HW
MCW
==
HO
T WATER
MAIN
S C
OLD
WATER
CCW
=C
ISTE
RN
CO
LD W
ATER
KEY
TO
ILET
WA
SH
HA
ND
BA
SIN
SIN
K
EQ
UIP
MEN
T
HWR
=H
OT W
ATER R
ETUR
N
=B
LEND
ED W
ATERBW
WC
WB
SK
BA
TH
B
UR
INA
L C
IST
ER
NU
C
ELEC
TR
IC SH
OW
ER
ES
MIX
ER
SH
OW
ER
MS
BELFA
ST SIN
KB
SK
EM
ER
GEN
CY
EY
E W
ASH
Em
SEM
ER
GEN
CY
SH
OW
ER
EEW
DIS
H W
ASH
ER
DW
WA
SH
ING
MA
CH
INE
WM
SLU
ICE
SL
DR
INK
S MA
CH
INE
DM
DR
INK
ING
WA
TER
FO
UN
DT
AIN
DW
F
CH
ILLED
WF
CW
F
FIT
TIN
GS
PR
V
ST
RA
INER
PR
ESSU
RE V
ESSE
L
NO
N R
ET
UR
N V
ALV
E
DO
UBLE C
HEC
K V
ALV
E
PU
MP
PIP
E B
REA
K
DR
AIN
/ SA
MPLE P
OIN
T
FIL
TER
DEA
D L
EG
MET
ER
M
PT
TEM
PER
AT
UR
E /
PR
ESSU
RE G
AU
GE
PR
ESSU
RE R
ELIE
F V
ALV
E
TU
ND
ISH
EQ
UIP
MEN
T S
YM
BO
LS
LO
W P
RESSU
RE H
OT
WA
TER
ST
OR
AG
E C
ALO
RIFIE
R
IMM
ER
SION
HEA
TER
SEN
TIN
EL O
UT
LET
S1
2
34
56
78
9
1LPH
WSC
ELEC
TR
IC ST
OR
AG
E
CA
LO
RIFIE
R2
ESC
REM
OT
E G
AS
WA
TER
HEA
TER
(CO
MB
I)3
RG
WH
REM
OT
E E
LEC
TR
ICW
AT
ER
HEA
TER
4R
EW
H
INST
AN
TA
NEO
US
HO
T W
AT
ER
HEA
TER
5IH
WH
HY
DR
OB
OIL
6H
B
7
ELEC
TR
IC ST
OR
AG
E
CA
LO
RIFIE
R8
ESC
*
9 - T
- TA
NK
BIB
TA
PB
T
HO
SE R
EEL / F
IRE H
OSE
REEL
HR
/ FH
R
PR
ESS
UR
ISAT
ION
UN
ITPU
WA
TER
SO
FT
EN
ING
PLA
NT
WSP
DIR
EC
T G
AS F
IRED
W
AT
ER
HEA
TER
DG
FW
HD
G
FW
H
RG
WH
VA
LV
E - O
PEN
/ CLO
SED
TM
V / T
T
VOID ROOFGROUND FLOOR
MC
WS 1
SV
REW
H 1
WB
WC
TO
ILET
001
WB
WC
AC
CESS
TO
ILET
002
REW
H 2
3x
WB
3x
WC
GIR
LS
TO
ILET
003
REW
H 3
2x
WB
2x
WC
BO
YS
TO
ILET
004
SK
*
CLEA
NER
S005
SK
*
CLA
SSR
OO
M007
REW
H 4
WB
SKD
W
KIT
CH
EN
008
SK
AR
T A
REA
009
REW
H 5
SK
ST
AFF
RO
OM
010
2x
BT
OU
TSID
E011
*
CO
RR
IDO
R006
WC
H
*
HW
MCW
==
HO
T WATER
MAIN
S C
OLD
WATER
CCW
=C
ISTE
RN
CO
LD W
ATER
KEY
TO
ILET
WA
SH
HA
ND
BA
SIN
SIN
K
EQ
UIP
MEN
T
HWR
=H
OT W
ATER R
ETUR
N
=B
LEND
ED W
ATERBW
WC
WB
SK
BA
TH
B
UR
INA
L C
IST
ER
NU
C
ELEC
TR
IC SH
OW
ER
ES
MIX
ER
SH
OW
ER
MS
BELFA
ST SIN
KB
SK
EM
ER
GEN
CY
EY
E W
ASH
Em
SEM
ER
GEN
CY
SH
OW
ER
EEW
DIS
H W
ASH
ER
DW
WA
SH
ING
MA
CH
INE
WM
SLU
ICE
SL
DR
INK
S MA
CH
INE
DM
DR
INK
ING
WA
TER
FO
UN
DT
AIN
DW
F
CH
ILLED
WF
CW
F
FIT
TIN
GS
PR
V
ST
RA
INER
PR
ESSU
RE V
ESSE
L
NO
N R
ET
UR
N V
ALV
E
DO
UBLE C
HEC
K V
ALV
E
PU
MP
PIP
E B
REA
K
DR
AIN
/ SA
MPLE P
OIN
T
FIL
TER
DEA
D L
EG
MET
ER
M
PT
TEM
PER
AT
UR
E /
PR
ESSU
RE G
AU
GE
PR
ESSU
RE R
ELIE
F V
ALV
E
TU
ND
ISH
EQ
UIP
MEN
T S
YM
BO
LS
LO
W P
RESSU
RE H
OT
WA
TER
ST
OR
AG
E C
ALO
RIFIE
R
IMM
ER
SION
HEA
TER
SEN
TIN
EL O
UT
LET
S1
2
34
56
78
9
1LPH
WSC
ELEC
TR
IC ST
OR
AG
E
CA
LO
RIFIE
R2
ESC
REM
OT
E G
AS
WA
TER
HEA
TER
(CO
MB
I)3
RG
WH
REM
OT
E E
LEC
TR
ICW
AT
ER
HEA
TER
4R
EW
H
INST
AN
TA
NEO
US
HO
T W
AT
ER
HEA
TER
5IH
WH
HY
DR
OB
OIL
6H
B
7
ELEC
TR
IC ST
OR
AG
E
CA
LO
RIFIE
R8
ESC
*
9 - T
- TA
NK
BIB
TA
PB
T
HO
SE R
EEL / F
IRE H
OSE
REEL
HR
/ FH
R
PR
ESS
UR
ISAT
ION
UN
ITPU
WA
TER
SO
FT
EN
ING
PLA
NT
WSP
DIR
EC
T G
AS F
IRED
W
AT
ER
HEA
TER
DG
FW
HD
G
FW
H
RG
WH
VA
LV
E - O
PEN
/ CLO
SED
TM
V / T
T
ROOFGROUND FLOORVOID
MC
WS 1
SV
001
GEN
TS
002
LA
DIE
S
WB
WC
003
AC
CESS
TO
ILET
MT
SK
004
CLEA
NER
S
2x
WB
2x
WC
2x
2x
UC
2x
WB
2x
WC
2x
**
*
ESC
1
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1
2
3
4
5
6
7
1
2
3
4
5
6
7
Scale: NTS Size: A4 Sheet: 1 of 1
REV DATE DESCRIPTION DRAWN CHECKED
0 07-08-2019 INITIAL RELEASE
These drawings must not be copied or
duplicated nor shown to or placed at the
disposal of third person without our written
consent
HW
MCW
=
=
HOT WATER
MAINS COLD WATER
CCW = CISTERN COLD WATER
KEY
FITTINGS
EQUIPMENT
HWR = HOT WATER RETURN
= BLENDED WATERBW
EQUIPMENT SYMBOLS
LOW PRESSURE HOT
WATER
STORAGE CALORIFIER
9
IMMERSION HEATER
SENTINEL OUTLETS
1 2
3 4
6
7 8
9
1 LPHWSC
ELECTRIC STORAGE
CALORIFIER
2 ESC
REMOTE GAS
WATER HEATER (COMBI)
3 RGWH
REMOTE ELECTRIC
WATER HEATER
4 REWH
INSTANTANEOUS
