LIGHTING FIXTURES. REFER TO "LIGHTING FIXTURE SCHEDULE".
EMERGENCY LIGHTING FIXTURES. REFER TO "LIGHTING FIXTURE SCHEDULE".
ABBREVIATIONS
(NOT ALL ABBREVIATIONS ARE NECESSARILY
USED ON THIS PROJECT)
+ MOUNTING HEIGHT ABOVE FINISHED FLOOR
COORDINATE WITH ARCHITECTURAL PLANS
(E) EXISTING TO REMAIN
(ER) EXISTING TO BE REMOVED
(ERR) REMOVED & RELOCATED
(ERRO) REMOVED & RETURNED TO OWNER
(N) NEW
(RE) RELOCATED EXISTING
1P SINGLE POLE
2P TWO POLE
3P THREE POLE
A AMPERE
AF AMPERE FRAME
AFF ABOVE FINISHED FLOOR
AIC AMPERE INTERRUPTING CAPACITY
AT AMPERE TRIP
ATS AUTOMATIC TRANSFER SWITCH
AWG AMERICAN WIRE GAUGE
BLDG BUILDING
C CONDUIT
°C DEGREE CELSIUS
CB CIRCUIT BREAKER
CCTV CLOSED CIRCUIT TELEVISION
CD CANDELA
CL CEILING MOUNT
CKT CIRCUIT
CONT CONTINUATION
CU COPPER
DEG DEGREE
DIA DIAMETER
DISC DISCONNECT
DIV DIVISION
EA EACH
EC ELECTRICAL CONTRACTOR
ELEC ELECTRICAL
EM EMERGENCY
EMT ELECTRICAL METALLIC TUBING
°F DEGREE FAHRENHEIT
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FAAP FIRE ALARM ANNUNCIATOR PANEL
FATC FIRE ALARM TERMINATION CABINET
FC FOOT CANDLE
FDR FEEDER
FL FLOOR
FLA FULL LOAD AMPERES
FLEX FLEXIBLE
FMC FLEXIBLE METAL CONDUIT
G GROUND
GFI GROUND FAULT INTERRUPTER
GRC GALVANIZED RIGID CONDUIT
HP HORSE POWER
HZ HERTZ
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
JB JUNCTION BOX
KCMIL THOUSAND CIRCULAR MILS
KV KILOVOLT
KVA KILOVOLT AMPERE
KW KILOWATT
KWH KILOWATT HOUR
LTG LIGHTING
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MCM THOUSAND CIRCULAR MILS
MI MINERAL INSULATED CABLE
MTD MOUNTED
N NEUTRAL
NC NORMALLY CLOSED
NO NORMALLY OPEN
P POLE
PB PULL BOX
Ø PHASE
PNL PANEL
PVC POLYVINYL CHLORIDE CONDUIT
PWR POWER
REC RECEPTACLE
RMC RIGID METAL CONDUIT
SPD SURGE PROTECTION DEVICE
SPEC SPECIFICATION
SW SWITCH
SWBD SWITCHBOARD
SYS SYSTEMS
TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTED POWER SUPPLY
V VOLTS
VIF VERIFY IN FIELD
VFD VARIABLE FREQUENCY DRIVE
WP WEATHERPROOF
XFMR TRANSFORMER
Y WYE
Δ DELTA
VOICE / DATA SYMBOLS
RISER / SINGLE LINE SYMBOLS
POWER SYMBOLS
100/90/3
ATS
100A
480V,4P
208/120V
460V
500KVA
60/30/3
MOTOR RATED TOGGLE SWITCH, 20A SINGLE POLE, UON
HORSEPOWER RATED WITH OVERLOAD PROTECTION.
SINGLE POLE SWITCH
FLUSH WALL MOUNTED @ 48" AFF, UON
3 = THREE-WAY
4 = FOUR-WAY
D = INTEGRAL DIMMER
OS = INTEGRATED OCCUPANCY SENSOR
HOMERUN-NUMERAL WHERE USED INDICATES DESIGNATED PANEL AND CIRCUIT
NUMBER FOR REFERENCE ONLY. WHERE CONDUIT IS NOT SPECIFIED USE AC
OR MC CABLE FOR APPLICATION.
2#12, #12G, 3/4"C HOMERUN, UON
3#12, #12G, 3/4"C HOMERUN, UON
4#12, #12G, 3/4"C HOMERUN, UON
AT 120V AND OVER 100' CIRCUIT LENGTH PROVIDE #10 MINIMUM.
AT 277V AND OVER 200' CIRCUIT LENGTH PROVIDE #10 MINIMUM.
15 or 20A, 125V QUADRUPLEX RECEPTACLE, W/ ISOLATED GROUND
FLUSH WALL MOUNTED @ 18" AFF, UON
NUMBER INDICATES QUANTITIES OF IG TYPE RECEPTACLES.
