Page 1 of 27
Parameter Feature Level Class Range Units Commands Ericsson Default
DL Common data BSC FIXED -12 to 12 dB RRLLC, RRLLP 0 0
UL Common data BSC FIXED -12 to 12 dB RRLLC, RRLLP 0 0
BSPWRB Common data CELL VARIABLE 0 to 63 dB RLCPC, RLCPP
CELL Common data CELL FIXED 1 to 7 characters except ALL RLDEI
RSITE Common data CELL FIXED 3 to 15 characters RLDEI
TG Common data CELL VARIABLE 0 to 511
CGI Common data CELL FIXED RLDEC, RLDEP
MCC Common data CELL FIXED 3 digits RLDEC, RLDEP 310
MNC Common data CELL FIXED 2 or 3 digits RLDEC, RLDEP 410
LAC Common data CELL FIXED 1 to 65535 RLDEC, RLDEP
CI Common data CELL FIXED 0 to 65535 RLDEC, RLDEP
NCC Common data CELL FIXED 0 to 7 RLDEC, RLDEP 0 to 7
BCC Common data CELL FIXED 0 to 7 RLDEC, RLDEP 0 to 7
BCCHNO Common data CELL FIXED ARFCN RLDEC, RLDEP 12 to 15 BCCH's
BCCHTYPE Common data CELL FIXED COMB, COMBC, NCOMB RLDEC, RLDEP NCOMB
AGBLK Common data CELL FIXED RLDEC, RLDEP 1 0
MFRMS Common data CELL FIXED 2 to 9 RLDEC, RLDEP 6
FNOFFSET Common data CELL FIXED 0 to 1325 RLDEC, RLDEP 0 0
ECSC Common data CELL FIXED NO, YES RLSBC, RLSBP NO YES
SCTYPE Common data CELL FIXED UL, OL RLDSI
MNCDIGITHAND Common data BSC FIXED 0 to 2 RAEPC, RAEPP 0 2
TSC Common data CELL FIXED 0 to 7 RLDTC, RLDTP Set to same as BCC Set to same as BCC
MSTXPWR Common data CELL VARIABLE dBm RLCPC, RLCPP
BSPWRT Common data CELL VARIABLE 0 to 63 dBm RLCPC, RLCPP
CHGR Common data CELL FIXED 0 to 15 0 1,2,3
STATE Common data CELL FIXED ACTIVE, HALTED RLSTC, RLSTP ACTIVE
NUMREQBPC Common data CELL FIXED 8 to 128 in steps of 8, SYSDEF RLBDC, RLBDP SYSDEF
Cingular Recommendation
RXMOI, RXMOC, RXMSC, RXESE, RXESI, RXTCI, RXTCE, RXBLE, RXBLI, RXPLI, RXPLE, RXAPI, RXAPE, RXMOP.
CGI is MCC-MNC-LAC-CI. See range info for each of these parameters.
128 to 251 (GSM 800)512 to 810 (GSM 1900)
COMB for 1 TRU NCOMB for > 1 TRU
0 to 2 (COMB, COMBC)0 to 7 (NCOMB)
CCCH multiframes
4 for Nortel MSC4 or 6 for others
TDMA frames
13 to 43 odd values (GSM 800)4 to 30 even values (GSM 1900)
30 (GSM1900)33 (GSM800)
RLCCC, RLDGI , RLCFP
8 X number of TRUs in channel group
Page 2 of 27
Parameter Feature Level Class Range Units Commands Ericsson Default Cingular Recommendation
DCHNO Common data CELL FIXED ARFCN
BCCD Common data CELL VARIABLE YES, NO YES YES
SDCCH Common data CELL FIXED RLCCC, RLCFP 1
CCHPOS Common data CELL FIXED BCCH, TN RLCCC, RLCFP TN
TN Common data CELL FIXED 0 to 3, 0 or 2 (extended range) RLCCC, RLCFP 2
CBCH Common data CELL FIXED YES, NO RLCCC, RLCFP NO NO
TRADROPLEVEL Common data BSC FIXED 0, 10 to 60, 110 to 160
TRADROPNOTRAF Common data BSC FIXED 25 or 15
CELLR Neighbouring cell relation data CELL VARIABLE 1 to 7 characters except ALL
CTYPE Neighbouring cell relation data CELL VARIABLE EXT, Omitted Omitted
RELATION Neighbouring cell relation data CELL VARIABLE SINGLE, OMITTED RLNRI OMITTED
CS Neighbouring cell relation data CELL FIXED YES, NO RLNRC, RLNRP NO
ACCMIN Idle mode behaviour CELL VARIABLE 47 to 110 dBm RLSSC, RLSSP 110
CCHPWR Idle mode behaviour CELL FIXED dBm RLSSC, RLSSP
CRH Idle mode behaviour CELL FIXED 0 to 14 in steps of 2 dB RLSSC, RLSSP 4 4
NCCPERM Idle mode behaviour CELL FIXED 0 to 7 RLSSC, RLSSP 0,1,2,3,4,5,6,7
SIMSG Idle mode behaviour CELL FIXED 1, 7, 8 RLSMC, RLSMP
MSGDIST Idle mode behaviour CELL FIXED ON, OFF RLSMC, RLSMP
CB Idle mode behaviour CELL FIXED YES, NO RLSBC, RLSBP NO NO
CBQ Idle mode behaviour CELL FIXED HIGH, LOW RLSBC, RLSBP HIGH HIGH
128 to 251 (GSM 800)512 to 810 (GSM 1900)
RLCFI, RLCFE, RLCFP
RLCFI, RLCFE, RLCFP
0 to 160 to 7 if CCHPOS = BCCH0 to 3 if CCHPOS = BCCH and cell is extended range
1 TRU = 0 (COMB)2 TRU = 1 (NCOMB)3 TRU = 1 (NCOMB)4 TRU = 1 (NCOMB)5 TRU = 2 (NCOMB)6 TRU = 2 (NCOMB)7 TRU = 3 (NCOMB)8 TRU = 4 (NCOMB)9 TRU = 4 (NCOMB)10 TRU = 4 (NCOMB)11 TRU = 4 (NCOMB)12 TRU = 4 (NCOMB)
CG0: 1 to 7CG1: 0 to 7
RAEPC, RAEPP.
25 - Alarm = A1125 - Alarm = A3
RAEPC, RAEPP.
RLNRI, RLNRC, RLNRE, RLNRP
RLDEI, RLLHP, RLDEP
YES (Co-sited)NO (Not co-sited)
110
13 to 43 in steps of 2 (GSM 800)4 to 30 in steps of 2 (GSM 1900)
30 (GSM1900)33 (GSM800)
SIMSG=1 MSGDIST=ONSIMSG=7 MSGDIST=OFFSIMSG=8 MSGDIST=OFF
1, ON7, OFF8, OFF
SIMSG=1 MSGDIST=ONSIMSG=7 MSGDIST=OFFSIMSG=8 MSGDIST=OFF
1, ON7, OFF8, OFF
Page 3 of 27
Parameter Feature Level Class Range Units Commands Ericsson Default Cingular Recommendation
ACC Idle mode behaviour CELL FIXED 0 to 15, CLEAR RLSBC, RLSBP CLEAR CLEAR
MAXRET Idle mode behaviour CELL FIXED 1, 2, 4, 7 RLSBC, RLSBP 4 7
TX Idle mode behaviour CELL FIXED 3 to 12, 14, 16, 20, 25, 32, 50 RLSBC, RLSBP 50 32
ATT Idle mode behaviour CELL FIXED YES, NO RLSBC, RLSBP YES YES
T3212 Idle mode behaviour CELL FIXED 0 to 255 Deci hours RLSBC, RLSBP 40
CRO Idle mode behaviour CELL FIXED 0 to 63 dB RLSBC, RLSBP 0
TO Idle mode behaviour CELL FIXED 0 to 7 dB RLSBC, RLSBP 0 0
PT Idle mode behaviour CELL FIXED 0 to 31 RLSBC, RLSBP 0 0
FASTASSIGN Locating BSC FIXED 0, 1 RAEPC, RAEPP 0 0
NOOFPHYSINFOMSG Locating BSC FIXED 0 to 254 RAEPC, RAEPP 35 35
TIMER3105 Locating BSC FIXED 0 to 254 10 ms RAEPC, RAEPP 4 6
EVALTYPE Locating BSC FIXED 1, 3 RLLBC, RLLBP 1 3
TINIT Locating BSC FIXED 0 to 120 RLLBC, RLLBP 1010
TALLOC Locating BSC FIXED 0 to 120 RLLBC, RLLBP 22
