500
FEV46TA200KF 4 36kA 200A 431094 16500FEV46TA250KF 4 36kA 250A 431097 17500FEN36TA100JF 3 50kA 100A 431757 14900
FEN36TD125KF 3 50kA 125A 432962 14900
FEN36TD160KF 3 50kA 160A 432976 16500
FEN36TD200KF 3 50kA 200A 432979 16500FEN36TD250KF 3 50kA 250A 432982 17700FEN46TA100JF 4 50kA 100A 431955 20800FEN46TD125KF 4 50kA 125A 433070 20800
FEN46TD160KF 4 50kA 160A 433076 21900
FEN46TD200KF 4 50kA 200A 433079 21900
FEN46TD250KF 4 50kA 250A 433082 22200
FEN36AA125KGF 3 50kA 125A 431920 20200
FEN36AA160KJF 3 50kA 160A 431706 20200
FEN36AA250KKF 3 50kA 250A 431709 22300
FEN46AA125KGF 4 50kA 125A 431938 24100
FEN46AA160KJF 4 50kA 160A 431793 24100
FEN46AA250KKF 4 50kA 250A 431796 27900
FERS3K250 3 Switchable Plug FE250-250A 432327 1200
FERS4K250 4 Switchable Plug FE250-250A 432378 1600
Micro Processor Release SMR 1 W/O Rating Plug
ManualOperators
FENRD/5 Extended / Panel or Door Mounted Rotary Handle 436493 1900
FENRC/5 Rotary Handle through Door* 436491 1700
FDFH Flange 430829 400
* Door Flange FDFH to be ordered separately to use the Door Interlock options
Thermo Magnetic Release
E29
FERJ3G0125 3 FE250-125 Adj Plug 125A 432192 1000
FERJ3J0160 3 FE250-160 Adj Plug 160A 432195 1000
FERJ3K0250 3 FE250-250 Adj Plug 250A 432207 1000
FERJ4G0125 4 FE250-125 Adj Plug 125A 432294 1200
FERJ4J0160 4 FE250-160 Adj Plug 160A 432297 1200
FERJ4K0250 4 FE250-250 Adj Plug 250A 432309 1200
Buy Log/Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
Record Plus Moulded Case Circuit Breakers
Record Plus
RangeCat Ref PolesFrame / BC RelBreaking
Capacity Icu
FGN50kA
Micro Processor
AdjustableRating Plug
OL-(0.625-1) InSC-(2-13) Ir
SwitchableRating PlugOL-(0.4-1) InSC-(2-13) Ir
FGN 50kAMicro Processor
ManualOperator
Code
FGN36AA400LLF 3 50kA 400A 431455 29800
FGN36AA630NNF 3 50kA 630A 431461 30800FGN46AA400LLF 4 50kA 400A 431536 36800
FGN46AA630NNF 4 50kA 630A 431539 39800
FGRJ3LL0400 3 FG400-400 Adj Plug 400A 433151 1000
FGRJ3NN0630 3 FG630-630 Adj Plug 630A 433157
FGRJ4LL0400 4 FG400-400 Adj Plug 400A 433187
FGRJ4NN0630 4 FG630-630 Adj Plug 630A 433193
FGRS3LL0350 3 FG400-400 Sw Plug 350A 435435 1200
FGRS3NN0500 3 FG630-630 Sw Plug 500A 434512 1200
FGRS4LL0350 4 FG400-400 Sw Plug 350A 434537 1400
FGRS4NN0500 4 FG630-630 Sw Plug 500A 434542 1400
FGN36AV400LLF 3 400A 436156 44000
FGN36AV630NNF 3 630A 436158 46500
FGN46AV400LLF 4 400A 436160 52000
FGN46AV630NNF 4 630A 434092 55000
FGRL3LL0400 3 FG400 - 400 Adj Plug 400A 436721 1400
FGRL3NN0630 3 FG630-630 Adj Plug 630A 436722 1400
FGRL4LL0400 4 FG400-400 Adj Plug 400A 434584 1600
FGRL4NN0630 4 FG630-630 Adj Plug 630A 434532 1600
FGNRD/5 Extended / Panel or Door Mounted Rotary Handle 436506 3000
FGNRF/5 Direct Rotary Handle 436509 2500
Micro Processor Release SMR1 w/o rating plug
Rating Plug for SMR1
Micro Processor Release SMR2 w/o rating plug
Adjustable LT & LTDRating Plug
Rating Plug for SMR2
RCDModule
ConnectionAccessories
ElectricalOperator
FEEMFD Motor Mech 24V AC/DC 432052
FEEMFF Motor Mech 48AC/DC 432055
FEEMFH Motor Mech 60AC/DC 432058FEEMFJ Motor Mech 110/130V AC/DC 432061
FEEMFN Motor Mech 220/250V AC/DC 432064
FEEMF8 Motor Mech 400/440 V AC 435812
FEBSS3 3 Pole Spreader for FE-(set of 3) 432032 500
FEBSS4 4 Pole Spreader for FE-(set of 4) 432033 625
FEJP Phase Barrier set of 12 432085 950
FEDDF3 Plug in Unit 3P 432034 7000
FEDDF4 Plug in Unit 4P 432037 9000
FEWS3 Draw out system 3P 432168 13000
FEWS4 Draw out system 4P 432171 15500
FEQDB3MJ 3 160A 220/440V AC-Bottom Mounted 431136 10500
FEQDB3HJ 3 160A 400/690V AC-Bottom Mounted 431118FEQDB3MK 3 250A 220/440V AC-Bottom Mounted 431139 12000
FEQDB3HK 3 250A 400/690V AC-Bottom Mounted 431124 12000
FEQDB4MJ 4 160A 220/440V AC-Bottom Mounted 431159FEQDB4HJ 4 160A 400/690V AC-Bottom Mounted 431145
FEQDB4MK 4 250A 220/440V AC-Bottom Mounted 431161
FEQDB4HK 4 250A 400/690V AC-Bottom Mounted 431151
17300
E30
10500
1050010500
12000
12000
1000
1200
1200
Buy Log/Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
Record Plus Moulded Case Circuit Breakers
Record Plus
Accessories Common to FD / FE / FG
Aux. / Alarm
Contact
ShuntRelease
UV Release
Add on
Modules
SMR 2
SMR 2optional Modules
FAMECM External contact module (4 contacts, 1A/400V) 434013 10500
FAMAM2 Ammeter with 4 digit LCD display 436183 6000
FAMGAM2 Groundfault Alarm + Modbus communication 436185 9000
FAMGAS2 Groundfault Alarm + 2 channel load shedding device 436186 7000
FAMGAT2 Groundfault Alarm + fault type indicators 436187 7000
FAMGFM2 Groundfault Protection + modbus communication 436188 9000
FAMGFS2 Groundfault Protection + 2 channel load shedding device 436189 7000
FAMGFT2 Groundfault Protection + fault type indicators 436190 7000
FAMSM2 2 Channel load shedding device + Modbus communication 436192 9000
FAMST2 2 Channel load shedding device + fault type indicators 436197 7000
FAMMT2 Fault type indicators + Modbus communication 436191 9000
FAS10R Aux. switch right mounted 1NO 430837
FAS01R Aux. switch right mounted 1NC 430831
FAS10L Aux. switch left mounted 1NO 430834
FAS01L Aux. switch left mounted 1 NC 430828
FABAT10 Bell alarm trip unit (FD) / Bell alarm electronic trip unit (FE/FG) /Bell alarm RCD Device (FD/FE/FG) 1NO 430818
FABAT01 Bell alarm trip unit (FD) / Bell alarm electronic trip unit (FE/FG) /Bell alarm RCD Device (FD/FE/FG) 1NC 430815
