Download - Getting Started with E-Sys 3.18 - f10.m5post.com

Transcript
Page 1: Getting Started with E-Sys 3.18 - f10.m5post.com

Getting Started with E-Sys 3.18.4 • Connect ENET cable between car's OBD port and

network port of laptop. • Ensure laptop WiFi is disabled and all cell phones near

car have BT turned off. • Start the engine or provide external power.

– It is safe to run the engine as long as you are not coding in the Digital Motor Electronics (DME) ECU.

• Wait a minute until the network icon on laptop shows a Connection with the yellow exclamation point over it.

• Open E-Sys.

Page 2: Getting Started with E-Sys 3.18 - f10.m5post.com

Press the connect button on top row of E-Sys to connect car with the laptop. This will open a popup dialogue box.

Page 3: Getting Started with E-Sys 3.18 - f10.m5post.com

Select the correct TargetSelector, e.g. F010, not F010_DIRECT Select "connection via VIN" and press Connect. Click Ok when connection established.

Page 4: Getting Started with E-Sys 3.18 - f10.m5post.com

Select "Expert Mode“. click on "Coding" button. In Vehicle Order Box, click on "Read" button. This will display the car’s FA .

Page 5: Getting Started with E-Sys 3.18 - f10.m5post.com

In the SVT Actual Box click on "Read(VCM)" button. The SVT box will display the car’s different modules.

Page 6: Getting Started with E-Sys 3.18 - f10.m5post.com

Right click FA Select Activate FA

Page 7: Getting Started with E-Sys 3.18 - f10.m5post.com

Right click the CAFD file under the Module you want to read. Select “Read Coding Data”

Page 8: Getting Started with E-Sys 3.18 - f10.m5post.com

A new option will appear under the CAFD folder. Expand to view the new folder by clicking “+”. Right click that new folder, Select “EDIT FDL”

Page 9: Getting Started with E-Sys 3.18 - f10.m5post.com

Select the Section you wish to modify. Expand to view the section’s folder by clicking “+”.

Page 10: Getting Started with E-Sys 3.18 - f10.m5post.com

Expand the “Funktionen” folder by clicking “+”. This will expand the folder into a list of Function Values.

Page 11: Getting Started with E-Sys 3.18 - f10.m5post.com

Locate the Function Value that you want to configure Expand to view the folder by clicking “+”. Select the second option (Ausgelesen) Expand to view the folder by clicking “+”. Right click on Aktiv or Nicht_Aktiv, select Edit

Page 12: Getting Started with E-Sys 3.18 - f10.m5post.com

Change setting as desired (in this case “Aktiv”)

Page 13: Getting Started with E-Sys 3.18 - f10.m5post.com

*ONLY IF WERTE VALUE NEEDS TO BE CHANGED* (normally NOT done, and never in combination with change to aktiv, nicht_aktiv. Only one of the two settings changes) First, Right click on Werte, select Edit

Then, Enter new value in “Values from ECU” box Select Apply Changes

Page 14: Getting Started with E-Sys 3.18 - f10.m5post.com

Click on the “Save” icon

Page 15: Getting Started with E-Sys 3.18 - f10.m5post.com

Click the green back arrow

Page 16: Getting Started with E-Sys 3.18 - f10.m5post.com

Select the CAFD file that you just edited Click “CODE FDL”

Page 17: Getting Started with E-Sys 3.18 - f10.m5post.com

When coding is complete, click “Close” An error report will open. Close or Save as needed.

Page 18: Getting Started with E-Sys 3.18 - f10.m5post.com

Repeat steps as needed When complete, disconnect, then exit E-Sys