Download - LED 400W ARC-COB TM to 90% over Incandescent, · Arc-Cob Lamp features Excellent Optics for Increased Visibility, and Low Power Consumption, saving up to 90% on Electricity Costs.

Transcript
Page 1: LED 400W ARC-COB TM to 90% over Incandescent, · Arc-Cob Lamp features Excellent Optics for Increased Visibility, and Low Power Consumption, saving up to 90% on Electricity Costs.

Designed for Easy Installation in New and Existing Fixtures, the HyLite LED Arc-Cob Lamp features Excellent Optics for Increased Visibility, and Low Power Consumption, saving up to 90% on Electricity Costs. With a Lamp Life of up to 60,000 hours, the HyLite LED Arc-Cob Lamps Significantly Reduce Relamping costs, thus decreasing Maintenance and Disposal Costs.

The HyLite LED Arc-Cob Lamp enhances vision for better Optical Acuity, and reduces Light Pollution (No Wasted Light). Suitable for Fully Enclosed Fixtures, its Compact Size makes it the ideal Replacement for CFL, MV, HID, and HPS Lamps in Various Applications.

• FullyEncapsulated:Shatterproof,High-Shock&High-VibrationResistant

•InstantStartandRestart:NoWarm-upTimerequired

• Quick&EasyInstallation:NoBallastnecessary.DirectRetrofitinto existingsocketbysimplybypassingtheBallast.

• ExtremelyEfficient:HighLumenEfficacy:113LpWwithHighCRI>80

•350°RotatableBaseforDirectionalLighting

• Heat&ImpactResistant,UVProtected,Non-yellowing,OpticalGradeLens

• SafeandReliable:IsolatedCircuitDesign.NoNoiseorRFInterference

• GoodHeatDissipationwithProprietary-designedHeatSink

• UniversalVoltage:100-277V,AC

• Integral1kVSurgeSuppressor&Protection.IncludesaFree20kAin-line Surge Protection Device for added Protection

• NoUVRadiation–DoesNotAttractInsects

• WideAmbientOperatingTemperature:-40°Fto+131°F[-40°Cto+55°C]

•IdealforusewithRenewableEnergyResources–Solar&WindPower

•Safe:ContainNoHazardousMaterials;RoHSCompliant:NoLead, Mercury,ToxicMetalsorArsenicGases.NoDisposalRequirements.

•EnvironmentallyFriendly:98%oftheHyLiteLEDLampisRecyclable

Page:1of3

Incandescent HPS/HID CFL HyLite

800W 400W 300W 100W

88% 75% 67% Energy Savings (%)*

* Does not include Ballast Loss, Maintenance and Replacement Lamp Savings and Disposal Costs which can amount to additional Savings of 30~50%!

Replacewith

Lamp can be oriented in any position - does not affect or diminish the life of the Lamp

Universal Burning Positioning

HyLiteLEDHighPerformanceArc-CobLamps-Upto60,000hour*RatedPerformance Life. OutstandingQualityofLightwithEnergySavingsofupto 90% over Incandescent, 75%overHPS/MHLampsand67%overCFL.ARC-COB TM

LED

5” (127mm)

2.5”

(65m

m)

4.3”

(110

mm

)

11” (277mm)

400WMH / HPSEquivalent

*Depending upon the ambient temperature of the installation location

HighPerformanceLEDArc-CobLamp,100W FREE!20 kA

In-line Surge Protection Device Included.

Additional Protection for your HyLite Arc-Cob Lamp

at no Cost!

LED Product Partner

Reliable andLong-Lasting

Warranty

5years

Vibration andShock Resistant

Solid State

Radiation-FreeNo Humming

IRUV

No IR/UV

No Noise

113 LpWLM-79 Tested

High Efficacy

LM-80 TestedISTMT Tested

Reliability

Reduction ofup to 88%

Energy Costs

Up to 60,000 Hours

Low Voltage

Longer Life&

Beam Angle

Wide &Uniform

120°

For Enclosed Luminaires

Suitable

Zero Interference

No EMi / RFi

Suitable for

Damp Locations Enclosed Fixtures

Page 2: LED 400W ARC-COB TM to 90% over Incandescent, · Arc-Cob Lamp features Excellent Optics for Increased Visibility, and Low Power Consumption, saving up to 90% on Electricity Costs.

