Laser Scan detectorLaser Scan detector RLS-3060RLS-3060 Basic information & Basic information &
installation of Laser Scan installation of Laser Scan detector detector
OPTEX CO., LTD.Nov. 17 2009
Training purpose only. Do not duplicate.
Training purpose only. Do not duplicate.
Product OverviewProduct Overview
Laser Scan detector RLS-3060 utilizes ‘Time of Flight’ technology.
RLS-3060 does not require any PC for operation. It can be connected to PTZ camera, video transmitter or DVR.
RLS-3060 has 4 detection area segments and linked outputs. It can match PTZ control applications.
RLS-3060 can recognize the size, speed and distance of objects within the 30M range. Processing with our detection algorithm, it recognize human targets and avoids false alarm factors.
Training purpose only. Do not duplicate.
Product FeaturesProduct Features
• 30m radius for 190 degrees• Vertical and horizontal detection area• Unique detection algorithm• Four independently adjustable detection areas for PTZ
camera control• Four independent N.O. outputs• Form C master alarm output• Automatic area setting function• Environmental disqualification circuit• Trouble output• Tamper output
Training purpose only. Do not duplicate.
Why LaserWhy Laser
LASER is an acronym for
Light Amplification by Stimulated Emission of RadiationLaser is an artificial light that does not exist in nature. It has unique characteristics, that makes it different than “ordinary” light.
• Monochromatic
Laser light is extremely pure and consists of a very narrow spectral range. It enables the separation of emitted light from the detector and other sources.
• Directional
The laser can be collimated and travels over long distances with little spread. It enables the detector to achieve a very high resolution detection area.
Training purpose only. Do not duplicate.
What is LaserWhat is Laser
There are gas lasers, solid-state lasers, liquid lasers and semiconductor lasers.
According to medium to make laser light, the wavelength of light is different.
A semiconductor laser is small in size and has very low power consumption.
X-Ray Ultraviolet-Ray
Visible Light Microwave
TV Wave
10 1000K(nm)
400K
Infrared
GaN(Gallium nitride) 400 nm - Blue-violet laser, in Blu-ray Disc and HD DVD drives
AlGalnP 650 nm - DVD drives, Laser pointers
AlGaAs 780 nm - Compact Disc
905 nm - Redscan Redscan InGaAsP 1310 nm - fiber-optic communication
REDSCAN utilize 905nm wavelength Laser (Near Infrared)
Training purpose only. Do not duplicate.
What is LaserWhat is Laser
Why near infrared?Why near infrared?
Near infrared has a high penetrative characteristic compared to other wavelengths and is invisible. It is preferred for intrusion detection e.g. video surveillance.
How affect human health?How affect human health?
Redscan’ s laser is Max. 0.015mW
It is classified as Class 1 of Laser Safety Standard.
(Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50 & IEC60825-1)
It does not affect human health. Not visible to human eye
USA
Food and Drug Administration
Center for Devices and Radiological Health
Training purpose only. Do not duplicate.
Construction of LaserConstruction of Laser
Laser Diode
Avalanche Photo Diode
TX opticRX optic
Scanning mechanism
Signal processing
Output
Training purpose only. Do not duplicate.
Detection principleDetection principle
Scanning mechanism
LDADD
TX optic
RX optic
Signal processing
Time of Flight (TOF) method
By calculating the time during which a emitted beam returns after hitting the object, the distance to the object can be measured.
Sensing resolution = 0.25 degree
At 100ft. (30m) distance, detection width is only 5 inch. (13cm).
Redscan is sampling every 0.25 degree. It means that Redscan protects 180 degree area with 720 beams and 190 degree area with 760 beams.
Training purpose only. Do not duplicate.
Detection areasDetection areas
REDSCAN, RLS-3060 can be installed vertically, horizontally or at an angle. Therefore a horizontal or vertical or inclined detection area can be achieved
Detection range is 100ft. (30m) radius, 190 degree.
