Download - How to Connect a DSS V6 to another DSS V6 with an iSCSI Target Volume

Transcript
Page 1: How to Connect a DSS V6 to another DSS V6 with an iSCSI Target Volume

Software Version: DSS ver. 6.00 up13

Presentation updated: September 2010

How to Connect a DSS V6 to another DSS V6

with an iSCSI Target Volume

Page 2: How to Connect a DSS V6 to another DSS V6 with an iSCSI Target Volume

2www.open-e.com

1. Hardware configuration2. Configure Destination Node:

• Create a Volume Group, iSCSI volume and target on the DSS2,

3. Connecting iSCSI target Volume using iSCSI Initiator on DSS1• Connect to iSCSI target Volume from DSS2 using iSCSI Initiator on DSS1• Create a Volume Groups (vg01), on DSS1

TO SET UP A BACKUP USING AN ISCSI TARGET VOLUME OVER A LAN, BETWEEN TWO DSS V6 SYSTEMS, PERFORM THE FOLLOWING STEPS:

How to Connect to an iSCSI Target Volume over a LAN

Page 3: How to Connect a DSS V6 to another DSS V6 with an iSCSI Target Volume

3www.open-e.com

Volume Group (vg00) Volume Group (vg00)

ISCSI volume (lv0000)

iSCSI Target: Target0

Data Server (DSS1)Source nodeIP Address:192.168.0.220

iSCSI initiator

RAID System 1 RAID System 2

Data Server (DSS2)Destination nodeAddress IP:192.168.0.240

1. Hardware configuration

Volume Group (vg01)

NAS volume (lv0100)

iSCSI Target Volume

How to Connect to an iSCSI Target Volume over a LAN

Page 4: How to Connect a DSS V6 to another DSS V6 with an iSCSI Target Volume

4www.open-e.com

2. Configure Destination Node

Volume Groups (vg00)

In Unit manager add the selected physical units (Unit MD0 or other) to create a new volume group (in this case, vg00) and click apply button.

Under the “CONFIGURATION”tab, select „volume manager” and next Vol. Groups.

How to Connect to an iSCSI Target Volume over a LANData Server (DSS2)Destination nodeIP Address: 192.168.0.240

Page 5: How to Connect a DSS V6 to another DSS V6 with an iSCSI Target Volume

5www.open-e.com

2. … Continue

Select the appropriate volume group (vg00) from the list on the left. In the Action fieldselect a new iSCSI volume for the required size.

After assigning an appropriate amount of space for the iSCSIvolume, click the apply button.

Now select the required size of iSCSI volume. In this examplewe will be adding 450 GB for the iSCSI volume.

How to Connect to an iSCSI Target Volume over a LANData Server (DSS2)Destination nodeIP Address: 192.168.0.240

Page 6: How to Connect a DSS V6 to another DSS V6 with an iSCSI Target Volume

6www.open-e.com

The destination iSCSI VolumeBlock I/O is now configured.

iSCSI volume (lv0000)

Data Server (DSS2)Destination nodeIP Address: 192.168.0.240

2. … Continue

How to Connect to an iSCSI Target Volume over a LAN

Page 7: How to Connect a DSS V6 to another DSS V6 with an iSCSI Target Volume

7www.open-e.com

Data Server (DSS2)Destination nodeIP Address: 192.168.0.240

Choose “CONFIGURATION”,„iSCSI target manager” and “Targets” from the menu

iSCSI targets

In the Create new target, click the apply to confirm.

2. … Continue

How to Connect to an iSCSI Target Volume over a LAN

Page 8: How to Connect a DSS V6 to another DSS V6 with an iSCSI Target Volume

8www.open-e.com

Select target0 within the Targets field.

Assign a volume to the target, click the button located under Action.

Data Server (DSS2)Destination nodeIP Address: 192.168.0.240

iSCSI targets

2. … Continue

How to Connect to an iSCSI Target Volume over a LAN

Page 9: How to Connect a DSS V6 to another DSS V6 with an iSCSI Target Volume

9www.open-e.com

Data Server (DSS2)Destination nodeIP Address: 192.168.0.240

The destination iSCSI target is now configured.

iSCSI targets (target0)

2. … Continue

How to Connect to an iSCSI Target Volume over a LAN

Page 10: How to Connect a DSS V6 to another DSS V6 with an iSCSI Target Volume

10www.open-e.com

iSCSI initiators

Choose “SETUP”, “iSCSI initiators”. In Add new portal server, in field Portal IP enter the IP Address of targets on thedestination node (in our example this would be 192.168.0.240) then click on the apply to confirm.

Data Server (DSS1)Source nodeIP Address: 192.168.0.220

3. Connecting the iSCSI target Volume using iSCSI Initiator

How to Connect to an iSCSI Target Volume over a LAN

Page 11: How to Connect a DSS V6 to another DSS V6 with an iSCSI Target Volume

11www.open-e.com

Data Server (DSS1)Source nodeIP Address: 192.168.0.220

iSCSI initiators

In Portal manager select the name of the iSCSI targets and click the connect button.

Select 192.168.0.240 within the Portals field.

3. … Continue

How to Connect to an iSCSI Target Volume over a LAN

Page 12: How to Connect a DSS V6 to another DSS V6 with an iSCSI Target Volume

12www.open-e.com

Data Server (DSS1)Source nodeIP Address: 192.168.0.220

iSCSI initiators

iSCSI target:iqn.2009-12:dss2.target0 has been connected successfully.

3. … Continue

How to Connect to an iSCSI Target Volume over a LAN

Page 13: How to Connect a DSS V6 to another DSS V6 with an iSCSI Target Volume

13www.open-e.com

Data Server (DSS1)Source nodeIP Address: 192.168.0.220

iSCSI initiators

Next, click on the iSCSI target name within the Portals, in this example the name is:iqn.2009-12:dss2.target0.

In the Target manager you can view the connected target's name as well as its size.

3. … Continue

How to Connect to an iSCSI Target Volume over a LAN

Page 14: How to Connect a DSS V6 to another DSS V6 with an iSCSI Target Volume

14www.open-e.com

Data Server (DSS1)Source nodeIP Address: 192.168.0.220

Volume Groups (vg00)

Under the „CONFIGURATION”tab, select “volume manager” and next Vol. Groups.

The configuration of connecting toan iSCSI target Volume

is now complete.

In the Unit manager selectphysical units (Unit S003) to create a new volume group (in this case, vg01) and clickapply button

How to Connect to an iSCSI Target Volume over a LAN

3. … Continue