1 = ONE DUPLEX IG TYPE & ONE DUPLEX STANDARD G. RECEPTACLE
2 = QUADRUPLEX IG TYPE RECEPTACLES
JUNCTION BOX
MOUNTED ABOVE SUSPENDED CEILING / FLUSH WALL
INSTALLED WITHIN 2' OF EQUIPMENT AND CONNECTED
VAV = DEDICATED TO VARIABLE AIR VOLUME BOX CONTROL
SD = DEDICATED TO SMOKE DAMPER
MD = DEDICATED TO MOTORIZED VOLUME DAMPER
UH = UNIT HEATER
EWC = ELECTRIC WATER COOLER
DMO = DOOR MOTOR OPERATOR
VOICE/DATA OUTLET
FLUSH WALL MOUNTED @ 18" AFF UON, WITH 3/4" CONDUIT IN DEMISING WALL,
TERMINATED IN A 90° BEND 6" INTO ACCESSIBLE CEILING
SPECIAL PURPOSE RECEPTACLE. NEMA TYPE AS INDICATED
FLUSH CEILING MOUNTED
20A, 125V QUADRUPLEX RECEPTACLE
FLUSH CEILING MOUNTED
20A, 125V DUPLEX RECEPTACLE
FLUSH CEILING MOUNTED
3 PHASE SPECIAL PURPOSE RECEPTACLE. NEMA TYPE AS INDICATED
FLUSH WALL MOUNTED @ 18" AFF, UON
SPECIAL PURPOSE RECEPTACLE. NEMA TYPE AS INDICATED
FLUSH WALL MOUNTED @ 18" AFF, UON
DROP CORD RECEPTACLE
CEILING MOUNTED
15 or 20A, 125V SURGE SUPPRESSION DUPLEX RECEPTACLE
FLUSH WALL MOUNTED @ 18" AFF, UON
15 or 20A, 125V DUPLEX RECEPTACLE CONTROLLED BY WALL SWITCH
FLUSH WALL MOUNTED @ 48" AFF, UON
20A, 125V, 2P W/G. SINGLE RECEPTACLE
FLUSH WALL MOUNTED @ 18" AFF, UON
EWC = ELECTRIC WATER COOLER
15 or 20A, 125V EMERGENCY QUADRUPLEX RECEPTACLE
FLUSH WALL MOUNTED @ 18" AFF, UON
15 or 20A, 125V EMERGENCY DUPLEX RECEPTACLE
FLUSH WALL MOUNTED @ 18" AFF, UON
15 or 20A, 125V DUPLEX RECEPTACLE
FLUSH WALL MOUNTED @ 18" AFF, UON
C = GRAY COLORED RECEPTACLE FOR COMPUTERS
T = TAMPER PROOF
XP = EXPLOSION PROOF
15 or 20A, 125V QUADRUPLEX RECEPTACLE
FLUSH WALL MOUNTED @ 18" AFF, UON
15 or 20A, 125V DUPLEX RECEPTACLE, GFI TYPE
FLUSH WALL MOUNTED @ 18" AFF, UON
WP = WEATHER PROOF
15 or 20A, 125V SINGLE RECEPTACLE, W/ ISOLATED GROUND
FLUSH WALL MOUNTED @ 18" AFF, UON
15 or 20A, 125V DUPLEX RECEPTACLE, W/ ISOLATED GROUND
FLUSH WALL MOUNTED @ 18" AFF, UON
TAPBOX, SPLICE BOX
CONDUIT OR RACEWAY TURNING UP
CONDUIT OR RACEWAY TURNING DOWN
CAPPED CONDUIT
CONDUIT WITH BUSHING
NEW UNDERGROUND/UNDER SLAB CONDUIT
SPLICE (JUNCTION) OF PATHS OF CONDUCTORS OR CABLES.
TRANSFORMER
COMBINATION MOTOR CONTROLLER / DISCONNECT SWITCH
<SWITCH AMPS>/<POLES>, VOLTAGE RATING AS REQUIRED
VFD = VARIABLE FREQUENCY DRIVE
UNFUSED DISCONNECT SWITCH
<SWITCH AMPS>/<POLES>, VOLTAGE RATING AS REQUIRED
FUSED DISCONNECT SWITCH
<SWITCH AMPS>/<FUSE AMPS>/<POLES>, VOLTAGE RATING AS REQUIRED
ENCLOSED CIRCUIT BREAKER
<FRAME AMPS>/<TRIP AMPS>/<POLES>, VOLTAGE RATING AS REQUIRED
ST = SHUNT TRIP
208/120V PANELBOARD
SURFACE MOUNTED
208/120V PANELBOARD
FLUSH MOUNTED
208/120V DISTRIBUTION PANELBOARD
SURFACE MOUNTED
480/277V PANELBOARD
SURFACE MOUNTED
480/277V PANELBOARD
FLUSH MOUNTED
480/277V DISTRIBUTION PANELBOARD
SURFACE MOUNTED
MOTOR
GENERATOR
GROUND CONNECTION
TRANSFER SWITCH
ATS = AUTOMATIC TRANSFER
MTS = MANUAL TRANSFER
POLES AND RATING AS NOTED
POWER TRANSFORMER
VOLTAGES, WINDINGS AND SIZE AS INDICATED
CIRCUIT BREAKER - MOLDED CASE TYPE
<FRAME AMPS>/<TRIP AMPS>/<POLES>
CURRENT TRANSFORMER
FLOOR MOUNTED METAL SUPPORT FRAME FOR ELECTRICAL ENCLOSURES
NEW LOW VOLTAGE/CONTROL WIRING
VFD
ANNOTATION SYMBOLS
KEY NOTE
EQUIPMENT PROVIDED BY OTHERS
ST
NEW GROUND CABLE
100/3
30/3
100/60/3
NEW CONDUIT/CIRCUIT/EQUIPMENT
ELECTRICAL SYMBOLS LIST
(NOT ALL SYMBOLS ARE NECESSARILY USED ON THIS PROJECT)
20/1
GENERAL NOTES
1. THE SUBMISSION OF A BID BY THE ELECTRICAL CONTRACTOR IS NOTIFICATION THAT THE ELECTRICAL
CONTRACTOR HAS TOTALLY FAMILIARIZED HIMSELF WITH THE CONTRACT DOCUMENTS AND EXISTING SITE
CONDITIONS AND HAS AGREED TO PROVIDE THE NECESSARY LABOR AND MATERIAL FOR THE COMPLETE
INSTALLATION OF EACH SYSTEM IN A NEAT AND WORKMANLIKE MANNER IN ACCORDANCE WITH THE BEST
PRACTICES OF THE INDUSTRY AND IN COMPLIANCE WITH ALL AUTHORITIES HAVING JURISDICTION.