Training purpose only. Do not duplicate.
Detection areasDetection areas
REDSCAN, RLS-3060 can be installed vertically, horizontally or at an angle. Therefore a horizontal or vertical or inclined detection area can be achieved
Detection range is 100ft. (30m) radius, 190 degree.
Training purpose only. Do not duplicate.
Conventional PIR Laser Scan Sensor
REDSCANREDSCAN detector has 190 degree detection area. Therefore,
No dead spots
Very flexible and Precise detection area setting
REDSCANREDSCAN has the capability to recognize the intrusion location in 4 detection area segments and is linked to 4
outputs. Therefore,
Ideal match for PTZ camera preset control
Benefits of RedscanBenefits of Redscan
Vertical detection area
Horizontal detection areaHorizontal detection area
Training purpose only. Do not duplicate.
Connection (Analog)
Power supply
Alarm outputs for each area (A1,A2,B1,B2)
× 4
Tamper output Self check trouble output Environmental trouble output
Master Alarm output (N.O./N.C.)
Ethernet port(RJ-45)
Analog PTZ
REDSCAN
PC
Power supply 24VDC/AC
Peripheral equipment
* Set up
* Update software
DVRDVR
Training purpose only. Do not duplicate.
Connection (IP connection) PTZ preset PTZ preset controlcontrol
Power supply 24VAC/DC
TCP/IP
Alarm information Detected human position
Environmental signal Trouble signal
Tamper output
Ethernet port ( RJ-45 )
IP PTZ camera
REDSCAN
Switch
UDP
* Set up
* Update software
Analog
Can receive generic event codes
Generic Event Code
PC with Video/Alarm management software
or NVR
Training purpose only. Do not duplicate.
Feature
• RLS-3060 generates the generic event codes from its communication port.
• PTZ preset control by RLS-3060 via NVR or VMS which has the capability to receive generic event codes through an IP network.
IP connection (Generic event code) IP connection (Generic event code)
Communication methods
Send generic codes to assigned port on UDP
Code format
XXXX_y1 to y9
*“XXXX”: ID number of the RLS-3060 unit (4 –6 bytes). Number is RLS + the host address of the RLS-3060.
Default: RLS126
* y: Status code of RLS-3060 (18 bytes)
* When no event, “⊔“(space) is generated. (Space is expressed as “⊔”, for convenience.)
Example.) When the unit detects in A2 area and also the laser window get dirt, the following event code is generated. “RLS126MOA2⊔⊔⊔⊔⊔⊔⊔⊔⊔⊔⊔⊔SO“.
IP address and port number which the RLS-3060 send the event code to can be changed.
* Default value
IP address: 192.168.0.126
255.255.255.0
Port number: 1234
Training purpose only. Do not duplicate.
Visualized detection area
Easy parameter and detection area setting on PC software
REDSCAN
PC Ethernet port(RJ-45)
Redscan Manager SoftwareRedscan Manager Software
Training purpose only. Do not duplicate.
SpecificationsSpecifications
For reliable installation of Redscan
Training purpose only. Do not duplicate.
Selection of detection patternSelection of detection pattern
Vertical detection area
It creates an invisible wall.
Suitable for inside / outside of perimeter fence / wall or immediate perimeter of building to control PTZ preset.
The minimum interruption time is 100msec. So, need to install unit where people can not run through the detection area otherwise install the unit at an angle. (0 to 45 degree)
Horizontal detection area
It creates a fan like semicircular area.
Suitable for open area and field zone protection with cameras.
Installation height of detector recommended at 28 inch (70cm). If there is a possibility that people can crawl under the area, set the unit at an angle or use multiple units or consider a back-up detector.
Training purpose only. Do not duplicate.
Planning installationPlanning installation
Site survey and hints to planning the location of detector
What does the system protect? Perimeter line, just around the building, between building and perimeter? Select
the detection pattern, vertical or horizontal detection patterns.