Page:2of3

C0/180, 71.9°, 76.6°

C90/270, 21.7°, 47.9°

Unit: cd030

60

90

120

150-/+180

-150

-120

-90

-60

-30

0

700

1400

2100

2800

3500

High Performance LED Arc-Cob Lamp, 100W

Photometrics - Type III

Intensity: (Unit, cd)

Average Beam Angle (50%): 109.1°

Flux Out: 3160 lm

2 m6.5 ft.

Height

4 m13.1 ft.

6 m19.7 ft.

8 m26.3 ft.

10 m32.8 ft

Angle: 69.63° DiameterEAvg, Emax

278 cm9.1 ft.

556 cm18.3 ft.

835 cm27.4 ft.

1113 cm37 ft.

1391 cm45.6 ft.

512.9/743.7 lx47.65/69.1fc

128.2/185.9 lx11.91/17.27 fc

56.99/82.63 lx5.29/7.68 fc

32.06/46.48 lx2.98/4.32 fc

20.52/29.75 lx1.91/2.76 fc

ARC-COB TM

LED

C0/180, 55.7°, 56.2°

C90/270, 55.8°, 53.5°

Unit: cd0

30

60

90

120

150-/+180

-150

-120

-90

-60

-30

0

900

1800

2700

3600

4500

High Performance LED Arc-Cob Lamp, 100W

Photometrics - Type V

Intensity: (Unit, cd)

Average Beam Angle (50%): 110.6°

Flux Out: 8478 lm

2 m6.5 ft.

Height

4 m13.1 ft.

6 m19.7 ft.

8 m26.3 ft.

10 m32.8 ft

Angle: 109.29° DiameterEAvg, Emax

564 cm18.5 ft.

1128 cm37 ft.

1691 cm55.5 ft.

2255 cm74 ft.

2819 cm92.5 ft.

330.8/1033 lx30.73/95.93 fc

82.70/258.1 lx7.68/23.98 fc

36.76/114.7 lx3.41/10.66 fc

20.67/64.53 lx1.92/5.99 fc

13.23/41.30 lx1.23/3.84 fc

Model Delivered Suggested InputLine Base Dimensions&Weight(each) No. Watts Lumens Install Height Current Type Diameter Height Weight

HL-AC-100W-T3-E39 100 9,453<32ft.(10m) 361mA~1.0A E39/E40(Mogul) 4.3”(110mm) 11”(77mm) 2.2lb.(1kg)

HL-AC-100W-T5-E39 100 11,268

As part of the company’s continuous product improvement program, HyLite reserves the right to change materialsor modify the design of its product without notification. All Specifications subject to change without notice. All values are design and/or typical values when measured under laboratory conditions. Actual Values depend upon the ambient temperature of the installation location. Please consult factory for your specific requirements.

• MinimumLampCompartmentDimensionsforEnclosedFixtures:9.25”x9.25”x17.5”(235mmx235mmx440mm)

• ToPreventearlyLampFailure,LampshouldonlybeinstalledinOperatingEnvironmentsrangingfromaMinimumof-40°C(-40°F)toaMaximumof+55°C(131°F)

• Efficacy:113LpW • CRI:>80 • BeamAngle:110º~120º • Max.THD(%):<20% • UniversalInputVoltage

• PowerFactor:>0.9 • Protection:IP44 • RatedLife:50~60,000Hrs. • Warranty:5Years 100~277V,AC50/60Hz.

