Lab Project
Modification of Transient Heat Conduction
Aditya Gopi CH06B001, Ajay Singh Jadun CH06B002, Anshu Gupta CH06B004
BRIEF THEORY
When solid body is subject a temperature gradient due to difference in temperature of solid
and the fluid around it transient heat conduction occurs. In the presence of the temperature
gradient heat flows between the solid and fluid till the time thermal equilibrium is reached.
When this process takes place the are two kinds of resistances, internal conductive
resistance and the external convective resistance. The ratio of these resistances is called Biot
number. Biot number (Bi) determines the validity of a body behaving as a lumped mass.
Bi= (Heat transfer by convection )(Heat transfer by conduction)
=h Lc
k
Where Lc = characteristic length (solid volume/ area)
k = thermal conductivity of the solid.
Note: If Biot number (Bi) is << 1 lumped system approximation can be done.
In order to find the heat transfer coefficient of the cylinder, we need the use of Heisler charts.
These charts have the following characteristics:
Plot of T (0,0,t ) - T∞
To - T∞
versus Fo= αt
Lc2
(Fourier Number) with reciprocal of Biot number
as a parameter. is thermal diffusivity = k/C and T(0,0,t) is temperature of the centre of the
cylinder at time t. Temperature at some location other than at the centre can be determined
from the plot of T (r,z,t ) - T∞
To - T∞
versus Fo= αt
Lc2
with 1Bi
as a parameter. (r,z are the
distances measured in the radial direction and z direction respectively from the centre.)
1
INTRODUCTION
We are modifying the current existing Transient Heat Conduction set-up from analogous to
digital. We are putting a data collector card which reads temperature and send it as a digital
data into a computer for storage. We plot this temperature data, on the Heisler chart obtained
after solving 2D transient heat conduction in a cylinder. We then obtain the Biot number,
which is used to get the convective heat transfer coefficient.
2-D Transient Heat equation is solved using CFD. The cylinder can be divided into 4
symmetric parts round its axis. It can be seen that all the four parts are symmetric and hence
we need only one quadrant for our calculation. The result can be extended to other three.
Figure 1: Division of the cylinder
2
Figure 2: Planer representation of single quadrant
Now any point (i,j) in the above quadrant can be represented as:
Figure 3: Representation of any point in the quadrant.
3
Now, centre difference formula at any point can be written as :
∂2 T∂z2 =
T ( i-1,j) -2T ( i,j )+T(i+1,j)
(dz)2
∂2 T∂z2 =
T ( i,j+1 ) -2T (i,j ) +T(i,j-1)
(dr)2
1r
∂T∂r
=T ( i,j+1 )-T(i,j-1)2r(dr)
1α
∂T∂t
=T (i-1,j )[1dz2 ]+T ( i+1,j )[1dz2 ]+T ( i,j )[-2dz2-
2
dr2 ]+T (i,j+1 )[1dr2+
12rdr ]+T(i,j-1) [1dr2
-12rdr ]
Now we can solve this differential equation with the help of boundary conditions, which are listed below.
BOUNDARY CONDITIONS
Top side node:
-k∂T∂r
=h(T- Tf )
T ( i-1,j) =T ( i+1,j ) -2h (T ( i,j ) - Tf )dz
k
Top corner (n,m):
-k∂T∂z
=h(T- Tf ) and -k∂T∂r
=h(T- Tf )
T ( i,j+1 )=T ( i,j-1) -2h (T ( i,j ) - Tf )dr
k
Right side node:
-k∂T∂r
=h(T- Tf )
T ( i,j+1 )=T ( i,j-1) -2h (T ( i,j ) - Tf )dr
k
Top side corner (1,1) :
4
-k∂T∂z
=h(T- Tf )
T ( i-1,j) =T ( i+1,j ) -2h (T ( i,j ) - Tf )dz
k
By symmetry T(i,j-1)= T(i,j+1)
Bottom corner (1,n) :
-k∂T∂r
=h(T- Tf )
T ( i,j+1 )=T ( i,j-1) -2h (T ( i,j ) - Tf )dr
k
By symmetry T(i+1,j)= T(i-1,j)
Left side node :T(i,j-1) = T(i,j+1)
Bottom side node:T(i+1,j) = T(i-1,j)
Centre node:T(i+1,j) = T(i-1,j)T(i,j+1) = T(i,j-1)
COEFFICIENT CALCULATION
Now, we convert the 2-D array into 1-D and for that we need to calculate proper coefficients for each of the temperature parameter.
