INFRARED THERMOGRAPHIC SYSTEMS AND THEIR
MECHANICAL APPLICATIONS.
7/30/2019 Infrared thermographic system
2/40
ABSTRACT
Infrared thermography is the science of detecting and measuring variations in heat emitted by an
object and transforming them into visible images. Infrared Thermal Imaging is an electronic
technique which quite literally allows us to see thermal radiations. With this new capability,
plant maintenance personnel have recognized Infrared Thermal Imaging as one of the most
versatile and effective condition monitoring tools available today. Infrared thermography can
detect numerous conditions in which an anomaly is characterized by an increase or decrease in
surface temperature or retained residual heat. These include high resistance heating of
connection points in electrical systems; heat generated by abnormal friction in bearing surfaces;
7/30/2019 Infrared thermographic system
3/40
differences in heat transfer across surfaces, such as a wall or boiler; and moisture retained in
insulation in a roofing system. Infrared imaging, when combined with software analysis tools,
may also be used to quantify these types of thermal differences.
Infrared Thermal Imaging is an excellent condition monitoring tool to assist in the reduction of
maintenance costs on mechanical equipment. The technique allows for the monitoring of
temperatures and thermal patterns while the equipment is online and running under full load.
Most mechanical equipment has allowable operating temperature limits that can be used as
guidelines. Unlike many other test methods, Infrared Thermal Imaging can be used on a wide
variety of equipment including pumps, motors, bearings, pulleys, fans, drives, conveyors etc.
Advantage of these methods is contactless measurement, usually very fast and without any
destructive influence on tested/measured objects
CONTENTS
List if figures..5 Notations....6
7/30/2019 Infrared thermographic system
4/40
Introduction..7 History..8 Theory..9 Common infrared thermometer construction.13 Surface temperature in infrared thermometers...14 Elements in infrared thermometer..15 Temperature measurement calculations.19 Types of infrared thermometers.22 Advantages and disadvantages of IR thermometry....25 Non-destructive evaluation.26 Application.29 Conclusion..40 Future of IR imaging...41 References...42
LIST OF FIGURES
Fig 3.1: Splitting of incident energy.10
Fig3.2: Spectral Distribution....11
7/30/2019 Infrared thermographic system
5/40
Fig 4.1: Optical arrangement in IR detector......13
Fig 4.2: Block diagram of IR thermographer.13
Fig 5.1: Hemispherical IR thermometer15
Fig 6.1: Field of view..17
Fig 10.1: Fast transient NDE27
Fig 10.2: Steady state NDE.....28
Fig 11.1: Thermographs for comparing working of motors30
Fig 11.2: Thermograph of belt and pulley.30
Fig 11.3: Thermograph of a faulted bearing......31
Fig 11.4: Thermograph of a steam trap.32
Fig 11.5: Thermograph of a defective steam trap...33
Fig 11.6: Thermograph of a rotary kiln.....34
Fig 11.7: Thermograph of a blower system...35
NOTATIONS
WI = incident energy received by the object, W
WR = energy reflected off the objects surface, W
WT = energy transmitted by the object, W
WA = energy absorbed by the object, W
7/30/2019 Infrared thermographic system
6/40
E = emissivity
= Stefan-Boltzmann Constant = 5.6703 10-8
, W/m2K
4
T = absolute temperature,oK
A = emitting area, m2
TIR = Surface temperature,K
esurf = Emissivity of the surface
Tback = Background Temperature,K
TIR, Ref = Emitter temperature.K
TIR, smpl = sample surface temperature,K
TFOV = The uncertainty in temperature due to variations in field of view,K
TLin = The uncertainty in temperature due to non-linear performance of the
imager.K
T = The total uncertainty in the measured surface temperature,K
1.0 INTRODUCTION
Temperature is one of the important parameters to tell the condition of internal process, material
and even quality of the desired output. A qualitative but accurate conclusion can be drawn by
observing the temperature profile of any surface. On the other hand higher temperature also
indicates obvious loss of energy in the form of heat. Therefore temperature monitoring would
give ample indication of the condition of the material, process quality and explore the possibility
of energy conservation avenues. In recent years, many temperature monitoring techniques have
been in use in our industries. These techniques find their application based on the measurable
temperature range, sensitivity and ease in application. With the on-line condition monitoring
7/30/2019 Infrared thermographic system
7/40
technology becoming an inevitable part of maintenance strategy in todays scenario, non -contact
type temperature monitoring methods have become more popular. Infrared Thermography is
such a non-contact type technique which provides a fast, reliable and accurate temperature
profile of any material surface. This paper deals with various application of infrared
thermography including the justification of energy saving potential in many cases.
Infrared (IR) energy is part of the electromagnetic spectrum and behaves similarly to visible
light. It travels through space at the speed of light and can be reflected, refracted, absorbed, and
emitted. The wavelength of IR energy is about an order of magnitude longer than visible light,
between 0.7 and 1000 m. All objects emit infrared radiation as a function of their temperature.
Infrared energy is generated by the vibration and rotation of atoms and molecules. The higher the
temperature of an object, the more the motion and hence the more infrared energy is emitted.
This is the energy detected by infrared cameras. The cameras do not see temperatures, they
detect thermal radiation. At absolute zero (273.16C, 459.67F), material is at its lowest
energy state so infrared radiation is minimized.
Infrared thermography is the technique for producing an image of invisible (to our eyes) infrared
light emitted by objects due to their thermal condition. An image produced by an infrared camera
is called a thermogram or a thermograph. Infrared (IR) thermographic systems, or IR imagers,
provide images that represent surface temperatures, by measuring the magnitude of infrared
radiation emanating from the surface of an object. Because IR imagers see the radiation naturally
emitted by objects, imaging may be performed in the absence of any additional light source.
Modern IR imagers resolve surface temperature differences of 0.1C or less. With this high
sensitivity, they can evaluate subtle thermal phenomena, which are only revealed in the form of
slight temperature gradients. Some applications that employ IR thermography include:
inspections for predictive maintenance, non-destructive evaluation of thermal and mechanical
properties, building science, military reconnaissance and weapons guidance, and medical
imaging.
