The AGM start-stop battery in which new lead-carbon technology and
advanced lead alloy formula adopted is suitable for the vehicle with
start/stop system, it has excellent charge acceptance and cold starting
performance, especially the PSoC and high-low temperature cycle life are
outstanding compared to the similar products on the market.
Technical Parameters
LN2
Nominal Voltage
Capacity
Reserve Capacity
Weight
Dimesions
CCA(-18°C)
Self Discharge @ 25°C (77°F)
Operating Temperature Range
Acceptable Charging Current
Charging Voltage @ 25°C (77°F)
Case Materials
Terminal
-30°C~70°C(-22°F~158°F)
0~120 A
13.5~14.8 V/cell
High temperature resistant materials
Tapered terminal(Left:negative;Right:positive)
AGM Start-Stop Battery
AdvantagesAdvanced Grid Production Technology: The battery has excellent anti-corrosion performance because of new alloy formula and advanced cold rolled grid technology; Also, very little water loss signi�cantly extend the service life of the battery in high temperature environment.AGM Technology: Oxygen released from positive pole can react with negative lead and gas emissions are controlled by special valve construction, which prevent vehicle components installed near the battery from being corroded; At the same time, due to AGM technology the battery has no free liquid electrolyte, even if the battery is cracked in the sudden accident such as intense turbulence or high speed collision it can still normally start vehicles.High Assembly Pressure Design: High assembly pressure design can slow the positive paste shedding and prolong its life time greatly.Lead Carbon Technology: With the most advanced composite carbon material, the battery’s chargeacceptance is signi�cantly improved, therefore,it can more quickly capture the feedback current from vehicle.Long Cycle Life: The starting life is more than100000 times, 2 times longer than ordinary battery.
EN 50342
VDA
GB/T5008.1-2013
12 V
60 Ah @ 20hr to 10.5 V @ 25°C (77°F)
110 min @ 25°C(77°F)
18.5 kg(40.8 Ibs)
242×175×190 mm
680 A to 6.0 V @ -18°C(EN)
<8% after 90 days storage
Compliant Standards
GFM SeriesVRLA Battery
Performance Curves
AGM Start-Stop BatteryLN2
Dimensions
175mm242mm
190m
m
V2.0
201
7031
0EN
Curve of Self-discharge at Di�erent Temperature
20
40
60
80
100
0 3 6 9 12 15 18 21 24Storage Time (months)
10℃
20℃
30℃40℃
Capa
city
(%)
6
7
8
9
10
11
12
13
0 500 1000 1500 2000 2500 3000 3500 4000
Cycle Number
Cycle Life at 25°C and 17.5% Depth of Discharge
0
2
4
6
8
10
12
14
0 100 200 300 400 500 600Cycle Number
Volta
ge(V
)Vo
ltage
(V)
Cycle Life at 40°C and 50% Depth of Discharge
Cycle Number
0
2
4
6
8
10
12
14
0 20000 40000 60000 80000 100000 120000
Idling- Stop L ife at 25°C
Volta
ge(V
)
Top Related