Let us take an example of 3 ×3 matrix.
a11 a12 a13
a21 a22 a23
a31 a32 a33
Now, if we convert this into 1-D the matrix will be 1× 9 with the elements arranged as follows:
[a11 a12 a13 a21 a22 a23 a31 a32 a33 ]
So, following the same pattern, we can calculate the coefficient of 1-D matrix element corresponding to 2-D element. The calculation is shown below.
5
Central Node:
Coeff [n (i-1) +j, n(i-1)+(j-1) ] 1
dr2-1
2(j-1)(dr)2
Coeff [n (i-1) +j, n(i-1)+j ] -2
dz2-2
(dr)2
Coeff [n (i-1) +j, n(i-1)+(j+1)] 1
dr2+
1
2(j-1)(dr)2
Coeff [n (i-1) +j, n(i-2)+j ] 1
(dz)2
Coeff [n (i-1) +j, n(i)+j ] 1
(dz)2
Top side nodes i=1, j=2 to (n-1)
Coeff [n (i-1) +j, n (i-1)+j ] -2
(dz)2-2
(dr)2-2hk(dz)
Coeff [n (i-1) +j, n (i)+j] 2
(dz)2
Coeff [n (i-1) +j, n (i-1)+(j+1)] 1
dr2+
1
2(j)(dr)2
Coeff [n (i-1) +j, n (i-1)+(j-1)] 1
(dr)2-1
2(j)(dr)2
Coeff [n (i-1) +j, n (m-1)+(n+1) ] 2hT f
k(dz)
Left side nodes i=2 to m-1 , j=1
Coeff [n(i-1)+j, n(i-2)+j] 1
(dz)2
Coeff [n (i-1) +j, n(i)+j] 1
(dz)2
Coeff [n (i-1) +j, n(i-1)+j] -2
(dz)2-2
(dr)2
Coeff [n (i-1) +j, n(i-1)+(j+1) ] 2
(dr)2
Bottom side nodes i=m j=2 (n-1)
6
Coeff [n (i-1) +j, n (i-2)+j] 2
(dz)2
Coeff [n (i-1) +j, n(i-1)+j] -2
(dz)2-2
(dr)2
Coeff [n (i-1) +j, n(i-1)+(j+1)] 1
dr2-1
2(j-1)(dr)2
Coeff [n (i-1) +j, n(i-1)+(j-1)] 1
dr2-1
2(j-1)(dr)2
Right side i=2 (m-1) , j=n
Coeff [n (i-1) +j, n(i-2)+j] 1
(dz )2
Coeff [n (i-1) +j, n(i)+j ] 1
(dz)2
Coeff [n (i-1) +j, n(i-1)+j] -2
(dz)2-2
(dr)2-2hk [1(dr)
+12 (dr ) (n-1) ]
Coeff [n (i-1) +j, n(i-1)+(j-1)] 2
(dr)2
Coeff [n (i-1) +j, n(m-1)+(n+1)] 2hT f
k [1dr+
12 (dr ) (j-1) ]
Node (1,1)
T’(1,1)α
=T(2,1) [2(dz)2 ] + T(1,1) [-2(dz)2 -2(dr)2 -
2hk(dz) ] + T(1,2) [2(dr)2 ] + 2hT f
k(dz)
Now (1,n) (n,. . . . . .)
T’(1,1)α
= T (2,n )[2(dz )2 ] + T (1,n )[-2(dz )2-
2
(dr )2-2hk (dz )
-2hk [1(dr )
+12 (dr ) (n-1) ] ]+
T(1,n-1) [2(dz)2 ]+ 2hTf
k(dz) +
2hT f
k [1(dr)+
12 (dr ) (n-1) ]
Node (m,1) n(m-1)+1
T’(m,1)α
= T(m-1,1)[2(dz)2 ] + T(m,1) [-2(dz)2-
2
(dr)2 ] + T(m,2) [2(dr)2 ]7
Node (m,n)
T'(m,n)α
=T ( m-1,n )[2(dz )2 ] + T (m,n )[-2(dz )2-2
( dr )2-2hk [1(dr )
+12 (dr ) (n-1 ) ]]+
T (m,n-1 )[2(dz )2 ]+ 2hTf
k [1(dr)+
12 (dr )(n-1) ]
Now the temperature can be calculated by passing the array T to ‘ode45’ to solve the transient heat conduction equation.
