SAFETY AND MAINTENANCE SOLUTIONS FOR NETWORK ELECTRICIANS
GENERAL PRESENTATION
■ THE NOVARC GROUP – ESP DIVISION
1/ To protect operators against electrical risks to work in total confidence on the network
2/ To provide secured, easy to use and reliable products
3/ To improve maintenance and operations on the network
GENERAL PRESENTATION
■ THE NOVARC GROUP - ESP DIVISION
PRODUCTION COMMERCIALISATION
GENERAL PRESENTATION
■ THE NOVARC GROUP - ESP DIVISION
Key figures
GENERAL PRESENTATION
■ THE NOVARC GROUP - ESP DIVISION
Our know how
100% Products design and made in France
Compliance with the EN and IEC standard
More 60 years experience in electrical safety equipments
MAINTENANCE AND OPERATION ON THE LOW VOLTAGE NETWORK
UNDERGROUND OPERATIONS
OVERHEADLINE OPERATIONS
RANGES OF PRODUCTS
RANGES OF PRODUCTS
■ CLIMBING EQUIPMENTS
RANGES OF PRODUCTS
■ ANTI-FALL PROTECTIVE EQUIPMENTS
RANGES OF PRODUCTS
■ ARC FLASH PROTECTION
RANGES OF PRODUCTS
■ LOW VOLTAGE DETECTOR
TAG780D
Two probes designed for comfortable
handling with gloves
Slim probes
Test Bouton suitable for electrician’s gloves
Silicone double insulated lead
CAT IV 1000V CAT IV 1000V IP65IP65DIGITALDIGITAL
LV Detector TAG 780D
LEDs Digital display
Go / No Goindication
■ Functions of the LV detectorFunctions of the LV detector
Hazardous voltage light & sound indication : above 50V AC 120V DC ;
Redundant measurement batteries Circuit w/o Unipolar Phase indication on the 2
probes (NEUTRAL FAILURE detection) PHASE SEQUENCE (field rotation)
compatible with Gen Set
Indication of Voltage levels 120V 230V 400V 1000V
Voltage display from 5 V to 999 V (3 digits)
POLARITY indication on DC CONTINUITY test < 100 Ω AC or DC indication TEST BUTTON
LV Detector TAG 780D
Every function compatible with electrician gloves
Display Display accuracy: +/-2% + 1digit Display Resolution : 1V Standard : IEC 61243-3 = 2010 Batteries 2 x 1,5V LR03 (AAA)
■ Specifications of the LV detectorSpecifications of the LV detector
Field of Use Voltage range 5V - 1000 V AC ; 5V –
1500V DC Nominal Voltage indications : 120,
230, 400 et 1000V AC DC Operating current < 3.5 mA 1000V cat. IV Frequency range for AC: 15 Hz to 60
Hz Temperature : - 15°C + 45°C
LV Detector TAG 780D
■ Standard and EnvironmentStandard and Environment
LV DETECTOR TAG 780D
Low voltage detector with digital display TAG 780DTwo-pole Low-Voltage Detector Standard IEC 61243-3 (2009-11) Main purpose:
Proving Dead = Checking the absence of operating voltage before connecting earthing device. Technical Specific feature :
the device are equipped with a « low impedance » circuit to drain residual current and make the difference with operating voltage. (vs. Multimeters with ultra high impedance). 100% Availability to secure safety mission: NO Fuse but reversible variable resistors Redundant circuit for Hazardous voltage indication operating w/o battery.
LV Phase rotation Indicator DR 706
LV Phase rotation Indicator DR 706
Ergonomically shaped to fit comfortably in the palm
Replaceable leads with European colour codes and L1/L2/L3 marking (other markings or colours to order).Probes with HPC fuses : Ø 4 mm –IP2X
Heavy duty waterproof housingCan be used in all weathersProtection : IP65 housing and circuit totally sealed with compround
Unique bright LED displayChasing red LEDs for the counter-clockwise rotation.
