External perimeter protectionActive Infra RedMotion sensors
Farshid OssarehDecember 2004
2 / 38Detection Business Unit - GE Security EMEA
1 – Beginning: The audience challenge
1principleTheoryWorking SwitchingVisibilityFog discrimination
3 / 38Detection Business Unit - GE Security EMEA
Infrared light
TYPE of the detector >>>>ACTIVE
Infra RedPASSIVEInfra Red
Nearinfrared Far infrared
V i s i b l e L i g h tUltraviolet
950 nm400 nm 500 nm 700 nm600 nm 5µm
SB series use the active infra red light
4 / 38Detection Business Unit - GE Security EMEA
Working principle
Invisible IR signal beams between transmitter and reciever over a protected distance
Transmitter Reciever
5 / 38Detection Business Unit - GE Security EMEA
Working principle
Transmitter send a light signal which is invisible to human (infrared signal wave of 900nm).
Reciever act as a elctronic eye, analyze the amplitude of the signal send by transmitter
2°
Transmitter Reciever
6 / 38Detection Business Unit - GE Security EMEA
Working principle
Not sensitive to rainNot sensitive to any movement doesn’t cut the beamsNot sensitive to EM wave and signals
2°
Transmitter Reciever
7 / 38Detection Business Unit - GE Security EMEA
Communication principle
Channels are made by pulse frequency
Pulsed beams and selectable channelsPulsed beams and selectable channels
Receiver on ch1 will only see the Transmitter on ch1 & …
Ch 1 Ch1
Ch 2 Ch 2
Rec Trans
Ch1
Ch2
Ch3
Ch4
8 / 38Detection Business Unit - GE Security EMEA
Switching principle SB250 / SB2100
> Communication princple: Pulsed beams and selectable channels> Rotection zone is about 20cm
> Both beams needs to be intruppted to trigger the alarm
9 / 38Detection Business Unit - GE Security EMEA
Switching principle SB450 / SB4100 / SB4200
> Communication princple: Pulsed beams and selectable channels> Rotection zone is about 40cm
> Both beams needs to be intruppted to trigger the alarm
10 / 38Detection Business Unit - GE Security EMEA
Visibilty diagramGeneal rule: the range is equal to visibilty on site.The SB series range > Theoretical max range: 2550m> When the visibility is 200m, the range will be 200m> When the visibility is 60m (fog), the range will be 60m
AIR Range200m
100m
50m
50m 100m 200m Visibility
80m
If the average visibility during the normal fog is 80m, it is
recommended not to install a 100 or 200m product.
11 / 38Detection Business Unit - GE Security EMEA
Fog dectection
Receiver analyse the signal power
12 / 38Detection Business Unit - GE Security EMEA
When the signal amplitude at the reciever reaches the minimun level the disqualification relay will be triggered,
Fog dectection
13 / 38Detection Business Unit - GE Security EMEA
Max 60 sAlarm relay
(NC)
Disq relay(NO)
Spec. Feature
If the alarm relays are connected in serie and there is a steady obstruction, the AIR beam will
release the alarm relay and trigger disqualication relay.
14 / 38Detection Business Unit - GE Security EMEA
1 – Beginning: The audience challenge
2RangeSelectionModular beamsModular pillars
15 / 38Detection Business Unit - GE Security EMEA
How to select the products On price
Low risk
Perimeters high walls
Perimeters rond the building
Mid Risk
Garage/Concession
Small factory
Perception to detection
High risk
Big factories
Perimeter Detection
16 / 38Detection Business Unit - GE Security EMEA
External perimeter protection Active Infra RedMotion sensors
Modular AIR beams
17 / 38Detection Business Unit - GE Security EMEA
SB250 / SB21002 beamsRange: SB250 125m indoor 50m outdoor
SB2100 250m indoor 100m outdoor4 channel selectionThermostaic contrlled heater on boardProtection hight: 20cm
Rx Ch 1Tx Ch 1
Rx Ch 2Tx Ch 2
Rx Ch 3Tx Ch 3
Rx Ch 4Tx Ch 4
18 / 38Detection Business Unit - GE Security EMEA
SB450 / SB4200 4 beamsRange: SB250 125m indoor 50m outdoor
SB2100 250m indoor 100m outdoor4 channel selectionThermostaic contrlled heater on boardProtection hight 40cm
Rx Ch 1Tx Ch 1
Rx Ch 2Tx Ch 2
Rx Ch 3Tx Ch 3
Rx Ch 4Tx Ch 4
19 / 38Detection Business Unit - GE Security EMEA
External perimeter protection Active Infra RedMotion sensors
Mounted in Pillars
20 / 38Detection Business Unit - GE Security EMEA
Mounted in pillars
To increase the protection hight, SB beams can be mounted in a mouting pillars.Available in : 1m, 1.5m, 2m, 2.5m, 3m
21 / 38Detection Business Unit - GE Security EMEA
Back to back motingBoth sides of the pillars can be used for the back to back mounting
22 / 38Detection Business Unit - GE Security EMEA
1 – Beginning: The audience challenge
3Installation
23 / 38Detection Business Unit - GE Security EMEA
Beam alignement
Horizontal alignment
Vertical alignement
24 / 38Detection Business Unit - GE Security EMEA
Power supply cable selctionCable lengthe for power supply of 12V DC
SB250 / SB2100 SB450 / SB4100 /
SB4200 cable
(mm) Cable(mm²) Tx Rx Tx+Rx Tx Rx Ex+Rx
0,6 0,3 550 300 200 450 250 150 0,9 0,6 1100 700 450 1000 600 400 1,4 1,5 2800 1600 1000 2200 1400 850 1,8 4 - - 1600 - - 1400
SB250 / SB2100 SB450 / SB4100 /
SB4200 cable
(mm) Cable(mm²) Tx Rx Tx+Rx Tx Rx Ex+Rx
0,6 0,3 75 75 30 40 40 20 0,9 0,6 170 170 80 85 85 40 1,4 1,5 400 400 200 190 190 95 1,8 2,5 600 600 300 300 300 160 2,3 4 1000 1000 500 500 500 250
In case the mentioned cable lengthe/diameter limits your installation,
use the optional 230VAC power supply (SB52)
Cable lengthe for the heater of 12V DC/AC
25 / 38Detection Business Unit - GE Security EMEA
Installation guidelineThe protected area should not cut any beams
26 / 38Detection Business Unit - GE Security EMEA
Installation guideline
Maximum 10°
Max 10° as accepted for the correct functionality
27 / 38Detection Business Unit - GE Security EMEA
Installation guidelines
Fence is the best physical perimeter protection which keep the large animals away
28 / 38Detection Business Unit - GE Security EMEA
Installation guidelines
No vegeation my be between the Tx and Rx
29 / 38Detection Business Unit - GE Security EMEA
1 – Beginning: The audience challenge
4Application
30 / 38Detection Business Unit - GE Security EMEA
Military base Airports
VIP Estates / Residences
Communication Centre
CorrectionalInstitution
CommercialIndustrial