FEBAT10 Bell alarm Thermal Magnetic trip unit (FE only) 1NO 430970
FEBAT01 Bell alarm Thermal Magnetic trip unit (FE only) 1NC 430969
FDBAM11 Bell alarm Mechanism - 1C / O contact (1NO + 1NC) - FD only (not for FDC & FDE) 430880
FABAM10 Bell alarm Mechanism (FE/FG) - 1NO 432003
FABAM01 Bell alarm Mechanism (FE/FG) - 1NC 432000
FASHTB Shunt Release 12V DC 430840
FASHTD Shunt Release 24V AC/DC 430843
FASHTF Shunt Release 48V AC/DC 430846
FASHTJ Shunt Release 110/130V AC/DC 430849
FASHTN Shunt Release 220/240V AC 250V DC 430852
FASHTU Shunt Release 400/480V AC 430855
FAUVRD Under Voltage Release 24V AC/DC 430861
FAUVRF Under Voltage Release 48V AC/DC 430864
FAUVRJ Under Voltage Release 110/130V AC/DC 430867
FAUVRN Under Voltage Release 220/240V AC 250V DC 430870
FAUVRU Under Voltage Release 440/480V AC 436472
450
1500
1980
Code
18500
Frame / BC Ref Cat Ref Rating
RCDModules
FGQDB3M FG RCD 3P 400/630A 220/440V 431184 19000
FGQDB3H FG RCD 3P 400/630A 400/690V 430856 19000
FGQDB4M FG RCD 4P 400/630A 220/440V 430869 23000FGQDB4H FG RCD 4P 400/630A 400/690V 430865 23000
ConnectionAccessories
FGBSS3 3 Pole Spreader for FG-(set of 3) 431981 1600
FGBSS4 4 Pole Spreader for FG-(set of 4) 431982 2000
FGJP Phase Separator (set of 12) 432852 1500
FGDDF3 Plug in Unit 3P 430944 15500
FGDDF4 Plug in Unit 4P 431064 19000
FGWS3 Draw out System 3P 432910 24000
FGWS4 Draw out System 4P 432913 27000
Code Reference*Two Letter Suffix
for Motor Operator
FG MCCB + ElectricalOperator
Description
Add 25000/-
MCCB + Motor Operator 24V AC/DC FG MCCB 6 Digit Code - -* MD
MCCB + Motor Operator 48V AC/DC FG MCCB 6 Digit Code - -* MF
MCCB + Motor Operator 60V AC/DC FG MCCB 6 Digit Code - -* MH
MCCB + Motor Operator 110V AC/DC FG MCCB 6 Digit Code - -* MJ
MCCB + Motor Operator 220/250V AC/DC FG MCCB 6 Digit Code - -* MN
MCCB + Motor Operator 400/440V AC FG MCCB 6 Digit Code - -* M8
E31
Buy Log/Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
Buy Log/Unit
Record Plus Moulded Case Circuit Breakers
Record Plus
DescriptionCat Ref PolesBreaking
Capacity IcuCode
FNEMFD Motor Mechanism 24V AC/DC 435683
FNEMFF Motor Mechanism 48V AC/DC 435680
FNEMFJ Motor Mechanism 110V AC/DC 435686FNEMFN Motor Mechanism 230V AC/DC 436324
FNNRD Ext. Rotary Handle 436519FNNRF Direct Rotary Handle 435739
FNPFM Aux. Disconnects 435758
FNBA11R Bell alarm contact right mounted CO 435761
FNS11R Aux. switch right mounted CO 436401
FNSHT8 Shunt Release 380/440V AC/DC 435692FNSHTD Shunt Release 24V AC/DC 435693
FNSHTF Shunt Release 48V AC/DC 435694
FNSHTJ Shunt Release 110/130V AC/DC 435695
FNSHTN Shunt Release 220/240V AC 250V DC 435696
FNUVD6 Delayed Under Voltage Release 230V AC 435697
FNUVR1 Under Voltage Release 24 V AC 435698
FNUVR6 Under Voltage Release 230 V AC 435699
FNUVR8 Under Voltage Release 400 V AC 435700
FNUVRD Under Voltage Release 24 V DC 435701
FNUVRF Under Voltage Release 48 V DC 435702
FNBSS3P Spreader for FK08 - FK12 3P 435708
FNBSS3R Spreader for FK16 3P 435710
FNBSS4P Spreader for FK08 - FK12 4P 435711
FNBSS4R Spreader for FK16 4P 435712
FNJP Phase Barrier FK 435722
Thermo Magnetic Release
Micro Processor Release SMR
Thermo Magnetic Release
Micro Processor Release SMR
For
de
tails
co
nta
ct n
ea
rest
sa
les
off
ice
FKN36NT630PF 3 50kA 630A 435444
FKN36NT800PF 3 50kA 800A 435336
FKN36NT100SF 3 50kA 1000A 435550FKN36NT125SF 3 50kA 1250A 435551
FKN36NE800PPF 3 50kA 800A 435393
FKN36NE100SQF 3 50kA 1000A 435396
FKN36NE125SSF 3 50kA 1250A 435384
FKN36NE160TTF 3 50kA 1600A 435387FKN46NE800PPF 4 50kA 800A 435447FKN46NE100SQF 4 50kA 1000A 435450
FKN46NE125SSF 4 50kA 1250A 435438
FKN46NE160TTF 4 50kA 1600A 435441
FKH36NT630PF 3 80kA 630A 435426
FKH36NT800PF 3 80kA 800A 435318
FKH36NT100SF 3 80kA 1000A 435553
FKH36NT125SF 3 80kA 1250A 435554
FKH36NE100SQF 3 80kA 800A 435288
FKH36NE125SSF 3 80kA 1000A 435276
FKH36NE160TTF 3 80kA 1250A 435279
FKH36NE800PPF 3 80kA 1600A 435285
FKH46NE800PPF 4 80kA 800A 435339
FKH46NE100SQF 4 80kA 1000A 435342
FKH46NE125SSF 4 80kA 1250A 435330
FKH46NE160TTF 4 80kA 1600A 435333
E32
Buy Log/Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
Record Plus Moulded Case Circuit Breakers
Circuit Breaker
Low Voltage Components - Buy Log Effective from 29.12.2008
Spectra range of Moulded Case Circuit Breakers
Thermal magnetic release (Adjustable Overload and Short Circuit)
Type BC 3Pole BC 3Pole
Spectra TME 18kA
Rating(A) Cat No. Buylog
16
20
32
40
50
63
80
100
125
STC34TME016F
STC34TME020F
STC34TME032F
STC34TME040F
STC34TME050F
STC34TME063F
STC34TME080F
STC34TME100F
STC34TME125F
3650
3650
3650
3650
3650
3650
3650
3650
4900
25kA
Rating(A) Cat No. Buylog
16
20
32
40
50
63
80
100
125
STE34TME016F
STE34TME020F
STE34TME032F
STE34TME040F
STE34TME050F
STE34TME063F
STE34TME080F
STE34TME100F
STE34TME125F
3900
3900
3900
3900
3900
3900
3900
3900
5200
Spectra TM
Thermal magnetic release (Adjustable Overload and Short Circuit)
Type BC 3Pole 4Pole
Roting(A) Cot No. Buylog Roting(A) Cot No. Buylog
16
20
32
40
50
63
80
100
125
160
200
16
20
32
40
50
63
80
100
125
160
200
16
20
32
40
50
63
80
100
125
160
200
16
20
32
40
50
63
80
100
125
160
200
STE34TM016F
STE34TM020F
STE34TM032F
STE34TM040F
STE34TM050F
STE34TM063F
STE34TM080F
STE34TM100F
STE34TM125F
STE34TM160F
STE34TM200F
STS34TM016F
STS34TM020F
STS34TM032F
STS34TM050F
STS34TM080F
STS34TM125F
STS34TM200F
STS34TM040F