■ Functions of the LV Phase rotation IndicatorFunctions of the LV Phase rotation Indicator
LV Phase rotation Indicator DR 706
PHASE ROTATION / SEQUENCE TESTER INDICATOR
■ Specification of the Phase rotation IndicatorSpecification of the Phase rotation Indicator
LV Phase rotation Indicator DR 706
Voltage range : 80V to 400 V AC AC frequency range : 50 Hz & 60 Hz Maximum rated voltage : 440 V three phase system Category of use : cat. IV (network) Class : N = - 10°C to + 55°C
LV Phase rotation Indicator DR 706
■ Standard and EnvironmentStandard and Environment
Category of use : cat. IV (network)
Probes with HPC fuses : Ø 4 mm –IP2X
Protection : IP65 housing and circuit totally sealed with campound
LV DEAD UNDERGROUND NETWORK
■ EARTHING and SHORT-CIRCUITING
LV Live Underground Cable Identifier FC5300
LV Live Cable Identifier FC5300
LV Live Cable Identifier FC5300
Heavy duty sealed case Instructions always visible to guide the user step by step
Reliable connectors : double-insultated, sheathed, sheathed conductors, in accordance with new standards
Directional probe allows certain identification of the cable
Clear Identification
Connection of the most universal identification signal and phase generator (modulator) possible on the customer’s network or in a connection bos
LV Live Cable Identifier FC5300
■ Functions of the LV Live Cable IdentifierFunctions of the LV Live Cable Identifier
Identification of Low Voltage live cables :- In order to make a live connection- Prior to de-energized operation
Didactic operating mode present on the modulator Secured identification : The device indicates that it has identified the
cable through a cross checking of frequencies and signal patterns. Signal identification is secure due to current drawing method and digital
signature : no signal on the adjacent cables or on MV cables Overhead and underground cables “Paper-lead”, “dry”, “double steel armouring” cables. Urban, suburban and rural areas
LV Live Cable Identifier FC5300
■ Specifications of the LV Live Cable IdentifierSpecifications of the LV Live Cable Identifier
FC5300E modulator : Nominal voltage 220 V rms to 400 V rms three
phase, bi phase or single phase Maximum rated voltage 440 V rms between inputs Network frequency 50 Hz or 60 Hz to be specified Number of channels 2 Duration of tapping per channel 0.256 s (per cycle) Pulse cycle 0.16 Hz Rms tapping current ~4 A/channel during impulse Peak current under 230 V or 400 V ~16 A peak
LV Live Cable Identifier FC5300
■ Specifications of the LV Live Cable IdentifierSpecifications of the LV Live Cable Identifier
Inputs protection : fast-acting HRC fuses in the housing and at the IP2X leads connecting points
Overvaltage Category : 1000 V – Cat.IV Operating temperature - 20°C to + 40°C Forced ventilation 2 + 2 fans Max. temperature protection by switching off the tapping : 90°C ±3� Approximate dimensions : 470 x 360 x 190 mm Approximate mass 9.85 kg
LV Live Cable Identifier FC5300
■ Specifications of the LV Live Cable IdentifierSpecifications of the LV Live Cable Identifier
FC5300D detector : Power suply battery 3.7 V (Lithium-ion) Autonomy over 1000 detections Display screen LCD 128 x 64 backlight Battery level check battery level indication Choice of functions by dedicated buttons Automatic standby and power cut-off Menus available in 6 languages External magnetic probe Analyser DSP/ARM + PIC
LV Live Cable Identifier FC5300
■ Specifications of the LV Live Cable IdentifierSpecifications of the LV Live Cable Identifier
Approximate dimensions 160 x 95 x 50 mm Approximate mass 0.35 kg (with battery) Battery charger USB type, mains and vehicle Protection shockproof rubber-type shell
FC5k3SD probe : Receiving sensor magnetic, differential 3 sensitivities according to the type of cable Protection by shockproof “rubber” positioning shoe
LV Live Cable Identifier FC5300
■ Standard and EnvironmentStandard and Environment
Compliant and qualified to EDF-Serect specification ST BT 840C (2000-11)
CE marking Compliant with European Directives : Relating to electromagnetic compatibility (EMC Directive)89/336/EEC, 92/31/EEC, 93/68/EEC et 92-587/RF, 95-283/RFstandard EN 55011 edition 2009 + A1/2010 Relating to safety of low-voltage equipment (LV Directive)73/23/EEC et 75-848/RFstandards IEC/EN 61010-1 ed. 3.0 (2010-06)
IEC/EN 61010-031 ed.1.1 (2008-06)
LV DEAD LINE NETWORK
■ EARTHING and SHORT-CIRCUITING
LV UNDERGROUND & OVERHEADLINE NETWORK
■ DETECTION AND EARTHING INSULATING STICKS
LV LIVE WORKING
■ INSULATED/INSULATING TOOLS 1000 V
RANGES OF PRODUCTS
■ CABLE PREPARATION TOOLS
LV LIVE WORKING
■ TEMPORARY INSULATION
RANGES OF PRODUCTS
■ SUBSTATION EQUIPEMENT/ RESCUE EQUIPMENT
OUR CLIENTS
■ THEY ARE TRUSTING US
END OF THE PRESENTATION
THANK YOU VERY MUCH FOR YOUR ATTENTION
WORK IN TOTAL CONFIDENCE ON YOUR POWER NETWORK
FOR UAE: [email protected]
Top Related