IMPORTATION OF IRON & STEEL AND METAL
PRODUCTSUPDATES ON PROCEDURES AND LATEST DEVELOPMENT
PRESENTATION OUTLINE
INTRODUCTION
LIST OF TARIFF CODES:
a) 187 Tariff Codesb) New Mandatory Standards for Aluminium Sheet and Foil
FLOWCHART – CONSIGNMENT METHODS
CONSIGNMENT VERIFICATION AND SAMPLING
DIFFERENT CHANGES BETWEEN CURRENT AND FUTURE COA ONLINE SYSTEM
OUR TESTING EQUIPMENT AND FACILITIES
SIRIM QAS INTL. SDN. BHD. – BRANCHES OFFICES AND FACILITIES
COA COSTING
CONTACTS AND PERSON-IN-CHARGE
STATISTIC NO. OF APPLICATIONBy Product Type – Shah Alam
STATISTIC NO. OF APPLICATION (JAN - JUNE 2011)By Port of Entry / Locations – SIRIM Shah Alam
STATISTIC NO. OF APPLICATION (JAN - JUNE 2011)By Port of Entry / Locations – SIRIM Penang
STATISTIC NO. OF APPLICATION (JAN - JUNE 2011)By Port of Entry / Locations – SIRIM Johor
STATISTIC NO. OF APPLICATION (JAN - JUNE 2011)By Port of Entry – SIRIM Sarawak
STATISTIC NO. OF APPLICATION (JAN - JUNE 2011)By Port of Entry – SIRIM Sabah
LIST OF TARIFF CODES : 187 TARIFF CODES
NEW MANDATORY STANDARDS FOR ALUMINIUM SHEET AND FOIL
FLOWCHART – CONSIGNMENT METHODS
CONSIGNMENT VERIFICATION AND SAMPLING
CONSIGNMENT VERIFICATION AND SAMPLING
Container Stationed at Inspection Bay
CONSIGNMENT VERIFICATION AND SAMPLING (cont.)
Products Stationed at Inspection Bay
CONSIGNMENT VERIFICATION AND SAMPLING (cont.)
Products Stationed at Factory
CONSIGNMENT VERIFICATION AND SAMPLING (cont.)
Sampling and Cutting Small Samples
CONSIGNMENT VERIFICATION AND SAMPLING (cont.)
Verification Process
CONSIGNMENT VERIFICATION AND SAMPLING (cont.)
Verification Process (Measurement)
CONSIGNMENT VERIFICATION AND SAMPLING (cont.)
Sampling and Cutting Big Samples
CONSIGNMENT VERIFICATION AND SAMPLING (cont.)
Sampling and Cutting Big
Samples
CONSIGNMENT VERIFICATION AND SAMPLING (cont.)
Sampling and Cutting Big
Samples (at Factory)
CONSIGNMENT VERIFICATION AND SAMPLING (cont.)
VERIFICATION AND SAMPLING REPORT
PORT TRACKING SYSTEM - WEST PORT & NORTH PORT
PORT TRACKING SYSTEM (West Port)
BLOCK
PORT TRACKING SYSTEM (North Port)
YES
DIFFERENT CHANGES BETWEEN CURRENT AND
FUTURE COA ONLINE SYSTEM
Details Current COA Online System
Future COA Online System
Issuance of Quotation
Manually issued to Client (sent thru fax).
Thru online – Client can view and print out the Quotation in online system.
Details Current COA Online System
Future COA Online System
Payment Process
Client can make payment:
a)At One-Stop-Centre (Building 25) OR
b)Thru Bank/EFT/TT (Client need to fax a copy of bank-in slip, cheque and receipt to SIRIM for confirmation).
Client can make online payment.
Details Current COA Online System
Future COA Online System
Schedule Planning
Client can call SIRIM’s Scheduler to arrange verification and sampling OR Scheduler will call Client to propose date and time for verification activity.
SIRIM’s Scheduler will view COA Application, confirms ETA and enters proposed date and time for verification activity into system.
Client can choose to accept or decline proposed date.
If Client decline: Client must provide new proposed date.
Upon confirmation of schedule date, Scheduler will arrange SIRIM’s Officer to do the verification activity.
Details Current COA Online System
Future COA Online System
COA Certificate
Client is not able to print out the COA Certificate. COA Certificate will be courier to Client.
The online system will allow Client to print out the COA Certificate.
Details Current COA Online System
Future COA Online System
Issuance of Test Report
SIRIM will courier the hardcopy of Test Report to Client.
The online system will allow Client to print out the Test Report.
Details Current COA Online System
Future COA Online System
Cut-off Date No cut-off date available. Application only can be made within 3 months before ETA;
Once quotation issued, the cut off period will be 1 month after the issuance of quotation;
Once payment made, the cut off period will be 2 weeks after payment received.
Details Future COA Online System
Combined Verification 2 applications of same type; Limit to 5000 MT; Shipment within 7 days interval.
OUR TESTING EQUIPMENT AND FACILITIES
• Tensile • Shear Strength• Pull Out Test• Slip Test• Fatigue Test• Compression
Tensile Testing
Involves straining a test piece in tension, generally tofracture for the purpose of determining mechanicalproperties.
