14th Canadian Conference on Building Science and Technology - Toronto Canada
Assessing the Effects of Climate Change on Buildings using the Engineer’s Canada PIEVC Process
Gerald R. Genge, and Dale D. Kerr
Overview1. What is PIEVC and How does it work?2. Case Study Building3. Relevant Climate Parameters based on Aggregate of
Models4. Relevance to the Building Components5. Change in the Parameters Risk Assessment (related to
Buildings and Occupancy)6. Proposed Action Items
14th Canadian Conference on Building Science and Technology - Toronto Canada
PIEVC• Public Infrastructure Engineering Vulnerability Committee
• Established in 2005 by Engineers Canada and Natural Resources Canada to oversee the planning and execution of the assessment of the vulnerability of Canadian public infrastructure to changing climatic conditions.
• The PIEVC established four areas to review:1. Storm water and wastewater collection and treatment systems;2. Roads and associated structures;3. Water resource systems; and4. Buildings
14th Canadian Conference on Building Science and Technology - Toronto Canada
PIEVC Steps
14th Canadian Conference on Building Science and Technology - Toronto Canada
PIEVC Process• A five step protocol to assure consistent and fair
assessment of the effects of climate change on infrastructure
• Involves a rigorous review of the climatic parameters that are expected to change along with an assessment of the impact those changes are expected to have on buildings.
• The period of time during which the infrastructure is expected to operate is 50 years.
14th Canadian Conference on Building Science and Technology - Toronto Canada
Project Team• Consultant team members included:
• GRG and Heather Auld (Climatologist)
• Stakeholder team members were drawn from:• TCHC• City of Toronto Tower Renewal program staff, • Property management and maintenance personnel • City of Toronto Departmental representatives, • PIEVC Project Lead, • PIEVC Buildings Expert Group Lead, • Ontario Government Ministry representatives for Environment and
for Infrastructure.
14th Canadian Conference on Building Science and Technology - Toronto Canada
Step : Project Definition
PIEVC Steps Building Selection
• Client selected this property as representative of the largest proportion of the portfolio being 40 to 50 years old.
14th Canadian Conference on Building Science and Technology - Toronto Canada
The Building• 16-storey apartment building, • Constructed in 1964,• Typical of similar buildings of the vintage, • The study benefitted from recently completed
assessments on building condition and energy performance.
14th Canadian Conference on Building Science and Technology - Toronto Canada
Step 2: Data Gathering
PIEVC Steps Data Gathering and Sufficiency of Data
• 179 building components were reduced to 30 by ranking in importance and considering probable effect of climate change on the component.
• Air conditioning was then added as a key component to be considered.
14th Canadian Conference on Building Science and Technology - Toronto Canada
Exterior Wall Design
18 C
-18 C
14th Canadian Conference on Building Science and Technology - Toronto Canada
Window Design
14th Canadian Conference on Building Science and Technology - Toronto Canada
14th Canadian Conference on Building Science and Technology - Toronto Canada
Component Inventory • Major components in the assessments include:
• Grounds and Site• Structure and Envelope• Roofing• Elevators• Electrical• Mechanical, and • Life Safety Systems
14th Canadian Conference on Building Science and Technology - Toronto Canada
Component Importance RankingBuilding Component Importance (to Client)
Grounds and SiteDriveway, Parking, Walks, Drainage 5
Structure and Building EnvelopeBalcony and Railings 6Foundation Walls 7Doors and Windows 5Exterior Cladding 7
Roofing 5
ElevatorsEquipment 6
14th Canadian Conference on Building Science and Technology - Toronto Canada
Component Importance RankingBuilding Component Importance (to Client)
ElectricalEquipment 6Lighting6
MechanicalMake-up Air and Convection Radiators 6Supply and Exhaust Ducting 5Heating Boilers 7Stormwater Removal 6Air Conditioning1