HOT WATER HEATER
5 IHWH
HYDROBOIL6 HB
LOW PRESSURE HOT
WATER STORAGE
CALORIFIER (T)
7
LPHWSC
(T)
ELECTRIC STORAGE
CALORIFIER (T)
8
ESC (T)
DWG. No.:2E6923S295
T
HWBV
SHSV
10
11
12
13 PHE
Tank
HOT WATER BUFFER
VESSEL
10
DGSC
DIRECT FIRED GAS HOT
WATER CYLINDER
SOLAR PRE-HEAT
STORAGE VESSEL
PLATE HEAT
EXCHANGER
11
12
13
BT
BIB TAP
HR HOSE REEL
M
METER
VALVE
TMV
STRAINER
PRV
PRESSURE RELIEF VALVE
PRESSURE GAUGE
PRESSURE VESSEL
NON RETURN VALVE
DOUBLE CHECK VALVE
PUMP
TUNDISH
DEAD LEG
FILTER
DRAIN / SAMPLE POINT
PIPE BREAK
TEMPERATURE GUAGE
WC TOILET
WB WASH HAND BASIN
B BATH
UCT URINAL CISTERN
ELS ELECTRIC SHOWER
MXS MIXER SHOWER
SK SINK
BLS BELFAST SINK
ZEW EMERGENCY EYE WASH
ZS EMERGENCY SHOWER
DW DISH WASHER
WM WASHING MACHINE
S SLUICE
DRM DRINKS MACHINE
DWF
DRINKING WATER
FOUNTAIN
CWF CHILLED WF
SO STEAM OVEN
PU PRESSURIZED UNIT
5
ISOLATED VALVE
FIR
ST
F
LO
OR
GR
OU
ND
F
LO
OR
VO
ID
LO
FT
VO
ID
MCWS 2
(601 PLANT ROOM)
BTSK DWSK
SV
F+E TANK
601
PLANT
ROOM
001
STAFF
ROOM
002
ROOM
03
003 KITCHEN 004
GAMES
ROOM
005
LADIES 1
006
CLEANERS
007
GENTS 1
010 KITCHEN 2 011
ACCESS
TOILET
012
UNISEX
TOILET
013
SHOWER
ROOM
OUTSIDE
SK WB WM SK WB
2x
WC SK WB
2x
WC
008
LADIES 2
WB WC
009
GENTS 2
WB WC SK WCH HB WB WC WB WC WB MXS
SK
015
KITCHEN
3
016
LADIES 3
WB WC
017
GENTS 3
WB WC
018
CLEANERS
SK
T 1
MCWS 1
(101 OUTSIDE FRONT
OF BUILDING)
SV
PHE 1
* *
BT
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1
2
3
4
5
6
7
1
2
3
4
5
6
7
Scale: NTS Size: A4 Sheet: 1 of 1
REV DATE DESCRIPTION DRAWN CHECKED
0 22-08-2019 INITIAL RELEASE
These drawings must not be copied or
duplicated nor shown to or placed at the
disposal of third person without our written
consent
HW
MCW
=
=
HOT WATER
MAINS COLD WATER
CCW = CISTERN COLD WATER
KEY
FITTINGS
EQUIPMENT
HWR = HOT WATER RETURN
= BLENDED WATERBW
EQUIPMENT SYMBOLS
LOW PRESSURE HOT
WATER
STORAGE CALORIFIER
9
IMMERSION HEATER
SENTINEL OUTLETS
1 2
3 4
6
7 8
9
1 LPHWSC
ELECTRIC STORAGE
CALORIFIER
2 ESC
REMOTE GAS
WATER HEATER (COMBI)
3 RGWH
REMOTE ELECTRIC
WATER HEATER
4 REWH
INSTANTANEOUS
HOT WATER HEATER
5 IHWH
HYDROBOIL6 HB
LOW PRESSURE HOT
WATER STORAGE
CALORIFIER (T)
7
LPHWSC
(T)
ELECTRIC STORAGE
CALORIFIER (T)
8
ESC (T)
DWG. No.:1E6925S322
T
HWBV
SHSV
10
11
12
13 PHE
Tank
HOT WATER BUFFER
VESSEL
10
DGSC
DIRECT FIRED GAS HOT
WATER CYLINDER
SOLAR PRE-HEAT
STORAGE VESSEL
PLATE HEAT
EXCHANGER
11
12
13
BT
BIB TAP
HR HOSE REEL
M
METER
VALVE
TMV
STRAINER
PRV
PRESSURE RELIEF VALVE
PRESSURE GAUGE
PRESSURE VESSEL
NON RETURN VALVE
DOUBLE CHECK VALVE
PUMP
TUNDISH
DEAD LEG
FILTER
DRAIN / SAMPLE POINT
PIPE BREAK
TEMPERATURE GUAGE
WC TOILET
WB WASH HAND BASIN
B BATH
UCT URINAL CISTERN
ELS ELECTRIC SHOWER
MXS MIXER SHOWER
SK SINK
BLS BELFAST SINK
ZEW EMERGENCY EYE WASH
ZS EMERGENCY SHOWER
DW DISH WASHER
WM WASHING MACHINE
S SLUICE
DRM DRINKS MACHINE
DWF
DRINKING WATER
FOUNTAIN
CWF CHILLED WF
SO STEAM OVEN
PU PRESSURIZED UNIT
5
ISOLATED VALVE
FIR
ST
F
LO
OR
GR
OU
ND
F
LO
OR
VO
ID
LO
FT
VO
ID
MCWS 1
(001 BOYS)
002
GIRLS
001
BOYS
003
ACCESSIBLE
TOILET
004
CLASSROOM
SV
BLOCK 1
M
REWH 2
DL
UCT
WCWBWB WC
2x
WC
2x
WB
3x
WC
2x
WB
005
STAFF
TOILET
006
CORRIDOR
007
OUTSIDE
REWH 1
2x
SKBT
LPHWSC 1
FIR
ST
F
LO
OR
LO
FT
VO
ID
BLOCK 2
LPHWSC 2
REWH 3
001
KITCHEN
WBSK WB
SK
002
CLASSROOM
SK
003
CLASSROOM
004
OUTSIDE
BT
501
LOFT
* *
*
*
*
MCWS 1
(003 CLASSROOM)
SV
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1
2
3
4
5
6
7
1
2
3
4
5
6
7
Scale: NTS Size: A4 Sheet: 1 of 1
REV DATE DESCRIPTION DRAWN CHECKED
0 28/08/2019 INITIAL RELEASE
These drawings must not be copied or
duplicated nor shown to or placed at the
disposal of third person without our written
consent
HW
MCW
=
=
HOT WATER
MAINS COLD WATER
CCW = CISTERN COLD WATER
KEY
FITTINGS
EQUIPMENT
HWR = HOT WATER RETURN