How big is the site? Calculate the detection distance required, both in length and width. Then,
consider how many Laser Scan detectors are required.
Are there any potentials of False alarms/Miss alarm? Are there any bushes, trees, vehicles or any objects to obstruct the beam path?
Laser beam can not detect beyond the obstructions.
Unnecessary areas can be masked. But, as much as possible, the detection area should be set not to see any unnecessary area.
Confirm the detection area can be covered by camera Miss alignment of detection area and camera view means that the operator can
not see the crucial image on the screen. The detection area should be within camera view.
Location of Laser Scan Detector The detection area is approx. 100 ft. (30m ) radius, 190 degree and the thickness
of beam is approx. 8 inch (20cm) at 100 ft. (30m) distance. When mounted with a vertical detection pattern, the unit should be installed at a position for the beam to hit the ground squarely.
Training purpose only. Do not duplicate.
Correct installationCorrect installation
Power cables
· As with any electrical wiring, the longer the wire run, the greater the electrical resistance and therefore voltage drop. Use the recommended wire as the per the instructions. Note, increasing the number of detectors powered by the same wire, results in a voltage drop proportional to the number of units added.
· Never run wiring overhead, where accidental damage can occur, while passing underneath.
· Avoid exposed wiring, protect by running wiring through conduit.
Training purpose only. Do not duplicate.
Installation procedures – Vertical detection pattern Installation procedures – Vertical detection pattern
1. Mounting the unit
2. Detection Area setting
3. Sensitivity setting
4. Offset setting.
Training purpose only. Do not duplicate.
Installation hints for Vertical detection Installation hints for Vertical detection patternpattern
Installation should be conducted strictly in accordance to the Installation should be conducted strictly in accordance to the Installation Instructions supplied with the unit.Installation Instructions supplied with the unit.
1. Mount the unit
· The mounting height should be up to 15m (Approx. 50ft.).
Recommended height: 7 - 15m (Approx. 23 – 50 ft.)
· Mount the unit on a wall or other solid surface. An unstable installation could cause false alarms.
· Direct or strong reflected sunlight on the face of the detector can affect the performance of detection. Do not face to sun, long grasses or water surface to prevent false alarms.
Training purpose only. Do not duplicate.
Installation hints (1)Installation hints (1)
. Detection Area setting
Training purpose only. Do not duplicate.
Installation hints (2)Installation hints (2)
. Detection angle setting
Training purpose only. Do not duplicate.
Installation hints (3)Installation hints (3)
Training purpose only. Do not duplicate.
Installation hints (4)Installation hints (4)
3. Detection Area setting
Training purpose only. Do not duplicate.
Detection mode selectionDetection mode selection
Training purpose only. Do not duplicate.
Advantage for InstallationAdvantage for Installation
・ Auto mode (Auto learning)By using this mode, the unit can determine the contours of the site and set the detection area automatically.(The detection range is within the area which is set by the range selector dial.)
Vertical detection area
Ground
Manual setting
The unit follows uneven ground and produce uniform detection coverage.
Note: Detector mounting is critical to achieve maximum detection performance.
Training purpose only. Do not duplicate.
Offset settingOffset setting
Training purpose only. Do not duplicate.
Early detection for fence lines!! REDSCAN can detect a Early detection for fence lines!! REDSCAN can detect a person: Lifting, Climbing or Cutting fencesperson: Lifting, Climbing or Cutting fences
Advantage for InstallationAdvantage for Installation
Normally it’s difficult to create detection areas outside of fence lines, however REDSCAN can do that.
Training purpose only. Do not duplicate.
Advantage for InstallationAdvantage for Installation
REDSCAN saves time for design & installation and therefore costs.
The REDSCAN automatically detects and learns the contours The REDSCAN automatically detects and learns the contours of the ground wherever you install!!, even for uneven of the ground wherever you install!!, even for uneven ground.ground.
