8/8/2019 guia rapida atv28
1/1
ESC
ENT
ENT
Menu 1 Adjustment Menu (SEt)Factory
Parameter Code Setting
Speed Reference via the Display ModulePI ReferenceDirection of OperationAcceleration TimeDeceleration TimeAcceleration Ramp #2Deceleration Ramp #2Low SpeedHigh SpeedMotor Full Load Current (protection)Optimize Low Speed Torque (voltage boost)Slip Compensation
Frequency Loop GainDC Injection Braking CurrentDC Injection Braking Time at StandstillSkip FrequencyJog FrequencyPI Regulator Proportional GainPI Regulator Integral GainPI Feedback Multiplication CoefficientPI Regulator Reverse CoefficientPreset Speed 2ndPreset Speed 3rdPreset Speed 4thPreset Speed 5thPreset Speed 6thPreset Speed 7thFrequency Threshold where R2 ClosesCurrent Threshold where R2 ClosesMotor Thermal where R2 ClosesLow Speed Operation Time
Menu 2 Drive Menu (DrC)Factory
Parameter Code Setting
Nominal Motor VoltageNominal Motor FrequencyAuto-tuningMaximum Output FrequencyType of Volts/Hz RatioAutomatic Ramp Modification for DecelAlternate Accel/Decel Ramp FrequencyCarrier Switching FrequencyRandom Carrier Frequency ModulationAutomatic RestartEnable Output Phase Failure FaultEnable Line Supply Phase Failure FaultControlled Stop on Loss of Line SupplyEnable Smooth Restart after FaultLower Tripping Threshold of UndervoltageScale Factor of Output Frequency for SpeedReturn to Factory Settings
Menu 3 I/O Menu (I-O)Factory
Parameter Code Setting
Control Strategy Configuration (2-wire/3-wire)2-Wire Control3-Wire ControlPresence of Local Control Option
Enable for Start/Stop using Remote DisplayLogic Input 2 AssignmentLogic Input 3 AssignmentLogic Input 4 Assignment
Not AssignedReverse RotationRamp Switching
ALTIVAR 28 Quick Reference Guide
Jog Operation2 Preset Speeds4 Preset Speeds8 Preset SpeedsFreewheel StopDC Injection BrakingFast StopForced Local ModeFault ResetAnalog Speed Reference Switching
Analog Input Assignment of 2nd InputNot AssignedSumming with All
PI Regulator Feedback, setpoint = parameter rP1PI Regulator Feedback, setpoint = AllMinimum Value on Analog Current InputMaximum Value on Analog Current InputAssignment of Analog Output
Not AssignedMotor CurrentMotor FrequencyMotor TorqueDrive Power Supplied
Assignment of Offset for Analog OutputAssignment of R2 Relay
Not AssignedFrequency Threshold ReachedCurrent Threshold ReachedSpeed Reference ReachedMotor Thermal Threshold Reached
Drive Address via Serial LinkSerial Link Transmission Speed
Menu 4 Display Menu (SUP)Factory
Parameter Code Setting
Control Strategy Configuration (2-wire/3-wire)Enable for Start/Stop using Remote DisplayDisplay Calculated Value of Speed or
Production Rate (rFr X SdS)Display Motor CurrentDisplay Motor PowerDisplay Line VoltageDisplay Motor Thermal StateDisplay Drive Controller Thermal StateDisplay Last FaultDisplay Drive Controller Software VersionAccess Code ProtectionDisplay of Controller Status
If it is not possible to access the SEt-,
drC- or I-O- menus, the drive controller
is protected by an access code. A remote
display module option or PC software is
necessary to access these menus, together
with knowledge of the code.
Access to Menus
ENT
ENT
ESC
ESC
-bFr
SEt
SUP-
drC
I-O-
rdY
----
bFR configuration (1)
ENT
0.0For3 sec3 sec5 sec5 sec0 Hz(bFr)(In)200.05.0 Hz
330.7In0.5 sec0 Hz10 Hz11 /s1no10 Hz15 Hz20 Hz25 Hz30 Hz35 Hz(bFr)1.5In100%0
230/460V50/60 Hzno60/72 HznYES0 Hz4.0YESnoYESYESnonono30no
2C
norrSPS2PS4
SAI
4 mA20 mArFr
0SrA
119.2
HzHzA%V%%
FactoryParameter Code Setting
1st power-up after factory configuration
Access to Parameters
SEt-
Menu Parameter
Next parameter
Value or assignment
1 flash(save)
Subsequent power-ups
Display of drive controller status
Wait 3 seconds
Settings
Drive
I/O
Display
Base frequency:50 Hz (factory setting)or 60 Hz
vv
vv
vv
vv
vv
-YYY 100
101-UUU 101
ENT
ESC
Keypad Operation & Reference
Using the Keypad Display
Red LED: powered up(DC bus voltage)
Returns to theprevious menu orparameter, orincreases thedisplayed value
Enters a menu or aparameter, or saves
the displayedparameter or value
Exits a menu or parameter,
or aborts the displayed valueto return to the previousvalue in the memory
Goes to the next menu orparameter, or decreasesthe displayed value
4 seven-segment displaysrdY
Altivar28
z
vENTESCv
LFr
rPI
rOt
ACC
dEC
AC2
dE2
LSP
HSP
ItH
UFr
SLP
FLG
IdC
tdC
JPF
JOG
rPG
rIG
rbS
PIC
SP2
SP3
SP4
SP5
SP6
SP7
Ftd
Ctd
ttd
tLS
UnS
FrS
tUn
tFr
Ft
brA
Frt
SFr
nrd
Atr
OPL
IPL
StP
FLr
drn
SdS
FCS
tCC
2C
3C
OPt
LCC
LI2
LI3
LI4
no
rrS
rP2
JOG
PS2
PS4
PS8
nSt
dCI
FSt
FLO
rSt
rFC
AIC
no
SAI
PII
PIA
CrL
CrH
AO
no
Ocr
rFr
OLO
OPr
AOt
r2
no
FtA
CtA
SrA
tSA
Add
bdr
FrH
rFr
SPd
LCr
OPr
ULn
tHr
tHd
LFt
CPU
COd
The parameters in colored boxes appear if the correspondingfunctions have been configured in the dcr or I/O menus.
Menu 3 I/O Menu (I-O) continued
Electrical equipment should be serviced only by qualified personnel. No responsibility is
assumed by Schneider Electric for any consequences arising out of the use of thismaterial. This document is not intended as an instruction manual for untrained persons. Document Number 8806HO0102