= BLENDED WATERBW
EQUIPMENT SYMBOLS
LOW PRESSURE HOT
WATER
STORAGE CALORIFIER
9
IMMERSION HEATER
SENTINEL OUTLETS*
1 2
3 4
6
7 8
9
1 LPHWSC
ELECTRIC STORAGE
CALORIFIER
2 ESC
REMOTE GAS
WATER HEATER (COMBI)
3 RGWH
REMOTE ELECTRIC
WATER HEATER
4 REWH
INSTANTANEOUS
HOT WATER HEATER
5 IHWH
HYDROBOIL6 HB
LOW PRESSURE HOT
WATER STORAGE
CALORIFIER (T)
7
LPHWSC
(T)
ELECTRIC STORAGE
CALORIFIER (T)
8
ESC (T)
DWG. No.: 2E6920S330
T
HWBV
SHSV
10
11
12
13 PHE
Tank
HOT WATER BUFFER
VESSEL
10
DGSC
DIRECT FIRED GAS HOT
WATER CYLINDER
SOLAR PRE-HEAT
STORAGE VESSEL
PLATE HEAT
EXCHANGER
11
12
13
BT
BIB TAP
HR HOSE REEL
M
METER
VALVE
TMV
STRAINER
PRV
PRESSURE RELIEF VALVE
PRESSURE GAUGE
PRESSURE VESSEL
NON RETURN VALVE
DOUBLE CHECK VALVE
PUMP
TUNDISH
DEAD LEG
FILTER
DRAIN / SAMPLE POINT
PIPE BREAK
TEMPERATURE GUAGE
WC TOILET
WB WASH HAND BASIN
B BATH
UCT URINAL CISTERN
ELS ELECTRIC SHOWER
MXS MIXER SHOWER
SK SINK
BLS BELFAST SINK
ZEW EMERGENCY EYE WASH
ZS EMERGENCY SHOWER
DW DISH WASHER
WM WASHING MACHINE
S SLUICE
DRM DRINKS MACHINE
DWF
DRINKING WATER
FOUNTAIN
CWF CHILLED WF
SO STEAM OVEN
PU PRESSURIZED UNIT
5
ISOLATED VALVE
FIR
ST
F
LO
OR
GR
OU
ND
F
LO
OR
VO
ID
LO
FT
VO
ID
MCWS 1
(006 ACCESS/
STAFF TOILET)
T 1
SV
VENT
MAIN BUILDING
SK
001
CLASSROOM
002
CLEANERS
REWH 1 SKREWH 2 SKREWH 3
003
GIRLS
ESC 1
4x
WB
TO
TUNDISH
* *
4x
WC
004
BOYS
4x
WB
*
2x
WC UCT
005
CORRIDOR
WCH
006
ACCESS/STAFF
TOILET
WCWB
007
STAFF
ROOM
SK
008
KITCHEN
ESC 3
TO
VENT
WB SK SK
* * *N *F
009
KITCHEN
STORE
WM
010
KITCHEN
TOILET
WCWB
011
KITCHEN
CLEANERS
SK
* *
MCWS 2
(011 KITCHEN
CLEANERS)
SV
501
CORRIDOR
LOFT
ESC 2
TO
VENT
T 2
VENT
502
KITCHEN
LOFT
012
OUTSIDE
BT
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1
2
3
4
5
6
7
1
2
3
4
5
6
7
Scale: NTS Size: A4 Sheet: 1 of 2
REV DATE DESCRIPTION DRAWN CHECKED
0 07-08-2019 INITIAL RELEASE
These drawings must not be copied or
duplicated nor shown to or placed at the
disposal of third person without our written
consent
HW
MCW
=
=
HOT WATER
MAINS COLD WATER
CCW = CISTERN COLD WATER
KEY
FITTINGS
EQUIPMENT
HWR = HOT WATER RETURN
= BLENDED WATERBW
EQUIPMENT SYMBOLS
LOW PRESSURE HOT
WATER
STORAGE CALORIFIER
9
IMMERSION HEATER
SENTINEL OUTLETS*
1 2
3 4
6
7 8
9
1 LPHWSC
ELECTRIC STORAGE
CALORIFIER
2 ESC
REMOTE GAS
WATER HEATER (COMBI)
3 RGWH
REMOTE ELECTRIC
WATER HEATER
4 REWH
INSTANTANEOUS
HOT WATER HEATER
5 IHWH
HYDROBOIL6 HB
LOW PRESSURE HOT
WATER STORAGE
CALORIFIER (T)
7
LPHWSC
(T)
ELECTRIC STORAGE
CALORIFIER (T)
8
ESC (T)
DWG. No.: 4E6924S295
T
HWBV
SHSV
10
11
12
13 PHE
Tank
HOT WATER BUFFER
VESSEL
10
DGSC
DIRECT FIRED GAS HOT
WATER CYLINDER
SOLAR PRE-HEAT
STORAGE VESSEL
PLATE HEAT
EXCHANGER
11
12
13
BT
BIB TAP
HR HOSE REEL
M
METER
VALVE
TMV
STRAINER
PRV
PRESSURE RELIEF VALVE
PRESSURE GAUGE
PRESSURE VESSEL
NON RETURN VALVE
DOUBLE CHECK VALVE
PUMP
TUNDISH
DEAD LEG
FILTER
DRAIN / SAMPLE POINT
PIPE BREAK
TEMPERATURE GUAGE
WC TOILET
WB WASH HAND BASIN
B BATH
UCT URINAL CISTERN
ELS ELECTRIC SHOWER
MXS MIXER SHOWER
SK SINK
BLS BELFAST SINK
ZEW EMERGENCY EYE WASH
ZS EMERGENCY SHOWER
DW DISH WASHER
WM WASHING MACHINE
S SLUICE
DRM DRINKS MACHINE
DWF
DRINKING WATER
FOUNTAIN
CWF CHILLED WF
SO STEAM OVEN
PU PRESSURIZED UNIT
5
ISOLATED VALVE
GR
OU
ND
F
LO
OR
BA
SE
ME
NT
VO
ID
VO
ID
MCWS 1
(UNDER STAGE)
FIR
ST
F
LO
OR
VO
ID
SV
BLOCK 1
VO
ID
101
UNDER
STAGE
001
ROOM 5
WB SK DW WTB CWF
002
ROOM 6
SK
003
ROOM 12
SK
004
ROOM 11
SK
601
PLANT ROOM
T 1
VENT
LPHWSC 1
MCWS 2
(GF-KITCHEN)
SV
005
ROOM 1
2x
WB WB SKDW
006
INFANTS TOILET
TROUGH
007
ROOM
2
WB SK
008
GIRLS
6x
WB
8x
WC
009
ROOM
3
WB
010
BOYS
6x
WB
6x
4x
WC UCT
011
ROOM
4
WB
012
GIRLS
8x
WB
8x
8x
WC
013
ACCESS
TOILET
WB ELS WC
014
THE
BASE
SK DW
015
BOYS
8x
WB
4x
WC
2x
UCT
016
CORRI-
DOR
WCH
017
STAFF
ROOM
SK DW
018
STAFF
GENTS
WB WC
019