Ex. Active photo beam
60m
REDSCAN
60m
Training purpose only. Do not duplicate.
Advantage for InstallationAdvantage for Installation
REDSCAN automatically adjusts for environmental changes.(When the Auto mode switch P2 selected. If P1 position selected, detection area is fixed.)
REDSCAN can refresh the ground shape automatically every REDSCAN can refresh the ground shape automatically every hour for changes in snow or vegetation growth.hour for changes in snow or vegetation growth.
Auto Refresh Auto Refresh area learningarea learning
Training purpose only. Do not duplicate.
Advantage for InstallationAdvantage for Installation
It is not necessary to install several sensors on a building surface. REDSCAN brings a new installation design concept to the market.
REDSCAN can make an invisible wall, it will provide the REDSCAN can make an invisible wall, it will provide the optimum solution for building surface protection!!optimum solution for building surface protection!!
Training purpose only. Do not duplicate.
Advantage for InstallationAdvantage for Installation
It is not necessity to install sensors with fence line for perimeter security. REDSCAN will bring a new installation design to save time and cost.
REDSCAN can be installed at an angle to a wall, reducing REDSCAN can be installed at an angle to a wall, reducing installing cost dramatically!!installing cost dramatically!!
A1
A2
B1B2
Training purpose only. Do not duplicate.
Perimeter surveillance for Narrow boundary!! Perimeter surveillance for Narrow boundary!! REDSCAN can installed in a narrow boundary zone.REDSCAN can installed in a narrow boundary zone.
Advantage for InstallationAdvantage for Installation
Training purpose only. Do not duplicate.
No risk to run through at high speed
Risk to run through at very high speed
Recommended InstallationRecommended Installation
[ Human running ]
Training purpose only. Do not duplicate.
0 degree angle
Min. 33sec at 100m can be detected
Possible to run at this speed
RISK of Running Through
Recommended InstallationRecommended Installation
20 degree angle :
Min. 15sec at 100m speed can be detected
Impossible to run at this speed
* Sensitivity setting : H, Width of Human : 30cm, Human height : 170cm
[ Human running ]
Video
Training purpose only. Do not duplicate.
Recommended Installation Recommended Installation
Mounting Height2m
Mounting Height3m
Mounting Height4m
Mounting Height10m
Mounting Height15m
0 10.8 0.0 0.0 0.0 0.0 0.0
10 17.1 0.4 0.5 0.7 1.8 2.6
20 23.9 0.7 1.1 1.5 3.6 5.5
30 31.6 1.2 1.7 2.3 5.8 8.7
45 46.8 2.0 3.0 4.0 10.0 15.0
Holizontal distance from the unit X (m)Mounting Angle
(Degree)Side view
Minimum interruptionspeed to trigger
(km/h)
X
X
X
X
Training purpose only. Do not duplicate.
Recommended InstallationRecommended Installation
Mounting Height6.6ft.
Mounting Height9.8ft.
Mounting Height13.1ft.
Mounting Height32.8ft.
Mounting Height49.2ft.
0 6.7 0.0 0.0 0.0 0.0 0.0
10 10.6 1.3 1.6 2.3 5.9 8.5
20 14.9 2.3 3.6 4.9 11.8 18.0
30 19.6 3.9 5.6 7.5 19.0 28.5
45 29.1 6.6 9.8 13.1 32.8 49.2
Holizontal distance from the unit X (ft.)Mounting Angle
(Degree)Side view
Minimum interruptionspeed to trigger
(mile/h)
X
X
X
X
Training purpose only. Do not duplicate.
0 ( zero ) degree angle vertical installation
RLS-3060 CAN DETECT detect target 35cm height in the following case
35cm height
0 degree angle
DETECTION
Recommended InstallationRecommended Installation
Training purpose only. Do not duplicate.
