7/29/2019 Inva Tubular
1/2
IT 500 150 Ah 500 187 430 33.80 60.05 23.80 540 18 9 24 120 480
IT 650 200 Ah 500 187 430 45.00 72.00 21.60 720 24 12 32 160 640
Model Capacity*
IT 500 120 100 86 60
IT 650 160 133 115 88
TECHNICAL SPECIFICATION
Dimenstion (+/-3mm)
Lenght Width Height*
Weight (Kg+/-5%)
Volume of
Electrolyte
(1.220 Sp. Gr)
Liters
Initial
ChargeMinimumAH input
(AH)Dry Filed
Initial Change at ConstantCurrent (A)
Start (up to2.36 vpc)
Finish (up to2.75 vpc)
Constant
PotentialLimitingCurrent(Amps)
Trickle Charge(Current in mA)
Min. Max.
*The height mentioned is upto terminal top.
HIGHER DISCHARGE RATES (OPTIONAL)
Hours 10 5 3 1
1. Fi lling in Specif ic Gravity 1.220 +/- 0.005 at 27C
2. Rest Period 6 - 8 hrs.3. Minimum Ah input 540 Ah for IT500 and 720Ah for IT650
4. In order to reduce the charging time, the following routine may be adopted.For IT500, the initial charging current may be 18A upto 2.36vpc f ollowedby 9A upto 2.75vpc. For IT650, the initial charging current may be 24Aupto 2.36vpc followed by 12A upto 2.75vpc.However, in both cases, minimum Ah input to be given. Under no circumstances,
batterytemperature should exceed 50C. In case the case temperature exceeds 50C,adequate rest to be given till the electrolyte temp. Comes to ambient temp. andcharging to be continued.
5. Conditions of fully charged a) 3 consecutive hourly readings ofspecific gravity and voltage becomesconstant
b) Top of charge voltage will be Around16.2V - 16.5V
c) All cells should gas freely
d) Minimum Ah has been given
6. Specific Gravity at fullychanged condition 1.250 +/-0.005 at 27C
NORMAL RECHARGING INSTRUCTIONS
Recharging through Inverter at constant potential mode of 14.4V with limited current as specified. After battery potential reaches 14.4V, the battery should continue trickle
charge mode at constant potential of 13.8V.
INITIAL CHARGING INSTRUCTIONS
Capacity Ah
TUBULAR500 & 650 INDUSTRIES LIMITED
7/29/2019 Inva Tubular
2/2
Battery Selection Chart
Inverter Rating VA DC input voltage
Back-Up Duration
6 Hrs. 5 Hrs. 4 Hrs 3 Hrs 2 Hrs 1 Hrs
S= Series connection; P= Parallel connection.
300
500
700
1000
1300
2000
12
1224
1224
1224
2448
2448
IT650
2P IT5002S IT500
3P IT5002S IT650
3P IT6502P X 2S IT500
2S X 2P IT6504S IT650
2S X 3P IT6504S X 2P IT650
IT6502P IT5002S IT500
2P IT6502S IT650
3P IT6502P X 2S IT500
2S X 2P IT6504S IT650
2S X 3P IT6504S X 2P IT500
IT5002P IT5002S IT500
2P IT6502S IT500
3P IT6502P X 2S IT500
2S X 2P IT6504S IT650
2S X 3P IT6504S X 2P IT500
IT500IT650
2S IT500
2P IT5002S IT500
2P IT6502S IT500
2S X 2P IT5004S IT500
2S X 3P IT6504S IT600
IT500IT500
2S IT500
IT6502S IT500
2P IT6502S IT650
2S IT6504S IT500
2S X 2P IT6504S IT500
IT500IT500
2S IT500
IT6502S IT500
2P IT6502S IT650
2S IT6504S IT500
2S It6504S IT500
is a product of ISO 9001 AND ISO 14001 CERTIFIED FACTORIESTUBULAR