STS34TM063F
STS34TM100F
STS34TM160F
STE44TM016F
STE44TM020F
STE44TM032F
STE44TM040F
STE44TM050F
STE44TM063F
STE44TM080F
STE44TM100F
STE44TM125F
STE44TM160F
STE44TM200F
STS44TM016F
STS44TM020F
STS44TM032F
STS44TM050F
STS44TM080F
STS44TM125F
STS44TM200F
STS44TM040F
STS44TM063F
STS44TM100F
STS44TM160F
4500
4500
4500
4500
5800
5800
5800
5800
5800
5800
5800
5800
5800
6700
8600
9800
8700
4500
4500
4500
4500
8000
6000
6000
6000
6000
7300
7000
7000
7000
7000
7000
7000
7000
7000
8000
10400
13000
12500
6000
6000
6000
6000
8800
25kA
36kA
Rating(A) Cat No. Buylog Rating(A) Cat No. Buylog
33E
Spectra TME Accessories
AccessoriesCode
STMESR1
STMETA
Shunt Release 110 - 415V 1400
Trip Alaram Contact 600
Auxiliary Contact 600
Rotary Handle (Door Mounted) 800
Phase Barriers (Set of 2) 95
Spreaders ( Set of 3) 300
Buy Log/ Unit
STMEAUX
STMEROHD
STMEPB1
STMESPRD1
Spectra TM Accessories
AccessoriesCode
STMSR1
STMETA
Shunt Release 110 - 415V 900
Trip Alaram Contact 800
Auxiliary Contact 800
Rotary Handle (Door Mounted) 950
Phase Barriers (Set of 2) 95
Spreaders ( Set of 3)
Spreaders ( Set of 4)350
480
Buy Log/ Unit
STMAUX
STMROHD
STMPB1
STMSPRD1
STMSPRD2
NEW
Circuit Breaker
Low Voltage Components - Buy Log Effective from 29.12.2008
E34
Microprocessor based release ( Adjustable Overload and Adjustable Short Circuit)
Type BC 3Pole 4Pole
36kA
Rating(A) Cat No. Buylog Rating(A) Cat No. Buylog
25
32
50
63
80
100
125
160
200
250
320
400
25
32
50
63
80
100
125
160
200
250
320
400
SES34ATO32F25
SES34ATO32F
SES34ATO63F50
SES34AT100F80
SES34AT160F125
SFS34AT250F200
SGS34AT400F320
SES34ATO63F
SES34AT100F
SES34AT160F
SFS34AT250F
SGS34AT400F
SES44ATO32F25
SES44ATO32F
SES44ATO63F50
SES44AT100F80
SES44AT160F125
SFS44AT250F200
SGS44AT400F320
SES44ATO63F
SES44AT100F
SES44AT160F
SFS44AT250F
SGS44AT400F
14200
14200
14200
15800
20900
22100
30000
30000
14200
14200
14200
16800
Spectra Plus
9900
9900
9900
11600
12800
16500
18500
9900
9900
9900
22100
22100
Spectra range of Moulded Case Circuit Breakers
50kA
500
630
25
32
50
63
80
100
125
160
200
250
320
400
500
630
500
630
25
32
50
63
80
100
125
160
200
250
320
400
500
630
SGS34AT630F500
SGS34AT630F
SEN34AT032F25
SEN34ATO63F50
SEN34AT100F80
SEN34AT160F125
SFN34AT250F200
SEN34AT032F
SEN34ATO63F
SEN34AT100F
SEN34AT160F
SFN34AT250F
SGN34AT630F
SGN34AT630F500
SGN34AT400F320
SGN34AT400F
SGS44AT630F500
SGS44AT630F
SEN44AT032F25
SEN44ATO63F50
SEN44AT100F80
SEN44AT160F125
SFN44AT250F200
SEN44ATO32F
SEN44ATO63F
SEN44AT100F
SEN44AT160F
SFN44AT250F
SGN44AT630F
SGN44AT630F500
SGN44AT400F320
SGN44AT400F
35500
15200
15200
15200
17900
19200
24900
25500
35500
15200
15200
15200
30500
30500
36000
36000
25600
11900
11900
11900
13100
14800
17500
19200
25600
11900
11900
11900
22500
22500
26000
26000
Spectra Plus Accessories
AccessoriesCode
SAAUX1
SAUV3
SAAUX2
SAUV4
Spectra Plus Auxiliary Contact ‘S’ type 1Changeover
Spectra Plus Undervoltage 24 AC/DC
1470
1925
Spectra Plus Auxiliary Contact ‘S’ type 2Changeover
Spectra Plus Undervoltage 48 AC/DC
1925
1925
Spectra Plus Shunt 110 AC/DC
Spectra Plus Bell Alarm Contact
1925
1925
Spectra Plus Shunt 220 AC/DC
Spectra Plus Undervoltage 220 AC/DC
Spectra Plus Extended Handle SE 160/SF250
3Pole Spreaders for SE 250 - 250A (Set of 3)
1925
1470
670
Spectra Plus Shunt 24 AC/DC
Spectra Plus Extended Handle SG400/600
4Pole Spreaders for SE 250 - 250A (Set of 4)
1925
1925
900
Spectra Plus Shunt 48 AC/DC
3Pole Spreaders for SE 160 - 160A (Set of 3)
3Pole Spreaders for SE 630 - 630A (Set of 3)
Spectra Plus Undervoltage 110 AC/DC
4Pole Spreaders for SE 160 - 160A (Set of 4)
4Pole Spreaders for SE 630 - 630A (Set of 4)
1925
470
1400
1925
1925
625
1800
Buy Log/ Unit
SAST1
SABAP1
SAST2
SAEFROH
SAFSPRD3P
SAST3
SAEGROH
SAFSPRD4P
SAST4
SAESPRD3P
SAGSPRD3P
SAUV1
SAUV2
SAESPRD4P
SAGSPRD4P
NEW
Circuit Breaker
BreakingCapacity Rating Type 3 Pole 4 Pole*
Icu (KA) (A) Code Reference Code Reference Buy Log/ UnitBuy Log/ Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
Moulded Case Circuit Breakers - 3 Pole and 4 Pole
TM/125/200 Front Adjustable Trip Unit 0.8 - 1.0)
25
25
25
25
25
25
25
25
25
25
25
36
36
36
36
36
36
36
36
36
36
36
16
20
32
40
50
63
80
100
125
160
200
16
20
32
40
50
63
80
100
125
160
200
TM125
TM125
TM125
TM125
TM125
TM125
TM125
TM125
TM125
TM 200
TM 200
TM125
TM125
TM125
TM125
TM125
TM125
TM125
TM125
TM125
TM 200
TM 200
SGC8405200
SGC8405210
SGC8405230
SGC8405240
SGC8405250
SGC8405263
SGC8405280
SGC8405300
SGC8405325
SGC8405260
SGC8405220
SGC8406010
SGC8406020
SGC8406030
SGC8406040
SGC8406050
SGC8406063
SGC8406070
SGC8406000
SGC8406025
SGC8406260
SGC8406220
4300
4300
4300
4300
4300
4300
4300
4300
5500
7700
8400
5600
5600
5600
5600
5600
5600
5600
5600
6400
8300
9500
SGC8407010
SGC8407020
SGC8407030
SGC8407040
SGC8407050
SGC8407060
SGC8407080
SGC8407100
SGC8407125
SGC8407160
SGC8407200
SGC8406110
SGC8406120
SGC8406130
SGC8406140
SGC8406150
SGC8406060
SGC8406080
SGC8406100
SGC8406125
SGC8406160
SGC8406200
5700
5700
5700
5700
5700
5700
5700
5700
6900
8300
12000
6700
6700
6700
6700
6700
6700
6700
6700
7600
9900
12500
TM-125/200 - Accessories
Shunt Release, 110 - 415 V AC
Trip alarm Contact - 1NO/1NC C/O
Auxiliary Contact
Rotary Handle (MCCB Mounted)
Rotary Handle (Door Mounted)
Phase Barriers (Set of 2)
Extension Terminals (Set of 3)
Extension Terminals (Set of 4)
Description Code Ref.