STAFF
LADIES
WB
2x
WC
020
FIRST AID
ROOM
SK
021 HEAD
TEACHERS
TOILET
WB WC
022
KITCHEN
WB SK MXS
2x
SO DW
SPRAY
RINSE
027
ROOM 13
SK
028
ROOM 8
SK
029
ROOM 7
SK
A B C D E
*
* *
2x
F
G
H
BT
*
3x
WC
TROUGH
TH
IR
D F
LO
OR
SE
CO
ND
F
LO
OR
VO
ID
LO
FT
VO
ID
BLOCK 1
030
ROOM 9
SK
031
ROOM 10
SK
033
ROOM 15
SK
032
ROOM 16
SK
501
TANK ROOM
T2
A B C D E
**
GR
OU
ND
F
LO
OR
BA
SE
ME
NT
VO
ID
VO
ID
FIR
ST
F
LO
OR
VO
ID
BLOCK 1
VO
ID
023
CLEANERS
SK
024
FOOD PREP
AREA
SK PPWM BT
025
KITCHEN
TOILET
WB WC
026
OUTSIDE
BT
ESC 2
REWH 1
* *
F
G
H
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1
2
3
4
5
6
7
1
2
3
4
5
6
7
Scale: NTS Size: A4 Sheet: 2 of 2
REV DATE DESCRIPTION DRAWN CHECKED
0 07-08-2019 INITIAL RELEASE
These drawings must not be copied or
duplicated nor shown to or placed at the
disposal of third person without our written
consent
HW
MCW
=
=
HOT WATER
MAINS COLD WATER
CCW = CISTERN COLD WATER
KEY
FITTINGS
EQUIPMENT
HWR = HOT WATER RETURN
= BLENDED WATERBW
EQUIPMENT SYMBOLS
LOW PRESSURE HOT
WATER
STORAGE CALORIFIER
9
IMMERSION HEATER
SENTINEL OUTLETS
1 2
3 4
6
7 8
9
1 LPHWSC
ELECTRIC STORAGE
CALORIFIER
2 ESC
REMOTE GAS
WATER HEATER (COMBI)
3 RGWH
REMOTE ELECTRIC
WATER HEATER
4 REWH
INSTANTANEOUS
HOT WATER HEATER
5 IHWH
HYDROBOIL6 HB
LOW PRESSURE HOT
WATER STORAGE
CALORIFIER (T)
7
LPHWSC
(T)
ELECTRIC STORAGE
CALORIFIER (T)
8
ESC (T)
DWG. No.: 4E6924S295
T
HWBV
SHSV
10
11
12
13 PHE
Tank
HOT WATER BUFFER
VESSEL
10
DGSC
DIRECT FIRED GAS HOT
WATER CYLINDER
SOLAR PRE-HEAT
STORAGE VESSEL
PLATE HEAT
EXCHANGER
11
12
13
BT
BIB TAP
HR HOSE REEL
M
METER
VALVE
TMV
STRAINER
PRV
PRESSURE RELIEF VALVE
PRESSURE GAUGE
PRESSURE VESSEL
NON RETURN VALVE
DOUBLE CHECK VALVE
PUMP
TUNDISH
DEAD LEG
FILTER
DRAIN / SAMPLE POINT
PIPE BREAK
TEMPERATURE GUAGE
WC TOILET
WB WASH HAND BASIN
B BATH
UCT URINAL CISTERN
ELS ELECTRIC SHOWER
MXS MIXER SHOWER
SK SINK
BLS BELFAST SINK
ZEW EMERGENCY EYE WASH
ZS EMERGENCY SHOWER
DW DISH WASHER
WM WASHING MACHINE
S SLUICE
DRM DRINKS MACHINE
DWF
DRINKING WATER
FOUNTAIN
CWF CHILLED WF
SO STEAM OVEN
PU PRESSURIZED UNIT
5
ISOLATED VALVE
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1
2
3
4
5
6
7
1
2
3
4
5
6
7
Scale: NTS Size: A4 Sheet: 1 of 4
REV DATE DESCRIPTION DRAWN CHECKED
0 27-09-2019 INITIAL RELEASE
These drawings must not be copied or
duplicated nor shown to or placed at the
disposal of third person without our written
consent
HW
MCW
=
=
HOT WATER
MAINS COLD WATER
CCW = CISTERN COLD WATER
KEY
FITTINGS
EQUIPMENT
HWR = HOT WATER RETURN
= BLENDED WATERBW
EQUIPMENT SYMBOLS
LOW PRESSURE HOT
WATER
STORAGE CALORIFIER
9
IMMERSION HEATER
SENTINEL OUTLETS
1 2
3 4
6
7 8
9
1 LPHWSC
ELECTRIC STORAGE
CALORIFIER
2 ESC
REMOTE GAS
WATER HEATER (COMBI)
3 RGWH
REMOTE ELECTRIC
WATER HEATER
4 REWH
INSTANTANEOUS
HOT WATER HEATER
5 IHWH
HYDROBOIL6 HB
LOW PRESSURE HOT
WATER STORAGE
CALORIFIER (T)
7
LPHWSC
(T)
ELECTRIC STORAGE
CALORIFIER (T)
8
ESC (T)
DWG. No.: 1E6419S369
T
HWBV
SHSV
10
11
12
13 PHE
Tank
HOT WATER BUFFER
VESSEL
10
DGSC
DIRECT FIRED GAS HOT
WATER CYLINDER
SOLAR PRE-HEAT
STORAGE VESSEL
PLATE HEAT
EXCHANGER
11
12
13
BT
BIB TAP
HR HOSE REEL
M
METER
VALVE
TMV
STRAINER
PRV
PRESSURE RELIEF VALVE
PRESSURE GAUGE
PRESSURE VESSEL
NON RETURN VALVE
DOUBLE CHECK VALVE
PUMP
TUNDISH
DEAD LEG
FILTER
DRAIN / SAMPLE POINT
PIPE BREAK
TEMPERATURE GUAGE
WC TOILET
WB WASH HAND BASIN
B BATH
UCT URINAL CISTERN
ELS ELECTRIC SHOWER
MXS MIXER SHOWER
SK SINK
BLS BELFAST SINK
ZEW EMERGENCY EYE WASH
ZS EMERGENCY SHOWER
DW DISH WASHER
WM WASHING MACHINE
S SLUICE
DRM DRINKS MACHINE
DWF
DRINKING WATER
FOUNTAIN
CWF CHILLED WF
SO STEAM OVEN
PU PRESSURIZED UNIT
5
ISOLATED VALVE
*
602 LOFT BY MAIN KITCHEN
LPHWSC 2
063
ROOM
41
SK
064
ROOM
175
SK
065
ROOM
174
SK
066
STAFF
BASE
SK
067
ROOM
170
SK
068