7/30/2019 Infrared thermographic system
8/40
2.0 HISTORY
The first patent for a total radiation thermometer was granted in 1901. The instrument used a
thermoelectric sensor; it had an electrical output signal and was capable of unattended operation.In 1931, the first commercially-available total radiation thermometers were introduced. These
devices were widely used throughout industry to record and control industrial processes. They
are still used today, but mainly used for low temperature applications. The past 20 years, non-
contact infrared thermometer in the rapid development of technology, performance, continuous
improvement, function continuously enhanced, increasing variety, scope also expanded its
market share year by year.
3.0 THEORETICAL BASIS FOR RADIATION
MEASUREMENTS
Heat is transferred from one body to another through conduction, convection, or radiation.
Radiation is a process where heat energy in a form of electromagnetic waves is emitted by a hot
object and absorbed by a colder object. Most of this radiation is in the infrared (IR) region of the
electromagnetic spectrum, but some also spreads into the visible light band. The IR wavelength
band stretches from 0.7 to 1000 microns, however practical IR measurement systems use only
7/30/2019 Infrared thermographic system
9/40
certain wavelength bands between 0.7 and 14 microns because the radiation is the strongest in
this range.
If an object is exposed to IR energy radiated by a heat source, such as an electric heater, light
bulb, sun, or other source, the energy reaching the object is called incident energy. Part of this
energy is reflected off the object surface. Theoretically, the objects coefficient of reflectivity can
vary from 0 (no reflection) to 1.0 (100% reflection). Rough, matt surfaces have low reflectivity.
Polished and glossy surfaces, especially metals, have high reflectivity.
Depending on the object material, thickness, and the radiation wavelength, part of the radiation
can go through the object or be transmitted. The coefficient of transmission can vary from 0 (no
energy transmitted through object) to 1.0 (100% energy transmitted through object). High
transmittance examples include glass, quartz, plastic film, and various gasses. Materials opaque
in the IR spectrum have close to zero transmission coefficients.
The remaining energy is absorbed by the object and raises its temperature. A hypothetical body
that has no reflection or transmission and absorbs all incident energy across the entire spectrum
has a coefficient of absorption equal to 1.0 and is called a blackbody. Real-life objects, referred
to as gray bodies, have coefficients of absorption that fall between 0 and 1.0.
Incident energy, WI, is defined as:
WI = WR+ WT + WA
Fig 3.1Splitting of incident energy
7/30/2019 Infrared thermographic system
10/40
When incident heat energy reaches an object, part of this energy is reflected, part passes through
the object, and the rest is absorbed. The coefficients of reflection, transmission, and absorption
depend on the object material and surface finish and on the wavelength spectrum of the incident
energy.
As the object absorbs energy and heats, it also emits energy. When an object is in a state of
thermal equilibrium, the amount of energy it absorbs (WA) equals the amount of energy it emits
(WE): WA = WE. When an object absorbs more energy and its temperature increases, the amount
of radiation it emits also increases.
IR thermometry is based on the fact that any body (solid, liquid, or gaseous) that has a
temperature above absolute zero (0oK or -273
oC) emits radiant energy. This energy is
proportional to the forth power of the body temperature, and the bodys ability to absorb and
emit IR energy is called emissivity. Energy radiated by a body can be expressed as follows:
W = E A watts.
Fig 3.2 Graph showing relation between wavelength and temperature
7/30/2019 Infrared thermographic system
11/40
When the temperature of a hypothetical blackbody increases, the radiated IR energy also
increases. Temperature T2 is several times greater than temperature T1. The rise between 1 and
10 microns is most pronounced.
Emissivity can range from 0 to 1 for various bodies. A hypothetical blackbody emits and absorbs
all energy and thus has an emissivity equal to 1. Real-life objects have an emissivity between 0
and 1.
When an IR thermometer measures an objects temperature, consider the energy that actually
enters the lens. That is, in addition to emitting energy related to its own temperature, the object
may reflect energy coming from another source, or transmit energy passing through it from a
source behind it. Thermal radiation is largely a surface phenomenon, because most materials arenot transparent to IR. As a result, it is the material properties of the surface of an object that
determine emittance. Polished metals have low emittance, but a thin layer of paint can transform
them to high emittance. For materials that are opaque to IR radiation, emittance can be
considered the complement of reflectance (the amount of incident radiation that is reflected by a
surface), expressed by 1-e. It is important to realize that because no real surface has an emittance
e=1, the radiation that is viewed as coming from an object is always a combination of emitted
and reflected radiation, termed radiosity, and it contains information regarding both the
temperature of the object and its surroundings. Special techniques described within are necessary
to distinguish the two components and obtain accurate surface temperatures for the object of
interest. When imaging outdoors, it should be taken into account that the sun is a significant
source of IR radiation, particularly in the shorter wavelengths of the IR band.
For accurate measurements, survey the surrounding area for possible sources of extraneous IR
radiation and choose the thermometer position and aiming angle to minimize the effects of those
sources
7/30/2019 Infrared thermographic system
12/40
4.0 COMMON INFRARED THERMOMETER CONSTRUCTION
The most basic design consists of a lens to focus the infrared thermal radiation on to a detector,
which converts the radiant power to an electrical signal that can be displayed in units of
temperature after being compensated for ambient temperature.
7/30/2019 Infrared thermographic system
13/40
Fig 4.1 Optical Arrangement
Fig 4.2 IR imager flow diagram
This configuration facilitates temperature measurement from a distance without contact with the
object to be measured. As such, the infrared thermometer is useful for measuring temperature
under circumstances where thermocouples or other probe type sensors cannot be used or do not
produce accurate data for a variety of reasons.
7/30/2019 Infrared thermographic system
14/40
The majority of IR detectors are either single-wavelength (also called single-color), or dual-
wavelength (also called two-color) type. The single-wavelength detectors measure IR energy
within a certain wavelength band, and the instrument calculates object temperature based on the
detector output and the preset emissivity. Some thermometers have adjustable emissivity, and
most simple units have fixed emissivity.