2. THESE DRAWINGS ARE PRESENTED TO THE ELECTRICAL CONTRACTOR WITH THE UNDERSTANDING THAT
THE ELECTRICAL CONTRACTOR IS AN EXPERT AND COMPETENT IN THE PREPARATION OF CONTRACT BID
PRICES ON THE BASIS OF INFORMATION SUCH AS IS CONTAINED IN THESE DOCUMENTS. IT IS THE INTENT
OF THE DRAWINGS AND SPECIFICATIONS TO CALL FOR FINISHED WORK, TESTED AND READY FOR
OPERATION AND IN COMPLETE CONFORMANCE WITH ALL APPLICABLE CODES, RULES, AND REGULATIONS.
MINOR ITEMS NOT USUALLY SHOWN OR SPECIFIED, BUT MANIFESTLY NECESSARY FOR THE PROPER
INSTALLATION AND OPERATION OF THE VARIOUS SYSTEMS, SHALL BE INCLUDED IN THE WORK AND IN THE
PROPOSAL THE SAME AS IF SPECIFIED OR SHOWN ON THE DRAWINGS. IF ANY DEPARTURES FROM THE
DRAWINGS ARE DEEMED NECESSARY, DETAILS OF SUCH DEPARTURES AND THE REASONS THEREFORE
SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL. NO DEPARTURES SHALL BE MADE WITHOUT
PRIOR APPROVAL OF SEPTA.
3. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND VERIFY ALL DIMENSIONS IN THE FIELD, AND SHALL
ADVISE THE PROJECT MANAGER AND THE OWNER OF ANY DISCREPANCIES BEFORE PERFORMING THE
WORK.
4. THE DRAWINGS INDICATE ARRANGEMENTS AND APPROXIMATE SIZES AND RELATIVE LOCATIONS OF
PRINCIPAL APPARATUS, EQUIPMENT, DEVICES, AND SERVICES TO BE PROVIDED. DRAWINGS ARE
DIAGRAMMATIC AND ARE A GRAPHIC REPRESENTATION OF CONTRACT REQUIREMENTS TO THE BEST
AVAILABLE STANDARDS AT THE SCALE INDICATED.
5. LAYOUT OF EQUIPMENT INDICATED ON THE DRAWINGS SHALL BE CHECKED AND COMPARED AGAINST ALL
DRAWINGS AND SPECIFICATIONS OF ALL TRADES AND EXACT LOCATIONS DETERMINED USING APPROVED
SHOP DRAWINGS OF SUCH EQUIPMENT. WHERE PHYSICAL INTERFERENCES OCCUR, CONSULT WITH THE
PROJECT MANAGER AND PREPARE DATED, DIMENSIONED DRAWINGS COORDINATED WITH ALL OTHER
TRADES WORKING IN THIS AREA AND CORRECTING SUCH INTERFERENCE.
6. ELECTRICAL CONTRACTOR SHALL SCHEDULE HIS WORK IN ACCORDANCE WITH THE CONSTRUCTION
SCHEDULE SO THAT ALL OF HIS WORK CAN BE INSTALLED WITHOUT DELAYING THE PROJECT. ALL WORK
RELATED TO SHUTDOWN OF EXISTING SERVICES SHALL BE PERFORMED AT THE HOURS DESIGNATED BY
SEPTA WITH ALL ASSOCIATED COSTS BORNE BY THE ELECTRICAL CONTRACTOR AT NO COST TO SEPTA.
PROVIDE ANY TEMPORARY FACILITIES REQUIRED TO PERMIT SEPTA'S USE OF EXISTING FACILITIES AND
SYSTEMS TO REMAIN UNDISTURBED. COORDINATE ALL WORK, INCLUDING ALL SHUTDOWNS THAT AFFECT
SYSTEMS AND/OR PORTIONS OF THE BUILDING THAT MUST REMAIN IN OPERATION, WITH SEPTA.
7. ELECTRICAL CONTRACTOR SHALL SECURE AND PAY ALL FEES, LICENSES, INSPECTIONS, AND PERMITS
PERTAINING TO THE CONTRACT. SUBMIT TO SEPTA DUPLICATE CERTIFICATES OF INSPECTION FROM
APPROVED INSPECTION AGENCY.
8. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT COMPLIANCE WITH THE MANUFACTURER'S WRITTEN
INSTRUCTIONS.
9. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR WORKMEN'S IDENTIFICATION AND BADGING,
SAFETY AND FIRE PROTECTION, BARRICADES, WARNING SIGNS, TRASH REMOVAL, CUTTING AND
PATCHING.
10. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL RIGGING, HANDLING, AND PROTECTION OF
MATERIALS. ALL EQUIPMENT AND MATERIALS SHALL BE NEW AND WITHOUT BLEMISH OR DEFECT. ALL
EQUIPMENT INSTALLED SHALL BEAR THE LABEL OF AN APPROVED AGENCY.
11. ELECTRICAL CONTRACTOR SHALL PROVIDE LABOR TO RECEIVE, UNLOAD, STORE, PROTECT, AND
TRANSFER TO POINT OF INSTALLATION FOR ALL FURNISHED ITEMS.
12. WHERE CONDUIT, CABLES, DUCTWORK, OR PIPING PASSES THROUGH FIRE RATED FLOORS OR WALLS, THE
PENETRATION SHALL BE COMPLETELY SEALED WITH A FIRE STOP MATERIAL THAT IS UL LISTED, FM
GLOBAL APPROVED (WWW.FMGLOBAL.COM/PAGE.ASPX?ID=50030000) AND ACCEPTED BY THE BUILDING
DEPARTMENT AND FIRE DEPARTMENT AS BEING SUITABLE FOR THIS SERVICE. THIS MATERIAL SHALL BE
INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE MANUFACTURER TO MAINTAIN THE UL
LISTED FIRE RATING OF THE PENETRATED WALL OR FLOOR.
13. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SLAB OPENINGS, WALL OPENINGS, BEAM
PENETRATIONS, AND CORING AS IT RELATES TO HIS WORK. ELECTRICAL CONTRACTOR SHALL SUBMIT SIZE
AND LOCATION FOR REVIEW AND APPROVAL.