CLEANERS
SK
069
STAFF
GENTS
**
WB
070
STAFF
LADIES
WC WB WC
071
STAFF
LADIES
072
STAFF
GENTS
WCWB
*
WCWB
T 2
VENT
502 LOFT BY
MAIN KITCHEN
(ON SECOND FLOOR)
T 3
VENT
503 ROOF SPACE
BY ROOM 068
T 4
504 ROOF SPACE
BY ROOM 072
LPHWSC 3
VENT
LPHWSC 4
VENT
073
ROOM
151
REWH 1SK
074
ROOM
150
2x
SK
075
ROOM
153
BTREWH 2
SK
2x
SK
076
ROOM
155
REWH 3SK
2x
SK
077
ROOM
156
REWH 4SK SKSK
078
GREEN
HOUSE
BT
079
STAFF
CUPBOARD
SK
080
ROOM
154
SKFC
081
ROOM
152
REWH 5SKSK
REWH 6SK
2x
SK
MCWS 1
(601-PALNT ROOM)
SV
601
PLANT ROOM
001
MUSIC BASE
001A KITCHEN
DINING ROOM
002
MAIN KITCHEN
003
KITCHEN
TOILET
004
KITCHEN
CLEANERS
005 PE STAFF
UNISEX TOILET
006
CLEANERS
007 GIRLS
CHANGING ROOM
008 BOYS
CHANGING ROOM
009
JANITORS
010
STAFF GENTS
VO
ID
GR
OU
ND
F
LO
OR
FIR
ST
F
LO
OR
VO
ID
LO
FT
LPHWSC 1
PU
DL
SK DWF WB DW
4x
SK SO WDU WM HB WB WC SK WB MXS WC SK
2x
WB WB
3x
MXS
2x
WC
2x
WB WB
3x
MXS WC
2x
UCT SK
3x
WB WC
2x
UCT
** ** **
T 1
VENT
501 LOFT ABOVE PLANT ROOM
A
B
C
D
E
F
G
H
I
BLOCK 1
W
X
Y
TO
0
84
CL
EA
NE
RS
T 5
VENT
505 ROOF SPACE ABOVE
082
STAFF
AREA
REWH 7
083
STAFF
AREA
SK
084
CLEANERS
SK
*
084
STAFF
LADIES
WB WC
085
STAFF
GENTS
WB WC
603
CUPBOARD
LPHWSC 5
VENT
086
ROOM
131
SK
087
ROOM
132
3x
SK
088
ROOM
133
3x
SK
089
ROOM
134
3x
SK
090
STAFF
BASE
SK
011
STAFF LADIES
012
STAFF ROOM
013
GIRLS
014
CLEANERS
015
CORRIDOR
016
BOYS
017
ROOM 165
018
ENGLISH
STAFF BASE
019
ACCESS
TOILET
020
STAFF GENTS
021
STAFF LADIES
022
GIRLS
023
CLEANERS
024
BOYS
025
ROOM 40
027
STAFF GENTS
026
STAFF LADIES
3x
WB
3x
WC SK HB
4x
WB
4x
WC SK DWF
3x
WB
2x
WC
3x
UCT SK
**
SK WB WC WB WC WB WC
5x
WB
3x
WC SK
5x
WB
3x
WC
3x
UCT WB SK WB WC WB WC
VO
ID
GR
OU
ND
F
LO
OR
FIR
ST
F
LO
OR
VO
ID
LO
FT
**
A
B
C
D
F
G
E
H
I
J
K
L
M
N
O
BLOCK 1
W
X
Y
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1
2
3
4
5
6
7
1
2
3
4
5
6
7
Scale: NTS Size: A4 Sheet: 2 of 4
REV DATE DESCRIPTION DRAWN CHECKED
0 27-09-2019 INITIAL RELEASE
These drawings must not be copied or
duplicated nor shown to or placed at the
disposal of third person without our written
consent
HW
MCW
=
=
HOT WATER
MAINS COLD WATER
CCW = CISTERN COLD WATER
KEY
FITTINGS
EQUIPMENT
HWR = HOT WATER RETURN
= BLENDED WATERBW
EQUIPMENT SYMBOLS
LOW PRESSURE HOT
WATER
STORAGE CALORIFIER
9
IMMERSION HEATER
SENTINEL OUTLETS
1 2
3 4
6
7 8
9
1 LPHWSC
ELECTRIC STORAGE
CALORIFIER
2 ESC
REMOTE GAS
WATER HEATER (COMBI)
3 RGWH
REMOTE ELECTRIC
WATER HEATER
4 REWH
INSTANTANEOUS
HOT WATER HEATER
5 IHWH
HYDROBOIL6 HB
LOW PRESSURE HOT
WATER STORAGE
CALORIFIER (T)
7
LPHWSC
(T)
ELECTRIC STORAGE
CALORIFIER (T)
8
ESC (T)
DWG. No.: 1E6419S369
T
HWBV
SHSV
10
11
12
13 PHE
Tank
HOT WATER BUFFER
VESSEL
10
DGSC
DIRECT FIRED GAS HOT
WATER CYLINDER
SOLAR PRE-HEAT
STORAGE VESSEL
PLATE HEAT
EXCHANGER
11
12
13
BT
BIB TAP
HR HOSE REEL
M
METER
VALVE
TMV
STRAINER
PRV
PRESSURE RELIEF VALVE
PRESSURE GAUGE
PRESSURE VESSEL
NON RETURN VALVE
DOUBLE CHECK VALVE
PUMP
TUNDISH
DEAD LEG
FILTER
DRAIN / SAMPLE POINT
PIPE BREAK
TEMPERATURE GUAGE
WC TOILET
WB WASH HAND BASIN
B BATH
UCT URINAL CISTERN
ELS ELECTRIC SHOWER
MXS MIXER SHOWER
SK SINK
BLS BELFAST SINK
ZEW EMERGENCY EYE WASH
ZS EMERGENCY SHOWER
DW DISH WASHER
WM WASHING MACHINE
S SLUICE
DRM DRINKS MACHINE
DWF
DRINKING WATER
FOUNTAIN
CWF CHILLED WF
SO STEAM OVEN
PU PRESSURIZED UNIT
5
ISOLATED VALVE
*
AA
AB
Z
* *
FROM
FROM T 4
046
WORKSHOP
CLASSROOM 123
SK
045
WORKSHOPS
SK
**
SK
044
ACCESS
TOILET
WB WC
043
GENTS
STAFF
WB WC
042
LADIES
STAFF
041
ROOM
31
SK
040
STAFF
BASE
SK
**
039
TECHNICIANS
ROOM
SK
038
ROOM
32
SK
028
CLEANERS
029
CORRIDOR
030
ROOM 144
031
STAFF AREA
032
UTENSIL
AREA
033
ROOM 145
034
ROOM 146
035
MODERN STAFF
LANGUAGES BASE
036
ACCESS
TOILET
037 ACCESS
SHOWER
ROOM
SK DWF WB
10x
SK SK DW DW
2x
WM WB
11x
SK WB SK WB WC ELS
VO
ID
GR
OU