SGC8301064
SGC8301063
SGC8301062
SGC8301065
SGG9100045
SGC8301061
SGC8301067
SGC9202004
825
600
600
1400
800
95
350
480
Buy Log/ Unit
35E
Circuit Breaker
(With continuously adjustable Electronic release) O/L (lr): 0.5-1 In, S/C: 2-10 lr
LM Moulded Case Circuit Breaker - 3 Pole and 4 Pole
50 400 LM400B SGC8804320 32000 SGC8804005 43000n50 630 LM630B SGC8806210 37000 SGC8806005 4600050 800 LM800B SGC8808160 42000 SGC8808005 55000
LM Pro MCCBs - With Microprocessor Release(with O/L Short circuit, Instantaneous, Earth fault, Distinct fault indication & Trip history)
* 4 Pole MCCB’s - Neutral 100% rated
BreakingCapacity Rating Type 3 Pole 4 Pole*
Ics (KA) (A) Code Reference Code Reference
25 3.2 LM100C SGC8848050 7200 SGC8848041 1130025 6.3 LM100C SGC8854050 7200 SGC8854041 1130025 12.5 LM100C SGC8860050 7200 SGC8860041 1130025 25 LM100C SGC8866050 7200 SGC8866041 11300
25 50 LM100C SGC8872050 7200 SGC8872041 1130025 100 LM100C SGC8801050 7200n SGC8801041 11300n25 125 LM125C SGC8890050 8300n SGC8890041 1250025 160 LM160C SGC8896050 9900n SGC8896041 1400025 200 LM200C SGC8188070 11400n SGC8802041 16400n
35 3.2 LM100R SGC8848030 8200 SGC8848021 1150035 6.3 LM100R SGC8854030 8200 SGC8854021 1150035 12.5 LM100R SGC8860030 8200 SGC8860021 1150035 25 LM100R SGC8866030 8200 SGC8866021 1150035 50 LM100R SGC8872030 8200 SGC8872021 1150035 100 LM100R SGC8801030 8200 SGC8801021 1150035 125 LM125R SGC8890030 9500 SGC8890021 1380035 160 LM160R SGC8896030 10200 SGC8896021 1490035 200 LM200R SGC8188060 13800 SGC8802021 19400
50 3.2 LM100 SGC8848010 10500 SGC8848001 1280050 6.3 LM100 SGC8854010 10500n SGC8854001 1280050 12.5 LM100 SGC8860010 10500 SGC8860001 1280050 25 LM100 SGC8866010 10500n SGC8866001 1280050 50 LM100 SGC8872010 10500 SGC8872001 1280050 100 LM100 SGC8801010 10500n SGC8801001 12800n50 125 LM125 SGC8890010 11900 SGC8890001 1890050 200 LM200 SGC8188050 15900n SGC8802001 24900n50 250 LM250B SGC8188090 19200n SGC8888001 25500n
50 400 LM400B SGC8804310 22500 SGC8804001 30600n50 630 LM630B SGC8806200 26000 SGC8806001 35000n50 800 LM800B SGC8808150 29500 SGC8808001 42000
35 250 LM250R SGC8888090 17400 SGC8882001 21900
Buy Log/ UnitBuy Log/ Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
E36
Accessories for LM MCCB (3 Pole and 4 Pole) - Field Fittable
For use with
100A/125A/160A SGC8308027 160 SGC8308028 160
200A/250A SGC8308027 160 SGC8308028 160
400A/630A/800ASGC8308027 160 SGC8308028 160
* UV release with delay, 200 + msec available on request, contact our nearest Sales Office for delivery
Aux/Alarm Contact (1NO) Aux/Alarm Contact (1NC) UV Release Shunt Trip Release
Frame Code Ref. VoltageCode Ref. Code ref. Voltage Code Ref.(AC)
240V415V
240V
415V
240V
415V
SGC8302044 1050SGC8302053* 1150SGC8302043 1150SGC8302054* 1150SGC8308035 1050SGC8304016* 1150SGC8308034 1250SGC8304017* 1475
Factory fitted
110-415V AC110-220V DC
24-48V AC/DC
110-415V AC110-220V DC
24-48V AC/DC
SGC8301071
SGC8301072
SGC8308039
SGC8308040
800 n
1150 n
Factory Fitted Accessories for LM MCCB
Note: # The Electronic UV is not a no volt coil, contact our nearest sales office
for technical specifications.