14. ALL EXTERIOR WALL OPENINGS SHALL BE SLEEVED, PROPERLY CAULKED, AND SEALED WITH A HIGH
QUALITY SEALANT TO PREVENT INFILTRATION OF MOISTURE AND OUTSIDE AIR.
15. CONTRACTOR SHALL SUBMIT SCHEDULE OF SUBMITTALS PRIOR TO SUBMITTING ANY SHOP DRAWINGS,
ETC. TO BE SUBMITTED FOR THIS PROJECT, INCLUDING THE ANTICIPATED DATE OF EACH SUBMISSION.
CONTRACTORS SHALL SUBMIT (6) SETS OF COMPLETE SHOP DRAWINGS AND CATALOG CUTS, WIRING
DIAGRAMS AND ASSOCIATED DATA TO THE PROJECT MANAGER FOR APPROVAL PRIOR TO PURCHASING
EQUIPMENT OR STARTING ANY WORK. ANY WORK INSTALLED OR EQUIPMENT PURCHASED PRIOR TO
RECEIPT OF PROJECT MANAGER APPROVED SHOP DRAWINGS THAT REQUIRES CHANGES SHALL BE
REPLACED AT CONTRACTOR'S EXPENSE.
16. SUBMIT CATALOG INFORMATION, FACTORY ASSEMBLY DRAWINGS AND FIELD INSTALLATION DRAWINGS AS
REQUIRED FOR A COMPLETE EXPLANATION AND DESCRIPTION OF ALL ITEMS TO BE PROVIDED. THE
ELECTRICAL CONTRACTOR SHALL REVIEW AND APPROVE ALL SHOP DRAWINGS. NO SUBMISSION WILL BE
ACCEPTED WITHOUT THE SIGNED APPROVAL OF THE ELECTRICAL CONTRACTOR. THE ELECTRICAL
CONTRACTOR SHALL CHECK AND VERIFY ALL FIELD MEASUREMENTS.
17. UPON COMPLETION OF CONSTRUCTION, CONTRACTOR SHALL SUPPLY THE PROJECT MANAGER WITH (1)
COMPLETE SET OF CAD AS-BUILT DRAWINGS IN AUTOCAD 2000 AT CONTRACTOR'S EXPENSE AND (3)
COMPLETE BOUND COPIES OF OPERATION AND MAINTENANCE MANUALS. THESE SHALL BE PROVIDED TO
SEPTA AT CONTRACTOR'S EXPENSE. CONTRACTOR SHALL INSTRUCT SEPTA'S PERSONNEL WITH REGARD
TO THE PROPER OPERATION OF ALL SYSTEMS TO THE SATISFACTION OF SEPTA.
18. ALL WORK FURNISHED UNDER THE CONTRACT SHALL BE GUARANTEED AGAINST ANY AND ALL DEFECTS IN
WORKMANSHIP AND/OR MATERIALS FOR A PERIOD OF NOT LESS THAN (1) YEAR FROM THE DATE OF FINAL
ACCEPTANCE OF THE INSTALLATION. ANY DEFECTS OF WORKMANSHIP DEVELOPING DURING THIS PERIOD
SHALL BE REMEDIED AND ANY DEFECTIVE MATERIAL REPLACED WITHOUT ADDITIONAL COST TO SEPTA.
19. INSTALLED SYSTEMS SHALL OPERATE UNDER ALL CONDITIONS OF LOAD WITHOUT SOUND OR VIBRATION
THAT IS OBJECTABLE TO THE PROJECT MANAGER, OR SEPTA. OBJECTABLE SOUND OR VIBRATION
CONDITIONS DUE TO WORKMANSHIP SHALL BE CORRECTED IN APPROVED MANNER BY THE ELECTRICAL
CONTRACTOR AT HIS EXPENSE.
20. ELECTRICAL CONTRACTOR SHALL SIMILARLY NOTIFY ENGINEER OF COMPLETION OF ALL WORK,
INDICATING THE ELECTRICAL CONTRACTOR IS READY FOR THE ENGINEER TO PERFORM THE FINAL
PUNCHLIST INSPECTION.
21. UPON COMPLETION OF ALL UNFINISHED OR FAULTY WORK NOTED IN ENGINEER FINAL PUNCH LIST, THE
ELECTRICAL CONTRACTOR SHALL SUBMIT TO THE ENGINEER IN WRITING A LETTER OF COMPLETION
CERTIFYING THAT ALL PUNCH LIST ITEMS HAVE BEEN COMPLETED AND ALL AS-BUILTS, MANUALS, ETC.
HAVE BEEN SUBMITTED.
22. SHOULD A CONTRACTOR REQUIRE REMOVAL, RELOCATION, OR REROUTING OF ANOTHER TRADE'S WORK
THAT IS NOT INDICATED ON DRAWINGS, THE CONTRACTOR REQUIRING SUCH WORK SHALL BE
RESPONSIBLE FOR THAT WORK, AND PAY ALL REQUIRED COSTS.
23. ALL WORK INVOLVING ALTERATIONS TO EXISTING SYSTEMS, EQUIPMENT, AND MATERIALS SHALL BE
REVIEWED WITH THE PROJECT MANAGER AND SEPTA BEFORE BEGINNING WORK.
24. DEFINITION: UNLESS OTHERWISE NOTED, ALL WORK SPECIFIED HEREIN OR NOTED ON DRAWINGS, SHALL
BE BY THE ELECTRICAL CONTRACTOR. ALL REFERENCES TO "CONTRACTOR" OR "THIS CONTRACTOR" ON
DRAWINGS OR SPECIFICATIONS ARE ADDRESSED TO THE ELECTRICAL CONTRACTOR. THE TERM
"PROVIDE" WHENEVER ENCOUNTERED ON DRAWINGS OR IN THESE SPECIFICATIONS, SHALL MEAN
"FURNISH AND INSTALL."