TURGEN Locating BSC FIXED 0 to 120 RLLBC, RLLBP 22
TAAVELEN Locating BSC FIXED 1 to 20 RLLBC, RLLBP 4 4
SSEVALSD Locating CELL FIXED 1 to 9 RLLFC, RLLFP 6 6
QEVALSD Locating CELL FIXED 1 to 9 RLLFC, RLLFP 6 6
SSEVALSI Locating CELL FIXED 1 to 9 RLLFC, RLLFP 6 6
QEVALSI Locating CELL FIXED 1 to 9 RLLFC, RLLFP 6 6
SSLENSD Locating CELL FIXED 1 to 20 RLLFC, RLLFP 10 10
QLENSD Locating CELL FIXED 1 to 20 RLLFC, RLLFP 10 10
SSLENSI Locating CELL FIXED 1 to 20 RLLFC, RLLFP 4 4
QLENSI Locating CELL FIXED 1 to 20 RLLFC, RLLFP 4 4
SSRAMPSD Locating CELL FIXED 1 to 20 RLLFC, RLLFP 5 5
SSRAMPSI Locating CELL FIXED 1 to 20 RLLFC, RLLFP 2 1
MISSNM Locating CELL FIXED 0 to 18 RLLOC, RLLOP 3 3
BSPWR Locating CELL VARIABLE 0 to 80 dBm RLLOC, RLLOP variable
MSRXMIN Locating CELL FIXED 0 to 150 RLLOC, RLLOP 104
BSRXMIN Locating CELL FIXED 0 to 150 RLLOC, RLLOP 150
9 for standard cells4 for MSC/BSC border cells
0 for GSM19003 for GSM850
SACCH periods
SACCH periods
SACCH periods
SACCH periods
SACCH periods
SACCH periods
SACCH periods
SACCH periods
SACCH periods
dBm (negative)
dBm (negative)
Page 4 of 27
Parameter Feature Level Class Range Units Commands Ericsson Default Cingular Recommendation
MSRXSUFF Locating CELL FIXED 0 to 150 RLLOC, RLLOP 0 or 150
BSRXSUFF Locating CELL FIXED 0 to 150 RLLOC, RLLOP 150
BSTXPWR Locating CELL VARIABLE 0 to 80 dBm RLLOC, RLLOP variable
KHYST Locating CELL VARIABLE 0 to 63 dB RLNRC, RLNRP 3 3
LHYST Locating CELL VARIABLE 0 to 63 dB RLNRC, RLNRP 3 3
TRHYST Locating CELL VARIABLE 0 to 63 dB RLNRC, RLNRP 2 2
KOFFSET Locating CELL VARIABLE −63 to 63 dB RLNRC, RLNRP 0 0
LOFFSET Locating CELL VARIABLE −63 to 63 dB RLNRC, RLNRP 0 0
TROFFSET Locating CELL VARIABLE −63 to 63 dB RLNRC, RLNRP 0 0
HIHYST Locating CELL VARIABLE 0 to 63 dB RLNRC, RLNRP 5 5
LOHYST Locating CELL VARIABLE 0 to 63 dB RLNRC, RLNRP 3 3
HYSTSEP Locating CELL VARIABLE 0 to 150 RLNRC, RLNRP 90 70
OFFSET Locating CELL VARIABLE −63 to 63 dB RLNRC, RLNRP 0 0
BADQDL Locating BSC FIXED 0 to 100 dtqu RAEPC, RAEPP 55 55
BADQUL Locating BSC FIXED 0 to 100 dtqu RAEPC, RAEPP 55 55
LOWSSDL Locating BSC FIXED 47 to 110 RAEPC, RAEPP 104102, 104
LOWSSUL Locating BSC FIXED 47 to 110 RAEPC, RAEPP 104109
TALIM Locating CELL VARIABLE RLLUC, RLLUP 62 62
PSSBQ Locating CELL FIXED 0 to 63 dB RLLPC, RLLPP 10 7
PSSTA Locating CELL FIXED 0 to 63 dB RLLPC, RLLPP 63 63
PTIMBQ Locating CELL FIXED 0 to 600 s RLLPC, RLLPP 10 15
PTIMTA Locating CELL FIXED 0 to 600 s RLLPC, RLLPP 10 30
BQOFFSET Locating CELL VARIABLE 0 to 63 dB RLNRC, RLNRP 3 3
BQOFFSETAFR Locating CELL VARIABLE 0 to 63 dB RLNRC, RLNRP 3 3
EXTPEN Locating CELL FIXED ON, OFF RLLOC, RLLOP OFF ON
QLIMDL Locating CELL VARIABLE 0 to 100 dtqu RLLUC, RLLUP 55
QLIMDLAFR Locating CELL VARIABLE 0 to 100 dtqu RLLUC, RLLUP 55
QLIMUL Locating CELL VARIABLE 0 to 100 dtqu RLLUC, RLLUP 55
QLIMULAFR Locating CELL VARIABLE 0 to 100 dtqu RLLUC, RLLUP 55
PSSHF Locating CELL FIXED 0 to 63 dB RLLPC, RLLPP 63 63
PTIMHF Locating CELL FIXED 0 to 600 s RLLPC, RLLPP 5 5
IBHOSICH Locating BSC FIXED ON, OFF RLLBC, RLLBP OFF OFF
IHOSICH Locating BSC FIXED ON, OFF RLLBC, RLLBP OFF OFF
SCHO Locating CELL FIXED ON, OFF RLLOC, RLLOP OFF ON
CELLQ Locating CELL FIXED HIGH, LOW RLLUC, RLLUP HIGH HIGH
dBm (negative)
dBm (negative)
dBm (negative)
dBm (negative)
dBm (negative)
0 to 63 (normal range)0 to 219 (extended range)
Bit periods (bp)
45 non hopping55 hopping
55 non hopping65 hopping
45 non hopping55 hopping
55 non hopping65 hopping
Page 5 of 27
Parameter Feature Level Class Range Units Commands Ericsson Default Cingular Recommendation
MAXTA Locating CELL FIXED RLLDC, RLLDP 63 63
RLINKUP Locating CELL VARIABLE 1 to 63 RLLDC, RLLDP 16 32
RLINKT Locating CELL VARIABLE 1 to 63 RLSSC, RLSSP 16 32
HPBSTATE Locating CELL FIXED ACTIVE, INACTIVE INACTIVE ACTIVE
CHALLOC BSC FIXED 0 to 2 RAEPC, RAEPP 0 2
EBANDINCLUDED BSC FIXED 0 and 1 RAEPC, RAEPP 0 0
MAXCHDATARATE BSC FIXED 96 and 144 RAEPC, RAEPP 96 96
SPEECHVERUSED BSC FIXED 0 and 1 RAEPC, RAEPP 1 0
BSCMC BSC FIXED ON, OFF OFF OFF
CMDR CELL FIXED 96 and 144 144 144
CHAP CELL FIXED 0 to 10 RLHPC, RLHPP 0
SAS CELL FIXED QUALITY, MAIO, MULTI RLGAC, RLGAP QUALITY QUALITY
NECI CELL FIXED 0 and 1 RLSSC, RLSSP 0 1
MC CELL FIXED ON, OFF OFF OFF
CHCODING BSC FIXED CS-1 or CS-2 RAEPC, RAEPP 2 2
GPRSNWMODE BSC FIXED 0 to 3 RAEPC, RAEPP 2 2
GPRSPRIO BSC FIXED 0 to 63 RAEPC, RAEPP 0 1
PILTIMER BSC FIXED 1 to 3600 s RAEPC, RAEPP 20 10
EGPRSBPCLIMIT BSC FIXED 0 to 8160 BPC's DBTSP
ONDEMANDGPHDEV BSC FIXED 1 and 256 RAEPC, RAEPP 20 20
ONDEMANDGPHDV64 BSC FIXED 0 to 63 RAEPC, RAEPP 5 5
PSETCHKPERIOD BSC VARIABLE 0 to 60 min RAEPC, RAEPP 5 5
0 to 63 (normal range)0 to 219 (extended range)
Bit periods (bp)
SACCH periods
SACCH periods
RLPBI, RLPBP , RLPBE
Channel administration / Immediate assignment on TCH
Channel administration / Immediate assignment on TCH
Channel administration / Immediate assignment on TCH
Channel administration / Immediate assignment on TCH
Channel administration / Immediate assignment on TCH
RLCDC , RLCDP
Channel administration / Immediate assignment on TCH
RLDRC , RLDRP
Channel administration / Immediate assignment on TCH
BCCH on overlay 6 or 8, otherwise 0 or 1. Multiband cell = 8.
