Q: I have two cooling towers using softened water. It has 0 hardness after softening, pH is 8.75, conductivity is 150 and alkalinity is 40, chlorides are10. The one tower water has a pH of 8.2 in the sump as well as 140hardness, 514 conductivity, 30 chlorides and 180 alkalinity. The other tower has a pH of 7.84, hardness of 200, 549 conductivity, 40 chlorides and 200alkalinity. What is causing my hardness to be so high in the tower and am Iwasting water. Also, do you have any ideas to improve my treatment. The
towers both have rust on the inside walls, and we’re using a treatment withsodium hydroxide in it.
A: The use of softened water in cooling tower systems requires very
FOLLOW US ON SOCIAL MEDIA
Home > Hard or Soft Water for Cooling Towers
ABOUT | CONTACT | ADVERTISE | SUBSCRIBE
Home Buyers Guide Drinking Water Wastewater Urban Stormwater Industrial Water Water Utility Mgmt Environmental World Regions Technologies
d or Soft Water for Cooling Towers - WaterWorld http://www.waterworld.com/articles/iww/print/volume-9/issue-5/colu...
3 2014/06/30 01:53 .
8/11/2019 Hard or Soft Water for Cooling Towers - WaterWorld
http://slidepdf.com/reader/full/hard-or-soft-water-for-cooling-towers-waterworld 2/3
World Water Day 2014: Water used as fuel for processes
and products
Zero to Hero ZLD Potential for the Power Indust ry
Water scarcity now linked to slowing energy production
Corrugator
RELATED ARTICLES
RELATED PRODUCTS
There is no current content available.
special treatment since softened water is very corrosive to ferrous metals.You didn’t specify your treatment program, but following are my comments.The iron build-up in cooling tower indicates that corrosion is going on in thesystem. Dissolved iron will oxidize as it falls through a cooling tower allowing precipitation of iron in fill and in basin. A corrosion inhibitor andiron dispersant will be required to stop corrosion and excess dissolved ironfrom the system. Note: The amount of iron that has already been depositedwill require mechanical and/or chemical cleaning to remove.
You’re operating at about 5 cycles of concentration based on alkalinity
readings. The hardness in cooling tower is coming from an outside source,most likely wind blown dust from the atmosphere. The amount of hardnessin cooling tower cannot be predicted, so you just have to maintaincalcium/alkalinity balance to prevent precipitation of calcium carbonate.Your pH range is within normal limits for the calcium/alkalinity you’recurrently maintaining.
I don’t believe you’re wasting water, although you are at the lower limit of normal range for cycles of concentration (5-7).
Cooling FAQs are provided by the Houston-based Cooling TechnologyInstitute (CTI), a non-profit organization dedicated to improvement in
technology, design, performance and maintenance of cooling towers andevaporative heat transfer systems (EHTS). They’re from the “Ask theExpert” column of CTI Journal. Contact: 281-583-4087 or www.cti.org
More Industrial WaterWorld Issue Articles
More Industrial WaterWorld ArticlesPast IWW Issues
TODAY'S HEADLINES
d or Soft Water for Cooling Towers - WaterWorld http://www.waterworld.com/articles/iww/print/volume-9/issue-5/colu...
3 2014/06/30 01:53 .
8/11/2019 Hard or Soft Water for Cooling Towers - WaterWorld
http://slidepdf.com/reader/full/hard-or-soft-water-for-cooling-towers-waterworld 3/3
Americ an Water earns four national awards fo r water
quality excellence
American Water Works Company has recently received four Partnershipfor Safe Water awards.
Badger Meter, Watertech announc e channel partner
agreement
Badger Meter has entered into a channel partner agreement with
Watertech of America, a total system management provider for thetreatment of water and wastewater in industrial and commercial markets.
New online database reveals groundwater contamination
from coal power plant waste
According to a new online database of state monitoring results,thousands of groundwater samples near coal ash dumps across the U.S.contain arsenic, lead and other pollutants at levels exceeding federalthresholds for safe drinking water.
Company hits m ilestone in Singapore with 12M gallons o f
water sav ings per year
Pratt & Whitney has marked a major environmental milestone with thereduction of annual water consumption by more than 12 million gallonsper year across its Singapore operations.
Drinking Water
Wastewater
Urban Stormwater
Industrial Water
Water Utility Management
World Regions
Environmental
Technologies
WaterWorldCE
Magazines
Webcasts
White Papers
Industry News
RSS Feeds
Buyer's Guide
Classifieds
Jobs
WaterWorldTV Videos
Industry Links
Research
Topic Index
Contact Us
Advertising
Subscribe
About Us
PennWell Events
PennWell Websites
Register
Login
Forgot Password
Change Password
Site Map
TOPICS RESOURCES ABOUT US SUPPORT STAY CONNECTED
© 2014. PennWell Corporation. All Rights Reserved. PRIVACY POLICY | TERMS AND CONDITIONS
d or Soft Water for Cooling Towers - WaterWorld http://www.waterworld.com/articles/iww/print/volume-9/issue-5/colu...
3 2014/06/30 01:53
Top Related