IMPLEMENTING SYNCHRONOUS MODELS ON LOOSELY TIME TRIGGERED ARCHITECTURES
Discussed by Alberto Puggelli
OUTLINE From synchronous to LTTA Analysis of system throughput
SYNCHRONOUS IS GOOD… Predictability Theoretical backing Easy verification Automated synthesis …..
… BUT DIFFICULT TO IMPLEMENT! Need for clock synchronization in embedded
systems Long wires Cheap hardware Timing constraints
SOLUTION Complete all verification steps in the
synchronous domain De-synchronize the system while preserving
the semantic Stream Equivalence Preservation
STEPS TO DESYNCHRONIZE Design the system with sync semantic Choose a suitable architecture Platform Based Design: select a set of
intermediate layers to map the system description on the architecture while preserving the semantic
ARCHITECTURE: LTTA Loosely Time Triggered Architecture Each node has an independent clock and it
can write and read to the medium asynchronously
The medium is a shared memory, that is refreshed synchronously to the medium clock
Neither blocking read nor blocking write Each node has to check for the presence of data
in the medium (reading) and for the availability of memory (writing)
INTERMEDIATE LAYER: FFP Kahn Process Network with bounded FIFOs
(to represent a real system) Marked Directed Graphs (MDG) to allow
semantic preservation and to analyze system performance
SYNCHRONOUS MODEL Set of Mealy machines and connections among
them directed graph (nodes & edges) Every loop is broken by a unit-delay element (UD) Partial order: Mi < Mj if there is a link from Mi to Mj
without UD (reflexive and transitive) Minimal element: Mi if there is no Mj s.t. Mj < Mi Each link is an infinite stream of values in V (also UD
has output streams) Each machine produce an output and a next state
as a function of the inputs and of the current state For UD y(k+1) = x(k) y(0) = i.v. (x input, y output) Firing the machines in any total order that respects
the partial order
EXAMPLE
ARCHITECTURE: LTTA Each node runs a single process triggered by
a local clock. Communication by Sampling (CbS) links
among nodes. API: set of functions to call CbS. These
functions can be run at certain conditions (assumption) and they guarantee certain functionalities.
The execution time of each block is less than the time between 2 triggers.
ARCHITECTURE: CBS Only source nodes can write (fun: write()) Only destination nodes can read (fun: read()) Unknown execution time Atomicity is guaranteed (a function ends
before the following one starts) No guarantee in freshness of data (due to
execution time) Fun isNew: returns true if there are fresh data
Write add an index (sn) to the data; Reader keeps the index (lsn) of the last read data: if lsn = sn the data is old.
EXAMPLE
INTERMEDIATE LAYER: FFP Architectural similarities with LTTA and
semantics close to synchronous Set of sequential processes communicating
with finite FIFOs. Processes do NOT block: process has to
check whether they can execute (queue is not empty before reading; queue is not full before writing)
isEmpty; isFull; put; get (API similar to CbS)
MAPPING SYNC TO FFP Each machine is mapped into a process (UD
are not) There is a queue for each link
If the link has a UD the queue is size 2 If the link has no UD the queue size is 1
At each trigger IF (all input queues are non-empty and all output queues
are non-full) Compute outputs and new state Write outputs to output queues
Else Skip step
End if
MAPPING SYNC TO FFP (2) Conversion into a Mark Directed Graph
Every process becomes a transition Every queue is converted in a forward (model non-
empty queues) and in a backward place (model non-full queues)
If the queue has k places and it has(not) a UD, I put k-1(k) tokens in the backward place and 1(0) in the forward place
EXAMPLE
EXAMPLE
AFTER FIRING T1
EXAMPLE
AFTER FIRING T3
EXAMPLE
AFTER FIRING T2
MAPPING SYNC TO FFP Theorem: semantic is preserved with queues
of size at most 2. Queue of size 2 if there is a UD; size 1 if there is
not. Step 1: the FFP has no deadlocks (this is true by
construction since I put at least one token in each directed circuit)
Step 2: any execution of MDG is one possible execution of the corresponding FFP.
Note: check for isFull is not necessary, because by construction, if inputs are not empty, outputs can’t be full.
MAPPING FFP TO LTTA It is possible to map 1:1 from FFP to LTTA
FFP API can be implemented on top of LTTA API Semantic is preserved by skipping processes
that can’t be fired (either for empty inputs or for full outputs)
THROUGHPUT ANALYSIS Need for an estimation of the system
throughput (λ): each process either runs or skips for every trigger.
Upper bound: clock rate (if globally sync) Is there a lower bound (worst case)?
THROUGHPUT ANALYSIS In RT: Theorem: if the size of a queue is increased,
the resulting throughput either increases or remains equal or larger.
Need for a symbolical definition of throughput that is independent of the implementation logical-time throughput
In LT: The worst-case throughput is
THROUGHPUT ANALYSIS To find the minimum we define a “slow
triggering policy”: at each time step, the clock of each process ticks one and only one time and the clocks of disabled processes tick before the clocks of enabled processes
Theorem: the throughput of a system that “adopts” the slow triggering policy is the lowest possible All disabled processes can’t run until the
following time step the throughput is minimized
THROUGHPUT ANALYSIS To evaluate the value of λmin we first analyze
the associated MDG. Create a reachability graph (RG) that implements
the slow triggering policy it is a graph in which all enabled transitions are fired (i.e. all transitions that are not enabled can’t be fired until the following step)
Determine the lasso starting from M0 Lasso: a loop in the (RG) that the system travels an
infinite number of times (remember: deadlock free)
THROUGHPUT ANALYSIS If L is the length of the lasso, for the process
P:
The WC throughput is the same for all processes (a lasso is periodic, so all transitions have to be fired the same number of times to return to the starting marking)
If Δ is the period of the slowest clock:
EXAMPLE
Initial Marking: M0 = (0,1,0,1) #transitions = 3 #places = 2(3-1) = 4Two adjacent processes can’t be enabled at the same time step! The lasso is (0,1,0,1) (1,0,0,1) (0,1,1,0) (1,0,0,1)The lasso has length 2 and each transition is fired once throughput = 0.5
EXAMPLE
EXAMPLE
EXAMPLE
EXAMPLE 2
Initial Marking: M0 = (0,2,0,2) #transitions = 3 #places = 2(3-1) = 4The lasso is (0,2,0,2) (1,1,1,1) (1,1,1,1)The lasso has length 1 and each transition is fired once throughput = 1
EXAMPLE 2