External CBCT has tapping of 20%, 30% and 40% In
UV Electronic#240/415V AC
EF(Adj. Setting)
Frame3 Ph, 4 Wire
A3Ph, 3 Wire Systems
100/125/160A 850 6000
200/250A NA 7500
400/630/800A NA 8000
Circuit Breaker
110-415V AC110-220V DC
24-48V AC/DC
SGC8301071
SGC8301072
Accessories for LM MCCB (3 Pole and 4 Pole) - Field Fittable
Field Fittable Accessories
FrameRotary Controls EFM
(Adj. Setting)3 & 4 Pole
Code reference3 Phase, 3 Wiresystems only
DD160 SGC8301073 990 n 6000
DD250 SGC8302055 1080 7500
DD800 SGC8308041 1280 n 8000
1050
Buy Log/Unit
Buy Log/
Unit
Buy Log/
Unit
Buy Log/
Unit
Buy Log/
Unit
Buy Log/ UnitBuy Log/ Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
37E
tConforms to IEC 60947 Part II
tFull certification to ASTA / LOVAG / KEMA
tRatings 800 - 4,000A (5000 to 6300A on request)
tCompacted into 2 frame sizes (5000 to 6300A in frame 3)
tTrue RMS sensing, micro processor based protection releases
t50 / 65 / 80 kA performance
tBuilt-in safety features offered as standard
tField Fittable accessories
tRear or front access connections
tCommon dimensions for ease of installation
tMinimal clearance achieved reducing cubicle size
tUnique earth fault protection (unrestricted & restricted)
tCompatibility for simple upgrades
MPACT MPRO Air Circuit Breaker
Prices available on request
tNew generation ACBs with most modern design with “Static" or
“Microprocessor based" protection releases ensuring total discrimination
tConforms to IEC60947-2/IS13947-2. Type tested at CPRI for IS13947-2
tRange 800A to 4000A
tHigh breaking capacities from 55KA to 90KA
t3 pole and 4 pole versions, Withdrawble and fixed type, Manual or Motor
operation
tTropicalised to Class I (standard) and Class II (optional)
tStatic release LMZ - 7 with O/L, S/C, & E/F protection
tMicroprocessor based protection release - RMS 7, RMS 9D
(communication compatible
tFlexible terminal options
tHighest electrical & mechanical endurance
tMost user friendly for handling
Spectronic S Air Circuit Breaker
Circuit Breaker
N WE
Low Voltage Components - Buy Log Effective from 29.12.2008
E38
LMZ7tStandard Protection - Overload,
Short Circuit
Option (Factory Fitted)
tWith Distinct fault indicator
RMS 7tStandard Protection - Overload,
Short Circuit & InstantaneousOption (Site Fittable)tEarth Fault (EF) ProtectiontDistinct fault indicator (O/L, S/C & EF)tRating plug
RMS9tStandard Protection - Overload,
Short Circuit, Instantaneous &Earth Fault
tCommunication port
Options (Site Fittable)tRating plugtVoltage Conditioner (set of 3) - for
all voltage based parametersincluding power measurement
tZone selective interlocktModbus concentrator
Release Selection
1 Independent manual spring closingmechanism
1 Static release LMZ-7 with 4 Cts
or
1 Microprocessor (µP) release RMS 7with 3* CTs of standard ratings
1 Auxiliary Switches with 4NO + 4NCcontacts
4 Blocks of 6-Way sliding type LTdisconnectors
1 Rating Error prevention plug
1 Racking Handle
1 Set of Safety Shutters
Schedule ‘A’ lists prices of Air CircuitBreaker with the following accessories
Spectronic S ACB Withdrawable Version
Schedule ‘B’ lists prices of Air CircuitBreaker with the following accessories
1 Motor-Wound spring chargedclosing with motor
1 Closing Coil
1 Shunt Trip Release
1 Static release LMZ 7 with 4 CTs
or
1 Microprocessor (µP) release RMS 7with 3* CTs of standard ratings
1 Auxiliary Switch with 4 NO + 4 NCcontacts
4 Blocks of 6-Way sliding type LTdisconnectors
1 Rating Error prevention plug
1 Racking Handle
1 Set of Safety Shutter
* If RMS 7 is ordered with EF module the ACB is supplied with 4 CTS. 4 Pole ACB is suppled with 4 CTS. 4th CT for Neutral
Fixed version with rear horizontal terminals
Two basic frame sizes covering from 800 to 1600A in frame 1 & 2000 and 2500A inframe 2 (Height & Depth remains same through out the range
Breaking Capacities from 55 - 60KA
3-pole and 4-pole configuration
Field fittable accessories like under voltage and shunt trip release
Manually operated
Accurate protection with static / micro processor based protection releases (LMZ7/RM7)
Spectronic SP ACB Fixed Version (IMS)
tConforms to IS 13947-2-1993
tCassette mounted horizontal draw out type ACB fitted with fully interlocked cassettedoor automatic safety shutters, mechanical ON/OFF indicators
tCassette mounted ACB ensures validity of short circuit tests
tCassette finished to light grey, shade 631 of IS 5
tTwo types of static trip release (LMZ 2 & CTZM 71 with highly flexible overcurrent/short circuit and earth fault trip characteristics
t3 basic frame sizes for rating from 630A to 4000A
t4 pole version available upto 2500A
tService/Test/Isolated position with position indicators
tProvision for castell lock
tMore than three decades of proven performance across various industries
M - Pact Air Circuit Breaker
Circuit Breaker
IMS MWS
tWith Earth Fault Protection
Low Voltage Components - Buy Log Effective from 29.12.2008
39E
Schedule ‘A’ lists priceof Air Circuit Breakerswith the followingaccessories:
Schedule ‘B’ lists priceof Air Circuit Breakerswith the followingaccessories:
M-Pact Withdrawable Version
1 Independent manual spring closingmechanism
1 Static trip release RW2with over current/shortcircuit/EF protection complete with 4CTs of standard rating
1 Auxiliary switch with3 NO and 3 NC contacts
1 Operating handle
Schedule ‘B’ lists priceSchedule ‘A’ lists priceof Air Circuit Breakerswith the followingaccessories:
of Air Circuit Breakerswith the followingaccessories:
1 Independent manual spring closingmechanism
1 Static RW2 overcurrent/short circuit/EFrelease complete with 4CTs of standard rating
1 Auxiliary switch with6 NO and 6 NC contacts
4 Sets of 6-way plug &socket typeLT disconnector
1 Racking handle
1 Set of Safety shutters
Unepact Air Circuit Breaker
tCompact ACB designfor switchboard constructionfor shallow depth panel (500mm)(Height & Depth common throughout the range)
