COMPANY SCOPEThe company develops, integrates, and delivers complete solutions in the field of Laser Remote Sensing.

We manufacture high-technology LIDAR SYSTEMS and we provide

• Services, maintenance and upgrades related to these instruments • a full spectrum of lidar hardware

• software for data retrieval, instrument control and lidar data analysis

Page 2: Established in Athens, Greece  in  2002

Second GALION Workshop, WMO, Geneva, 20‐23 September 2010

A d v a n c e d L I D A R S y s t e m s

LB - Series Lidar systems (Elastic Backscatter)

LR - Series Lidar systems (Raman)

Ozone DIAL LIDAR systems

Design & Development

Page 3: Established in Athens, Greece  in  2002

Second GALION Workshop, WMO, Geneva, 20‐23 September 2010

A d v a n c e d L I D A R S y s t e m s

LR-ESS-D200Eye–safe: YesDepolarization: Yes, Raman: YesVertical or scanning deployment, Mobile: YesLaser power monitoring, Pre-trigger: upon user request

LB–LR D200Multi-wavelength systemEffective range of measurements: from 150 m up to 15-18 kmEye–safe: NoDepolarization: Yes, Raman: Yes, up to 6 detected channelsMobile: Yes, Power monitoring, Pre-trigger: upon user request

LR –IVU – D400Multi-wavelength system Effective range of measurements: from 450 m up to the strato-sphere, Eye–safe: NoDepolarization: Yes (2), Raman: Yes (2), Water vapor: YesMobile: Yes / Laboratory version also possibleLaser power monitoring, Pre-trigger: upon user request

Page 4: Established in Athens, Greece  in  2002

Second GALION Workshop, WMO, Geneva, 20‐23 September 2010

A d v a n c e d L I D A R S y s t e m s

Multi-wavelength Ozone/Aerosol DIAL system

(266-289-299-316-532S/P-1064 nm)Effective range of measurements: from 800 m up to 15-20 km (up to 60 km upon request)Daytime - nigh-time operationEye–safe: NoUp to 7 detection channelsTransportableLaser power monitoring, Pre-trigger: upon user request

Airborne version: available upon request

Page 5: Established in Athens, Greece  in  2002

Second GALION Workshop, WMO, Geneva, 20‐23 September 2010

A d v a n c e d L I D A R S y s t e m s

CUSTOMIZATION

Page 6: Established in Athens, Greece  in  2002

Second GALION Workshop, WMO, Geneva, 20‐23 September 2010

A d v a n c e d L I D A R S y s t e m s

LICEL Acquisition System

Open source software for:• Data acquisition• System checking and controlling• Lidar data analysis•Ascii files, Binary files or NetCDF

Fully simulated: ray-traced and mechanically, +/- 45o depol. Calibration procedure, Telecover Tests etc.

Page 7: Established in Athens, Greece  in  2002

Second GALION Workshop, WMO, Geneva, 20‐23 September 2010

A d v a n c e d L I D A R S y s t e m s

Page 8: Established in Athens, Greece  in  2002

Second GALION Workshop, WMO, Geneva, 20‐23 September 2010

A d v a n c e d L I D A R S y s t e m s

INDIA New Multiwavelength Lidar System

Page 9: Established in Athens, Greece  in  2002

Second GALION Workshop, WMO, Geneva, 20‐23 September 2010

A d v a n c e d L I D A R S y s t e m s

INDIA New Multiwavelength Lidar System