ND
F
LO
OR
FIR
ST
F
LO
OR
VO
ID
LO
FT
J
K
L
M
N
O
P
Q
R
S
T
U
V
BLOCK 1
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1
2
3
4
5
6
7
1
2
3
4
5
6
7
Scale: NTS Size: A4 Sheet: 3 of 4
REV DATE DESCRIPTION DRAWN CHECKED
0 27-09-2019 INITIAL RELEASE
These drawings must not be copied or
duplicated nor shown to or placed at the
disposal of third person without our written
consent
HW
MCW
=
=
HOT WATER
MAINS COLD WATER
CCW = CISTERN COLD WATER
KEY
FITTINGS
EQUIPMENT
HWR = HOT WATER RETURN
= BLENDED WATERBW
EQUIPMENT SYMBOLS
LOW PRESSURE HOT
WATER
STORAGE CALORIFIER
9
IMMERSION HEATER
SENTINEL OUTLETS
1 2
3 4
6
7 8
9
1 LPHWSC
ELECTRIC STORAGE
CALORIFIER
2 ESC
REMOTE GAS
WATER HEATER (COMBI)
3 RGWH
REMOTE ELECTRIC
WATER HEATER
4 REWH
INSTANTANEOUS
HOT WATER HEATER
5 IHWH
HYDROBOIL6 HB
LOW PRESSURE HOT
WATER STORAGE
CALORIFIER (T)
7
LPHWSC
(T)
ELECTRIC STORAGE
CALORIFIER (T)
8
ESC (T)
DWG. No.: 1E6419S369
T
HWBV
SHSV
10
11
12
13 PHE
Tank
HOT WATER BUFFER
VESSEL
10
DGSC
DIRECT FIRED GAS HOT
WATER CYLINDER
SOLAR PRE-HEAT
STORAGE VESSEL
PLATE HEAT
EXCHANGER
11
12
13
BT
BIB TAP
HR HOSE REEL
M
METER
VALVE
TMV
STRAINER
PRV
PRESSURE RELIEF VALVE
PRESSURE GAUGE
PRESSURE VESSEL
NON RETURN VALVE
DOUBLE CHECK VALVE
PUMP
TUNDISH
DEAD LEG
FILTER
DRAIN / SAMPLE POINT
PIPE BREAK
TEMPERATURE GUAGE
WC TOILET
WB WASH HAND BASIN
B BATH
UCT URINAL CISTERN
ELS ELECTRIC SHOWER
MXS MIXER SHOWER
SK SINK
BLS BELFAST SINK
ZEW EMERGENCY EYE WASH
ZS EMERGENCY SHOWER
DW DISH WASHER
WM WASHING MACHINE
S SLUICE
DRM DRINKS MACHINE
DWF
DRINKING WATER
FOUNTAIN
CWF CHILLED WF
SO STEAM OVEN
PU PRESSURIZED UNIT
5
ISOLATED VALVE
*
AA
AB
Z
*
WB WC
MCWS 2 (604 PLANT ROOM)
SV
BLOCK 1
M
VO
ID
GR
OU
ND
F
LO
OR
FIR
ST
F
LO
OR
VO
ID
LO
FT
058 LEARNING
CENTRE
LADIES
3x
WB
3x
WC
059 LEARNING
CENTRE
ACCESS TOILET
WB WC
*
MXS
060 LEARNING
CENTRE LADIES
CHANGE ROOM
MXS
061 LEARNING
CENTRE
FITNESS SUITE
WCH
062 LEARNING
CENTRE GENTS
CHANGE ROOM
MXS
604 LEARNING
CENTRE
PLANT ROOM
LPHWSC 6
PU
057 LEARNING
CENTRE
GENTS
2x
WB WC
2x
UCT
056
STAFF
GENTS
2x
WB WC
2x
UCT
055
STAFF
LADIES
WB WC
054
TOILETS
2x
WB
2x
WC
053
GUIDASCE
BASE
WB
052
ROOM
30
WB
051
GIRLS
4x
WB
4x
WC
050
CORRIDOR
049
CLEANERS
SK DWF
048
BOYS
3x
WB
2x
WC
3x
UCT
047
STORE
SK
P
Q
R
S
T
U
V
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1
2
3
4
5
6
7
1
2
3
4
5
6
7
Scale: NTS Size: A4 Sheet: 4 of 4
REV DATE DESCRIPTION DRAWN CHECKED
0 27-09-2019 INITIAL RELEASE
These drawings must not be copied or
duplicated nor shown to or placed at the
disposal of third person without our written
consent
HW
MCW
=
=
HOT WATER
MAINS COLD WATER
CCW = CISTERN COLD WATER
KEY
FITTINGS
EQUIPMENT
HWR = HOT WATER RETURN
= BLENDED WATERBW
EQUIPMENT SYMBOLS
LOW PRESSURE HOT
WATER
STORAGE CALORIFIER
9
IMMERSION HEATER
SENTINEL OUTLETS
1 2
3 4
6
7 8
9
1 LPHWSC
ELECTRIC STORAGE
CALORIFIER
2 ESC
REMOTE GAS
WATER HEATER (COMBI)
3 RGWH
REMOTE ELECTRIC
WATER HEATER
4 REWH
INSTANTANEOUS
HOT WATER HEATER
5 IHWH
HYDROBOIL6 HB
LOW PRESSURE HOT
WATER STORAGE
CALORIFIER (T)
7
LPHWSC
(T)
ELECTRIC STORAGE
CALORIFIER (T)
8
ESC (T)
DWG. No.: 1E6419S369
T
HWBV
SHSV
10
11
12
13 PHE
Tank
HOT WATER BUFFER
VESSEL
10
DGSC
DIRECT FIRED GAS HOT
WATER CYLINDER
SOLAR PRE-HEAT
STORAGE VESSEL
PLATE HEAT
EXCHANGER
11
12
13
BT
BIB TAP
HR HOSE REEL
M
METER
VALVE
TMV
STRAINER
PRV
PRESSURE RELIEF VALVE
PRESSURE GAUGE
PRESSURE VESSEL
NON RETURN VALVE
DOUBLE CHECK VALVE
PUMP
TUNDISH
DEAD LEG
FILTER
DRAIN / SAMPLE POINT
PIPE BREAK
TEMPERATURE GUAGE
WC TOILET
WB WASH HAND BASIN
B BATH
UCT URINAL CISTERN
ELS ELECTRIC SHOWER
MXS MIXER SHOWER
SK SINK
BLS BELFAST SINK
ZEW EMERGENCY EYE WASH
ZS EMERGENCY SHOWER
DW DISH WASHER
WM WASHING MACHINE
S SLUICE
DRM DRINKS MACHINE
DWF
DRINKING WATER
FOUNTAIN
CWF CHILLED WF
SO STEAM OVEN