t2 basic frame sizesfor 800A to 2500A rating
t50KA Breaking Capacity
t3 pole and 4 pole versions
tManually operated
tUniform door cut-out
tFlexible static trip releasetype RW2
tProvision for castell lock
tFixed/Drawout version
Circuit Breaker
1 Motor-wound springcharged closingmechanism with motor
1 Spring release coil (closing coil)
1 Shunt trip release
1 Static trip release LMZ2 forover current/shortcircuit/EF release completewith 4 CTs of Standardrating
1 Auxiliary switch with4 NO and 4 NC contact
3 Sets of 6-ways slidingLT disconnector
1 Spring charging handle
1 Racking handle
1 Set of Safety shutters
1 Independent manualspring closingmechanism
1 Static trip release LMZ2 forover current/shortcircuit/EF releasecomplete with 4 CTS ofstandard rating
1 Auxiliary switch with4 NO and 4 NC contacts
3 Sets of 6-way slidingtype LT disconnector
1 Operating handle
1 Set of Safety shutters
Fixed Withdrawable
MWSIMS
Low Voltage Components - Buy Log Effective from 29.12.2008
E40
*
*Price on Request
Circuit Breaker
6. Local controls (ON/OFF Push Buttons) Interlocking is a standard offering with Spectronic ACB (Pad Lock not supplied)
5. For codes not available in the please contact our nearestBuy Log sales office
2. For other terminal options, please contact us.
3. 3 pole ACB requires ‘6’ nos of terminals and 4 poles ACB requires ‘8’ nos of terminals for incoming and outgoing
4. In case of combination of terminals, deduct the of horizontalBuy Log terminals and add the of selected terminal option forBuy Log incoming and outgoing separately
Note:
1. Rear horizontal terminals are standard
7. For 5000/6300A ACBs please contact us
800 89000 121000 92500 124500 100500 132500 104000 1360001000 95000 127000 98500 130500 106500 138500 110000 1420001250 118000 150000 121500 153500 129500 161500 133000 1650001600 130000 162000 133500 165500 141500 173500 145000 1770002000 158000 190000 161500 193500 169500 201500 173000 2050002500 185000 217000 188500 220500 196500 228500 200000 2320003200 244000 276000 247500 279500 255500 287500 259000 2910004000 315000 347000 318500 350500 326500 358500 330000 362000
Spectronics S Range 3Pole Draw-Out ACBs
Rating (Amps)
Static Release LMZ7 (O/L,S/C)
Static Release LMZ7(O/L,S/C,EF)
Microprocessor Release RMS7 (O/L,S/C)
Microprocessor Release RMS7 (O/L,S/C,E/F)
MWS ScheduleB
IMSSchedule A
MWS ScheduleB
IMS Schedule A
MWS ScheduleB
IMS Schedule A
MWS ScheduleB
IMS Schedule A
800 114500 156500 118000 160000 126000 168000 129500 1715001000 121800 163800 125300 167300 133000 175300 136800 1788001250 151200 193200 154700 196700 162700 204700 166200 2082001600 167000 209000 170500 212500 178500 220500 182000 2240002000 203200 245200 206700 248700 214700 258700 218200 2602002500 238400 270400 241900 273900 249900 281900 253400 2854003200 298200 330200 301700 333700 309700 341700 313200 3452004000 382900 422900 386400 418400 394400 426400 397900 429900
Rating (Amps)
Static Release LMZ7 (O/L,S/C)
Static Release LMZ7(O/L,S/C,EF)
Microprocessor Release RMS7 (O/L,S/C)
Microprocessor Release RMS7 (O/L,S/C,E/F)
MWS ScheduleB
IMSSchedule A
MWS ScheduleB
IMS Schedule A
MWS ScheduleB
IMS Schedule A
MWS ScheduleB
IMS Schedule A
Spectronics S Range 4Pole Draw-Out ACBs
Spectronics SP* Range Fixed ACBs (IMS)
800 50400 70300 53500 735001000 52500 75600 55600 787001250 74500 98700 77700 1018001600 76600 103900 79800 1071002000 90300 124900 93400 1281002500 103900 142800 107100 145950
Static Release LMZ7(O/L,S/C) Static Release LMZ7(O/L,S/C,E/F)Rating(Amps) 3Pole 4Pole 3Pole 4Pole
800/1000 770 9401000/1250 770 9401600 770 9402000 1760 21002500 2100 25303200 2750 44004000 3100 4950
Flexible Terminal Option Buy Log/ Unit of each Terminal
Rear Horizontal Rear Vertical
Rating(Amps)
RMS9D with current parameters and communication on requestRMS9D Release with current, voltage, power parameters and communication* on requestReduction for LMZ release 5500Shunt Release 2200Undervoltage Release 2600Castle Lock Kit (Single Letter-19mm) 1800Castle Lock Kit (Single Letter - 37mm dia) 1800Castle Lock Kit (Double Letter - 37mm dia) 3000Ronnis Lock for OFF interlock 1800Ronnis Lock for Withdrawn/ Connected position 1800Auxilliary Contact 1NO+1NC 7506Way LT Disconnects Block Fixed/ Moving 12003Way LT Disconnects Block Fixed/ Moving 600Microswitch for common fault indication 1000*For complete details, please refer to our catalogue
Release
Releases and accessories Description
Distinct fault indication for O/L,S/C in RMS7 release 4300Distinct fault indication for O/L,S/C,E/F in RMS7 release 4700Rating Plug for RMS7 without earth fault 2800Rating Plug for RMS7 with earth fault 5800Motor for MWS Mechanism(V)# 34000Closing Coil(V)# 6000IMS to MWS Conversion Kit** 42000**Motor,Closing Coil, Shunt Trip Release & MWS wiring harness)
Shunt Trip Release 110/220/415V AC 24/110V DCUndervoltage Release 220/415V ACClosing Coil 110/220 AC 24/110/220V DCMotor Mechanism 110/220 AC 110/220V DC
#Voltage Ratings
*SP range with micro processor based release on request
Buy Log/ Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
41E
Circuit Breaker
M-Pact ACBs with Static Release LMZ2
Air Circuit Breaker
# Voltage Rating
Shunt trip Release 110/250/415V AC 30/48/110/220V DC
Under Voltage Release 230/440V AC
Motor Mechanism 110/250V AC 110/250V DC
Closing Coil 110/250V AC 110/250V DC
For codes and of spares, please refer to our Spare Parts Buy Logs Buy LogList or contact our nearest sales office.
# Voltage Rating
Shunt trip Release 250/415V AC 24/110/220/250V DC
Under Voltage Release 220/415V AC
Release Selection
Reduction for LMZ2 releases 5500
Addition for CTZM71 releases 35600
Buy Log/Unit
Description
Accessories - M PactCode
ST Shunt trip (assembly with coil)# 4900
IUV 415 V AC instantaneous Under Voltage release 4900(assembly with coil)#
CC Spring Release Coil (Closing Coil)# 5300
LTM LT Disconnects - Moving 1500
LTF LT Disconnects - Fixed 1500
INT Mechanical interlock with key (Castell Lock) 2500
MS Micro switch for auto trip indication 1800
EF-1 Earthfault indication 1400
LOD Lock-out device for pera with Micro Switch 2500(Common Fault Indicator set)
Buy Log/Unit
3 - Pole
FrameSize
4 - Pole
Rating(Amps) IMS
ScheduleMWS
ScheduleA B
IMSSchedule
MWSSchedule
A B
M610
M16
M20M25
M3032
M40
800 129500 176400 152000 208000
1000 138100 183200 171800 227800
1250 168700 213800 214800 2708001600 181500 226600 242600 298600
2000 223900 261300 279600 3298002500 259300 289900 325400 375600
3200 337200 367800 - -4000 398800 429400 - -
Buy Log/ Unit Buy Log/ Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
E42
Residential Products
Miniature Circuit Breaker
Safe - trip MCBRef. Standards - IS 8828 / IEC 8980.5-63A in SP, DP, TP, FP pole configuration10kA breaking capacity for entire rangeCurrent Limiting - Class 3Tripping Curves: B,C, & D for application specific selectionWide range of Field Fittable accessories - Auxiliary Contacts,Shunt Trip U/V coil, Padlock
Residual Current Circuit BreakerSafe - trip RCCB & RCBORCCB
6 - 63A, 2 pole & 4 pole, 240V/415V AC Sensitivity.. 30mA, 100mA, 300mACan be used as Main Switch / Isolator
RCBO - RCCB with Overload Protection6 - 63A in 2 pole and 4 pole Sensitivity.. 30mA, 300mA C CurveBreaking Capacity - 10kA Approved
MCB Distribution BoardsWide range designed to suit every application & ambience.Liberal wiring space
Safeline Range Sheet Steel DBSSPN & TPN DB in 4,8,12 way in Single door & Double door configuration
Plug & Socket Distribution Boards20 A SPN Plug & Socket DB30 A SPN Plug & Socket DB
Phase Segregated Compartmentalized DbsSingle door & Double door. 4,6,8 & 12 ways
Time SwitchesAuto switching device operating on real timeWide range of switches for Day. Week, Day+Week, Year programSynchronous, Quartz & Digital type with min switching time of 1sec.Profile matching with MCBs, DIN channel mounting, can be fitted in any DBEasily programmable