25. CODES AND STANDARDS: ALL MATERIALS AND WORKMANSHIP SHALL COMPLY WITH THE NATIONAL
ELECTRIC CODE, ALL APPLICABLE CODES, SPECIFICATIONS, LOCAL ORDINANCES, INDUSTRY STANDARDS,
UTILITY COMPANY REGULATIONS AND FIRE INSURANCE CARRIER'S REQUIREMENTS.
26. MATERIALS: ALL MATERIALS FURNISHED BY THIS CONTRACTOR, SHALL BE NEW AND BEAR THE LABEL OR
LISTING OF A NATIONALLY RECOGNIZED INDEPENDENT TESTING LABORATORY.
27. OUTLET AND SWITCH BOXES: PROVIDE AND INSTALL OUTLET BOXES OF PROPER TYPE AND SIZE AS
REQUIRED AT ALL OUTLETS WHERE SHOWN. SECURED FIRMLY IN PLACE AND SET TRUE AND SQUARE AND
FLUSH WITH THE FINISHED SURFACE.
28. INSTALLATION OF RACEWAYS: ALL RACEWAYS SHALL BE INSTALLED CONCEALED. NO SURFACE RACEWAY
WILL BE ACCEPTED IN FINISHED AREAS.
29. WIRING: WIRING OF BRANCH CIRCUITS SHALL BE TYPE THHN/THWN IN RIGID GALVANIZED STEEL CONDUIT
WHERE EXPOSED OUTSIDE. WIRES SHALL BE COPPER AND SHALL BE MIN. #12AWG, 600V, 75°C. ALL
RACEWAYS ARE SHOWN DIAGRAMMATICALLY, EXACT LOCATION TO BE DETERMINED ON THE JOB. EXACT
LOCATION OF OUTLETS TO BE DETERMINED BY SEPTA. CONTRACTOR SHALL ARRANGE ALL NEW CIRCUITS
IN PANELS SO AS TO BALANCE THE LOAD ON ALL PHASES. EXPOSED CONDUIT IN UNFINISHED AREAS
SHALL BE EMT. CONDUIT DIRECTLY BURIED UNDERGROUND SHALL BE SCHEDULE 40 PVC WITH RGS
ELBOWS AND STUB UPS.
30. A TYPED DIRECTORY CARD SHALL BE PROVIDED IN EACH PANEL WITH ADDED CIRCUITS TO INDICATE THE
LOADS ACTUALLY SERVED.
31. PROVIDE NEW FIXTURES AS SPECIFIED ON LIGHTING FIXTURE SCHEDULE. ALL NEW LED LAMPS SHALL BE
3500K.
32. GROUNDING: SHALL BE IN STRICT ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE ARTICLE 250.
PROVIDE GROUND WIRES AS REQUIRED AND RESIZE CONDUIT IF NECESSARY.
33. DEMONSTRATION OF COMPLETE ELECTRICAL SYSTEMS: UPON COMPLETION OF THE WORK THIS
CONTRACTOR SHALL OBTAIN A CERTIFICATE OF APPROVAL FROM ALL RECOGNIZED AGENCIES
CONCERNED WITH THE WORK. CONTRACTOR SHALL NOTIFY AND MAKE ALL THE NECESSARY
ARRANGEMENTS WITH THE INSPECTING AGENCY AND LOCAL AUTHORITIES SO THAT INSPECTION MAY BE
CARRIED OUT AT THE PROPER TIME.
34. PROJECT MUST MEET FM GLOBAL STANDARDS (WWW.FMGLOBAL.COM/)
METER
LIGHTING SYMBOLS
JUNCTION BOX OR POKE-THRU WITH COMBINATION POWER/DATA
FLUSH FLOOR MOUNTED REFER TO DETAIL ON DRAWING E002
NEW EMERGENCY CIRCUIT
UNDERGROUND SECONDARY CABLE
SHOWN HERE FOR REFERENCE ONLY. SEE CIVIL PLANS
UNDERGROUND TELEPHONE CABLE
SHOWN HERE FOR REFERENCE ONLY. SEE CIVIL PLANS
OCCUPANCY SENSOR. 360° RANGE
CEILING MOUNTED
PHOTOCELL CONTROL SWITCH
CEILING MOUNTED
PHOTOCELL CONTROL SWITCH
WALL MOUNTED @ 10" BELOW FINISHED CEILING
ELECTRICALLY HELD UL LISTED RELAY FOR EMERGENCY LIGHTING.
LIGHTING SHALL BE CONTROLLED BY SWITCH UNDER NORMAL POWER
CONDITION FROM NORMAL SOURCE. IN EMERGENCY MODE THE RELAY
SHALL ENABLE THE DEDICATED LIGHTING TO BE SWITCHED TO THE
EMERGENCY SOURCE FOR FULL OPERATION. PROVIDE BODINE BALLAST
#GTD OR SIMILIAR.
TIME CLOCK
MANHOLE
ELECTRICALLY HELD UL LISTED RELAY FOR EMERGENCY LIGHTING.
LIGHTING SHALL BE CONTROLLED BY SWITCH UNDER NORMAL POWER
CONDITION FROM NORMAL SOURCE. IN EMERGENCY MODE THE RELAY
SHALL ENABLE THE DEDICATED LIGHTING TO BE SWITCHED TO THE
EMERGENCY SOURCE FOR FULL OPERATION. PROVIDE BODINE BALLAST
#GTD OR SIMILIAR.
ELECTRIC DOOR STRIKE
CARD READER, PROVIDE 2"x4" JUNCTION BOX
WALL MOUNTED @ 42" AFF UON ON NON-SECURED SIDE OF DOOR
ADA ACCESS BUTTON, MAKE ALL FINAL CONNECTIONS TO DOOR CONTROLLER
DOOR CONTROLLER
SHEET NUMBER
DWG. NO.:
OF
OF
SHT. NO.:
REV. NO.:
SCALE:
DRAWN BY:DATE:
WORK ORDER NO.:
SCALE FACTOR:
CHECKED BY:
ARCHIVE NO.:
COMPUTER FILE NO.:
AD
DE
ND
UM
1
4/1
7/1
51
MA
NC
WT
CW
T
MDP
REF.