Dual-wavelength detectors measure energy at two different wavelength bands, and the
instrument calculates temperature based on the ratio of the two readings. If emissivity or the
energy changes by the same amount at both bands, the measurement accuracy is not affected.
Emissivity or the amount of radiated energy may change due to object change or movement, lens
contamination or misalignment, or view obstruction. The dual-wavelength detectors drawback
is higher cost and lower accuracy under certain conditions
5.0 SURFACE TEMPERATURE INFRARED THERMOMETERS
We have seen that a radiation source with characteristics close to that of a blackbody could beconstructed by assuring multiple reflections within a cavity. Fig. 8 illustrates a device for
measuring the temperature of the surface of an object based on this principle
Fig 5.1 Surface temperature infrared thermometer
7/30/2019 Infrared thermographic system
15/40
Radiation from the target is multiply reflected from the hemispherical mirror. A detector receives
radiation through a small opening in the reflector. The radiation multiply reflected between the
mirror and the target appears to the detector to be from a blackbody. A commercial thermometer
using this principle can read the temperature of targets with emittance as low as 0.6 without
correction. The reflector must be placed close to the surface being measured to exclude
extraneous radiation and prevent radiation losses.
6.0ELEMENTS OF INFRARED THERMOMETERS
6.1 DETECTORS
Based on the principle of operation, IR detectors fall into one of two categories: thermal
detectors and photo detectors (photodiodes). Thermal IR detectors absorb the incident energy,
raise the sensing element temperature, and change the detectors electrical properties:
thermopiles generate thermoelectric voltage, bolometers change resistance, and pyroelectric
devices change their polarization. In general, they are slower than photo detectors.
A thermopile is made by connecting several thermocouples in series and placing their hot
junctions in contact with a black body that absorbs the incident IR energy and heats the hot
junctions. The cold junctions are placed in the area of the detector with adequate heat sinking.
These detectors have fast response, broad band, large dynamic range, and are frequently used in
general-purpose, automotive, air conditioning, and human-body thermometers.
Bolometers use a slab of material that changes its resistance in response to a change of
temperature. The circuit converts resistance change to a voltage change, which is further
processed by the instrument. Bolometers are frequently used for measuring low-level IR energy,
often as an attachment to a telescope.
Pyroelectric devices become electrically charged when their body temperature changes. To
produce a usable signal, the incident IR energy has to pulse. The output peak-to-peak AC
signal is proportional to the pulse energy. Since energy emitted by measured objects is usually
steady, thermometers that use pyroelectric detectors have a mechanical or optical chopper in
front of the sensor. These sensors are used in many home security systems.
7/30/2019 Infrared thermographic system
16/40
Photo detectors are built on a silicon substrate with an IR sensitive area that releases free
electrons when impacted by the photons. The flow of electrons produces electrical signals
proportional to the incident energy. These detectors are often used as arrays in thermal imaging
systems.
A detector needs protection from the environment, and the selected window material must allow
the correct wavelength band to pass through with minimum attenuation. A zinc sulfide or
germanium window is best for the long-wavelength detectors, glass is suitable for short-
wavelength detectors, and quartz for the mid-wavelength spectrum. Some instruments use a
fiber-optic light guide to direct the radiation to the detector.
6.2 OPTICAL SYSTEMS
The optical system of an IRT may be composed of lenses or mirrors or combinations of both.
Mirror systems have been common mainly in fixed focus optical systems. To vary the focus of
an optical system requires that at least one element be movable. Providing for this motion in
mirror systems is often more complicated than in lens systems. The selection of lens and window
materials is always a compromise between the optical and physical properties of the material and
the desired wavelength response of the pyrometer.
6.3 DATA ACQUISITION AND IMAGE PROCESSING
Collecting image data is an important part of operating a real-time imager. The data are
commonly recorded for later analysis, assembly into reports, etc. Continuous video signals may
be recorded on tape or with the aid of a computerized video digitizer. In steady-state thermal
situations a single IR image would be generated by averaging a number of frames over a period
of time. Transient thermal situations are usually recorded continually, and a series of images are
stored over time.
7/30/2019 Infrared thermographic system
17/40
6.4 FIELD OF VIEW
Fig 6.1 Field of view
The key specifications and considerations for any IR thermometer application are field of view
(FOV) and distance; spectral band; response time; accuracy and repeatability; emissivity of the
object or media being measured; media between the object and IR thermometer, such as vacuum,
air, steam, gas, glass, or other; object temperature range; mounted or hand-held application; and
type of output signal or display.
The FOV characterizes the diameter of a circle (target) that the IR detector will see at a certain
distance from the measured surface. However, there is always a minimum target diameter that
depends on the optical system and detector size. The detector measures and averages
temperatures of all objects within the target area. FOV is commonly called distance-to-spot size
ratio and is a ratio of the distance between the meter and the target to the diameter of the
target.For example, a 10:1 distance-to-spot size ratio means that if a measured surface is located
10 inches from the thermometer it will measure and average the temperature of a circle with 1
in.diameter. Move the thermometer away to 20 in. and the target will increase to 2 in., and so on.
A thermometer with a 1:1 ratio will measure within a one-foot diameter circle when held onefoot away from the target.Thermometers designed for measurements of small areas have a very
narrow FOV and measure temperatures of objects less than a tenth of an inch. For example, such
a thermometer held near a component on a pc board will measure the temperature of just that
component and ignore the components around it.
7/30/2019 Infrared thermographic system
18/40
7.0 Infrared Temperature Calculations
In order to obtain quantitative surface temperatures, raw thermographic data may need to be
extracted from the imaging system and processed in a separate mathematical program. The
image-processing component of the imaging system is used to extract data from the thermal
image and export them in appropriate arrays of text values to be synchronized with spatial
coordinates. The result for temperature at each data point should be calculated with the correct
emittance and a location-specific background level. The calculated IR temperature for the
reference emitter may be compared to direct contact measurements, and deviations may be used
to scale the rest of the IR data. Separate data sets may be merged together to combine data from
different views.