Comfort FunctionsWide range of DIN channel mounting productsProfile matching with MCBs, can be fitted in any DB• Modular switches 1632A • Push-buttons 16A • Mains disconnect switch32-100A • Modular switches 63-80-100A • Day-night contactors • Modularcontactors • Impulse switches • Modular relays • Light sensitivity switch• Staircase lighting time switch • Time relays • Bell transformers • Socket-outletsMeasurement device - Analogue and digital • Net analyser • Hour countersSurge arresters • Thermostats • Tariff time switches
Type AC - General ApplicationType A - For Harmonic Rich Environment
Low Voltage Components - Buy Log Effective from 29.12.2008
43E
Ordering Code
while ordering please specifythe code as below.PGE83_ _ _ _ _
1-C Curve, 5-B Curve
No. of Poles(1 - SP, 2 - DP, 3 - TP, 4 - FP)
Current Rating(0.5-5, 1 - 1, 2 - 2...63 - 63)
Example: 4P, 25A, C Curve Code: PGE83144025
Miniature Circuit Breakers - Series G 2000
MCBs
Configuration Rating ‘B’ Curve ‘C’ Curve
0.5A-4A - 245
SP 6A-32A 165¾175¾
40A 340 35050A,63A 350 3650.5A - 4A - 670
DP 6A - 32A 485¾500¾40A 780 800
50A, 63A 795 8200.5A - 4A - 1045
TP 6A - 32A 770 815
40A 1160 123050A, 63A 1200 12500.5A - 4A - 1310
FP 6A - 32A 1040 1070
40A 1520 157550A, 63A 1560 1595
Residential Products
IsolatorsConfiguration Rating
32A 18040A 22563A 24032A 280
40A 29563A 37532A 46040A 51063A 590
32A 520
40A 650
63A 71080A 760
100A 860
FP
TP
DP
SP
Code Reference
PGE8521032PGE8521040PGE8521063PGE8522032PGE8522040PGE8522063PGE8523032PGE8523040PGE8523063PGE8524032PGE8524040PGE8524063666569666561
Accessories
Auxiliary Switch (1c/o) 525
Shunt trip, 110 - 415V AC/110 - 125V DC 1425
Shunt trip, 24-60 V AC/ 24-48V DC 1425Undervoltage, 240V AC 1375Pad lock bracket 175
672567
PGV8537002
PGV8537003PGV8537007PGV8537004
Residual Current Circuit Breaker - RCCB (AC Series)Rating
PolesVolt. Amps
Sensitivity(mA)
CodeReference
240V/415V
AC
240VAC
25 4 3040 4 30
63 4 30
25 4 100
40 4 10063 4 100
25 4 300
40 4 30063 4 300
25 2 30
40 2 30
63 2 30
25 2 10040 2 100
63 2 100
25 2 300
40 2 300
63 2 300
23402360 n
2780 n
2440
2500 n
2890 n
2440 n
2500 n
2890 n
1785 n
2105 n
2420 n
1860 n
2190 n
2520
1860
2190
2520
606208606209
606210
606216
606217606218
606224
606225606226
607125
607126
606134
606140606141
606142
607127
607128
606150
NEW
Type A Suitable for harmonic rich environment available
against request
Buy Log/ Unit
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
F44
Residential Products
Residual Current Circuit Breakerwith Over Load & Short Circuit
RatingPoles
Volt. AmpsSensitivity
(mA)
240VAC
6 2 30 609962 202010 2 30 609963 2020
16 2 30 609965 2020
20 2 30 609966 2020
25 2 30 609967 2020
32 2 30 609968 2220
40 2 30 609969 2590
6 2 300 609980 247510 2 300 609981 2475
16 2 300 609983 2475
20 2 300 609984 2475
25 2 300 609985 247532 2 300 609986 2475
40 2 300 609987 2765
Protection - RCBO (RCD+MCB)
CodeReference
Description
32A 30mA 2P 2 Mod 155032A 100mA 2P 2 Mod 159032A 300mA 2P 2Mod 1590
63A 30mA 2P 2Mod 1890
63A 100mA 2P 2Mod 1960
63A 300mA 2P 2Mod 1960
32A 30mA 4P 2Mod 1755
32A 100mA 4P 2Mod 192032A 300mA 4P 2Mod 192063A 30mA 4P 4Mod 1945
63A 100mA 4P 4Mod 2105
63A 300mA 4P 4Mod 2105
607536607537607538
607542
607543
607544
607722
607723607724607734
607735
607736
Addon RCDs
* 2P/4P MCB and 2P/4P Addon RCD to be coupledtogether for a 2P/4P RCBO
CodeReference
Sheet Steel (Safe Line - Single Door)
Configuration
SPN 4 Way 650SPN 8 Way 780SPN 12 Way 920TPN 4 Way 1400TPN 8 Way 2000TPN 12 Way 3000
Sheet Steel (Safe Line - Double Door)
Configuration
SPN 4 WaySPN 8 WaySPN 12 WayTPN 4 WayTPN 8 WayTPN 12 Way
85010001200185025503400
Distribution Boards
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
Buy Log/Unit
F45
Surgeguard - Surge Arresters
Code
ReferenceDescription Imax
Up
(L-PE)Un
CLASS 2 - Single Pole Plug-in- Plug & Base
666545 SP Plug in type surge arrester, 20S2 20kA 960V 230V 2600666546 SP Plug in type surge arrester, 20S4 20kA 150V 400V 2800
666547 SP Plug in type surge arrester, 45S2 45kA 1000V 230V 3300
666548 SP Plug in type surge arrester, 45S4 45kA 2100V 400V 3200
666549 SP Plug in type surge arrester, 65S2 65kA 1200V 230V 6300
666551 SP Plug in type surge arrester, 65S4 65kA 1950V 400V 4400
666537 SP Plug in type surge arrester, with 1C/O, 45C2 45kA 1000V 230V 3800
666539 SP Plug in type surge arrester, with 1C/O, 45C4 45kA 2100V 400V 3800
666542 SP Plug in type surge arrester, with 1C/O, 65C2 65kA 1200V 230V 5400
666544 SP Plug in type surge arrester, with 1C/O, 65C4 65kA 1950V 400V 5700
CLASS 2 - Multi Pole monoblock
666525 DP (1+N) monoblock Surge arrester, 20S2 20kA 960V 230V 4000
666526 FP (3+N) monoblock Surge arrester, 20S4 20kA 960V 400V 4900
666527 DP (1+N) monoblock Surge arrester, 45S2 45kA 1000V 230V 5100
666529 FP (3+N) monoblock Surge arrester, 45S4 45kA 1000V 400V 7900
666530 FP (3+N) monoblock Surge arrester, with 1C/O, 45C4 45kA 1000V 400V 9900
666533 FP (3+N) monoblock Surge arrester, with 1C/O, 80C4 80kA 1200V 400V 15000
CLASS 2 - Replacement module (Cartridge only)
666534 Cartridge for 666545 20kA 960V 230V 1800
666535 Cartridge for 666546 20kA 150V 230V 2000
666536 Cartridge for 666547 45kA 1000V 230V 2200
666538 Cartridge for 666548 & 666539 45kA 2100V 400V 2200
666541 Cartridge for 666542 & 666549 65kA 1200V 230V 3500
666543 Cartridge for 666544 & 666551 65kA 1950V 400V 3500
666524 Sine Wave Tracker - - 5700
666532 Decoupling coil 40A - - 4800
Residential Products
Phase Segregated Sheet Steel DBs.(Single Door)¤
Configuration
4 Way 46006 Way 54008 Way 580012 Way 6800
Phase Segregated Sheet Steel DBs.(Double Door)¤
Configuration
4 Way 56006 Way 62008 Way 700012 Way 8600
P & S SPN 20A 800
P & S SPN 32A 900
Plug & Socket DB
Configuration
Note:# The DB’s Buy Logs are inclusive of Neutral & Earth Bar¤ The DB are inclusive of Phase & Neutral busbar & Earth barBuy Log
Time Switches
Description Model Code Reference
Electro - Mechanical - ClassicDay program W/o reserve 30min Talento 111 666112 2100
Day program with reserve 15min 72*72 CLS72Q41D 666178 2150Day program with reserve 30min Talento 211 666104 2450
Week program with reserve 3 hrs Talento 271 666109 2450
1 Day. 1Week program with reserve 30min/3hrs Talento 202 666108 4150
2 Day program with reserve 30min/30min Talento 212 666103 3600
Digital - GalaxDay / Week program with reserve 30min Talento 371 686532 4350Day / Week program with reserve 30min Talento 371mini 686530 7100Day / Week program with reserve (2c/o) Talento 372 686533 8200
P & S TPN 20A 1500
P & S TPN 32A 1650
Buy Log/ Unit Buy Log/ Unit
Buy Log/ Unit
Buy Log/ Unit
Buy Log/ Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
F46
Busways
Overhead Busbars (OHBB)Type RR overhead busbar units offer highly flexible power distribution system to meet complex shop layouts
200A to 400A OHBB, standard units of 3658mm and 2440mm long respectively
Busbars are supported by fire retardant phenolic moulds
Complete safety with fully shrouded plug in points at specific intervals
Extended range of 200A to 800A in Copper & 630A to 800A inAluminuim OHBB also available on request
Overhead Busbars and Plug In Box
Plug in BoxFor direct plugging into OHBB
32A, 63A and 100A TPN plug in Boxes with HBC Fuselinks forflexibility in power distribution (with MCCB/provision for MCB, on request)
Contacts reinforced by spring steel strips for proper contact with busbars
Two earth pins located at the ends engage first in the special earthbushes before the main contacts make
Tap Off BoxAvailable in 63A to 630A with SDFUs/MCCBs. Contact our nearest sales office for detailed information
Incomer Housing with MCCBAvailable in 400A and 630A as standard design. Contact our nearest sales office for detailed information
TM
WavePro Series Busway
(OHBBs & Rising Mains)
N WE
Busways
Highly flexible solution for complex power distribution requirements of medium tolarge size commercial buildings and industries.
