Before the suction and dischargeflanges are broken - take a "null"reading with the Rotalign® Pro. That is,take a reading which will leave all zerosin the results screen. You do this bysetting up the Pro as you normallywould - then press and thenthe soft key but do not turn theshafts at all! Next press the softkey after which the Pro will tell you "This measurement is questionable!"Ignore the note & press the soft key & then press the yellow resultskey and you will have an all zero “null” alignment!

Now start the “Move” mode bypressing the soft key. Next,observe what changes occur whenthe suction and discharge flanges arebroken. The changes you see areexactly what the pipe strain is doing tothe alignment at the coupling as youare monitoring the shaft centerlines!

You might find 2 mils (.002”) to be avery tight tolerance for pipe strain onsome applications. Some industrialplants have relaxed that to 5 mils(.005”) which might be a better startingpoint. As the people get where theyaccept the 5 mils they themselves willtighten the tolerances.

Have a Grand Day!

Norm Voelzow

Startsweep

M

© V

oelz

ow &

Com

pany

, Inc

. • W

inga

te, N

C 2

004

Pipe Strain

02/13/2004

Voelzow & Company, Inc.P. O. Box 158 • Wingate, NC 28174

Phone: 704-233-9222 • Fax: 704-233-9211E-Mail: [email protected]

Web: http://www.LaserAlignment.net/

Pip

e S

trai

n

Do Not Loosenthe Bolts Yet!

Question: Can we check Pipe Strain with our Rotalign® Pro?Answer: Yes, the Rotalign® Pro is great for checking Pipe Strain!