Equation given below, shows an expression for calculating a surface temperature, TIR, from the
total thermal radiation represented by the variable Te=1, the emittance of the surface, esurf, and the
background radiation level represented by the variable Tback. Te=1 is an equivalent blackbody
temperature for the surface being measured. Tbackis the equivalent blackbody temperature for the
background thermal radiation level as measured at each location with the aid of an applied
mirror. Values for both Te=1 and Tback are obtained from the thermographic system by setting
emissivity to unity. Conversely, setting emittance to less than one should cause the IR image-
processing component of the imaging system to process the image data using the calculation
using the equation,
This equation is used to determine both the apparent reference emitter temperature, TIR, Ref, (as
measured by IR imaging) and the apparent sample surface temperature, T IR, smpl. The difference
7/30/2019 Infrared thermographic system
19/40
between TIR,Refand the direct contact measured value, TDC,Ref, may be applied to correct TIR,smpl
and to arrive at the final IR surface temperature result, T. This correction should be made for
each temperature datum and for each IR image, to produce arrays of temperature values.
Final data sets merge spatial location coordinates with temperature values. The real distances
between location markers on the specimen are measured, and a coordinate system is used to
create temperature/location data pairs. The temperatures may be distributed linearly.
Temperature data are then made a function of spatial coordinates, mapped to the appropriate
coordinate system.
7.1 Infrared Temperature Uncertainty
The thermographer usually wants to estimate the uncertainty in temperature data. Errors in esurf
should be treated as a source of undefinable systematic uncertainty, esurf, and may be analyzed
by propagating uncertainty. Errors in Te=1 and Tbacklead to random uncertainties, Te=1 and Tback.
Te=1 and Tback are usually closely related to equipment specification for Noise Equivalent
Temperature Difference (NETD). To analyze error propagation, the sum of the squares of partial
differentials of Equation for TIR are calculated with respect to variables Te=1, Tback, and esurf,
which leads to one possible solution,as shown. The uncertainty in T IR, TIR, is then calculated
using Equation:
Values for both TIR,smpl and TIR,Ref are obtained using this equation. The uncertainty in the
direct contact measurement of the reference emitter surface temperature, T DC,Ref, is determined
from the overall system accuracy of the direct contact sensor combined with any errors
associated with adjustments that correct for gradients in the surface material. The uncertainty
arising from variations across the field of view, TFOV, is determined from the magnitude of
deviations in heavily averaged data for an isothermal plate that fills the section of the field of
7/30/2019 Infrared thermographic system
20/40
view being used. The uncertainty arising from non-linear performance or calibration of the
imager, TLin, is determined by evaluating TIR for a temperature controlled and separately
measured target for a range of temperatures and evaluating how deviations change over that
range. The total uncertainty in the measured surface temperature, T, is obtained from Equation :
8.0 TYPES OF INFRARED THERMOMETERS
The following is a convenient classification of IRTs:
Broadband thermometers
Band-pass thermometers
Narrow band thermometers
Ratio thermometers
Fiber optic thermometers
8.1 BROADBAND THERMOMETERS:
Broadband thermometers have usually been the simplest IRTs, with spectral responses from 0.3
microns wavelength to an upper limit of 2.5 to 20 microns (m), determined by the lens or
window material. They have been termed total radiation thermometers because, in the
temperature ranges of normal use they measure a significant fraction of all the thermal radiation
emitted by the object whose temperature is being measured.
8.2 BAND-PASS THERMOMETERS:
Band-pass thermometers were initially derived from simple, broadband thermometers. Lens,
window, or filter characteristics were selected to view only a selected portion of the spectrum.
7/30/2019 Infrared thermographic system
21/40
The 5 0.2m band-pass was used to measure glass surface temperature because glass emits
strongly in this region, but poorly below or immediately above this band.
8.3 NARROW BAND THERMOMETERS:
Narrow band thermometers operate over a narrow range of wavelengths. The spectral response
of many narrow band thermometers is determined by the optical filter used. Such narrow band
thermometers are used as general purpose instruments over the temperature range of interest. For
example, a thermometer using a silicon cell detector will have a response that peaks at 0.9m.
The upper limit of usefulness is about 1.1m. Such a thermometer can only be used at
temperatures above 600C (1100F).
8.4 RATIO THERMOMETERS:
A ratio thermometer measures radiated energy in two narrow bands and calculates the ratio of
the two energies. This ratio is a temperature-dependent function. The temperature measurement
is not primarily dependent on the energy in the two bands, only on the ratio of the two energies.
Therefore, any influence that affects the amount of energy in each band by the same percentage
has no effect on the temperature indication. Changes in target size have no effect. If the
emissivity of the target is the same at both wavelengths, the indicated temperature is not changed
by changes in emissivity. Unfortunately, this condition is not fulfilled by all oxidizable materials.
For other materials, the ratio techniques may reduce or eliminate changes in indicated
temperature caused by changes in surface finish. The ratio technique may reduce the effect of
energy absorbing materials such as particulates or C02 between the target and the thermometer,
if the percentage of absorption is the same at each wavelength.
8.5 OPTICAL PYROMETERS
Although optical pyrometers are no longer manufactured in significant numbers, there areprobably hundreds of thousands in everyday use, and they are sufficiently unique in design and
use to warrant a separate discussion. An optical pyrometer measures the radiation from the target
in a narrow band of visible wavelengths, centered at about 0.65 m in the red/yellow portion of
the spectrum. The most commonly used optical pyrometers are manually operated. The operator
sights the pyrometer on the target. At the same time he can see in the eyepiece the image of an
7/30/2019 Infrared thermographic system
22/40
internal tungsten lamp filament. The operator matches the filament color to the target by varying
the current through the filament with a rheostat, and when the target image and the tungsten
filament image are the same color, the target temperature can be read from a scale on the rheostat
knob. When the target and filament colors are the same, the filament image apparently vanishes,
so these pyrometers have also been called disappearing filament pyrometers.