PU PRESSURIZED UNIT
5
ISOLATED VALVE
*
2x
WC
*
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1
2
3
4
5
6
7
1
2
3
4
5
6
7
Scale: NTS Size: A4 Sheet: 1 of 2
REV DATE DESCRIPTION DRAWN CHECKED
0 28-08-2019 INITIAL RELEASE
These drawings must not be copied or
duplicated nor shown to or placed at the
disposal of third person without our written
consent
HW
MCW
=
=
HOT WATER
MAINS COLD WATER
CCW = CISTERN COLD WATER
KEY
FITTINGS
EQUIPMENT
HWR = HOT WATER RETURN
= BLENDED WATERBW
EQUIPMENT SYMBOLS
LOW PRESSURE HOT
WATER
STORAGE CALORIFIER
9
IMMERSION HEATER
SENTINEL OUTLETS
1 2
3 4
6
7 8
9
1 LPHWSC
ELECTRIC STORAGE
CALORIFIER
2 ESC
REMOTE GAS
WATER HEATER (COMBI)
3 RGWH
REMOTE ELECTRIC
WATER HEATER
4 REWH
INSTANTANEOUS
HOT WATER HEATER
5 IHWH
HYDROBOIL6 HB
LOW PRESSURE HOT
WATER STORAGE
CALORIFIER (T)
7
LPHWSC
(T)
ELECTRIC STORAGE
CALORIFIER (T)
8
ESC (T)
DWG. No.: 1E6921S330
T
HWBV
SHSV
10
11
12
13 PHE
Tank
HOT WATER BUFFER
VESSEL
10
DGSC
DIRECT FIRED GAS HOT
WATER CYLINDER
SOLAR PRE-HEAT
STORAGE VESSEL
PLATE HEAT
EXCHANGER
11
12
13
BT
BIB TAP
HR HOSE REEL
M
METER
VALVE
TMV
STRAINER
PRV
PRESSURE RELIEF VALVE
PRESSURE GAUGE
PRESSURE VESSEL
NON RETURN VALVE
DOUBLE CHECK VALVE
PUMP
TUNDISH
DEAD LEG
FILTER
DRAIN / SAMPLE POINT
PIPE BREAK
TEMPERATURE GUAGE
WC TOILET
WB WASH HAND BASIN
B BATH
UCT URINAL CISTERN
ELS ELECTRIC SHOWER
MXS MIXER SHOWER
SK SINK
BLS BELFAST SINK
ZEW EMERGENCY EYE WASH
ZS EMERGENCY SHOWER
DW DISH WASHER
WM WASHING MACHINE
S SLUICE
DRM DRINKS MACHINE
DWF
DRINKING WATER
FOUNTAIN
CWF CHILLED WF
SO STEAM OVEN
PU PRESSURIZED UNIT
5
ISOLATED VALVE
FIR
ST
F
LO
OR
GR
OU
ND
F
LO
OR
VO
ID
LO
FT
VO
ID
MAIN BUILDING
3x
WB
001
NURSERY
TOILET
REWH 1
MCWS 1
(101 OUTSIDE
FRONT CAFE)
SV
101
OUTSIDE
FRONT
CAFE2x
WC
002
NURSERY
REWH 2 WB
003
NURSERY
KITCHEN
REWH 3 SK
004
JANITORS
005
PRIMARY
5/6
006
ROOM 9
007
BOYS
601
BOYS
CUPBOARD
008
ROOM 7
009
CLASSROOM
PRIMARY 4
010
STAFF
LADIES
011
STAFF
GENTS
012
STAFF
ROOM
602
GIRLS
CUPBOARD
REWH 4
SK
IHWH 5
SK
IHWH 6
SK
IHWH 9 IHWH 11
SK
IHWH 10
WB
IHWH 8
SK
2x
WB
7x
WB
3x
WC
6x
UCT
ESC 1
T 1
*
IHWH 7
SK
2x
WB WB
3x
WC WC DW
ESC 1
T 2
A
B
DL
014
ROOM 3
015
ROOM 2
017
CORRDOR
603 019
KITCHEN
TOILET
020
KITCHEN
OFFICE
FIR
ST
F
LO
OR
GR
OU
ND
F
LO
OR
VO
ID
LO
FT
VO
ID
MAIN BUILDING
013
GIRLS
7x
WB
8x
WC
*
A
B
SK SK
*
016
ROOM 1
IHWH 12
SK
ESC 3
SK
*
018
KITCHEN
ESC 4
WBBT
2x
SK MXS DW PP
* *
WB WC
* *
501 LOFT
ABOVE KITCHEN
OFFICE
WM
* *
021
DINING
ROOM
WB
022
OUTSIDE
BT
T 3
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1
2
3
4
5
6
7
1
2
3
4
5
6
7
Scale: NTS Size: A4 Sheet: 2 of 2
REV DATE DESCRIPTION DRAWN CHECKED
0 28-08-2019 INITIAL RELEASE
These drawings must not be copied or
duplicated nor shown to or placed at the
disposal of third person without our written
consent
HW
MCW
=
=
HOT WATER
MAINS COLD WATER
CCW = CISTERN COLD WATER
KEY
FITTINGS
EQUIPMENT
HWR = HOT WATER RETURN
= BLENDED WATERBW
EQUIPMENT SYMBOLS
LOW PRESSURE HOT
WATER
STORAGE CALORIFIER
9
IMMERSION HEATER
SENTINEL OUTLETS
1 2
3 4
6
7 8
9
1 LPHWSC
ELECTRIC STORAGE
CALORIFIER
2 ESC
REMOTE GAS
WATER HEATER (COMBI)
3 RGWH
REMOTE ELECTRIC
WATER HEATER
4 REWH
INSTANTANEOUS
HOT WATER HEATER
5 IHWH
HYDROBOIL6 HB
LOW PRESSURE HOT
WATER STORAGE
CALORIFIER (T)
7
LPHWSC
(T)
ELECTRIC STORAGE
CALORIFIER (T)
8
ESC (T)
DWG. No.: 1E6921S330
T
HWBV
SHSV
10
11
12
13 PHE
Tank
HOT WATER BUFFER
VESSEL
10
DGSC
DIRECT FIRED GAS HOT
WATER CYLINDER
SOLAR PRE-HEAT
STORAGE VESSEL
PLATE HEAT
EXCHANGER
11
12
13
BT
BIB TAP
HR HOSE REEL
M
METER
VALVE
TMV
STRAINER
PRV
PRESSURE RELIEF VALVE
PRESSURE GAUGE
PRESSURE VESSEL
NON RETURN VALVE
DOUBLE CHECK VALVE
PUMP
TUNDISH
DEAD LEG
FILTER
DRAIN / SAMPLE POINT
PIPE BREAK
TEMPERATURE GUAGE
WC TOILET
WB WASH HAND BASIN
B BATH
UCT URINAL CISTERN
