Geyser Hybrid Pump (GHP)Low Cost, Low Energy for Grit Removal(Patent Pending)

Operating pressure = [Submergence (ft) + GEP height (ft)] x 0.43 (psi/ft)] Air flow [DCFM] = # [pulses/min] x Delivered air volume to GEP [ft3/pulse] Air flow [SCFM] = [Operating pressure (psi) + 14.7 (psi)]/14.7 (psi) x Air flow [DCFM]Flow rate:# pulses/min x gallon/pulse = flow (gpm)

Delivered Air Flow to GHP [ft3 / pulse]

Delivered Liquid and Grit to GHP [gallon / pulse]

Radii of InfluenceRadii of Influence

Typical Grit Pit Placement

Design Criteria

2”GHP 3”GHP 4”GHP 12”GHP

0.13 0.35 0.52 6.12

2”GHP 3”GHP 4”GHP 12”GHP1.1 2.4 4.3 38.9

Pumping rate Velocity Air flow Power of Blower Max Grit size4" Geyser Hybrid Pump 35 GPM 18 ft/sec 20 SCFM @ 3.5 psig 0.8 BHP 24.0 mm

4" Airlift Pump 35 GPM 0.89 ft/sec 44 SCFM @ 3.5 psig 1.4 BHP 2.5 mm

WL

Submergence = 8 feet, Lift = 7 feet

Performance comparison of Airlift Pump versus GHP