8.6 FIBER OPTIC THERMOMETERSIn fiber optic thermometers, the infrared radiation from the target is guided to the detector by a
light guide. The first such sensors used a 1/8 in. diameter sapphire rod to pick up energy from the
target and transmit it to a detector. Contemporary fiber optics pyrometers use a flexible bundle of
glass fibers with or without a lens. The spectral response of these fibers extends to about 2 m,
though some exotic materials such as fluorides have a wider band pass. Some are useful at target
temperatures as low as 100C (212F). Fiber optic thermometers are especially useful where it is
difficult, dangerous or impossible to obtain or maintain a clear sighting path to the target, as in
pressure or vacuum chambers. Fiber optic thermometers have also been used to measure
temperatures of turbine blades in gas turbines, and the temperature of small objects in induction
heating coils.
9.0 ADVANTAGES AND DISADVANTAGES OF IR THERMOGRAPHY
The following points spell the advantages and disadvantages of this technique.
7/30/2019 Infrared thermographic system
23/40
9.1 Advantages:
It is a non-contact type technique. Fast, reliable & accurate output. Minimize preventive maintenance and troubleshooting time. Detect problems quickly, without interrupting service. A large surface area can be scanned in no time Presented in visual & digital form. Software back-up for image processing and analysis. Requires very little skill for monitoring.
9.2 Disadvantages:
Cost of instrument is relatively high. effects of thermal losses (convective, radiative, conductive) perturbing thermal contrasts Unable to detect the inside temperature if the medium is separated by
glass/polythenematerial etc.
10.0 Non-Destructive Evaluation (NDE)
10.1 Fast Transient NDE
7/30/2019 Infrared thermographic system
24/40
Fast transient thermal imaging is based on the time-evolution of surface temperatures on test
specimen during heating or cooling. Variations in temperature depend on the heat flow through
the object; heat flow is sensitive to cracks, delaminations, voids, and changes in material
properties. In a typical setup, flash equipment is used to generate a heat pulse, and the surface
temperature of the test specimen is monitored with an IR imager. The pulse duration and the total
energy delivered over the length of the pulse depend on the material properties and the nature of
the defect to be detected. A series of approximately 10 to 30 frames is recorded with frame rates
up to 80 Hz with scanners or 1 kHz with FPA imagers. In the absence of thermal pulse
equipment and a high speed imager, transient NDE can be successfully performed on some
specimens, particularly those with low thermal conductivity. Figure 6 shows several frames
taken at 10 second intervals after a steady IR heat source was applied to the back side of a
composite truck bed panel. The well bonded portions warm faster on the opposite, imaged side.
An image sequence like this can already be very informative when visually inspected by a
technician experienced in interpreting thermograms. However, image post-processing can greatly
enhance images and reveal features that are hidden in the unprocessed image. Post-processing
includes averaging of image sequences, coloration with different palettes, image subtraction and
edge enhancement. Complex processing is possible, including Fourier transformation of time
sequence images and tomography, if sufficient computer power is available to perform these
tasks. Tomography analysis translates the time image sequence into a three-dimensional object
sequence; defects can then be located in depth as well as in the image plane even though data are
collected only at the surface.
7/30/2019 Infrared thermographic system
25/40
Fig 10.1 Fast Transient NDE
The, white circle, horizontal stripes, and dots are the adhesive glue pattern between two layers of
a composite truck bed panel assembly. The pattern is relieved by the transient heat flow induced
by exposing the panel to radiant heat source on one side and imaging it from the opposite side
(10 seconds between each frame). The vertical lines are due to corrugated surface of the panel.
10.2 Steady-state NDE
Fast transient thermography can provide a more robust non-destructive evaluation technique than
steady-state thermography, but its use has been limited because it requires expensive thermal-
pulse equipment and storage of a large number of data for each specimen. Steady-state IR
thermography, by contrast, is much less expensive, requiring minimal equipment and data
storage. Near steady-state thermography could be used for NDE during production phases where
temperature cycles have been applied to parts, for example the cool-down period after paint
baking, adhesive curing, or injection molding of plastic parts. The required temperature
difference between the part to be evaluated and the environment depends on the material,
7/30/2019 Infrared thermographic system
26/40
geometry, and size of the part; the size and nature of the defects being sought; and the minimum
resolvable temperature difference of the IR imager being used. This difference can be as small as
a few degrees Celsius. For example, the figure shows an IR thermogram of a composite truck
bed panel after reaching steady state with a radiant heat source. Gradients are not as sharp in fast
transient thermography when imaging materials with high thermal conductivity. Post processing
can improve image quality as shown in the image to the right.
Fig 10.2 Steady state NDE
11.0 APPLICATIONS
Infrared Thermal Imaging is an excellent condition monitoring tool to assist in the reduction of
maintenance costs on mechanical equipments. The technique allows for the monitoring of
7/30/2019 Infrared thermographic system
27/40
temperatures and thermal patterns while the equipment is online and running under full load.
Most mechanical equipment has allowable operating temperature limits that can be used as
guidelines. Unlike many other test methods, Infrared Thermal Imaging can be used on a wide
variety of equipment including pumps, motors, bearings, pulleys, fans, drives, conveyors etc.
This section will explain the benefits of Infrared Thermal Imaging as a condition monitoring tool
for plant mechanical systems.
11.1 IMPROVED TROUBLESHOOTING
Infrared Thermal Imaging definitely should be one of the tools that are selected for motor and
rotating equipment inspection. Thermographic examination can help technicians use the other
tools, such as vibration analysis, more effectively. If a thermal anomaly is found, then the other
tools can be employed to help isolate the cause of the problem.
11.1.1 MOTORS AND GENERATORS
When considering electric motors and generators, operating temperatures and thermal patterns
can be a valuable key in a predictive maintenance program. All motors have a normal thermal
pattern as well as given maximum operating temperature. This temperature is usually stated on
the nameplate of the motor and is normally given as a rise in degrees C above the ambient air
temperature. Most motors are designed to operate in ambient temperatures that do not exceed 40
C. Conditions such as inadequate air flow, partial discharge, unbalanced voltage, bearing failure,insulation failure and degradation in the rotor or stator can be identified with an Infrared Thermal
Imaging monitoring program. Abnormal thermal patterns can also identify misalignment in
couplings when these devices are used in conjunction with motors. Figure shows the thermal
patterns of two motors, where there is a marked overall temperature rise on the motor on the left,
indicating a possibility of abnormal operation.
7/30/2019 Infrared thermographic system
28/40
Fig 11.1 IR imager of motor
11.1.2 BELTS AND PULLEYS
Belts and pulleys are good candidates for Infrared Thermal Imaging inspection. The interaction
of the pulley wheel and the belt generates friction as the belt contacts and then leaves the pulley
surface. Additionally, the continuous tension and compression of the belt causes internal friction.
Both of these processes result in heat being generated which can be seen with the infrared
camera. Comparing the thermal patterns of several pulley belt systems can provide clues to
improper operation. The temperature distribution across a pulley sheave should be uniform if
everything is working as intended.
Fig 11.2 IR Image of pulley
11.2 PROVIDE EVIDENCE OF PROPER INSTALLATION
11.2.1 BEARINGS
7/30/2019 Infrared thermographic system
29/40
Bearing problems are generally found by a comparison of surface temperatures; comparing one
bearing to another working under similar conditions. Overheating conditions are documented as
hot spots within the infrared camera and are usually found in comparing equipment to
equipment, end bell to end bell (for the same type of bearings) and stator to end bell temperatures
(determined by motor design and configuration).
Fig 11.3 IR Image of bearing
Vertical motor pump combination displaying elevated temperature in lower thrust bearing.
11.3 REDUCE OPERATING COSTS(Leaking or Blocked Pipes and Valves)
11.3.1 STEAM TRAPS
Steam is an efficient way to transport heat energy. The latent heat needed to transform water into
the gaseous state, steam, is extremely large. This means that large amounts of heat energy can be
transported with a minimum temperature differential to the environment. This equates into lower
energy and insulation costs.
When steam arrives at the site where heat energy is needed, it condenses, thereby releasing the
large latent heat it was carrying. The condensate formed by this process must be removed by the
7/30/2019 Infrared thermographic system
30/40
steam system and returned to the boiler where it is turned back into the steam and the cycle is
repeated.
The steam trap performs this function; to hold back live steam while allowing gases and
condensate to pass through. This allows more energy to be obtained from the steam, thus raising
a steam system's overall efficiency.
Fig 11.4 IR image of steam trap
In these two photos of steam traps, the Infrared Thermal Imaging photo on
the left shows the point of leakage.
Steam traps, like any mechanical device, eventually fail. Most are designed to fail in the open
position to maintain steam system operation. When they fail in the open position, they "blow"
live steam. This costs energy dollars which the steam trap was installed to conserve.
Occasionally, steam traps fail in the closed position. This causes condensate back up in the steam
system with potentially disastrous results.
Fig11.5 IR image of faulty steam trap
7/30/2019 Infrared thermographic system
31/40
Thermogram and visible image of a failed inverted bucket steam trap.
Properly performed Infrared Thermal Imaging can identify steam traps that are blowing steam as
well as those that may fail closed. Steam traps are sometimes located in inconvenient areas
where they are hard to reach using other NDT technologies. This fact makes trap diagnosis by IR
especially useful.
11.3.2 FURNACE & REFRACTORY
A refractory material is basically a high temperature insulator. They are usually a non-metallic
ceramic type of material and are commonly supplied in brick form. Refractory materials are used
inside furnaces, ovens, boilers, hot storage tanks and other equipment that produces or contains
extremely hot temperatures.
Using Infrared Thermal Imaging to inspect refractory begins with the assumption that a uniform
temperature inside a vessel will result in uniform warming of its exterior as heat is conducted to
the vessel's walls.
An ideal vessel would have a perfectly uniform temperature on its external surface. If a crack or
other defective conditions existed in the insulating medium, the exterior surface would increase
in temperature in direct proportion to and in the exact location of the defect. Thus, the defect
would be obvious based on the non-uniform conductance of heat into the exterior surface. If the
exterior metal is threatened or a safety hazard may exist, absolute temperature measurements ofthe hot areas become important.
In normal practice, there are other structural variations which cause non-uniform heat patterns in
addition to the defects; these include grid work, refractory type variations, port holes, catwalks,
etc.
11.3.3 ROTARY KILNS
In the manufacture of cement the raw materials are ground together, the mixture is heated until it
fuses into a clinker, and the clinker is ground into a fine powder. The heating is usually
accomplished in rotary kilns which look like huge rotating pipes, sometimes hundreds of feet
long. The kilns are slightly tilted from the horizontal, and the raw material is introduced at the
upper end, either in the form of a dry rock powder or as a wet paste composed of ground-up rock
and water. As the charge progresses down through the kiln, it is dried and heated by the hot gases
7/30/2019 Infrared thermographic system
32/40
from a flame at the lower end. After it leaves the kiln, the clinker is cooled quickly and ground,
and then conveyed by a blower to packing machinery or storage silos.
Fig 11.6 IR image of rotary klin
Thermal patterns indicate refractory damage in this lime kiln.
The refractory lining of the kilns eventually wears out and must be replaced. If it is not, the steel
shell can overheat and fail. Infrared Thermal Imaging is ideally suited for locating and measuring
the temperature of areas where refractory has failed. Continuous tracking allows the kiln
operators to maximize the amount of time they can operate until a shutdown for refractory repair
is necessary.
11.4 IMPROVE THE EFFICIENCY OF A PROCESS
11.4.1BLOWER SYSTEMS
Blower systems can be used to move materials through pipes from one process or location to
another. An example might be a system to deliver coal dust to a boiler. The condition of the
pipes and process itself can often be monitored with an infrared camera. Buildup of product
debris in a pipe will usually show up as a temperature differential in a section of pipe. After the
buildup has been removed, Infrared Thermal Imaging can be used to verify that the work hasbeen completed satisfactorily.
7/30/2019 Infrared thermographic system
33/40
Fig 11.7 IR image of blower pipe
Product buildup can be clearly seen as the cold area
on the bottom of the pipe.
11.5 OTHER APPLICATIONS
11.5.1 Automobile industries
Infrared thermometers are used extensively in the automotive industry to diagnose problems
ranging from air conditioning, brakes, to engines. They also help in avoiding dangerous car
interiors by convenient temperature measurement with these non-contact devices. They are
however most effective in diagnosing temperature-related engine problems. This is because, as
with other traditional thermometers, the user doesn't have to dissemble the whole engine, as it
reaches even inaccessible areas. Among the various uses of these infrared thermometers in
engine and exhaust troubleshooting are for scanning manifold temperature to determine low
compression, for misfire condition, measuring and comparing exhaust system components for
correct fuel/air mixture and for scanning both sides of the catalytic converter for temperature
differences
These are also used for cooling system diagnostics like checking for overheating problems,
scanning radiators for core restrictions, measuring thermostat temperature and above all for
measuring coolant temperature sensors and manifold air temperature sensors
7/30/2019 Infrared thermographic system
34/40
Even for measuring climate control, in automobiles infrared thermometers are used most of the
times. With them you can check heaters, air conditioners, and vents at a convenient pace for any
kind of malfunction or system output. These are equally powerful like digital multimeters, as
gauging instruments.
Further, infrared thermometers are used for checking the condition of braking system in
automobiles. This is very necessary because if the temperature is significantly higher than
ambient or varied temperatures of rotors, drums or bearings, it would indicate excessive wear.
Uneven braking can also be diagnosed with this amazing instrument.
11.5.2 Steel industry
Steel industry use thermometer because products are moving, the temperature is very high.
Ordinary steel industry application is temperature is a constant state of molten steel is beginning
to change into pieces. With the same temperature to heating steel is preventing it from the
deformation of the key, infrared thermometeris used to measure the internal temperature of the
regenerator. In high temperature spin rolling grinding machine, the infrared thermometer was
used to identify of product temperature is in rotating limits. In cooling grinding machine, infrared
thermometer rolling in steel cooling process monitoring steel temperature.
11.5.3 Glass industry
In glass industry, products are in the dynamic state, which is to be heated to a high temperature.
Infrared thermometer used to monitor the temperature of furnace. Portable sensors are used to
detect by measuring the external temperature points. Measurement of the temperature during
melting of glass is used to determine proper mouth furnace temperature. On the flat glass,
sensors in each processing phases are used for testing temperature. Wrong temperature or
excessive temperature change can cause uneven expansion or contraction. For bottles and
container products, it would undergo melt flow to keep the glass at the same temperature before
furnace. Infrared thermometer is used to detect the glass before furnace temperature. So it in
export place should be the proper state. In fiberglass products, infrared sensor is used in
http://www.temperature-controller.info/categories.php?id=6http://www.temperature-controller.info/categories.php?id=67/30/2019 Infrared thermographic system
35/40
processing furnace detection of glass furnace temperature before. Infrared sensor in glass
industry another use is used in windscreen products process.
11.5.4 Plastic industry
In the plastic industry, infrared thermometer is used to avoid defiled product, by measuring
temperature profiles of dynamic objects. In blown film ejective process, temperature
measurements can be successfully performed with ease using an infrared imager to adjust
heating and cooling which can help to keep plastic tension completely distributed along its
thickness. Also in the case of film made in cast out process, sensors help control temperature to a
large extent. In chip pressure out, the sensor can let operator to adjust extinguished heater and
cold roll to guarantee the quality of its products. Infrared thermometer in preventive
maintenance, uses portable heat display system, maintain personnel can identify potential or
already existing problems. For example: the engine overheat, transformer winding of plugged
cooling fins, capacitance contact undesirable, heat in a compressor cylinder lid rally. Any
problems are accompanied with temperature, or temperature curve with surrounding temperature
completely not, so can use portable heat display system positioning. In most cases, when asked
to stop process before, can be timely find out problems, and timely correcting.
11.5.5 Chemical industry
In petrochemical industry, refineries in routine preventive maintenance program, uses
temperature display system. These programs include furnace process monitoring and several
confirmations. In furnace processes, infrared heating tube displays are used to detect rally carbon
ratio. These are called coking rally, which may lead to a melting pot of higher DianHuoLv. The
high temperature condition will reduce the life of the pipes used. This condition can be
controlled to a large extent by incorporating infrared thermometer detectors in the vulnerable
sites.