REF.REF.REF.
+ +
+
+
+
+
+
+
ELECTRIC WH-2
1.5KVA, 120V
ELECTRIC WH-2
1.5KVA, 120V
ELECTRIC WH-2
1.5KVA, 120V
TRAP PRIMER TP-1
120V
T75K
LP2
TELEPHONE
4'x4' PLYWOOD
WP
WP
WP
WP
GAS WATER HEATER
RE-CIRC PUMP 120V
SD
VAV
VAV
VAV
VAV
VAV
VAV
VAV
VAV
VAV
VAV
VAV
VAV
+
+
CEILING FAN
CEILING FAN
CEILING FAN
BMS PANEL
120V
PUMP P-1
1.5HP,480V,3Φ
PUMP P-2
1.5HP,480V,3Φ
REFRIGERATOR
120V
C
C
C
C
C
C
1"C FOR DATA
1"C FOR POWER
LP1
LP1
6
4
HP1
HP1
1
2
1
LP1
LP1
3
7
LP1
LP2
LP1
LP2
2
LP2
LP2
LP1
LP2
LP2
LP2
LP2
LP2
LP2
LP2
LP2
LP2
LP2
LP2
LP1
LP2
LP2
LP2
2
11
LP2
6
8
19
12 13
15
14
16
18
20
LP2
LP1LP2
LP2LP2 LP2
LP2
LP1
23
10
1
3
5
7
15
17
21
23
19
LP2
25
LP2
32
22 24 2628 30
17
4
MD
MD
UH-1
UH-2
LP2
27
REC
ON
ROOF
EF-4
1/25HP,120V
EF-3
1/30HP,120V
5
LP1
BOILER CONTROLS
120V
21
LP2
1"C FOR DATA
3/4"C FOR POWER
TOILET (TYP 11)
50VA, 120V
TOILET (TYP 3)
50VA, 120V
SINK
35VA,120V
SINKS
100VA, 120V
SINKS
100VA, 120V
12
LP1
LP1
10
LP1
14
+
EWC
LP1
16
EWC
LP1
18
UP TO
CU-1
AC-1
208V,1Φ
LP2
LP1
LP1
25
CEILING FAN (TYP 4)
5.7A,120V
BURIED CONDUIT FOR TELE/DATA
REFER TO DRAWING E102 FOR CONTINUATION
CB-1
HP1
CT
TROUGH
ABOVE
LP1
MD
MD
MD
MD
LP1
VIDEO MONITORS, +48" (TYP 9)
120V & DATA
LP2
34
KIOSK & PRINTER
CONDESATE PUMP
120V
LP1
26
PRINTER/COPIER
LP2
29
27
LP1
LP1
29
HAND DRYER
1500VA, 120V
31
LP1
LP1
33
HAND DRYER
1500VA, 120V
CR
CR
CR
SECURITY
PANEL
CR
CR
DMO
DMO
DMO
LP1
28
TYP
TYP
LP1
30
LP1
32
TYP
TYP
SHEET NUMBER
DWG. NO.:
OF
OF
SHT. NO.:
REV. NO.:
SCALE:
DRAWN BY:DATE:
WORK ORDER NO.:
SCALE FACTOR:
CHECKED BY:
ARCHIVE NO.:
COMPUTER FILE NO.:
KEY NOTES
DATA ROOM'S AIR CONDITIONER & CONDENSING UNIT
POWERED THROUGH SINGLE POINT AT CONDENSING UNIT.
EXTEND CONDUIT/WIRE TO AIR CONDITIONER.
HANDS-FREE TOILET REQUIRES 120V. MOUNT IN LOCATION
RECOMMENDED BY MANUFACTURER. TOILET PROVIDED BY
OTHERS WITH LOW-VOLTAGE TRANSFORMER.
HANDS-FREE SINK REQUIRES 120V RECEPTACLE. SINK
PROVIDED BY OTHERS WITH LOW-VOLTAGE PLUG-IN
TRANSFORMER.
HANDS-FREE SINKS REQUIRES 120V. MOUNT JUNCTION BOX
BELOW SINK. SINK PROVIDED BY OTHERS WITH
LOW-VOLTAGE 100VA TRANSFORMER.
OUTLET IDENTIFICATION NUMBERING SHALL BE AS DIRECTED
BY OWNER'S M.I.S. DEPARTMENT INSTALLATION SHALL
COMPLY WITH SPECIFICATIONS. EACH CABLING SHALL BE
TAGGED AT ALL TERMINATIONS POINTS.
STANDARD OUTLET MOUNTING HEIGHT SHALL BE THE SAME
AS ELECTRICAL HEIGHT, U.O.N. EXACT LOCATION OF
OUTLETS SHALL BE AS INDICATED ON THE ARCHITECTURAL
DRAWINGS.
EQUIPMENT AND/OR CABLE LOCATED AT THIS STAGE OF THE
TELECOMMUNICATIONS CABLING CONFIGURATION IS EITHER
EXISTING OR NOT COVERED UNDER THIS CONTRACT AND
WILL BE FURNISHED BY OTHERS.
LABEL ALL RACKS, FRAMES, CABINETS, BLOCKS, CABLES,
CABLE SUPPORTS, ETC. IN ACCORDANCE WITH EIA/TIA 606.
TELECOMMUNICATIONS INSTALLATION SHALL COMPLY WITH
ALL CURRENT APPLICABLE CODES, INCLUDING
PHILADELPHIA ELECTRICAL CODES, THE NATIONAL ELECTRIC
CODE, AND ALL APPLICABLE LOCAL CODES HAVING
JURISDICTION.