Tensile Testing
Involves straining a test piece in tension, generally tofracture for the purpose of determining mechanicalproperties.
MECHANICAL TESTMECHANICAL TEST
Servo Hydraulic Universal Testing Machine
Servo Hydraulic Universal Testing Machine
Dynamics Machine 1000 kN Dynamics Machine 1000 kN
Instron 200kNInstron 200kN
MECHANICAL TESTMECHANICAL TEST
Hardness Testing
Hardness is the resistance to plastic deformation.Determined by the ability of a materialto scratch another, diamond being thehardest and talc the softer.
Hardness Testing
Hardness is the resistance to plastic deformation.Determined by the ability of a materialto scratch another, diamond being thehardest and talc the softer.
- Major loads for the Standard Rockwell test are 60, 100, and 150 kg
- HRA, HRB and HRC
- According to ASTM E 18/ ASTM A 370
- Major loads for the Standard Rockwell test are 60, 100, and 150 kg
- HRA, HRB and HRC
- According to ASTM E 18/ ASTM A 370
MICRO HARDNESS
Load range divide into two:
- Micro = 1 to 1000 grams
- Macro = above 1000 grams
Load range divide into two:
- Micro = 1 to 1000 grams
- Macro = above 1000 gramsROCKWELL
Load : Up to 3000 kg
Ball Indentor : 5 & 10 mm
Load : Up to 3000 kg
Ball Indentor : 5 & 10 mm
BRINELL
Charpy Impact Testing
MECHANICAL TESTMECHANICAL TEST
Capacity:
• Up to 300 J
• In House specimen preparation
• According to BS 131 / ASTM A 370 / BS EN 10045-1/ AS 1544.2
Capacity:
• Up to 300 J
• In House specimen preparation
• According to BS 131 / ASTM A 370 / BS EN 10045-1/ AS 1544.2
CHARPY TEST SPECIMEN
CHEMICAL COMPOSITIONCHEMICAL COMPOSITIONTESTING EQUIPMENTTESTING EQUIPMENT
SPECTROMETER SHIMADZU PDA-7000
PORTABLE XRF (ALPHA)
PORTABLE XRF (DELTA)
WAVELENGTH DISPERSIVE X-RAY FLUORESCENCE
SPECTROMETER
Elements analyzed:
• Carbon, Silicon, Manganese, Phosphorus, Sulphur, Nickel, Chromium
• Total Elements : 32 Elements
Elements analyzed:
• Carbon, Silicon, Manganese, Phosphorus, Sulphur, Nickel, Chromium
• Total Elements : 32 Elements
COATING MASS TESTCOATING MASS TEST
TEST SAMPLE WEIGHING TEST SAMPLE EXTRACT COATING MATERIAL
COATING MATERIAL EXTRACTED
WEIGHING TEST SAMPLE AFTER EXTRACTION OF COATING MATERIAL
TYPICAL PRODUCT & TENSILE TEST SPECIMEN PREPARATION
CHANNEL ANGLE I-BEAM PIPE SHEET COIL
RECTANGULAR TEST SPECIMEN -
BEFORE TEST
CIRCULAR TEST SPECIMEN -
BEFORE TEST
RECTANGULAR TEST SPECIMEN
- AFTER TEST
CIRCULAR TEST SPECIMEN - AFTER TEST
TYPICAL PRODUCT (cont.) & TEST
MANHOLE COVER & FRAME
LOAD TEST
BREAKING LOAD TEST OF WIRE ROPE
WIRE ROPE
BREAKING LOAD TESTPC STRAND
SIRIM QAS INTERNATIONAL SDN. BHD.- BRANCHES OFFICES
AND FACILITIES
FRONT OFFICE SQAS FRONT COUNTER
SPECTROMETER SHIMADZU PDA-7000
XRF ANALYZERXRF ANALYZER
UTM 1000kN
SIRIM PENANG
FRONT OFFICE
MAIN ENTRANCE
SPECTROMETER SHIMADZU PDA-7000
XRF ANALYZERXRF ANALYZER
UTM 1000kN
SIRIM JOHOR
SPECTROMETER SHIMADZU PDA-7000
UTM 1000kN
XRF ANALYZER
UTM 200kN
FRONT OFFICE
SQAS FRONT COUNTER
SIRIM SARAWAK
FRONT OFFICE
SPECTROMETER SHIMADZU PDA-7000
XRF ANALYZERXRF ANALYZER UTM 1000kN
MAIN ENTRANCE
SIRIM SABAH
COA COSTING
SIRIM QAS implemented COA since Nov 2008 with 57
tariff lines made Mandatory
COA application was processed and approved only from Shah Alam office
Initial Costing:-
Application/Processing Fee : RM 500 Verification Fee : RM 2000 – RM 2500 Testing Fees : Varies, depending on product standards
BACKGROUND OF COA COSTING
First Review : 2009 (Announced through letter to MITI, signed by SGM, SIRIM QAS)
Verification Fee has been capped to RM 2000
Second Review : 2009 (Announced by SIRIM QAS MD, during briefing to Deputy Minister MITI, and agreed by MITI, MISIF and FMM)
Application Fee has been substantially reduced from RM500 to RM150.