0 ( zero ) degree angle vertical installation
RLS-3060 will NOT detect target 30cm height in the following case
30cm height
0 degree angle
NO DETECTION
Recommended InstallationRecommended Installation
Training purpose only. Do not duplicate.
Over 30 ( zero ) degree angle vertical installation
RLS-3060 CAN DETECT target 30cm height in the following case
30cm height
30 degree angle
DETECTION !!
Recommended InstallationRecommended Installation
Training purpose only. Do not duplicate.
No Angle Vertical Mount
But no chance to crawl
Right surface on the wall or fence
0 degree angle vertical mount
Crawling may happen
OK
NG
Detection
No Detectio
n
Recommended InstallationRecommended Installation
Training purpose only. Do not duplicate.
Recommended InstallationRecommended Installation
Maximum detection distance for Person Crawling(m)
0 30 45
Mounting Height4m
57 55 53
Mounting Height8m
53 51 48
Mounting Height12m
50 48 46
Mounting Angle (Degree)
Maximum
detection
distance (m)
Mounting Height (m)
Maximum detection distance for Person Walking(m)
0 30 45
Mounting Height4m
59 59 59
Mounting Height8m
57 56 55
Mounting Height12m
54 52 49
Mounting Angle (Degree)
Training purpose only. Do not duplicate.
Recommended InstallationRecommended Installation
[ Water’s edge]
OffsetOffset
Installation on Water’s edge
Angle installation with Vertical mode
Water reflection Water reflection may cause false may cause false alarm alarm
Video
Training purpose only. Do not duplicate.
Installation procedures - Horizontal Detection Installation procedures - Horizontal Detection PatternPattern
1. Mounting the unit
2. Wiring
3. Detection Area setting
4. Masking far area
Training purpose only. Do not duplicate.
Installation hints for horizontal detection patternInstallation hints for horizontal detection pattern
Installation should be conducted strictly in accordance to the Installation should be conducted strictly in accordance to the Installation Instructions supplied with the unit.Installation Instructions supplied with the unit.
1. Mount the unit
· The mounting height should be around 28 inch. (70cm) in order for the beam to hit waist / hip of people.
· Mount the unit on a wall or a solid surface. An unstable installation could be a cause of false alarms.
· If there are obstacles in the laser path, it can not detect beyond the obstacles.
· Direct or strong reflected sunlight on the face of the detector can affect the performance of detection. Do not face to sun, grasses, water surface to avoid affection.
· Do not install the Redscan unit sideways.
Training purpose only. Do not duplicate.
. Detection Area setting
Installation hints (1)Installation hints (1)
Training purpose only. Do not duplicate.
Installation hints (2)Installation hints (2)
. Detection Area setting
Training purpose only. Do not duplicate.
Advantages for InstallationAdvantages for Installation
Auto mode (Auto learning)By using this mode, the unit can check the shape of the site and set the detection area automatically.(The detection range is within the area which is set by the range selector dial.)
Horizontal detection area
Training purpose only. Do not duplicate.
Advantages for InstallationAdvantages for Installation
Auto mode (Auto Tracing)By using this mode, within the 100ft. (30m) radius 190 degree arc, you can make the necessary detection area by pushing set button and walking the perimeter of required area.
Training purpose only. Do not duplicate.
Laser scan beam needs to be kept parallel to ground.
Recommended InstallationRecommended Installation
Sloping ground
NO DETECTION
DETECTION!!
Horizontal installation
Sloping ground situation
DETECTION!!
DETECTION!!
Sloping ground
Training purpose only. Do not duplicate.
There is a risk to detect though glass windows. Please do not use P1 mode.
Please make detection area by P2 mode or REDSCAN MANAGER.
Recommended InstallationRecommended Installation
Glass window
Through the glass window
Training purpose only. Do not duplicate.
Thank you very much.
All information is provided as references without any warranty of any kind, either expressed or implied, including but not limited to fitness for a particular use. Any user shall assume the entire risk as to the accuracy and use of these information.
Top Related