Channel administration / Immediate assignment on TCH
Channel administration / Immediate assignment on TCH
Channel administration / Immediate assignment on TCH
RLCDC , RLCDP
GPRS/EGPRS Channel Administration
GPRS/EGPRS Channel Administration
GPRS/EGPRS Channel Administration
GPRS/EGPRS Channel Administration
GPRS/EGPRS Channel Administration
GPRS/EGPRS Channel Administration
GPRS/EGPRS Channel Administration
GPRS/EGPRS Channel Administration
Page 6 of 27
Parameter Feature Level Class Range Units Commands Ericsson Default Cingular Recommendation
TBFDLLIMIT BSC FIXED 1 to 8 RAEPC, RAEPP 2 2
TBFULLIMIT BSC FIXED 1 to 6 RAEPC, RAEPP 2 2
NACCACT BSC FIXED 0 or 1 RAEPC, RAEPP 1 1
PDCHPREEMPT BSC FIXED 0 to 4 0
GPRSSUP CELL FIXED ON, OFF OFF ON
FPDCH CELL FIXED RLGSC, RLGSP 0 1
SCALLOC CELL FIXED UL, OL, BOTH UL, BOTH, OL RAEPC, RAEPP UL
PDCHALLOC CELL FIXED NOPREF, FIRST, LAST RLGSC, RLGSP NOPREF FIRST
PSKONBCCH CELL FIXED ENABLED, DISABLED RLGSC, RLGSP ENABLED ENABLED
NUMREQCS3CS4BPC CELL FIXED 0 to 128 RLBDC, RLBDP 0 0
NUMREQEGPRSBPC CELL FIXED 0 to 128 RLBDC, RLBDP 0 4
TN7BCCH CELL FIXED EGPRS, GPRS RLBDC, RLBDP GPRS GPRS
GPRSEDAACT BSC FIXED 0 or 1 RAEPC, RAEPP 0 1
PULSCHEDINT BSC FIXED 0 to 10, 99 RAEPC, RAEPP 0 3
DMPSTATE Dynamic MS Power Control CELL FIXED ACTIVE or INACTIVE INACTIVE ACTIVE
AMRPCSTATE Dynamic MS Power Control CELL FIXED ACTIVE or INACTIVE INACTIVE ACTIVE
SSDESUL Dynamic MS Power Control CELL VARIABLE 47 to 110 RLPCC, RLPCP 85 104
SSDESULAFR Dynamic MS Power Control CELL VARIABLE 47 to 110 RLAPC, RLAPP 85 104
SSLENUL Dynamic MS Power Control CELL FIXED 3 to 15 RLPCC, RLPCP 5 3
LCOMPUL Dynamic MS Power Control CELL VARIABLE 0 to 100 % RLPCC, RLPCP 70 6
QDESUL Dynamic MS Power Control CELL VARIABLE 0 to 70 dtqu RLPCC, RLPCP 20 20
QDESULAFR Dynamic MS Power Control CELL VARIABLE 0 to 70 dtqu RLAPC, RLAPP 20 40
QLENUL Dynamic MS Power Control CELL FIXED 1 to 20 RLPCC, RLPCP 8 3
GPRS/EGPRS Channel Administration
GPRS/EGPRS Channel Administration
GPRS/EGPRS Channel Administration
GPRS/EGPRS Channel Administration
1 (R10)4 (R11)
GPRS/EGPRS Channel Administration
RLGSI, RLGSE , RLGSP
GPRS/EGPRS Channel Administration
0 to 80 to 4 (extended range)
GPRS/EGPRS Channel Administration
BOTHUL (FPDCH in Underlaid)BOTHOL (FPDCH in Overlaid)
GPRS/EGPRS Channel Administration
GPRS/EGPRS Channel Administration
GPRS/EGPRS Channel Administration
GPRS/EGPRS Channel Administration
GPRS/EGPRS Channel Administration
GPRS/EGPRS Channel Administration
GPRS/EGPRS Channel Administration
RLPCI, RLPCE, RLPCP
RLAPI, RLAPE, RLAPP
dBm (negative)
dBm (negative)
SACCH periods
SACCH periods
Page 7 of 27
Parameter Feature Level Class Range Units Commands Ericsson Default Cingular Recommendation
QCOMPUL Dynamic MS Power Control CELL VARIABLE 0 to 100 % RLPCC, RLPCP 30 90
REGINTUL Dynamic MS Power Control CELL FIXED 1 to 30 RLPCC, RLPCP. 5 1
DTXFUL Dynamic MS Power Control CELL FIXED 0 to 40 RLPCC, RLPCP 5 5
STEPLIMDL Dynamic MS Power Control BSC FIXED ON, OFF OFF OFF
ALPHA BSC VARIABLE 0 to 10 0.1 RAEPC, RAEPP 0 0
GAMMA CELL VARIABLE 0 to 62, even values dB RLGSC, RLGSP 0 6
AMRPCSTATE Dynamic BTS Power Control CELL FIXED ACTIVE or INACTIVE INACTIVE ACTIVE
UPDWNRATIO Dynamic BTS Power Control BSC FIXED 100 to 700 RAEPC, RAEPP 200 200
DBPSTATE Dynamic BTS Power Control CELL FIXED ACTIVE or INACTIVE INACTIVE ACTIVE
SDCCHREG Dynamic BTS Power Control CELL FIXED ON, OFF RLBCC, RLBCP OFF ON
SSDESDL Dynamic BTS Power Control CELL VARIABLE 47 to 110 RLBCC, RLBCP 70 90 or 93
SSDESDLAFR Dynamic BTS Power Control CELL VARIABLE 47 to 110 RLAPC, RLAPP 70 96
REGINTDL Dynamic BTS Power Control CELL FIXED 1 to 10 RLBCC, RLBCP 5 1
SSLENDL Dynamic BTS Power Control CELL FIXED 3 to 15 RLBCC, RLBCP 5 3
LCOMPDL Dynamic BTS Power Control CELL VARIABLE 0 to 100 % RLBCC, RLBCP 70 5
QDESDL Dynamic BTS Power Control CELL VARIABLE 0 to 70 dtqu RLBCC, RLBCP 20 30 to 40
QDESDLAFR Dynamic BTS Power Control CELL VARIABLE 0 to 70 dtqu RLAPC, RLAPP 20 40
QCOMPDL Dynamic BTS Power Control CELL VARIABLE 0 to 60 % RLBCC, RLBCP 30 50 to 55
QLENDL Dynamic BTS Power Control CELL FIXED 1 to 20 RLBCC, RLBCP 8 3
BSPWRMIN Dynamic BTS Power Control CELL FIXED −20 to +50 dBm RLBCC, RLBCP −20 -20
DTXD Discontinuous Transmission CELL FIXED ON, OFF RLCXC, RLCXP OFF ON
DTXU Discontinuous Transmission CELL FIXED 0 to 2 RLSSC, RLSSP 1
HOP Frequency Hopping CELL FIXED ON, OFF, TCH RLCHC, RLCFP OFF
HSN Frequency Hopping CELL VARIABLE 0 to 63 RLCHC, RLCFP
FHOP Frequency Hopping CELL VARIABLE BB, SY SY
COMB Frequency Hopping CELL VARIABLE FLT, HYB HYB
CONFMD Frequency Hopping CELL VARIABLE NODEL, CMD, FASTREC, MINDIST NODEL MINDIST
MAIO MAIO Management CELL VARIABLE 0 to 63 or DEFAULT RLCHC, RLCFP DEFAULT
SACCH periods
SACCH periods
GPRS/EGPRS Dynamic MS Power Control
GPRS/EGPRS Dynamic MS Power Control
RLAPI, RLAPE, RLAPP
RLBCI, RLBCE, RLBCP
dBm (negative)
dBm (negative)
SACCH periods
SACCH periods
SACCH periods
ON for TCHOFF for BCCH
RXMOC, RXMOP
RXMOI, RXMOC, RXMOP
RXMSC, RXMOC, RXMOP
Page 8 of 27
Parameter Feature Level Class Range Units Commands Ericsson Default Cingular Recommendation
IHO Intra-Cell Handover CELL FIXED ON, OFF RLIHC, RLIHP OFF ON
TMAXIHO Intra-Cell Handover CELL FIXED 0 to 60 s RLIHC, RLIHP 6 6
TIHO Intra-Cell Handover CELL FIXED 0 to 60 s RLIHC, RLIHP 10 10
MAXIHO Intra-Cell Handover CELL VARIABLE 0 to 15 RLIHC, RLIHP 3 1
QOFFSETUL Intra-Cell Handover CELL VARIABLE −50 to +50 dtqu RLIHC, RLIHP 0
QOFFSETULAFR Intra-Cell Handover CELL VARIABLE −50 to +50 dtqu RLIHC, RLIHP 0
QOFFSETDL Intra-Cell Handover CELL VARIABLE −50 to +50 dtqu RLIHC, RLIHP 0
QOFFSETDLAFR Intra-Cell Handover CELL VARIABLE −50 to +50 dtqu RLIHC, RLIHP 0
SSOFFSETUL Intra-Cell Handover CELL VARIABLE −30 to +30 dB RLIHC, RLIHP 0 24
SSOFFSETULAFR Intra-Cell Handover CELL VARIABLE −30 to +30 dB RLIHC, RLIHP 0 24
SSOFFSETDL Intra-Cell Handover CELL VARIABLE −30 to +30 dB RLIHC, RLIHP 0 16
SSOFFSETDLAFR Intra-Cell Handover CELL VARIABLE −30 to +30 dB RLIHC, RLIHP 0 16
ASSOC Assignment to Other Cell BSC FIXED ON, OFF RLLBC, RLLBP OFF ON
IBHOASS Assignment to Other Cell BSC FIXED ON, OFF RLLBC, RLLBP OFF ON
AW Assignment to Other Cell CELL FIXED ON, OFF RLLOC, RLLOP OFF ON
CAND Assignment to Other Cell CELL FIXED AWN, NHN, BOTH RLNRC, RLNRP BOTH BOTH
AWOFFSET Assignment to Other Cell CELL VARIABLE 0 to 63 dB RLNRC, RLNRP 3 5
SCLDTIMEINT BSC VARIABLE 100 to 1000 ms RAEPC, RAEPP 100 100
SCLD CELL FIXED ON, OFF RLLLC, RLLLP OFF
SCLDLL CELL VARIABLE 0 to 99 % RLLLC, RLLLP 20 20
SCLDUL CELL VARIABLE 0 to 100 % RLLLC, RLLLP 30 30
LOL CELL VARIABLE 0 to 200 dB RLOLC, RLOLP 200
LOLHYST CELL VARIABLE 0 to 63 dB RLOLC, RLOLP 3 2
TAOL CELL VARIABLE 0 to 61 Bit periods RLOLC, RLOLP 61
TAOLHYST CELL VARIABLE 0 to 61 Bit periods RLOLC, RLOLP 1
HCSBANDHYST Hiearchical Cell Structures BSC VARIABLE 0 to 63 dB RLHBC, RLHBP 2 2
THO Hiearchical Cell Structures BSC FIXED 10 to 100 s RLLBC, RLLBP 30 30
NHO Hiearchical Cell Structures BSC FIXED 2 to 10 RLLBC, RLLBP 3 3
HCSBAND Hiearchical Cell Structures BSC VARIABLE 1 to 8 RLHBC, RLHBP 2
HCSBANDTHR Hiearchical Cell Structures BSC FIXED 0 to 150 RLHBC, RLHBP 95 2
-5 for hopping -14 for fixed
5 for hopping0 for fixed
-5 for hopping -14 for fixed
5 for hopping0 for fixed
Overlaid / Underlaid Subcells / Subcell Load Distribution
Overlaid / Underlaid Subcells / Subcell Load Distribution
ON for markets with overlay/underlay. OFF otherwise.
Overlaid / Underlaid Subcells / Subcell Load Distribution
Overlaid / Underlaid Subcells / Subcell Load Distribution
Overlaid / Underlaid Subcells / Subcell Load Distribution
Overlaid / Underlaid Subcells / Subcell Load Distribution
Overlaid / Underlaid Subcells / Subcell Load Distribution
Overlaid / Underlaid Subcells / Subcell Load Distribution
dBm (negative)
Page 9 of 27
Parameter Feature Level Class Range Units Commands Ericsson Default Cingular Recommendation
LAYER Hiearchical Cell Structures CELL FIXED 1 to 8 2 RLLHC, RLLHP 2
LAYERTHR Hiearchical Cell Structures CELL FIXED 0 to 150 RLLHC, RLLHP 75
LAYERHYST Hiearchical Cell Structures CELL FIXED 0 to 63 dB RLLHC, RLLHP 2 3
PSSTEMP Hiearchical Cell Structures CELL FIXED 0 to 63 dB RLLHC, RLLHP 0 0
PTIMTEMP Hiearchical Cell Structures CELL FIXED 0 to 600 s RLLHC, RLLHP 0 0
FASTMSREG Hiearchical Cell Structures CELL FIXED ON, OFF RLLHC, RLLHP OFF OFF
XRANGE Extended Range CELL FIXED YES, NO RLDEC, RLDEP NO NO
MBCCHNO Double BA Lists CELL FIXED ARFCN RLMFC, RLMFP
ICMSTATE Idle Channel Measurements CELL FIXED ACTIVE, PASSIVE, NOALLOC PASSIVE ACTIVE
INTAVE Idle Channel Measurements CELL FIXED 1 to 31 RLIMC, RLIMP 6 25
LSSTATE Cell Load Sharing BSC FIXED ACTIVE, INACTIVE INACTIVE INACTIVE
CLSTIMEINTERVAL Cell Load Sharing BSC VARIABLE 100 to 1000 ms RAEPC, RAEPP 100 100
CLSSTATE Cell Load Sharing CELL FIXED ACTIVE, INACTIVE INACTIVE INACTIVE
CLSACC Cell Load Sharing CELL VARIABLE 1 to 100 % RLLCC, RLLCP 40 40
CLSLEVEL Cell Load Sharing CELL VARIABLE 0 to 99 % RLLCC, RLLCP 20 20
CLSRAMP Cell Load Sharing CELL FIXED 0 to 30 s RLLCC, RLLCP 5 16
HOCLSACC Cell Load Sharing CELL VARIABLE ON, OFF RLLCC, RLLCP OFF ON
RHYST Cell Load Sharing CELL VARIABLE 0 to 100 % RLLCC, RLLCP 75 75
CLMRKMSG Multiband Operation BSC FIXED 0 to 3 RAEPC, RAEPP 0 0
MODE Multiband Operation BSC FIXED MULTI, SINGLE SINGLE Single or Multi
GSYSTYPE Multiband Operation BSC FIXED Mixed or GSM1900
CSYSTYPE Multiband Operation CELL FIXED GSM800, GSM900, GSM1800, GSM1900 RLDEI, RLDEP GSM800 or GSM1900 GSM800 or GSM1900
MBCR Multiband Operation CELL FIXED 0 to 3 RLSSC, RLSSP 0 0, 2 or 3
DCAHANDOVER Differential Channel Allocation BSC 0, 1 RAEPC, RAEPP 0 0
DCASTATE Differential Channel Allocation BSC FIXED ON, OFF OFF OFF
EMERGPRL Differential Channel Allocation BSC FIXED 1 to 15 RLDCI , RLDCP
STATSINT Differential Channel Allocation BSC FIXED 1 to 96 RLSCI, RLSCP
CHTYPE Differential Channel Allocation CELL TCH, SDCCH RLPRC, RLPRP
CHRATE Differential Channel Allocation CELL FR, HR RLPRC, RLPRP
PHSTATE BSC 0,1 RAEPC, RAEPP 0
2 (GSM1900)3 (GSM800)
dBm (negative)
95 (GSM1900)85 (GSM800)
128 to 251 (GSM 800)512 to 810 (GSM 1900)
RLIMI, RLIMP , RLIME
SACCH periods
RLLSI, RLLSE, RLLSP
RLLCI, RLLCE, RLLCP
RLOMC, RLOMP
GSM800, GSM900, GSM1800, GSM1900, MIXED
RLTYC, RLTYI, RLTYP
RLDCI, RLDCE , RLDCP
15 min. periods
Enhanced Multi-Level Precedence and Pre-Emption Service
Page 10 of 27
Parameter Feature Level Class Range Units Commands Ericsson Default Cingular Recommendation
ACSTATE CELL FIXED ON, OFF OFF ON
SLEVEL CELL FIXED 0 to 2, CONG RLACC, RLACP 0 0
STIME CELL FIXED 15 to 360 s RLACC, RLACP 20 40
COEXUMTS BSC 0, 1 RAEPC, RAEPP 0 0, 1
COEXUMTSINT BSC 100 to 1000 ms RAEPC, RAEPP 1000 1000
UMFI CELL RLUMC, RLUMP
FDDQMIN CELL 0 to 7 RLSUC, RLSUP 0 7
FDDQOFF CELL 0 to 15 dB RLSUC, RLSUP 8 0
SPRIO CELL NO, YES RLSUC, RLSUP NO YES
QSI CELL 0 to 15 RLSUC, RLSUP 15 7
ISHOLEV CELL 0 to 99 % RLLOC, RLLOP 20 99
FDDMRR CELL 0 to 3 RLSUC, RLSUP 0 1
QSC CELL 0 to 15 RLSUC, RLSUP 15 15
QSCI CELL 0, 1 RLSUC, RLSUP 0 0
CELLR CELL 1 to 7 characters except ALL
SET Adaptive Multi-Rate BSC FIXED FR3, FR4, HR3, HR4 RLADC, RLADP
MODE Adaptive Multi-Rate BSC FIXED RLADC, RLADP
HYST Adaptive Multi-Rate BSC FIXED 0 to 15 0.5 dB RLADC, RLADP
THR Adaptive Multi-Rate BSC FIXED 0 to 63 0.5 dB RLADC, RLADP
AMRFRSUPPORT Adaptive Multi-Rate BSC FIXED 0 to 4 RAEPC, RAEPP 0 1
AMRHRSUPPORT Adaptive Multi-Rate BSC FIXED 0 to 4 RAEPC, RAEPP 0 1
LQCACT Link Quality Control in EGPRS BSC FIXED 0, 1 RAEPC, RAEPP 0 3
Adaptive Configuration of Logical Channels
RLACI, RLACE, RLACP
Adaptive Configuration of Logical Channels
Adaptive Configuration of Logical Channels
GSM - UMTS Cell Reselection and Handover
GSM - UMTS Cell Reselection and Handover
GSM - UMTS Cell Reselection and Handover
MFDDARFCN: 0 to 16383MSCRCODE: 0 to 511DIVERSITY: DIV or NODIV
GSM - UMTS Cell Reselection and Handover
dB (relative to -20)
GSM - UMTS Cell Reselection and Handover
GSM - UMTS Cell Reselection and Handover
GSM - UMTS Cell Reselection and Handover
4 dB from -98dBm
GSM - UMTS Cell Reselection and Handover
GSM - UMTS Cell Reselection and Handover
GSM - UMTS Cell Reselection and Handover
4 dB from -98dBm
GSM - UMTS Cell Reselection and Handover
GSM - UMTS Cell Reselection and Handover
RLNRI, RLNRE, RLNRP, RLNCP
1 to 5 (Half Rate)1 to 8 (Full Rate)
Page 11 of 27
Parameter Feature Level Class Range Units Commands Ericsson Default Cingular Recommendation
LQCIR Link Quality Control in EGPRS BSC FIXED 0, 1 RAEPC, RAEPP 1 1
LQCDEFAULTMCSDL Link Quality Control in EGPRS BSC FIXED MCS-1to MCS-9 RAEPC, RAEPP MCS-5 5
LQCDEFAULTMCSUL Link Quality Control in EGPRS BSC FIXED MCS-1to MCS-9 RAEPC, RAEPP MCS-5 3
LQCHIGHMCS Link Quality Control in EGPRS BSC FIXED MCS-1to MCS-9 RAEPC, RAEPP MCS-9 9
LQCUNACK Link Quality Control in EGPRS BSC FIXED 0 to 2 RAEPC, RAEPP 1 1
LA GPRS Link Adaptation CELL VARIABLE ON, OFF RLGSC, RLGSP ON OFF
CHCSDL GPRS Link Adaptation CELL VARIABLE NA, CS-1 to CS-4 RLGSC, RLGSP CS-2 CS-2
PCUQOS GPRS/EGPRS Quality of Service BSC FIXED 0, 1 RAEPC, RAEPP 0 0
THPMBRFACTOR GPRS/EGPRS Quality of Service BSC FIXED 0 to 10 RAEPC, RAEPP 0 0
QOSTHP1 GPRS/EGPRS Quality of Service BSC FIXED 1 to 10 RAEPC, RAEPP 3 3
QOSTHP2 GPRS/EGPRS Quality of Service BSC FIXED 1 to 10 RAEPC, RAEPP 2 2
CONVSTREAMTHP GPRS/EGPRS Quality of Service BSC FIXED 1 to 3 RAEPC, RAEPP 1 1
GPRSQOS BSC FIXED 0 to 1 DBTSP 0
IRC CELL FIXED ON, OFF RLDEC, RLDEP OFF ON
FBOFFS Multi Band Cell CELL VARIABLE -40 to 40 dB RLLOC, RLLOP 0 -10
BAND Multi Band Cell CELL FIXED GSM800, GSM900, GSM1800, GSM1900 RLDGI , RLDGP GSM800 or GSM1900
DLDELAY BSC FIXED 0 to 5000 ms RAEPC, RAEPP 2200 1000
ESDELAY BSC FIXED 0 to 2000 ms RAEPC, RAEPP 750 500