FIGURES
&
PLOTS
8
9
Fig
ure
6 : H
eisl
er’s
cha
rt
10
Fig
ure
7: H
eisl
er’s
cha
rt
Figure 8: Dimensionless temperature profile for heating.
Figure 9: Temperature vs. Height (at const. radial distance).
11
Figure 10: Temperature vs. Radial Distance (at constant height)
Figure 11: Dimensionless Temperature vs. Dimensionless Time.
12
Figure 12: Temperature profile for heating.
13
COOLING TEMPERATURE PROFILE
Figure 13: Dimensionless temperature profile for cooling.
14
Figure 14: Temperature vs Height (at constant radial distance).
Figure 15: Temperature vs. Radial Distance (at constant height).
15
Figure 16: Dimensionless Temperature vs. Dimensionless Time.
Figure 17: Temperature Profile for cooling.
16
CODE OUTPUT
*****Output for curveplot.m*****
ans =
Heisler Chart Ready
Do you want to plot your data on Heisler chart? (enter 1 for YES) 1Heating (hit 1) or cooling (hit 2)? (enter zero to ignore) 1Please enter the filename with extension which contains data for the heating curve heating.txtHow many readings for heating? (enter zero to ignore) 33
ans =
Convective heat transfer coefficient for heating =1419.26
ans =
Biot number =1.215
ans =
Lumped system analysis invalid
ans =
Data plotted. Check Figure
Do you want to plot your data on Heisler chart? (enter 1 for YES) 1Heating (hit 1) or cooling (hit 2)? (enter zero to ignore) 2Please enter the filename with extension which contains data for the cooling curve cooling.txtHow many readings for cooling?(enter zero to ignore) 87
ans =
Convective heat transfer coefficient for cooling =29.2913
ans =
Biot number =0.025075
17
ans =
Lumped system analysis valid
ans =
Data plotted. Check Figure
Do you want to plot your data on Heisler's chart? (enter 1 for YES) n>>
*****Output for Transient.m*****
ans =
Calculations Completed
ans =
Centre Temperature (K) =369.5298
ans =
Biot number =1.215
ans =
Lumped system analysis invalid
Do you want to continue? (Hit 1 for yes)1ans =
Calculations Completed
ans =
Centre Temperature (K) =308.8151
ans =
Biot number =0.025074
ans =
Lumped system analysis valid
Do you want to continue? (Hit 1 for yes)n>>
18
CONCLUSION
The code gives us the Biot number and convective heat transfer coefficient for both heating
and cooling. For the node configuration of 12x6 the results are found to be accurate and the execution
time too is very small.
As found manually the lumped system analysis is valid only for cooling. In case of heating
the Biot number was much larger than 0.1. When the temperature profile for heating is studied using
‘Transient.m’, it is observed (by studying the matrix ‘Tf’) that the temperature varies significantly
throughout the body at any instant of time. This proves that lumped system analysis is invalid.
The code can further be used to study transient heat conduction with other solids and fluids.
This lets one have a better understanding of the situation before performing the experiment.
REFERENCES
1. Christopher A Long, (2001), Essential Heat Transfer, Addison Wesley Longman
(Singapore) Pte. Ltd., pp.50-57.
2. M. P. Heisler, (1947), Temperature Charts for Induction and Constant Temperature
Heating, Trans. ASME 69, pp. 227–36.
3. D.J. Higham and N.J. Higham, (2000), MATLAB Guide. SIAM.
4. Retrieved April 10, 2009, from
http://www.faculty.virginia.edu/ribando/modules/OneDTransient/
5. Retrieved April 7, 2009, from
http://www.mathworks.com/access/helpdesk/help/toolbox/pde/index.html?/access/
helpdesk/help/toolbox/pde/&http://www.mathworks.com/access/helpdesk/help/
helpdesk.html
19