Life SafetyGenerator, Transfer Switch, Transformers 6
14th Canadian Conference on Building Science and Technology - Toronto Canada
Window air-conditioners14th Canadian Conference on Building Science and Technology - Toronto Canada
Relevant Climate Events: Parameter Data
Temperature Historical
(usually 1971-2000)
2050s (Ensemble Projections)
Relative Change
(% less % more)
# days ≥ 30°C 15 40 +166%
# days ≥ 35°C 0.5 4 +700%
NBCC 2.5% July Dry Bulb Design Temperature 31°C 34°C
+9%
NBCC 1% January Dry Bulb Design Temperature -20°C -16°C
-20%
30-year period Extreme High Temperature 37°C 40°C
+8%
Annual Average Cooling Degree-days 356 640 +80%
Annual Average Heating Degree-days 3520 2900 -18%
Average Annual Freeze-Thaw Cycles 55 ~40 -27%
Average Annual Days < -20°C 1.4 0.3 -78%
Average Annual Heat Related Mortalities 120 280 +133%
14th Canadian Conference on Building Science and Technology - Toronto Canada
Relevant Climate Events: Precipitation
Historical(usually 1971-
2000)
2050s (Ensemble
Projections)
Relative Change
(% less % more)
Average annual # wet days 113 ~ 125 +7%
Extreme annual precip (30-yr period) 1828 mm ~1940 mm 6%
Average Annual Precipitation 835 mm ~ 890mm 7%
Average annual Rainfall 710 mm ~> 800 mm +13%
NBCC 10 yr return period 15 min. rainfall 25 mm Likely increasing +
NBCC 50 yr return period 1 day rainfall 97 mm Increasing ~ 60% +60%
Average # days with > 25 mm rainfall 4.2 > 5 +2%
Maximum consecutive Dry days/year ~ 13 Likely increasing +
Driving Rain Wind Pressures (5-yr return period) 160 kPa Likely increasing
+
mNBCC design Ground Snow Loads Ss-0.9, Sr=0.4 kPaRain with snow and
intense storms - increase
+
Rain on snow events, snowmelt Increasing +
14th Canadian Conference on Building Science and Technology - Toronto Canada
Relevant Climate Events: Extreme Wind
Historical(usually 1971-
2000)
2050s (Ensemble
Projections)
Relative Change
(% less % more)
NBCC 10 year return period wind pressures 0.34 kPa Likely increasing
+
NBCC 50 year return period wind pressures 0.44kPa Likely increasing
+
Average # hours/year > 70kph 24 (for 1994-2007) 26 (Pearson Area) +8%
Average # hours/year with Gusts > 80kph 5.9~7 mostly spring and
fall+2%
Average # hours/year with Gusts > 90kph 1.0 h ~1.9 h +90%
Tornado risks May increase +
Severe thunderstorm Average 1-2 d/yr Potential increases +
14th Canadian Conference on Building Science and Technology - Toronto Canada
Step 3: Risk AssessmentR = P x S
R = Risk P = Probability of a Negative Event S = Severity of the Event
PIEVC Steps Risk Assessment
14th Canadian Conference on Building Science and Technology - Toronto Canada
Probability / Importance Assessment for Climate Parameters
Probability Score (P)
Probability RankingMethod B
0 Not Applicable1 Recognize existence and include with other components3 Interested – Analyze if budget allows5 Analyze normally6 Relatively important – Analyse with more attention7 Important – Analyze with much more attention
14th Canadian Conference on Building Science and Technology - Toronto Canada
Severity Criteria and RankingScore (S)
Severity of Consequences and EffectsMethod A Method B
0 No Effect Negligible - Not Applicable
1 Measurable Very Low - Some Measurable Change
2 Minor Low - Slight Loss of Serviceability3 Moderate Moderate Loss of Serviceability
4 Major Major Loss of Serviceability - Some Loss of Capacity
5 Serious Loss of Capacity - Some Loss of Function
6 Hazardous Major - Loss of Function7 Catastrophic Extreme - Loss of Asset
14th Canadian Conference on Building Science and Technology - Toronto Canada
Risk Criteria from R = P x SRisk Range Threshold Response
< 12 Low Risk No Action necessary 12 - 36 Medium Risk Action may be required
Engineering analysis may be required
> 36 High Risk Action is Required
14th Canadian Conference on Building Science and Technology - Toronto Canada
Results of Risk Analysis
14th Canadian Conference on Building Science and Technology - Toronto Canada
Tota
l rai
nfal
l
Hea
vy ra
in
Rai
n on
sno
w e
vent
s
Sno
w a
ccum
ulat
ion
Sno
w L
oads
Sno
wm
elt
Sev
ere
Ice
Sto
rms
Com
bine
d R
ain/
Win
d
Dry
spe
lls
Hig
h w
ind
spee
ds
Ligh
tnin
g, S
ever
e Th
unde
rsto
rms