TFILIMIT BSC FIXED 0 to 31 RAEPC, RAEPP 4 4
ULDELAY BSC FIXED 1000 s RAEPC, RAEPP 1000 2000
USFLIMIT BSC FIXED 0 to 6 RAEPC, RAEPP 2 2
DHA Dynamic AMR HR Allocation CELL FIXED ON, OFF RLDHC, RLDHP OFF ON
DMQB CELL FIXED ON, OFF RLDMC, RLDMP OFF ON
DMQBAMR CELL VARIABLE 0 to 100 dtqu RLDMC, RLDMP 50 50
DMQG CELL FIXED ON, OFF RLDMC, RLDMP OFF ON
DMQGAMR CELL VARIABLE 0 to 100 dtqu RLDMC, RLDMP 35 30
GPRS/EGPRS Channel Administration
0 - Legacy Orange BSCs1 - Legacy Blue BSCs
Interference Rejection Combining
GPRS/EGPRS Connection Control And Transfer
GPRS/EGPRS Connection Control And Transfer
GPRS/EGPRS Connection Control And Transfer
GPRS/EGPRS Connection Control And Transfer
GPRS/EGPRS Connection Control And Transfer
Dynamic FR/HR Mode Adaptation
Dynamic FR/HR Mode Adaptation
Dynamic FR/HR Mode Adaptation
Dynamic FR/HR Mode Adaptation
Page 12 of 27
Parameter Feature Level Class Range Units Commands Ericsson Default Cingular Recommendation
DMSUPP CELL FIXED ON, OFF RLDMC, RLDMP OFF
DMTHAMR CELL VARIABLE 0 to 100 % RLDMC, RLDMP 20
DTHAMR Dynamic AMR HR Allocation CELL VARIABLE RLDHC, RLDHP 20
ABISALLOC Flexible Abis CELL VARIABLE Fixed, Flexible Fixed Fixed
ALLOCPREF DTM CELL FIXED QUAL, PACK QUAL QUAL
ANT Hardware CELL FIXED 1-7 Character ‡ ‡
ANTA Hardware CELL FIXED 1-7 Character ‡ ‡
ANTB Hardware CELL FIXED 1-7 Character ‡ ‡
BTDM GPRS BSC FIXED 6 to 1530 in steps of 6, OFF OFF 120
CBCHD GPRS CELL FIXED Yes, No No NO
CRT Ericsson MSC BSC FIXED RCR-SCRT - -
CTEI Hardware CELL FIXED 58 to 62 ‡ ‡
DMQBNAMR AMR CELL FIXED 0 to 100 45 100
DMQGNAMR AMR CELL FIXED 0 to 100 30 0
DMTHNAMR AMR CELL FIXED 0 to 100 20 0
DTCB CELL VARIABLE -63 to 63 -63 ‡
DTCBHYST CELL VARIABLE 0 to 63 2 2
DTCBSC BSC VARIABLE 0,1 0 0
DTHNAMR AMR CELL FIXED 0 to 100 20 0
EGPRSBPCLIMIT GPRS BSC FIXED 0-8160 - 2048
FBCHALLOC BSC VARIABLE 0-2 2 2 2
FLEX64KGPRS Flexible Abis BSC VARIABLE 0-1 0 0
GTDM Ericsson MSC BSC FIXED 0 to 255 - -
HNDBEFOREBANSWM Ericsson MSC BSC FIXED 0 or 1 1 1
HNDRELCHINTRAM Ericsson MSC BSC FIXED 0 or 1 1 1
HNDSDCCHINTI Ericsson MSC BSC FIXED 0 or 1 1 1
HNDSDCCHINTOM Ericsson MSC BSC FIXED 0 or 1 1 1
HNDSDCCHM Ericsson MSC BSC FIXED 0 or 1 1 1
HNDSDCCHTCHM Ericsson MSC BSC FIXED 0 or 1 1 1
HNDTGSOPINTRA Ericsson MSC BSC FIXED 0 to 2500 80 80
LATAUSED Ericsson MSC BSC FIXED 0 or 1 0 0
LIMIT1 Idle Channel Measurements CELL FIXED 0 to 59 Rxlev RLIMC, RLIMP 2 1
LIMIT2 Idle Channel Measurements CELL FIXED 1 to 60 Rxlev RLIMC, RLIMP 6 3
LIMIT3 Idle Channel Measurements CELL FIXED 2 to 61 Rxlev RLIMC, RLIMP 12 6
LIMIT4 Idle Channel Measurements CELL FIXED 3 to 62 Rxlev RLIMC, RLIMP 22 12
LISTTYPE Neighbor CELL FIXED ACTIVE, IDLE, Omitted ‡ ‡
MAXLAPDM DTM CELL FIXED 5 to 12 5 5
Dynamic FR/HR Mode Adaptation
ON only in good environment.
Dynamic FR/HR Mode Adaptation
start at 20 conservative.
start at 20 conservative.
Overlaid / Underlaid Subcells / Subcell Load Distribution
Overlaid / Underlaid Subcells / Subcell Load Distribution
Overlaid / Underlaid Subcells / Subcell Load Distribution
Channel administration / Immediate assignment on TCH
Page 13 of 27
Parameter Feature Level Class Range Units Commands Ericsson Default Cingular Recommendation
MAXNOSDCCHTRX BSC VARIABLE 1 to 4 1 1
MAXSBLK GPRS CELL FIXED 1 to 4 2 2
MAXSMSG GPRS CELL FIXED 1 to 16 7 7
MBCRAC GPRS BSC FIXED 0-1 0 0
MCCSUPPORT other BSC FIXED 0-2 0 1
MPDCH GPRS CELL FIXED Yes, No No No
MPWR Hardware CELL VARIABLE 0 to 63 ‡ ‡
MSQUEUING Wireless Priority Queing BSC FIXED 0-1 0 1
NDIST CELL VARIABLE 0 to 63 10 10
NNCELLS CELL VARIABLE 1 to 5 3 3
PAGLATA Ericsson MSC BSC FIXED 0 or 1 0 0
PAGNUMBERLA Ericsson MSC BSC FIXED 1 to3 1 1
PAGREP1LA Ericsson MSC BSC FIXED 0 to 3 2 2
PAGREPCT1LA Ericsson MSC BSC FIXED 0 to 3 2 2
PAGREPGLOB Ericsson MSC BSC FIXED 0 or 1 0 0
PAGTIMEFRST1LA Ericsson MSC BSC FIXED 2 to 10 4 4
PAGTIMEFRSTGLOB Ericsson MSC BSC FIXED 2 to 10 4 4
PAGTIMEREP1LA Ericsson MSC BSC FIXED 2 to 10 7 7
PAGTIMEREPGLOB Ericsson MSC BSC FIXED 2 to 10 7 7
PAGTIMEREPLATA Ericsson MSC BSC FIXED 2 to 10 7 7
PDCHPREEMPT GPRS CELL FIXED 0 - 4 0 4
PILTIMERFLEX Flexible Abis BSC FIXED 0-100 50 50
PRACHBLK GPRS CELL FIXED 1 to 12 4 4
PRIMPLIM GPRS CELL FIXED 1 to 8 8 8
PSCVL Ericsson MSC BSC FIXED FRV1, FRV2, FRV3, HRV1, HRV2, HRV3 - -
QLENGTH Wireless Priority Queing CELL FIXED 0 to 32 5 5
QOSMAPPING GPRS BSC FIXED 0 to 2 0 2
RESLIMIT Wireless Priority Queing CELL FIXED 1 to 100 25 25
ROMTBIPADDRLSW Remote OMT BSC VARIABLE 0-65535 0 0
ROMTBIPADDRMSW Remote OMT BSC VARIABLE 0-65535 0 0
RXD Hardware CELL VARIABLE A, B, AB - AB
SECPAGEPATH Ericsson MSC BSC FIXED 0 to 2 1 1
SPDCH GPRS CELL FIXED 0 to 16 0 0
SYNCSRC Hardware BOTH FIXED INTI, INTE, PCM, DEFAULT DEFAULT C
SYSTYPE Common data CELL FIXED GSM1900/GSM850 GSM1900 *
TEI Hardware CELL FIXED 0 to 63 for G12, 0 to 57 for G01 ‡ ‡
TFMODE Hardware CELL FIXED M, S, SA ‡ ‡
TIMHNDCMDINTRAM Ericsson MSC BSC FIXED 5 to 120 5 5
TIMPAGINGM Ericsson MSC BSC FIXED 2 to 20 9 9
TRAFBLK GPRS CELL FIXED 0 to 10 0 0
TRXC Hardware CELL FIXED 0 to 15 ‡ ‡
TXID Hardware CELL FIXED 0 to 15 ‡ ‡
Channel administration / Immediate assignment on TCH
Overlaid / Underlaid Subcells / Subcell Load Distribution
Overlaid / Underlaid Subcells / Subcell Load Distribution
Page 14 of 27
Parameter
DL
UL
BSPWRB
CELL
RSITE
TG
CGI
MCC
MNC
LAC
CI
NCC
BCC
BCCHNO
BCCHTYPE
AGBLK
MFRMS
FNOFFSET
ECSC
SCTYPE
MNCDIGITHAND
TSC
MSTXPWR
BSPWRT
CHGR
STATE
NUMREQBPC
Comments
Downlink Line level
Uplink Line Level.
BS output power for the BCCH channel
Cell Name
Radio Site Name. Identity of the radio site where the transceiver group (TG) is located.
Transceiver group (TG) identity.
Cell Global Identity
Mobile Country code
Mobile Network Code.
Location Area Code
Cell Identity code
Network Color Code.
Base Station Color Code.
Absolute RF channel number for BCCH.
Whether BCCH is combined with SDCCH/4, not combined with SDCCH/4, or combined with SDCCH/4+CBCH.
No. paging multiframes; 4 - Nortel MSC, 6 - all other MSC type
Offset in TDMA timing between cells at a synchronized site.
Indicates whether MS in the cell is allowed to use early class mark sending
Subcell type. S-BCCH cell type - UL for 850MHz and OL for 1900MHz
0: 2-digit MNC sent. 1: 3-digit MNC sent on A-interface and 2-digit on Um. 2: 3-digit MNC sent
Training Sequence Code.
