| INTERFACE BOX | | D C S S |
(security link) | | | |
EDS --------->+ +---> ---------> /EDS (110V) |
TCI --------->+ +---> ---------> /TCI (110V) |
| .----. | | |
SGSin -------->+----->+ & | | | |
EFS -------->+--+-->+ +---->+--------------> DOB (30V) |
| | `----' | | |
Forced Close-->+ +--------------+--------------> /NDG (to HL2) |
| | | |
(controller sig.) | | | |
DO --------->+--+--- DO ---+->+--------------> DO (30V) |
DC ------------>+----DO/DC--+ | | |
| | | |
Int.SPEED ---->+ +--------------> /SO (to HL2) |
| | | |
| | | |
(outputs) | .-------. | | |
7/25/2019 GAA 24350 AW11 II.pdf
8/22
Interface Signal: DCSS input:
Name | Connector || Name | Connector
volt. range | IN --> OUT || |
-------------------------------------------------------------------------
EDS Emergency Door Stop (Safety Link) || |
48 to 110V | P7/10 to P7/12 --> P3/2 || EDS | P2.1 (110Vac)
>110V | P7/11 to P7/12 --> || | -----------------------------------------------++---------+--------------
TCI Top of Car Inspection (Safety Link) || |
48 to 110V | P7/7 to P7/9 --> P3/3 || TCI | P2.2 (110Vac)
>110V | P7/8 to P7/9 --> || |
-----------------------------------------------++---------+--------------
SGSin Reversal Signal Input || |
48 to 110V | P7/4 to P7/6 --> P5/10 || DOB | P5.7 (30V)
>110V | P7/5 to P7/6 --> || | note 1
-----------------------------------------------++---------+--------------
EFS Emergency Fireman Service ||
48 to 110V | P7/1 to P7/3 ||
>110V | P7/2 to P7/3 || note 1
-----------------------------------------------++---------+--------------
DO Door Open Signal || |
48 to 110V | P6/10 to P6/12 --> P5/9 || DO | P5.8 (30V)
>110V | P6/11 to P6/12 --> || | note 2
-----------------------------------------------++---------+---------------
DC Door Close Signal ||
48 to 110V | P6/7 to P6/9 ||
>110V | P6/8 to P6/9 || note 2
-----------------------------------------------++---------+---------------
2nd Prof Second Speed Prof. Signal || |
48 to 110V | P6/4 to P6/6 --> P5/11 || /SO | P5.4 (to HL2)
>110V | P6/5 to P6/6 --> || | note 3
-----------------------------------------------++---------+--------------- NDG Nudging (forced closing) || |
48 to 110V | P6/1 to P6/3 --> P5/12 || NDG | P5.5 (to HL2)
>110V | P6/2 to P6/3 --> || |
-----------------------------------------------++---------+---------------
7/25/2019 GAA 24350 AW11 II.pdf
9/22
Name Plug Description
Brake / Make cont.
---------------------------------------------------------------------
REL1 | P4/1-3 / P4/1-2 | used as Door Open Limit switch (DOL)
| | ------+-----------------------+---------------------------------------
REL2 | P4/4-6 / P4/4-5 | Set before door is fully closed (XMC)
| | (used for gearless elevator)
------+-----------------------+---------------------------------------
REL3 | P4/7-9 / P4/7-8 | used as Door Fully Closed (DCL)
| |
------+-----------------------+---------------------------------------
REL4 | P4/10-12 / P4/10-11 | used as SGL signal
| | Signal to weak the sensitivity of EDP
------+-----------------------+---------------------------------------
REL5 | P5/1-3 / P5/1-2 | Set before door is fully closed (PMY)
| | (used for high speed drive)
------+-----------------------+---------------------------------------
REL6 | P5/4-6 / P5/4-5 | Door reopen signal with adjustable
| | delay (SGSout)
------+-----------------------+---------------------------------------
7/25/2019 GAA 24350 AW11 II.pdf
10/22
7/25/2019 GAA 24350 AW11 II.pdf
11/22
,-----------------.
| SET UP ROUTINE |
| GOON WITH ENTER |
`-----------------'
,-------------------.
| DEFAULT PARAMETER?|
7/25/2019 GAA 24350 AW11 II.pdf
12/22
| YES = 1 NO = 2 |
`-------------------'
,-------------------.
| Interf: nnnnnnnn | nnnnnnn = DISCRETE
| use GOON / ENTER | SERIAL
`-------------------' Interf.BOX
7/25/2019 GAA 24350 AW11 II.pdf
13/22
,------------------.
| ADDRESS: nnnnnn | nnnnnn = DCSS_1 | use GOON / ENTER | DCSS_2
`------------------' DCSS_3
DCSS_4
,------------------.
| LINE TERMINATOR |
| YES = 1 NO = 2 |
`------------------'
,------------------.
| CONTROLLER TYPE: |
| use GOON / ENTER |
`------------------'
,------------------. ,------------------. | Type: MCS 411 | OR | Other (311...) |
| use GOON / ENTER | | use GOON / ENTER |
`------------------' `------------------
,------------------.
| DOS Signal ? |
| YES = 1 NO = 0 |
`------------------'
7/25/2019 GAA 24350 AW11 II.pdf
14/22
7/25/2019 GAA 24350 AW11 II.pdf
15/22
,------------------.
| CHK MOTOR ROTATN |
| CLS=1 OPN=2 NO=3 |
`------------------'
,------------------.
| DOOR IS nnnn | nnnn = OPENING
| YES=1 NO=2 | CLOSING
`------------------'
,-----------------.
| ERR ROTOR SENSE |
| GOON WITH ENTER |
`-----------------'
,------------------.
| ROTOR SENSE OK |
| GOON WITH ENTER |
`------------------'
,------------------.
| CHECK ENCODER |
| CLS=1 OPN=2 NO=3 |
`------------------'
,------------------.
| ENCODER OK? nn | nn = >< (closing)
| YES = 1 NO = 2| (opening)
`------------------'
7/25/2019 GAA 24350 AW11 II.pdf
16/22
,------------------.
| ENCODER SENSE OK |
| GOON WITH ENTER |
`------------------'
,------------------. Start Learn Run.
1) | START LEARN RUN |
| PRESS |
`------------------'
,------------------. Find closed position.
2) | LEARN RUN |
| DOOR is CLOSING |
`------------------'
3) ,------------------. Check encoder signals.
| LEARN RUN |
| DOOR is OPENING |
`------------------'
4) ,------------------. Learning the door way.
| LEARN RUN | | POSITION: xx[mm]|
`------------------'
5) ,------------------. Confirm the door way and
|POSITION: xx [mm]| leave Installation Run with
| FINISH PRESS "M" | the "M"odule Key.
`------------------'
7/25/2019 GAA 24350 AW11 II.pdf
17/22
7/25/2019 GAA 24350 AW11 II.pdf
18/22
7/25/2019 GAA 24350 AW11 II.pdf
19/22
[]
Output: Parameter Setting: Relay is:
][ ...............[]
REL_1 : distance to fully open _________________XXX
REL_2 : distance to fully closed XXXX________________ REL_3 : distance to fully closed XXX_________________ note 1)
REL_4_CLOSE: distance to fully closed
REL_4_OPEN: distance to fully open XXX______________XXX
REL_5 : distance to fully close XXX_________________
XXX relay is on
___ relay is off
REL_6 : delay time in [ms]
REL6 is time controlled and triggered with the SGSinput signal.
The Time delay is programmable and can be adjusted in [ms].