Torn
adoe
s
Ext
rem
e H
eat
Coo
ling
degr
ee d
ays
Sun
ny d
ays
Hum
iditi
es
Ext
rem
e C
old
Hea
ting
degr
ee d
ays
Free
ze-th
aw
Driveways/Surface Parking 14 19 23 19 6 21 26 2 4 3 1 1 23 2 2 6 0 0 18
Sidewalks/Steps/Curbs/Patios 12 18 21 19 6 21 28 2 4 2 1 1 14 2 2 6 0 0 18
Drainage 18 28 33 16 5 14 14 4 9 2 1 5 2 2 2 1 0 0 0
Balcony Decks 2 4 12 11 15 12 14 12 9 2 1 1 2 2 2 6 0 0 12
Balcony Railings 2 2 2 4 3 2 2 2 9 23 1 9 2 2 2 1 0 0 0
Foundation Walls 12 21 11 4 3 14 2 2 4 2 1 1 2 2 2 1 0 0 0
Caulking 2 2 4 4 6 2 4 7 11 6 1 3 25 5 5 3 8 0 6
Doors 9 16 12 5 3 2 5 11 11 24 1 10 2 11 12 2 5 9 0
Exterior Cladding General 18 26 2 4 5 2 4 14 11 20 1 10 12 14 12 4 5 12 20
Windows 14 28 2 4 6 2 5 21 12 27 1 12 28 25 23 10 8 18 0
General Roof Repairs/Replace 2 25 2 9 18 2 21 7 12 5 1 11 23 16 25 2 7 12 0
Roof Flashings 2 2 2 4 4 2 5 16 12 15 1 9 2 2 2 2 0 0 0
Elevator Electrical Equipment 2 2 2 4 1 2 2 2 2 9 1 1 21 2 2 1 0 0 0
Elevator Sump 2 28 5 4 1 14 2 2 2 2 1 1 2 2 2 1 0 0 0
Exterior Lighting 2 2 2 7 4 2 11 7 12 2 1 11 2 2 2 1 0 0 0
Air Makeup System 2 2 2 4 1 2 12 2 11 6 2 1 18 19 5 1 6 18 0
Convection Radiators 2 2 2 2 1 2 2 2 2 2 1 1 5 11 7 1 2 0 0
Ducting - Exhaust 2 2 2 7 1 2 2 2 2 2 1 1 5 19 2 1 0 0 0
Ducting - Supply 2 2 2 4 1 2 2 2 2 6 1 1 7 19 2 1 0 5 0
Heating Boilers 2 9 2 2 1 2 2 2 2 2 1 1 2 5 5 1 0 14 0
Heating System - General 2 2 2 2 1 2 2 2 2 2 1 1 2 5 5 1 0 0 0
Heating System - Units 2 2 2 2 1 2 2 2 2 2 1 1 2 5 5 1 0 14 0
Storm Water Removal General 14 26 23 23 10 12 12 11 7 2 1 5 2 2 2 1 0 0 0
Heating Pumps 2 9 2 2 1 2 2 2 2 2 1 1 2 7 5 1 0 5 0
Heating Supply Lines 2 2 2 2 1 2 2 2 2 2 1 1 2 7 5 1 0 4 0
Air-Conditioning 2 2 2 2 1 2 2 2 2 11 3 2 42 32 5 7 0 0 0
Exhaust - General 2 2 2 2 1 2 4 2 2 11 3 1 16 19 5 7 3 7 0
Emergency Generator 2 2 4 2 1 2 32 2 2 26 11 11 19 2 2 1 0 0 0
Transfer Switch 2 2 4 2 1 2 16 2 2 17 6 5 2 2 2 1 0 0 0
Transformer 2 2 2 2 1 2 2 2 2 11 8 1 21 2 2 1 0 0 0
Roofing
Elevators
Climate Factor
Building Component
Grounds/Site
Structural
Building Envelope
Electrical
Mechanical
Life Safety
83.3% Low Risk
16.5% Moderate Risk
0.2% High Risk
Step 4: Engineering Analysis
• PIEVC Steps • Engineering Analysis
• No engineering analysis conducted as there are no empirical relationships established for climate loads on cladding, windows in the mNBCC.
14th Canadian Conference on Building Science and Technology - Toronto Canada
Step 4: Recommendations
• PIEVC Steps • Recommendations
Building Action Items• Overcladding• Window Replacement• Air Conditioning
Management Action• Increased maintenance• Monitor health effects of
climate change• Staff training/ tenant education
14th Canadian Conference on Building Science and Technology - Toronto Canada
Looking ahead • Over the next 40 years, the climatic changes expected in
southern Ontario include increased:• temperature;• frequency and intensity of heavy precipitation events and short
intense rainfalls (e.g. thunderstorms);• frequency and longevity of heat waves; • intensity of winter snowfalls due to more atmospheric moisture,
particularly in the lee of the Great Lakes and in freezing rain risks; and,
• Potential increases in extreme wind gusts.… and the resultant weathering processes including humidity, wetting, wind driven rain, carbonation, etc.;
14th Canadian Conference on Building Science and Technology - Toronto Canada
Additional Research 1. Currently, buildings are designed using climatic
parameters calculated from historical climate data assumed to represent the conditions expected over the life of the building. As the climate changes, this assumption will no longer hold.
2. Building Envelope Design Standards should develop empirical relationships including load factors that accommodate climate prediction into the future life of the building.
14th Canadian Conference on Building Science and Technology - Toronto Canada
???
Questions and Discussion
Thank you for your attention and enjoy the rest of the conference….
14th Canadian Conference on Building Science and Technology - Toronto Canada
Gerald R. Genge, B.A.Sc., P.Eng., C.Eng., BDS, BSSO, C.Arb., Q.Med.
Dale D. Kerr,M.Eng., P.Eng., BSSO, ACCI
Top Related