Compact design, sandwich construction. KEMA certified, conforms to IEC standards
Housing made up of Aluminium Alloy. Available in plug-in & feeder versions
Range: 100A - 5000A, 3P4W, 3P5W, IP40 - IP65 configurations. Short Circuit ratingsfrom 36 KA - 100KA (for various ratings)
Standard Length of the Busway is 3mts. Non standard sections on request
Standard Length plug-in Busway can be provided with upto 8 plugs per length(8 plugs standard offering)
Busway Plugs
Available with MCCBs - with rotary handle or crank handle(metal handle on the sides)
Both the versions offer interlock, preventing the opening of the door when thedevice is "ON", preventing pulling out of the plug when the device is "ON"
Three basic frame sizes, 125A (16 - 125A), 250A (160 - 250A), 630A (320 - 630A)
Busway Fittings
Complete range of accessories to suit site conditions
Elbows (Right, Left, Up, Down), Tees, Cable Tap Boxes (End, Center), Expansion Lengths,End Boxes Etc.
Low Voltage Components - Buy Log Effective from 29.12.2008
F47
Overhead Busbar
Rating Material200A Aluminium400A Aluminium630A Aluminium800A Aluminium200A Copper400A Copper630A Copper800A Copper
For detailsplease contact
our nearestsales office
32 TIA TSATPN RRF303N-4 PGT8215000 2300
63 TIA, TIS TSA, TSSTPN RRF603N-4 PGT8220000 2700
100 TCP TSDTPN RRF1003N-4 PGT8225000 5800
Associated HBC Fuselinks
Bolted
T TS(excludingFuselinks)
CodeReference
List No.Con-
figurationRating
Plug-in Box
Volt Amp
415 VAC
Note: Plug-in boxes with MCCBs available on request
Plug-in boxes with provision for MCBs available on requestTap Off Boxes with SDFUs, MCCBs, End Fead Units / Incomer Housings available on request
Busways & Accessories
Blank end Covers
CodeRating Reference200A GGT0100007
400A GGT0100008
Overhead Busbar / Rising Mains
TM
WavePro Series Busway
N WE
Description100 - 5000A Cu Busbar System (Plug in & Feeder configurationsPlug in Boxes with MCCBAccessories: Elbows, Tees, Offsets, End Tap Boxes, Center Tap Boxes etc.
Buy Log/ UnitBuy Log/ Unit
Buy Log/Unit
Buy Log/ Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
For details please contact our nearest sales office
For details please contact our nearest
sales office
G48
Capacitors
Three types - MPP, APP and Mixed Dielectric Explosion proof safe design
Long Life Low Watt loss
Type MPP (Metallized Poly Propylene) - 3ø, 50Hz
Note: Capacitor in other Voltages, KVAr & frequency available on request
MPP 415 V MPP 440 VCode Reference Code Reference
1 MPP011 370 MPP012 3302 MPP021 640 MPP022 5903 MPP031 950 MPP032 9504 MPP041 1260 MPP042 12405 MPP051 1570 MPP052 15406 MPP061 1850 MPP062 1780
7.5 MPP071 2240 MPP072 21408 MPP081 2380 MPP082 2280
10 MPP101 2820 MPP102 272012.5 MPP121 3510 MPP122 337015 MPP151 4220 MPP152 405020 MPP201 5630 MPP202 539025 MPP251 7040 MPP252 6740
Banking includes - Busbars/links with heat shrink colour coded sleeves, base mounting
frame. Terminal chamber cover, Earthing terminal and cable entry undrilled gland plate.
Banking
AI 40 per KVAr
Cu 50 per KVAr
LV Capacitors
KVAR
415 V 440 VCode Reference Code Reference
5 MPPH051 1980 MPPH052 19207.5 MPPH071 3550 MPPH072 344010 MPPH101 3720 MPPH102 3615
12.5 MPPH121 4410 MPPH122 430015 MPPH151 5300 MPPH152 514020 MPPH201 7080 MPPH202 685025 MPPH251 8860 MPPH252 8740
KVAR
Type MPP - Heavy Duty (Metallized Poly Propylene) - 3ø, 50Hz
415 V 440 VCode Reference Code Reference
5 MPPC051 1420 MPPC052 13507.5 MPPC071 2020 MPPC072 195010 MPPC101 2510 MPPC102 2510
12.5 MPPC121 3310 MPPC122 317015 MPPC151 3800 MPPC152 368020 MPPC201 5070 MPPC202 490025 MPPC251 6280 MPPC252 6130
KVAR
Type GeCap - Cylindrical (Metallized Poly Propylene) - 3ø, 50Hz
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
G49
LV Capacitors
MXD 415V MXD 440VCode Reference Code Reference
7.5 MXD071 5570 MXD072 53808 MXD081 5930 MXD082 5720
10 MXD101 7100 MXD102 704012.5 MXD121 9030 MXD122 884015 MXD151 10840 MXD152 1052020 MXD201 14440 MXD202 1406025 MXD251 18060 MXD252 17560
KVAR
Type MD (Mixed Dielectric) - 3ø, 50Hz
Type APP (Film Foil) - 3ø, 50Hz
APP 415 V APP 440 VCode Reference Code Reference
5 APP051 2970 APP052 28507.5 APP071 4470 APP072 42208 APP081 4750 APP082 4550
10 APP101 5740 APP102 550012.5 APP121 7190 APP122 686015 APP151 8550 APP152 825020 APP201 11380 APP202 1122025 APP251 14270 APP252 1374030 APP301 17100 APP302 16700
KVAR
Model No. of Stages Code Reference
PC06 6 PC0610 14830PC08 8 PC0810 18030PA12 12 PA1210 23800PA14 14 PA1410 26470
Ge-Povar APFC Relay
Buy Log/ Unit
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Buy Log/Unit
Low Voltage Components - Buy Log Effective from 29.12.2008
H50
Top Related