Maximum MS power while maintaining a TCH connection
BS output power for the non-BCCH channels
Channel group number. 0 - BCCH, 1- 1900 Hopping, 2- 850 Hopping or 2nd 1900 Cabinet Hopping set
SYSDEF should only be used for cells with a single CHGR. If more than 1 CHGR is setup then NUMREQBPC should be set to 8 times the number of TRX required in the CHGR.
No. CCCH blocks reserved for access grants, 1 if Sys info 7 & 8 or CBCH used with non combined SDCCH (i.e. BCCHTYPE = NCOMB, SDCCH = 1 or more and CBCH = YES) AGBLK = 0 if BCCHTYPE = COMB
Page 15 of 27
Parameter
DCHNO
BCCD
SDCCH
CCHPOS
TN
CBCH
TRADROPLEVEL
TRADROPNOTRAF
CELLR
CTYPE
RELATION
CS
ACCMIN
CCHPWR
CRH
NCCPERM
SIMSG
MSGDIST
CB
CBQ
Comments
Absolute RF channel number.
Defines if the channel group frequencies are allowed for Immediate Assignment.
Dependent upon the quantity of TRXs. If cell is XRANGE then limit is 3
Timeslot on which SDCCH/8 will be defined. CHGR0: 1- 7, CHR1 or greater: 0-7.
Flag for whether Cell Broadcast Channel is defined. Set to NO when BCCHTYPE COMBC is used
Transcoder threshold for high dropped call rate
Related cell designation.
External cell that belongs to another BSC
The parameter is only specified when the relation is oneway.
Co-site, which indicates if a cell shares the same site as its neighbor. S-BCCH cell type = YES.
Minimum RxLev at MS to access a cell: Urban/Suburban/Rural -110 dBm
Maximum power a MS can use when accessing a cell
Cell Reselect Hysteresis for location area boundaries
Permitted network color codes for meas. Reports
System Information BCCH Message distribution.
System Information BCCH Message distribution.
Barring of cell (prevents cell access (not h/o in))
Defines cell priority for phase 2 idle mode selection
Page 16 of 27
Parameter
ACC
MAXRET
TX
ATT
T3212
CRO
TO
PT
FASTASSIGN
NOOFPHYSINFOMSG
TIMER3105
EVALTYPE
TINIT
TALLOC
TURGEN
TAAVELEN
SSEVALSD
QEVALSD
SSEVALSI
QEVALSI
SSLENSD
QLENSD
SSLENSI
QLENSI
SSRAMPSD
SSRAMPSI
MISSNM
BSPWR
MSRXMIN
BSRXMIN
Comments
Access Control Class barring
Max. no. random access retries on RACH
spreading of retransmissions on the RACH
Flag to initiate IMSI Attach/Detach
Periodic location update timer period
Offset between cells for idle mode selection.
Negative temp. offset applied on top of CRO
Duration for which temporary offset applied
Specifies if Locating shall wait before sending the requested candidate list
Indicates the maximum number of repetitions of physical information messages during the handover procedure
Defines the time between repetitions of physical information messages during the handover procedure.
Choice of handover algorithm
Min. time before handover after call init. or handover
Min. time between allocation attempts for better cell
Min. time between allocation attempts for urgency
Timing Advance (TA) averaging window length
RxLev averaging filter type on TCH
RxQual averaging filter type on TCH
RxLev averaging filter type on SDCCH
RxQual averaging filter type on SDCCH
Length of RxLev aver. filter for SSEVALSD = 6 - 9
Length of RxQual aver. filter for QEVALSD = 6 - 9
Length of RxLev aver. filter for SSEVALSI = 6 - 9
Length of RxQual aver. filter for QEVALSI = 6 - 9
Time to ramp up N-cell measurements on TCH
Time to ramp up N-cell measurements on SDCCH STATE ACTIVE or HALTED ‡ ‡ C F Cell or Channel Group state.
Max. allowed missing meas. reports before reset
Tx power on BCCH carrier (at reference point)
Min. SS at MS to consider n-cell a h/o candidate
Min. SS at BTS to consider n-cell a h/o candidate
Page 17 of 27
Parameter
MSRXSUFF
BSRXSUFF
BSTXPWR
KHYST
LHYST
TRHYST
KOFFSET
LOFFSET
TROFFSET
HIHYST
LOHYST
HYSTSEP
OFFSET
BADQDL
BADQUL
LOWSSDL
LOWSSUL
TALIM
PSSBQ
PSSTA
PTIMBQ
PTIMTA
BQOFFSET
BQOFFSETAFR
EXTPEN
QLIMDL
QLIMDLAFR
QLIMUL
QLIMULAFR
PSSHF
PTIMHF
IBHOSICH
IHOSICH
SCHO
CELLQ
Comments
Sufficient SS at MS to consider cell for PL ranking
Sufficient SS at a BTS to consider cell for PL rank
Tx power on non-BCCH carrier (at reference point)
Hysteresis applied when both cells ranked on SS
applied when both cells ranked on PL
Hysteresis when in transition between K and L
Signal strength offset when evaluating K-cells.
Offset applied when both cells are ranked on PL
Offset when in transition between K and L
SS hysteresis when evaluating high SS cells
SS hysteresis when evaluating low SS cells
SS hysteresis when evaluating high SS cells
SS offset
DL BQ limit used for urgency counter - not used in HO algorithm
UL BQ limit used for urgency counter - not used in HO algorithm
DL low SS limit used for counter - not used in HO algorithm
UL low SS limit used for counter - not used in HO algorithm
Timing advance threshold for handover
SS penalty on cell from which h/o occurs (RxQual)
SS penalty on cell from which h/o occurs (TA)
Duration of penalty PSSBQ for RxQual h/o
Duration of penalty PSSTA for TA h/o
Bad RxQual h/o corridor or negative hysteresis
Bad RxQual h/o corridor or negative hysteresis for AMR FR.
Flag to enable penalty "transfer" for inter-BSC h/o
RxQual threshold at MS for h/o. Lower threshold used for cells hopping over 6 or more frequencies, 55 if cell is hopping
Quality limit uplink for handover. Urgency detection parameter.
RxQual threshold at BTS for h/o. Lower threshold used for cells hopping over 6 or more frequencies, 55 if cell is not hopping.
SS penalty applied to a cell to which h/o fails
Duration of penalty PSSHF for handover failure
Flag to enable SDCCH handover inter-BSC
Flag for enabling intra-cell handover on SDCCH
Flag to enable SDCCH handover
Defines if cell is suitable for RPD load regulation
RxQual threshold at MS for h/o. Lower threshold used for cells hopping over 6 or more frequencies, 55 if cell is not hopping *QLIMUL 0-100 55 45 C V RxQual threshold at BTS for h/o. Lower threshold used for cells hopping over 6 or more frequencies, 55 if cell is hopping
Page 18 of 27
Parameter
MAXTA
RLINKUP
RLINKT
HPBSTATE
CHALLOC
EBANDINCLUDED
MAXCHDATARATE
SPEECHVERUSED
BSCMC
CMDR
CHAP
SAS
NECI
MC
CHCODING
GPRSNWMODE
GPRSPRIO
PILTIMER
EGPRSBPCLIMIT
ONDEMANDGPHDEV
ONDEMANDGPHDV64
PSETCHKPERIOD
Comments
Radio Link Timeout counter value on the uplink.
Radio link Timeout counter value for MS (D/L)
Switch for handover power boost
2: Non hopping TCH on BCCH is allocated as last preference 1: Non-hopping TCH on BCCH allocated as first preference 0: No preference
Decide whether channels in the P-GSM 900 band only or whether also GSM 900 G1 channels are to be considered for handling of the radio features.
Defines the maximum channel data rate allowed in the BSC - modem type.
Decides if the used speech version shall be placed at the top in the list of allowed speech version at handover.
Identifies if more than one full rate TCH are allowed to be allocated for each MS connection in BSC internal cells.
Maximum channel data rate for a cell - modem type
Channel allocation profile selection.
Single slot allocation strategy
0 = GSM est. causes only, 1 = phase 2 est. causes NEWNAME 1 TO 7 CHAR. EXCEPT ALL * * C F The parameter is used to change the name of a cell.
ON=multiple channels allocations to MS allowed
GPRS Channel coding scheme to be used
GPRS Network Mode determines if a PBCCH exists in the cell.
Sets the priority between PDCHs and the features Dynamic Half Rate Allocation/Half Rate Packing, Cell Load Sharing and Sub cell Load Distribution
Time a dynamic PDCH channel can remain idle before being reconfigured to a TCH, EDGE\GPRS Cell = 10.
Maximum allowed number of EGPRS timeslots or data connections in the BSC.
Number of reserved GPH devices in an RPP that can be used for on-demand PDCH only.
On Demand GPH Subdevices (64k).
Periodic check of GPRS primary dedicated channels.
Maximum timing advance permitted before disconnection. Normal cell can work to 63. RBS200 Xrange cell with SPP cards can work to 133 and new RBS2000 Xtended range hardware can work to 219.
Page 19 of 27
Parameter
TBFDLLIMIT
TBFULLIMIT
NACCACT
PDCHPREEMPT
GPRSSUP
FPDCH
SCALLOC
PDCHALLOC
PSKONBCCH
NUMREQCS3CS4BPC
NUMREQEGPRSBPC
TN7BCCH
GPRSEDAACT
PULSCHEDINT
DMPSTATE
AMRPCSTATE
SSDESUL
SSDESULAFR
SSLENUL
LCOMPUL
QDESUL
QDESULAFR
QLENUL
Comments
The number of simultaneous TBFs for each PDCH is used as TBF downlink limit.
The number of simultaneous TBFs for each PDCH is used as TBF uplink limit. TDD 1 to 255, OFF OFF B F Ericsson MSC Parameter Only
Activate/Deactivate Network Assisted Cell Change Feature
Defines what kind of on-demand PDCHs are possible to pre-empt for the CS traffic:
Activates/deactivates GPRS support for a cell
Number of dedicated PDCH in cell.
Restrict EGPRS/GPRS to a certain subcell when a subcell exists. Set per Dedicated PDCH location.
Allocates PDCH on BCCH frequency first.
Used to disable the use of 8-PSK on the BCCH carrier.
Number of required CS 3/4 BPCs (set per CHGR).
Minimum number of required EGPRS BPCs (set per CHGR). CHGR0 = 4, CHGR1 or greater = 0.
Allowance of EGPRS or GPRS on TN7 of the BCCH frequency.
GPRS Extended Dynamic Allocation Activation.
Persistent uplink PDCH scheduling interval.
Dynamic MS power control state.
Adaptive Multi-Rate (AMR) power control state.
Desired Signal Strength uplink at BTS
Desired Signal Strength uplink at BTS for AMR FR
Length of U/L DPC RxLev averaging filter
How much path loss is compensated for in MS PC algorithm
Desired RxQual at BTS Rx
Desired RxQual at BTS Rx for AMR FR
Length of uplink DPC RxQual averaging filter
Page 20 of 27
Parameter
QCOMPUL
REGINTUL
DTXFUL
STEPLIMDL
ALPHA
GAMMA
AMRPCSTATE
UPDWNRATIO
DBPSTATE
SDCCHREG
SSDESDL
SSDESDLAFR
REGINTDL
SSLENDL
LCOMPDL
QDESDL
QDESDLAFR
QCOMPDL
QLENDL
BSPWRMIN
DTXD
DTXU
HOP
HSN
FHOP
COMB
CONFMD
MAIO
Comments
Weighting of RxQual compensation in MS DPC
Uplink or MS Power Control Regulation interval
No. of meas. reports in new cell before FULL meas.
When on the step size of BTS PC is limited to 2 dB per SACCH
Path loss compensation for GPRS power control
Gives target value for the received signal at the BTS (PS Specific).
Adaptive Multi-Rate (AMR) power control state.
Ratio of up to down regulation speed of power control
Dynamic BSC power control state.
Controls whether D/L DPC used on SDCCH
Downlink desired signal strength at MS
Downlink desired signal strength at MS for AMR FR
Downlink Power control regulation interval/period
Length of Signal Strength averaging filter D/L DPC
SS path loss compensation in DL
Desired Quality in DL
Desired Quality in DL for AMR FR
Quality path loss compensation in DL
Length of RxQual averaging period for D/L DPC
Minimum DL dynamic power level
Enable/disable of downlink DTX
MS Discontinuous Transmission (DTX) control (u/l), 0 = may use; 1 = shall use, 2 = shall not use DTX
Frequency hopping status, OFF for CHGR=0,ON for GHGR=1
The hopping sequence number
Specifies Base Band or SYnthesized frequency hopping
Defines which combiner type is used for frequency hopping
Defines configuration method impact
Hopping sequence number.
Page 21 of 27
Parameter
IHO
TMAXIHO
TIHO
MAXIHO
QOFFSETUL
QOFFSETULAFR
QOFFSETDL
QOFFSETDLAFR
SSOFFSETUL
SSOFFSETULAFR
SSOFFSETDL
SSOFFSETDLAFR
ASSOC
IBHOASS
AW
CAND
AWOFFSET
SCLDTIMEINT
SCLD
SCLDLL
SCLDUL
LOL
LOLHYST
TAOL
TAOLHYST
HCSBANDHYST
THO
NHO
HCSBAND
HCSBANDTHR
Comments
Flag enabling intra-cell handover on a sub-cell, required if Frequency Hopping active.
Maximum time between intra-cell handovers to consider them as consecutive.
Time for which intra-cell h/o inhibited
Maximum number of consecutive intra-cell handovers allowed. For OL / UL cells it must always be less than the no of CHGR in the subcell
Offset FQSS function along RxQual axis (uplink) ; -5 Hopping Layer, -14 BCCH Layer
Offset FQSS function, RxQual axis (uplink) for AMR FR
Offset FQSS function along RxQual axis (downlink) ; -5 Hopping Layer, -14 BCCH Layer
Offset FQSS function, RxQual axis (downlink) for AMR FR
Offset FQSS function along RxLev axis (uplink)
Offset FQSS function along RxLev axis (uplink), for AMR FR
Offset FQSS function along RxLev axis (downlink)
Offset FQSS function along RxLev axis (downlink) for AMR FR
Flag to enable assignment to another cell
Flag to enable assignment to another cell inter-BSC
Flag to enable assignment to worse cells from a cell
Candidate type.
Assignment to worse cell negative hysteresis
Time interval for checking the level of underlaid sub cell idle TCH for cells active for Sub cell Load Distribution.
Subcell load distribution
Subcell Load Distribution Lower Limit.
Subcell Load Distribution Upper Limit.
Path loss threshold. S-BCCH cell type = (EIRP+85), if data on BCCH set to LOL=0.
Hysteresis for path loss.
Timing advance threshold. S-BCCH cell type = 61.
Hysteresis for timing advance.
Signal Strength hysteresis for the HCSBAND threshold.
Time int for measuring NHO to determine if MS is fast moving
Number of HO during THO that are allowed before MS is considered fast moving
Hierarchical Cell Structure band.
The signal strength threshold prioritizes cells within a HCSBAND.
Page 22 of 27
Parameter
LAYER
LAYERTHR
LAYERHYST
PSSTEMP
PTIMTEMP
FASTMSREG
XRANGE
MBCCHNO
ICMSTATE
INTAVE
LSSTATE
CLSTIMEINTERVAL
CLSSTATE
CLSACC
CLSLEVEL
CLSRAMP
HOCLSACC
RHYST
CLMRKMSG
MODE
GSYSTYPE
CSYSTYPE
MBCR
DCAHANDOVER
DCASTATE
EMERGPRL
STATSINT
CHTYPE
CHRATE
PHSTATE
Comments
Assigns cell to HCS layer. Recommend GSM1900 less than GSM800.
Signal level threshold applying to that cell. (D-BCCH cell: 85 - 1900MHz, 95 - 850MHz)
Hysteresis applied to the cell's Signal Threshold
Size of temp. penalty on meas. from new n-cells
Time of temp. penalty on meas. From new n-cells
ON=Fast moving MS handling on
Whether cell is defined as an extended range cell
Absolute RF channel number for measurement on BCCH.
ICM enable/disabled or used for statistical purpose
Interference Averaging period
Cell Load Sharing at the BSC level
Time interval in which TCH activity is checked when load sharing
Cell load sharing active. inactive for a cell
% idle channel free level, below which no shredded call is accepted by target cell
% idle channel free level at which shedding of calls is started
Time interval in which hysteresis is ramped down
Enable/disable acceptance of incoming h/o due to Load Sharing
Hysteresis reduction factor (how much of hysteresis zone is used for call shedding)
Indicates how the Classmark Change message will be handled if it is received as a first RR message from the Mobile Station
The BSC band operation mode identifier.
Specifies the system type for the BSC. Mixed allows both 850MHz and 1900MHz within the same BSC.
Specifies the system type for the cell.
No. of n-cells from each band reported in measurement report: different between dual band and single band markets.
Differential Channel Allocation is not used
Differential channel allocation switch.
Priority level for emergency calls.
Differential channel allocation statistics collection time interval.
Differential Channel Allocation is not used
Differential Channel Allocation is not used
Indicates if Pre-emption Handling is to be initiated.
Page 23 of 27
Parameter
ACSTATE
SLEVEL
STIME
COEXUMTS
COEXUMTSINT
UMFI
FDDQMIN
FDDQOFF
SPRIO
QSI
ISHOLEV
FDDMRR
QSC
QSCI
CELLR
SET
MODE
HYST
THR
AMRFRSUPPORT
AMRHRSUPPORT
LQCACT
Comments
Enable/disable of dynamic change of SDCCH channels
Remaining SDCCH sub channels when attempt to increase number will take place
Min time before dynamic SDCCH is reconfigured back to TCH
Support for Coexistence of GSM and UMTS
Time interval between traffic load checking.
UTRAN Measurement Frequency Information for cell reselection in GSM Idle Mode and GPRS/EGPRS Ready and Standby states
Defines the minimum threshold for the "quality" measure Ec/No for cell reselection to UTRAN cells.
Defines the inter-system cell reselection offset to UTRAN cells.
Indicates if 3G cells may be searched when BSIC decoding is required.
Indicates the threshold to start UTRAN FDD measurements in Idle mode and Stand-by and Ready states.
Inter system handover evaluations start. % of TCH idle.
Defines how many measured neighbouring UTRAN cells should be included in measurement reports
Indicates the threshold to start UTRAN FDD measurements in Active mode. 15 = Never
UTRAN measurements after entering active mode, before reading the first QSC. 0 = Use QSI threshold, 1 = always.
Related cell designation.
AMR parameters SET, MODE, HYST, and THR to be trialed
Hysteresis for changing the codec mode
Threshold for changing the codec mode
Adaptive Full-Rate feature switch.
Adaptive Half-Rate feature switch.
Used to switch LQC on or off on the downlink and uplink
1 = 4.75 Kbps (HR and FR)2 = 5.15 Kbps (HR and FR)3 = 5.90 Kbps (HR and FR)4 = 6.70 Kbps (HR and FR)5 = 7.40 Kbps (HR and FR)6 = 7.95 Kbps (HR only)7 = 10.2 Kbps (HR only)8 = 12.2 Kbps (HR only)
Page 24 of 27
Parameter
LQCIR
LQCDEFAULTMCSDL
LQCDEFAULTMCSUL
LQCHIGHMCS
LQCUNACK
LA
CHCSDL
PCUQOS
THPMBRFACTOR
QOSTHP1
QOSTHP2
CONVSTREAMTHP
GPRSQOS
IRC
FBOFFS
BAND
DLDELAY
ESDELAY
TFILIMIT
ULDELAY
USFLIMIT
DHA
DMQB
DMQBAMR
DMQG
DMQGAMR
Comments
Used to control which mode LQC shall run TBFs using RLC acknowledged mode.