ELS ELECTRIC SHOWER
MXS MIXER SHOWER
SK SINK
BLS BELFAST SINK
ZEW EMERGENCY EYE WASH
ZS EMERGENCY SHOWER
DW DISH WASHER
WM WASHING MACHINE
S SLUICE
DRM DRINKS MACHINE
DWF
DRINKING WATER
FOUNTAIN
CWF CHILLED WF
SO STEAM OVEN
PU PRESSURIZED UNIT
5
ISOLATED VALVE
WCH
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1
2
3
4
5
6
7
1
2
3
4
5
6
7
Scale: NTS Size: A4 Sheet: 1 of 1
REV DATE DESCRIPTION DRAWN CHECKED
0 27-09-2019 INITIAL RELEASE
These drawings must not be copied or
duplicated nor shown to or placed at the
disposal of third person without our written
consent
HW
MCW
=
=
HOT WATER
MAINS COLD WATER
CCW = CISTERN COLD WATER
KEY
FITTINGS
EQUIPMENT
HWR = HOT WATER RETURN
= BLENDED WATERBW
EQUIPMENT SYMBOLS
LOW PRESSURE HOT
WATER
STORAGE CALORIFIER
9
IMMERSION HEATER
SENTINEL OUTLETS
1 2
3 4
6
7 8
9
1 LPHWSC
ELECTRIC STORAGE
CALORIFIER
2 ESC
REMOTE GAS
WATER HEATER (COMBI)
3 RGWH
REMOTE ELECTRIC
WATER HEATER
4 REWH
INSTANTANEOUS
HOT WATER HEATER
5 IHWH
HYDROBOIL6 HB
LOW PRESSURE HOT
WATER STORAGE
CALORIFIER (T)
7
LPHWSC
(T)
ELECTRIC STORAGE
CALORIFIER (T)
8
ESC (T)
DWG. No.: 2E6665S372
T
HWBV
SHSV
10
11
12
13 PHE
Tank
HOT WATER BUFFER
VESSEL
10
DGSC
DIRECT FIRED GAS HOT
WATER CYLINDER
SOLAR PRE-HEAT
STORAGE VESSEL
PLATE HEAT
EXCHANGER
11
12
13
BT
BIB TAP
HR HOSE REEL
M
METER
VALVE
TMV
STRAINER
PRV
PRESSURE RELIEF VALVE
PRESSURE GAUGE
PRESSURE VESSEL
NON RETURN VALVE
DOUBLE CHECK VALVE
PUMP
TUNDISH
DEAD LEG
FILTER
DRAIN / SAMPLE POINT
PIPE BREAK
TEMPERATURE GUAGE
WC TOILET
WB WASH HAND BASIN
B BATH
UCT URINAL CISTERN
ELS ELECTRIC SHOWER
MXS MIXER SHOWER
SK SINK
BLS BELFAST SINK
ZEW EMERGENCY EYE WASH
ZS EMERGENCY SHOWER
DW DISH WASHER
WM WASHING MACHINE
S SLUICE
DRM DRINKS MACHINE
DWF
DRINKING WATER
FOUNTAIN
CWF CHILLED WF
SO STEAM OVEN
PU PRESSURIZED UNIT
5
ISOLATED VALVE
*
MCWS 1
(601 PLANT ROOM)
SV
BLOCK 1
GR
OU
ND
F
LO
OR
VO
ID
LO
FT
601
PLANT
ROOM
LPHWSC 1
PU
001
ROOM
1
SK
002
GENTS
WB WC
003
LADIES
WB WC
004
COMMON
ROOM
WB SK DW WM
*
005
CLEANERS
SK
006
GENTS
WB WC
007
ACCESS
TOILET
WB
008
ROOM
3
SK
*
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
1
2
3
4
5
6
7
1
2
3
4
5
6
7
Scale: NTS Size: A4 Sheet: 1 of 1
REV DATE DESCRIPTION DRAWN CHECKED
0 21-08-2019 INITIAL RELEASE
These drawings must not be copied or
duplicated nor shown to or placed at the
disposal of third person without our written
consent
HW
MCW
=
=
HOT WATER
MAINS COLD WATER
CCW = CISTERN COLD WATER
KEY
FITTINGS
EQUIPMENT
HWR = HOT WATER RETURN
= BLENDED WATERBW
EQUIPMENT SYMBOLS
LOW PRESSURE HOT
WATER
STORAGE CALORIFIER
9
IMMERSION HEATER
SENTINEL OUTLETS
1 2
3 4
6
7 8
9
1 LPHWSC
ELECTRIC STORAGE
CALORIFIER
2 ESC
REMOTE GAS
WATER HEATER (COMBI)
3 RGWH
REMOTE ELECTRIC
WATER HEATER
4 REWH
INSTANTANEOUS
HOT WATER HEATER
5 IHWH
HYDROBOIL6 HB
LOW PRESSURE HOT
WATER STORAGE
CALORIFIER (T)
7
LPHWSC
(T)
ELECTRIC STORAGE
CALORIFIER (T)
8
ESC (T)
DWG. No.: 1E1829S314
T
HWBV
SHSV
10
11
12
13 PHE
Tank
HOT WATER BUFFER
VESSEL
10
DGSC
DIRECT FIRED GAS HOT
WATER CYLINDER
SOLAR PRE-HEAT
STORAGE VESSEL
PLATE HEAT
EXCHANGER
11
12
13
BT
BIB TAP
HR HOSE REEL
M
METER
VALVE
TMV
STRAINER
PRV
PRESSURE RELIEF VALVE
PRESSURE GAUGE
PRESSURE VESSEL
NON RETURN VALVE
DOUBLE CHECK VALVE
PUMP
TUNDISH
DEAD LEG
FILTER
DRAIN / SAMPLE POINT
PIPE BREAK
TEMPERATURE GUAGE
WC TOILET
WB WASH HAND BASIN
B BATH
UCT URINAL CISTERN
ELS ELECTRIC SHOWER
MXS MIXER SHOWER
SK SINK
BLS BELFAST SINK
ZEW EMERGENCY EYE WASH
ZS EMERGENCY SHOWER
DW DISH WASHER
WM WASHING MACHINE
S SLUICE
DRM DRINKS MACHINE
DWF
DRINKING WATER
FOUNTAIN
CWF CHILLED WF
SO STEAM OVEN
PU PRESSURIZED UNIT
5
ISOLATED VALVE
GR
OU
ND
F
LO
OR
UN
DE
RG
RO
UN
DV
OID
CHAMBER 1
BLOCK 1
CHAMBER 2
UNDERGROUND
ROOM 001
UV
FILTER
T1
FOUNTAIN
MCWS 1
(GF RM 001)
SV
FROM T1TO T1
Top Related