• 347V,480VAvailable with with External Step-Down Transformer only. Please see HL-DT-125VA-480-277VSpec.Sheetat:https://hyliteledlighting.com/resources/specification-sheets/

• CCT:5000°K~5500°Kforgreatervisibility.Productswith2400°K-6500°K(CCT)areavailableas“SpecialOrders” only and with Longer Lead Times

*Depending upon the ambient temperature of the installation location

Page 3: LED 400W ARC-COB TM to 90% over Incandescent, · Arc-Cob Lamp features Excellent Optics for Increased Visibility, and Low Power Consumption, saving up to 90% on Electricity Costs.

Ideal for high-quality illumination in:

• WallPacks • FloodLights

• StreetLighting • ParkingLotLighting

• CanopyLights • WalkwayLighting

• SecurityLights • TunnelLighting

• PedestrianTunnels • Freezer&ColdStorageLights

• DrivewayLighting • ParkingGarageLights

Thermax tm -ProprietaryThermalManagementSystem:HyLite100WArc-Cobsusebothactiveandpassivecoolingmakingitan excellent retrofit. Active cooling uses no bearings, brushes, or other frictional parts to rub or wear out and has extremely low acoustical emissions. Longer LED life is assured by Thermax tm our Proprietary Thermal Management System that controls currentlevelstotheLEDsbasedontemperature.At149°F(65°C)theArc-CobbeginstocutbackonthecurrenttotheLEDstoeithermaintain,orreducethetemperaturebackdownto149°F(65°C),assuringcooleroperationandlongerlife.

Page:3of3

4” (100mm)

4.3” (110mm

)

5” (127mm)

2.5” (65mm

)4.3”

(110

mm

)

11” (277mm)

4” (1

00m

m) 2.85” (72m

m)

ARC-COB TM

LED

Warning - Risk of Fire or Electric Shock

• Disable all Power to the Lamp before Inspection, Installation, or Removal. Failure to do so will create a Hazardous and Fatal Working Environment.

• SuitableforuseinDry,DampandWetLocations.LampmustbeinstalledinaccordancewithNational,State,and/orLocalElectricalCodes. DoNotOpen–NoUserServiceablePartsInside.

• OperateinFixturesthatprovidetheFreeFlowofAiraroundtheLampHeatSink.InEnclosedFixtures,ensuretheLamphasenoughSpaceforHeatDissipation. This will ensure Lumen Maintenance and extend its Working Life. When products are used in Outdoor Fixtures, ensure the space is Waterproof and Well Ventilated.

• NotforuseonaDimmerorRemoteControls.ThisLamp must be controlled only by either a Switch or an Electronic Photosensor. Do not use a Mechanical Sensor.

• NotintendedforusewithEmergencyExitFixturesorEmergencyExitLights.

• Caution:WhenInstallingLampsinCorrosiveEnvironments,HyLitesuggeststhataHigh-Temperature,Moisture-Resistant,SiliconeGreaseorSealantbeusedto protecttheMetal-threadedbaseoftheLEDLamptopreventWaterand/orMoistureIncursionthatcanleadtoPrematureDegradationoftheLampBaseand eventual Lamp Failure. This is especially recommended for LED Lamp installations near Saltwater bodies.

• InstallingSurge/LightningProtectorsisHighlyRecommendedandhelpstoEliminatePrematureDriverFailurecausedbySurgesandPowerFluctuations.

©2012-2019HyLiteLED,LLC.,USA Formoreinformation,pleasevisit:https://hyliteledlighting.com/ 031219

Installation: HyLite LED Lampsaredesignedtoworkoff100Vto277V,AC.Ballast (if equipped) must be bypassed or removed from the fixture before installing the lamp. Eliminating theBallast savesadditional costs related to Maintenance, Energy Consumption and Performance.By-passingBallastwillalsoensurethatthereisnoEMi/RFinterference.ItisSTRONGLYRECOMMENDED that the Reflector in the Fixture be removed for Optimum Thermal Management and better Heat Dissipation. This will ensure Lumen Maintenance and extend its Working Life. The installer MUST also ensure and verify that NO Part of the installed LED Lamp should touch the Fixture Housing or Components.

Failure to follow these Instructions will result in a Damaged Product and will VOID Warranty. It could also result in an Electric Shock, or Fire.