Controls which DL MCS is used when LQC is switched OFF.
Used to control the MCS for uplink transfers
Used to define the highest allowed MCS level to be used
Used to shift the selection of MCS to a more robust MCS level when RLC unacknowledged mode is used.
Used to switch GPRS Link Adaptation ON and OFF
If GPRS Link Adaptation is switched on, then used as initial coding scheme for downlink
Activates or deactivates support for 3GPP TS 08.18 Packet Flow Management (PFM) in the PCU.
To what degree should MBR be taken into account for scheduling interactive user.
Weight to use for interactive PFCs of THP1
Weight to use for interactive PFCs of THP2
Defines which THP to use if the requested traffic class is not available.
Activates the Interference Rejection Combining feature
Offset between BCCH frequency band group and non- BCCH frequency band group.
Frequency band supported by the transmitter/receiver
Defines the time a downlink TBF is kept alive after there is no more user data to send in downlink.
Defines the time a downlink TBF is kept alive after it has been automatically set up by the initiation of an uplink TBF.
Defines the minimum number of TFIs available for a PSET before ESDELAY or DLDELAY will initiate.
Defines the time an Uplink TBF is kept alive.
Specifies the lower limit for available USFs before uplink TBF is released.
Dynamic AMR Half Rate Allocation feature state.
Defines whether or not Dynamic AMR Half Rate (HR) to AMR Full Rate (FR) Mode Adaptation due to bad quality is active.
Defines a threshold to initiate a change from HR to FR.
Defines whether or not Dynamic AMR Full Rate (FR) to AMR Half Rate (HR) Mode Adaptation quality evaluation is active.
Defines a threshold to initiate a change from FR to HR.
Page 25 of 27
Parameter
DMSUPP
DMTHAMR
DTHAMR
ABISALLOC
ALLOCPREF
ANT
ANTA
ANTB
BTDM
CBCHD
CRT
CTEI
DMQBNAMR
DMQGNAMR
DMTHNAMR
DTCB
DTCBHYST
DTCBSC
DTHNAMR
EGPRSBPCLIMIT
FBCHALLOC
FLEX64KGPRS
GTDM
HNDBEFOREBANSWM
HNDRELCHINTRAM
HNDSDCCHINTI
HNDSDCCHINTOM
HNDSDCCHM
HNDSDCCHTCHM
HNDTGSOPINTRA
LATAUSED
LIMIT1
LIMIT2
LIMIT3
LIMIT4
LISTTYPE
MAXLAPDM
Comments
Dynamic FR/HR Mode Adaptation feature state.
Dynamic FR to HR Mode Adaptation threshold for AMR capable mobile.
Defines a threshold to initiate AMR HR at call allocation.
Controls the way Abis paths are allocated to the TCHs capable of 64kbps, set per TG.
DTM connection shall be allocated with maximum speech quality considerations or with packing considerations prefer TCH/HR.
Name of antenna connected to transmitter
Name of antenna A connected to receiver
Name of antenna B connected to receiver
Base time duration of implicit detach of a mobile subscriber by the network, Ericsson MSC Only.
Shall PSI8 be transferred on the PBCCH or not.
Channel Rate and Type, Ericsson MSC Only.
TGC
Non-AMR trigger from HR to FR channel
Non-AMR trigger from FR to HR channel
HR Packing for Non-AMR Dual Rate capable MS units
Distance to cell border threshold between active channel and neighboring BCCHs.
Hysteresis for the DTCB criterion.
Defines if the DTCB criterion is taken into consideration during subcell changes (1), or not (0)
HR Packing at initial call set-up for Non-AMR Dual Rate capable MS units.
Maximum allowed number of EGPRS timeslots or data connections in the BSC.
0 - No selection preference; 1 - Select channels in BCCH frequency band first; 2 - Select channels in BCCH frequency band last. (Tri-Band Usage Only)
Abis resource allocation handling for EGPRS capable channel.
Guard time duration, Ericsson MSC Only.
Indicates if an inter-MSC handover is allowed on traffic channels before answer from B-subscriber, Ericsson MSC Only.
Defines the release of the original channel after expiration of the timer TIMHNDCMDINTRAM for handover time supervision in intra-MSC inter-BSC handover, Ericsson MSC Only.
Incoming inter-MSC handover on signaling channels in non-anchor MSC, Ericsson MSC Only.
Determines if outgoing inter-MSC handover is allowed on signaling channels in anchor MSC, Ericsson MSC Only.
Determines if intra-MSC inter-BSC handover is allowed on signaling channels, Ericsson MSC Only.
If intra-MSC inter-BSC handover is allowed from signaling to traffic channel, Ericsson MSC Only.
Time supervision of switching moment of the group switch (GS) in the MSC at intra-MSC inter-BSC handover.Ericsson MSCOnly
Defines the usage of LATA administration, Ericsson MSC Only.
Boundary between interference bands 1&2, Alt. Settings: 3 for macro-cells. 6 for micro cells
Boundary between interference bands 2&3, Alt. Settings: 5 for macro cells, 10 for micro cells
Boundary between interference bands 3&4, Alt. Settings: 8 for macro sells, 14 fro micro cells
Boundary between interference bands 4&5, Alt. Settings: 10 for macro cells, 18 for micro cells
This parameter identifies which type of list the chosen frequencies will be on.
DTM, to control the maximum length of the GPRS signaling messages sent on the FACCH.
Page 26 of 27
Parameter
MAXNOSDCCHTRX
MAXSBLK
MAXSMSG
MBCRAC
MCCSUPPORT
MPDCH
MPWR
MSQUEUING
NDIST
NNCELLS
PAGLATA
PAGNUMBERLA
PAGREP1LA
PAGREPCT1LA
PAGREPGLOB
PAGTIMEFRST1LA
PAGTIMEFRSTGLOB
PAGTIMEREP1LA
PAGTIMEREPGLOB
PAGTIMEREPLATA
PDCHPREEMPT
PILTIMERFLEX
PRACHBLK
PRIMPLIM
PSCVL
QLENGTH
QOSMAPPING
RESLIMIT
ROMTBIPADDRLSW
ROMTBIPADDRMSW
RXD
SECPAGEPATH
SPDCH
SYNCSRC
SYSTYPE
TEI
TFMODE
TIMHNDCMDINTRAM
TIMPAGINGM
TRAFBLK
TRXC
TXID
Comments
Maximum number of SDCCH/8 per TRX
The maximum value the BS_PBCCH_BLKS is allowed to have reserved radio blocks to be used for the PBCCH.
The maximum number of PSI messages that preferably shall be scheduled on one PBCCH block.
Defines the method that GPRS/EGPRS MS frequency band capabilities are handled.
Mobile Crosstalk Control support in the transcoders
Whether or not a MPDCH shall be allocated in a PDCCH.
Maximum Transmitter Power
Wireless Priority Service - MS Queuing, Off or On
Distance to cell border additional threshold.
Number of strongest neighboring BCCHs for DTCB criterion.
Ericsson MSC Parameter Only
Ericsson MSC Parameter Only
Ericsson MSC Parameter Only
Ericsson MSC Parameter Only
Ericsson MSC Parameter Only
Ericsson MSC Parameter Only
Ericsson MSC Parameter Only
Ericsson MSC Parameter Only
Ericsson MSC Parameter Only
Ericsson MSC Parameter Only
Defines what kind of on-demand PDCHs are possible to pre-empt for the CS traffic:
Packet idle list timer factor for PDCHs with flexible ABIS.
The minimum number of reserved radio block periods for PRACH.
The maximum number of dedicated and semi-dedicated PDCHs allowed in the primary PSET.
Ericsson MSC Parameter Only
Wireless Priority Service - Maximum Queue Length
Changes or deactivates support for QoS mapping.
Wireless Priority Service - Channel Resource Limit
Low part of the BSC Internet Protocol address for ROMT, if R-OMT active recommended value ignored.
High part of the BSC Internet Protocol address for ROMT, if R-OMT active recommended value ignored.
Defines the use of receiver diversity in a given TRX SAS QUALITY, MAIO, MULTI QUALITY QUALITY C F Single slot allocation strategy.
Ericsson MSC Parameter Only *SET FR3, FR4, HR3, HR4 - - B F Adaptive Multi Rate (AMR) codec set changed by the operator.
Defines the number of semi-dedicated PDCHs.
F Timing function synchronization source in the BSC, must match BTS.
System Type
Terminal Endpoint Identifier. RBS 2000 and RBS 200 series respectively.
Timing Function Synchronization Mode.
Describes the time between the HANDOVER COMMAND and HANDOVER COMPLETE messages in intra-MSC inter-BSC handover, Ericsson MSC Only.
Ericsson MSC Parameter Only
The number of blocks within a multiframe where neither paging nor PSI messages shall appear.
TRXC can be regarded as the HW position for the element that is addressed by the parameter TEI.
The transmitter ID.
Page 27 of 27
Parameter
DMSUPP
DMTHAMR
DTHAMR
ABISALLOC
ALLOCPREF
ANT
ANTA
ANTB
BTDM
CBCHD
CRT
CTEI
DMQBNAMR
DMQGNAMR
DMTHNAMR
DTCB
DTCBHYST
DTCBSC
DTHNAMR
EGPRSBPCLIMIT
FBCHALLOC
FLEX64KGPRS
GTDM
HNDBEFOREBANSWM
HNDRELCHINTRAM
HNDSDCCHINTI
HNDSDCCHINTOM
HNDSDCCHM
HNDSDCCHTCHM
HNDTGSOPINTRA
LATAUSED
LIMIT1
LIMIT2
LIMIT3
LIMIT4
LISTTYPE
MAXLAPDM
Application Terminal Endpoint Identifier
Top Related