PROVIDE FIRESTOPPING FOR ALL SLEEVE AND CONDUIT
PENETRATIONS THROUGH RATED PARTITIONS OR FLOORS IN
ACCORDANCE WITH THE SPECIFICATIONS.
TELECOMMUNICATION NOTES
DEDICATED RECEPTACLE FOR ELECTRIC WATER HEATER TO
BE MOUNTED UNDER SINK. LABEL FACEPLATE "FOR WATER
HEATER".
PROVIDE 120V:24V TRANSFORMER FOR LOW VOLTAGE
DAMPER.
PROVIDE 120V:24V TRANSFORMER FOR LOW VOLTAGE
DAMPER.
PROVIDE SECURITY PANEL, TYCO INTEGRATED SECURITY
ACE8/SWH-1 OR SEPTA APPROVED EQUAL
PROVIDE TWO CAT 6 CABLES IN A 1" EMT CONDUIT HOMERUN
BACK TO THE SECURITY PANEL IN THE COMM ROOM AND
SAFE OFF BOTH ENDS.
WIRE ALL ADA ACCESS BUTTONS TO CIRCUIT LP1#34
AD
DE
ND
UM
1
4/1
7/1
51
MA
NC
WT
CW
T
MECHANICAL EQUIPMENT PAD
SKYLIGHT
SKYLIGHT
SKYLIGHT
SKYLIGHT
WALKING PAD, TYP.
WALKING PAD, TYP.
SKYLIGHT
SKYLIGHT
EXHAUST FAN EF-1
1/4HP, 120V
ROOFTOP UNIT RTU-1
85MCA, 480V,3Φ
15HP SUPPLY FAN
(3)11.2A COMPRESSORS
(3)2A CONDENSORS
CU-1
208V,1Φ
100/100/3
WP
WP
MDP
3
LP1
9
REC CIRCUIT
LP2#2 BELOW
DOWN TO AC
SHEET NUMBER
DWG. NO.:
OF
OF
SHT. NO.:
REV. NO.:
SCALE:
DRAWN BY:DATE:
WORK ORDER NO.:
SCALE FACTOR:
CHECKED BY:
ARCHIVE NO.:
COMPUTER FILE NO.:
EXHAUST FAN PROVIDED WITH DISCONNECT AND OVERLOAD
PROTECTION BY OTHERS.
DATA ROOM'S AIR CONDITIONER & CONDENSING UNIT
POWERED THROUGH SINGLE POINT AT CONDENSING UNIT.
EXTEND CONDUIT/WIRE TO AIR CONDITIONER.
KEY NOTES
480/277
PANEL LP1 VIA TRANSFORMER 2125
DESCRIPTION OF LOAD
PER PHASE
A B C
LOADLOAD
4
FCU-2 620
FCU-4 820
SPACE 10-
SPACE 12-
SPACE 14-
AMPS
TRIP
NO.
CKT.
1 150
3 100
5 20
7 20
9 -
11 -
13 -
AMPS
TRIP
NO.
CKT.
PANEL HP1
ROOFTOP UNIT RTU-1
FCU-1
FCU-3
SPACE
SPACE
SPACE
PANEL:
FEEDER SIZE:
FED FROM:
BUILDING:
LOCATION:MOUNTING:
MDP
NEUTRAL:
VOLTS, PHASE, WIRE4
32,000AIC:
400MAIN BUS: AMPS
AMPSMAIN BRK: P3
BUS: COPPER ALUMINUM
SURFACE FLUSH
MANUFACTURER/MODEL:
AMPS100%
ELECTRICAL ROOM 130
FRANKFORD ADMINISTRATION BUILDING
REFER TO SINGLE LINE ON DRAWING E002
REFER TO SINGLE LINE ON DRAWING E002
REFER TO SPECIFICATIONS
3
400
(KVA)
(KVA)(KVA)
DESCRIPTION OF LOAD
ISOLATED GROUND
GROUND
LUGS:
FEED THRU MLO
FEED: TOP BOTTOM
SHUNT TRIP
ARC FLASH HAZARD CATEGORY:
NEMA ENCLOSURE TYPE:
2
1
REC MECH RM, EXTERIOR220
(KVA)
PER PHASE
A B (KVA)C
LOAD
(KVA)
LOAD
REC 112A, ELEC RM, C102420
REC 108, 110620
COMPUTER REC 102, 104, 106, 108, 110820
REC 102, 104, 1061020
REC RESTROOMS 111, 1131220
REC KITCHEN1420
REC KITCHEN1620
REC KITCHEN1820
REFRIGERATOR 1092020
22
HEATERS 130,131, DAMPERS 2420
CONDESATE PUMP 2620
DOOR CONTROLLER 2820
DOOR CONTROLLER 3020
DOOR CONTROLLER 3220
ADA DOOR ASSIST BUTTONS 3420
SPARE 3620
SPARE 3820
SPARE 4020
SPARE 4220
AMPS
TRIP
NO.
CKT.
1 20
3 20
5 20
7 20
9 20
11 20
13 20
15 20
17 20
19 20
21 20
23 20
25 20
27 20
29 20
31 20
33 20
35 20
37 20
39 20
41 20
AMPS
TRIP
NO.
CKT.