Verification Fee standardized at RM1000, since SIRIM QAS started its COA activities at branches : Penang, Johor, Sabah and Sarawak.
Sampling Plan : Increased from 1 sample for every 100MT to 1 sample for every 250MT.
BACKGROUND OF COA COSTING (cont.)
FIXED FEE Application : RM150 Verification : RM1000* * This fee represent a compromised figure that reflects a balance fee for all operations throughout Malaysia (Shah Alam, Johor, Penang, Pahang, Sabah & Sarawak)
VARIABLE FEE Testing (based on Sampling Plan) Testing based on different product standards
ELEMENTS OF COA FEE
FOR VOLUME
EXCEEDS
5000 MT
5 % DISCOUNT
ON TESTING
FEES
GOOD NEWS – FURTHER DISCOUNT
EFFECTIVE DATE FOR NEW DISCOUNT:
13th OCTOBER 2011
CONTACTS & PERSON-IN-CHARGE
CONTACTS
SIRIM Shah Alam
Address Building 22SIRIM QAS International Sdn. Bhd.No.1, Persiaran Dato’ Menteri40700 Shah AlamSelangor Darul Ehsan
Tel. No. 03 – 5544 5852 (Pn. Raja Nor Siha Raja Abd Hanan – Section Head)
03 – 5544 5878 (Pn. Seri Banun Sujangi – Group Leader)
03 – 5544 5874 (En. Dalha Rahmat – Group Leader)
03 – 5544 5867 (En. Faiz Mohd Yusuf – Senior Technical Executive)
Fax No. 03 – 5544 5186 / 5855 / 5886
CONTACTS (cont.)
SIRIM Shah Alam(Enquiry & Quotation)
Tel. No. 03 – 5544 5184 (Pn. Zaryatul Akma)
03 – 5544 5032 (En. Sakuwan)
03 – 5544 5182 (Cik Liana)
03 – 5544 5031 (En. Shukri)
03 – 5544 5183 (En. Farizzul)
Fax No. 03 – 5544 5186
03 – 5544 5855
SIRIM Shah Alam(Schedule for Verification &
Inspection)
Tel. No. 03 – 5544 5187 (Pn. Sabrina)
03 – 5544 5033 (Pn. Hayati)
Fax No. 03 – 5544 5186
03 – 5544 5855
CONTACTS (cont.)
SIRIM Shah Alam(Testing)
Tel. No. 03 – 5544 5880 (En. Fahim)
03 – 5544 5180 (En. Azlan)
03 – 5544 5880 (En. Waheedir)
Fax No. 03 – 5544 5186
03 – 5544 5855
SIRIM Shah Alam(Verification & Inspection)
West Port P.I.C. : En. Zaimar
Tel. No. : 03 – 3101 1455/1457
Fax No. : 03 – 3101 1453
North Port P.I.C. : En. Mohd Dasuki
Tel. No. : 03 – 3176 1431/1435
Fax No. : 03 – 3176 1439
CONTACTS (cont.)
SIRIM Johor
Address No. 3, Jalan Teknologi 5Taman Teknoloogi Johor81400 SenaiJohor Darul Takzim
Tel. No. 07 – 599 8364
07 – 599 8367
Fax No. 07 – 598 7059
P.I.C Tn. Hj. Ahmad Rumizi Jasmin
En. Mohd Helmi Kamdari
En. Mohd Ridha Noraship
En. Shaiful Hisam Samat
Pn. Zuraidah Padil
SIRIM Penang
Address 483, Mukim 6Jalan Permatang Pauh13500 Permatang PauhSeberang PraiPulau Pinang
Tel. No. 04 – 537 7435
04 – 538 4260
Fax No. 04 – 538 4261
P.I.C En. Mohamad Zakaria
En. Mohd Fairuz Ismail
En. Mohd Haniff Abu Hassan
En. Mohd Faisol Morat
En. Saiful Nazri Ramlee
CONTACTS (cont.)
SIRIM Sarawak
Address Lot 802Taman Perindustrian Demak LautJalan Bako, Peti Surat 329293764 KuchingSarawak
Tel. No. 082 – 439 052
082 – 439 054
Fax No. 082 – 439 060
P.I.C En. Kasvenda Kasim
En. John Melvin a/k Peter
Pn. Norida Bujang
SIRIM Sabah
Address Lot 1, No. 6 Jalan 1KKIP Timur Commercial Zone 2Kota Kinabalu Industrial Park88460 Sabah
Tel. No. 088 – 497 048
088 – 497 082
Fax No. 088 – 496 357
P.I.C Pn. Reena Rahman
En. Bonaventure @ Hamzah Abie
En. Andy Azman Lantara
PROCEDURES AND UPDATES
http://www.sirim-qas.com.my
THANK YOU FOR YOUR ATTENTION
THANK YOU FOR YOUR ATTENTION
Top Related