There are many more instances besides those mentioned previously for which thermography can
be utilized. Here are a few:
11.5.6 Aerospace Applications
7/30/2019 Infrared thermographic system
36/40
Water ingress in airplane control surfaces and radomes Tire and brake system diagnosis Windshield and wing surface deicing system diagnosis Stress crack and corrosion identification and location Jet and rocket engine analysis Composite materials delamination and disbanding location Target signature analysis
11.5.7 Petrochemical Applications
Refinery process line insulation loss or leak detection Refinery process evaluation Heat exchanger quality and efficiency evaluation Furnace refractory (insulation) inspections Furnace internal flame evaluation and tube inspections Flame propagation explosion analysis
11.5.8 Research and Development Applications
Design prototyping evaluation
11.5.9 Pulp and Paper
Detect uneven heat distribution in Fourdrinier steam boxes Identify wet streaks, nonuniformity that can have adverse effects on paper quality Identify basis weight variations Monitor size press performance Analyze dryer temperatures to look for nonuniformity in dryers Monitor coating to see that it is being applied uniformly to surface of the paper Analyze reel to find anomalies that may be induced by pieces of process equipment
connected to the paper machine
Inspect chip piles for hot spots
11.5.10 Mechanical Systems
7/30/2019 Infrared thermographic system
37/40
Boilers Inspect burners for flame impingement and burner management Look at combustion patterns of fuel Detect thermal patterns on boiler tubes and measure tube skin temperature during normal
operation or when boiler is on standby
Scan and record temperatures in areas of boiler not monitored Scan the exterior of boiler for refectory damage or locate warmer areas where potential
refectory damage may occur
Detect coke buildup in crude oil furnaces Power plant boiler flue gas leak detection Mechanical bearing inspections Heat, ventilation, and air-conditioning equipment evaluation Cold storage cooling losses Detect insulation leaks in refrigeration equipment
12.0 CONCLUSION
This seminar provides a summary of infrared thermographic systems. The theory of operation,
which is based on measuring blackbody thermal radiation, and the fourth power temperature
dependence of emitted IR energy, demonstrates the strong signal inherent to this sensing
technology and hence, the high temperature resolution that is achievable. There are various types
of IR imaging systems. All of them generate images that represent the surface temperatures of an
object, but they can be comprised of a variety of detector materials, each with unique spectral-
physical properties, which makes it important to select the proper detector technology for a
particular application. There are two major families of optical design, focal plane array imagers
and motorized scanning mirror based imagers. For successful IR imaging, it is essential to be
aware of the surface property emittance. Knowledge of surface emittance, in the spectral band of
the imager being used, allows the thermographer to distinguish the emitted portion of the
measured radiation from the reflected portion. The thermal setup and environment also require
special considerations for successful thermography. The thermographer often manipulates the
7/30/2019 Infrared thermographic system
38/40
overall heat transfer situation that leads to the temperature differences imaged on the specimen of
interest in order to produce the most accurate and informative thermal data. Scientific
temperature mapping is a methodology that improves upon the absolute accuracy of quantitative
thermography. The procedures employed include external referencing targets and background
mirrors. Typical applications of IR imaging include: thermographic inspection for predictive
maintenance, medical imaging, non-destructive materials testing, and building component
testing.
13.0 Future of IR imaging
The future of IR imaging will likely see many more applications emerge, as this powerful
technology becomes more accessible with less expensive and more compact equipment. New
detector types such as microbolometers, QWIPS or direct sensing optical systems (change of
refraction due to temperature) will become more prominent. IR imagers will be substantially
smaller and more portable with reduced power requirements, as a result of compact focal plane
array optics and not being burdened by providing cryogenic cooling for sensors. Increasing
computing power will make image analysis and processing possible for online usage. Image
resolution of focal plane arrays is expected to rise. Mega-pixel arrays will likely be available for
thermal imaging. Faster image acquisition speeds will open a new world of diagnostic
possibilities for very fast thermal phenomena such as combustion or blasting technology. The
various detection mechanisms may make IR imagers even more specialized for their intended
application. Selecting the appropriate technology for the job will continue to be important. For
instance, an imager with a very high frame rate may lack the ability to make absolute
temperature measurements as accurately as an imager designed for slower phenomenon, where
absolute accuracy is most crucial. Overall, there is much to be learned by seeing temperatures
7/30/2019 Infrared thermographic system
39/40
with an IR imager, and this capability is likely to grow more powerful, and become more
accessible, in the future.
14.0 References
Carlomagno, G. M., Heat Transfer Measurements by Means of Infrared Thermography,In Measurement Techniques, von Karman Institute, Lect. Series 2005-09, pp. 1-114,
Rhode-Saint-Gense, Belgium, 2009
The Encyclopedia of Imaging Science and Technology by Joseph P. Hornak, Editor-in-Chief, John Wiley and Sons.
De Luca, L. and Cardone, G., MTF Cascade Model for a Sampled IR Imaging System,Applied Optics, vol. 30, pp. 1659-1664.
H. Kaplan, Practical Applications of Infrared Thermal Sensing and Imaging Equipment,Second Edition, Proc. Soc. of Photo-Opt. Instrumentation Eng. (SPIE), TT34, 160, 2003.
D. Turler, B.T. Griffith, D. Arasteh. Laboratory procedures for using infraredthermography to validate heat transfer models. Insulation materials: Testing and
Applications: Third Volume ASTM STP 1320. R. S. Graves and R. R. Zarr, ed.
Philadephia, PA, American Society for Testing and Materials, 2001
B.T. Griffith, H. Goudey, D. Arasteh, Infrared Thermography Measurements ofWindow Thermal Test Specimen Surface TemperaturesASHRAE Transactions ?(not yet
published) American Society of Heating, Refrigeration and Air-Conditioning Engineers
Inc., 2002
V. Vavilov, X. Maldague, J. Picard, R.L. Thomas, L.D. Favro, Dynamic thermaltomography: New NDE technique to reconstruct inner solids structure by using multiple
7/30/2019 Infrared thermographic system
40/40
IR image processing, Review of Progress in Quantitative NDE, D.O. Thompson and
D.E. Chimenti ed., Brunswick, Maine, 1991, 11A, Plenum Press, 1999, pp. 425-432
X. Maldague, P.O. Moore, Infrared and Thermal Testing. American Society for Non-destructive Testing, 3
rdEd. Columbus Ohio, 2006
Internet:http://www.infrared institute.com
http://www.sensortips.com/2009/09/14/understanding-infrared-thermometry
http://www.ces-world.com/InfraredTech/mechanical1.html
http://www.eutechinst.com/index.html
http://www.sensortips.com/2009/09/14/understanding-infrared-thermometry/http://www.ces-world.com/InfraredTech/mechanical1.htmlhttp://www.ces-world.com/InfraredTech/mechanical1.htmlhttp://www.eutechinst.com/index.htmlhttp://www.eutechinst.com/index.htmlhttp://www.eutechinst.com/index.htmlhttp://www.ces-world.com/InfraredTech/mechanical1.htmlhttp://www.sensortips.com/2009/09/14/understanding-infrared-thermometry/Top Related