BMS PANEL
BOILER CONTROLS
TRAP PRIMER TP-2
RE-CIRC PUMP
EXHAUST FAN EF-1 (1/4HP)
EXHAUST FAN EF-2 (1/6HP)
WATER HEATER WH-2
WATER HEATER WH-2
WATER HEATER WH-2
VAV CONTROLLERS
VAV CONTROLLERS
CEILING FANS 120
CEILING FANS 120
HAND DRYER WOMENS RESTROOM
HAND DRYER WOMENS RESTROOM
HAND DRYER MENS RESTROOM
HAND DRYER MENS RESTROOM
SPARE
SPARE
SPARE
SPARE
PANEL:
FEEDER SIZE:
FED FROM:
BUILDING:
LOCATION:
MOUNTING:
LP1
VOLTS, PHASE, WIRE208/120 4
BUS: COPPER ALUMINUM
SURFACE FLUSH
MANUFACTURER/MODEL:
ELECTRICAL ROOM 130
REFER TO SPECIFICATIONS
3
DESCRIPTION OF LOAD DESCRIPTION OF LOAD
NEUTRAL:10,000
AIC:
250MAIN BUS: AMPS
AMPSMAIN BRK: P3
AMPS200%
250
ISOLATED GROUND
GROUND
LUGS:
FEED THRU MLO
FEED: TOP BOTTOM
SHUNT TRIP
ARC FLASH HAZARD CATEGORY:
NEMA ENCLOSURE TYPE:
1
1
480/277
PUMP P-2 (1.5HP) 215
DESCRIPTION OF LOAD
PER PHASE
A B C
LOADLOAD
4
6
8
10
12
SPARE 1420
SPARE 1620
SPARE 1820
SPACE 20-
SPACE 22-
SPACE 24-
SPACE 26-
SPACE 28-
SPACE 30-
SPACE 32-
SPACE 34-
SPACE 36-
SPACE 38-
SPACE 40-
SPACE 42-
AMPS
TRIP
NO.
CKT.
1 15
3
5
7 20
9 20
11 20
13 20
15 20
17 20
19 20
21 20
23 20
25 -
27 -
29 -
31 -
33 -
35 -
37 -
39 -
41 -
AMPS
TRIP
NO.
CKT.
PUMP P-1 (1.5HP)
LIGHTING
LIGHTING
LIGHTING
LIGHTING
LIGHTING
SPARE
SPARE
SPARE
SPARE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
SPACE
PANEL:
FEEDER SIZE:
FED FROM:
BUILDING:
LOCATION:MOUNTING:
HP1
NEUTRAL:
VOLTS, PHASE, WIRE4
14,000AIC:
150MAIN BUS: AMPS
AMPSMAIN BRK: P3
BUS: COPPER ALUMINUM
SURFACE FLUSH
MANUFACTURER/MODEL:
AMPS100%
ELECTRICAL ROOM 130
REFER TO SPECIFICATIONS
3
MLO
(KVA)
(KVA)(KVA)
DESCRIPTION OF LOAD
ISOLATED GROUND
GROUND
LUGS:
FEED THRU MLO
FEED: TOP BOTTOM
SHUNT TRIP
ARC FLASH HAZARD CATEGORY:
NEMA ENCLOSURE TYPE:
2
1
220
(KVA)
PER PHASE
A B (KVA)C
LOAD
(KVA)
LOAD
420
620
820
1020
1220
1420
1620
1820
2020
REFRIGERATOR 120 2220
REFRIGERATOR 120 2420
REFRIGERATOR 120 2620
REC 120 2820
REC 120 3020
VIDEO MONITORS 120 3220
VIDEO MONITORS 120 3420
SPARE 3620
SPARE 3820
SPARE 4020
SPARE 4220
AMPS
TRIP
NO.
CKT.
1 20
3 20
5 20
7 20
9 20
11 20
13 20
15 20
17 20
19 20
21 20
23 20
25 20
27 20
29 20
31 20
33 20
35 20
37 20
39 20
41 20
AMPS
TRIP
NO.
CKT.
REC 120
REC 120, 125, 126, C103
REC 101A, 101B, 107, EXTERIOR
PRINTER/COPIER
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
PANEL:
FEEDER SIZE:
FED FROM:
BUILDING:
LOCATION:
MOUNTING:
LP2
VOLTS, PHASE, WIRE208/120 4
BUS: COPPER ALUMINUM
SURFACE FLUSH
MANUFACTURER/MODEL:
ELECTRICAL ROOM 130
REFER TO SPECIFICATIONS
3
DESCRIPTION OF LOAD DESCRIPTION OF LOAD
NEUTRAL:10,000
AIC:
250MAIN BUS: AMPS
AMPSMAIN BRK: P3
AMPS200%
MLO
ISOLATED GROUND
GROUND
LUGS:
FEED THRU MLO
FEED: TOP BOTTOM
SHUNT TRIP
ARC FLASH HAZARD CATEGORY:
NEMA ENCLOSURE TYPE:
1
1
FRANKFORD ADMINISTRATION BUILDING
REFER TO SINGLE LINE ON DRAWING E002
REFER TO SINGLE LINE ON DRAWING E002
FRANKFORD ADMINISTRATION BUILDING
REFER TO SINGLE LINE ON DRAWING E002
REFER TO SINGLE LINE ON DRAWING E002
FRANKFORD ADMINISTRATION BUILDING
REFER TO SINGLE LINE ON DRAWING E002
REFER TO SINGLE LINE ON DRAWING E002
TELEPHONE BOARD REC
SMOKE DAMPERS
DAMPERS, EF-5, EF-6
HANDS-FREE MENS RESTROOM
HANDS-FREE WOMENS RESTROOM
HANDS-FREE RESTROOMS 111 & 113
ELECTRIC WATER COOLER KITCHEN
ELECTRIC WATER COOLER LOUNGE
REC SERVER ROOM
REC SERVER ROOM
REC SERVER ROOM
REC SERVER ROOM
SPARE
REC RESTROOMS 122, 124
SPARE
REC C101, 100, EXTERIOR
REC 101
REC 101
REC 101
FIRE ALARM CONTROL PANEL
SPARE 20
SPARE 20
SPARE 20
SPACE -
AIR CONDITIONER & CONDENSING UNIT
DATA ROOM
KEY NOTES
PROVIDE 3#12, #12G, 3/4"C
REFER TO SINGLE LINE DIAGRAM ON DRAWING E002 FOR
FEEDER SIZE.
SHEET NUMBER
DWG. NO.:
OF
OF
SHT. NO.:
REV. NO.:
SCALE:
DRAWN BY:DATE:
WORK ORDER NO.:
SCALE FACTOR:
CHECKED BY:
ARCHIVE NO.: