GSPublisherEngine 0.0.100.100
THIS DRAWING IS NOT TO BE SCALED. ONLY FIGURED DIMENSIONS E TO BE FOLLOWED.CONTRACTORS ARE TO CHECK ALL DIMENSIONS AND LEVELS BEFORE ANY WORK
COMMENCES AND TO REFER ANY APPARENT DISCREPANCY TO THE ARCHITECTS. THISDRAWING IS THE SOLE PROPERTY OF THE ARCHITECTS, AND MAY NOT BE COPIED OR
REPRODUCED WITHOUT THE OWNER'S WRITTEN CONSENT. ©
drawing description
project file
revisions
DATEBYREV DESCRIPTION
client details
project description
DATE: DRAWN BY
DRAWING No:PROJECT No:
SCALE
REV.
RENOVATIONS & ALTERATIONS151 of 10054 & 152 of 10054 OF DURBAN399 MAHATMA GHANDI ROADRATE NO. 376043
professional team
NATIONAL BRANDS LIMITEDENTYCE BEVERAGES
Reg. No.: 6628
HEALTH/ DRAINAGE NOTES
AIR TO BE UNIFORMILY DISTRIBUTED THROUGHOUT ALL HABITABLEAREA.
LIGHTING AND VENTILATION TO COMPLY WITH L.A & N.B.RREQUIREMENTS.ALL WASTE PIPES AND DRAINS TO BE ACCESSABLE ALONG THE ENTIRELENGHT.
INSPECTION EYE (I.E's) OT BE PROVIDED AT ALL BENDS AND JUNCTIONSIN THE DRAIN AND AT A MAXIMUM OF 23m LENGTHS ALONG STRAIGHTRUNS OF THE DRAIN.
ALL INSPECTION EYES TO HAVE MARKED COVERS AT GROUND LEVEL.
CLEANING EYES (C.E's) TO BE PROVIDED AT ALL BENDS AND JUNCTIONSOF WASTE PIPES.
ALL WASTES TO BE FITTED WITH 64mm RE-SEAL TRAPS.
ALL SOIL PIPES TO BE 110mmØ EXCEPT URINALS WHICH ARE TO BE75mmØ OR 50mmØ IN CASE OF WALL HUNG URINALS.
ANY WASTE WATER DISCHARGING OVER A GULLEY TO COMPLY WITHPART PP18.2 OF THE NBR's.
GENERAL NOTES
ALL DIMENTIONS AND LEVELS TO BE CHECKED ON SITE PRIOR TOANY WORK COMMENCING AND ARCHITECT TO BE NOTIFIED IMMEDIATELYOF ANY DISCREPTENCIES.
FIGURED DIMENTIONS ONLY TO BE TAKEN - DRAWINGS ARE NOT TOBE SCALED.
ALL REINFORCED CONCRETE WORK TO BE STRICTLY IN ACCORDANCEWITH STRUCTURAL ENGINEER'S DETAIL AND SPECIFICATION.
ANTGUARDS AND DAMPPROOF COURSE TO COMPLY WITH RELEVANTBY-LAWS AND N.B.R REQUIREMENTS.
ALL WALLS TO BE REINFORCED WITH TWO COURSES OF BRICKFORCE ATALL CILL AND WALL PLATE LEVELS.
ALL EXTERNAL FACEBRICK WALLS TO HAVE OUTER FACE OF INNER SKINOF BRICKWORK BAGGED AND PAINTED WITH BITUMEN.
ALL HOT WATER SERVICE PIPES SHALL BE CLAD WITH INSULATION WITHA MINIMUM R-VALUE OF 1,00.
ROOF ASSEMBLY SHALL ACHIEVE A MINIMUM TOTAL R-VALUE OF 2,7.
NOTE:
ALL SEWER & STORMWATER LAYOUTSTO ENGINEER'S DESIGN & DETAILS
SIZES OF WASTE/SOIL PIPES:-32mmØ - WHB38mmØ - SHOWER AND SINK50mmØ - COLDROOM CONDENSATE100mmØ - WC AND REFUSE FLOOR DRAIN
FOR ACCURATE DUCT SIZES REFER TO DETAIL DRAWING
ALL SOIL VENTILATION PIPES (S.V.P's) MUST BE TAKEN TO A MINIMUMHEIGHT OF 1.8m ABOVE THE NEAREST ADJACENT WINDOW HEAD.
WHERE A DRAIN PASSES UNDER A BUILDING IT MUST BE ENCASED IN150mm CONCRETE ALL ROUND AND MUST BE IN A STRAIGHT RUN UNDERTHE BUILDING WITH NO BENDS OR JUNCTIONS AND MUST HAVE I.E's ATEACH END AT A MINIMUM OF 600mm BEYOND THE BUILDING.
WHERE THE VERTICAL DROP FROM SOIL FITTINGS TO THE MAIN DRAINEXCEEDS 1,2m THESE FITTINGS ARE TO BE ANTI-SYPHON VENTED
ALL ACCESS PANELS TO BE 500x500mm LOCATED AT PIPE JUNCTION
EXTERNAL PANEL TO BE FIBRE CEMENT FINISHED TO MATCHSURROUNDING PLASTER/WALL FINISH.
External: Remove loose and peeling paint back to a firm byscraping, sanding or other suitable means and feather edges.Apply sodium hypocholrite solution (house hold bleach thinned 1part bleach to 2 part water) to all areas containing algae. Leavefor at least 1 hour. Scrub entire area with sugar soap solution toremove dirt, chalked material and any other contaminants, rinsethoroughly with fresh water and allow to dry (see below). Repaircracks and /or plaster defects as per 'Crack Repair/PlasterFinish' available from Plascon. All surfaces must be clean,sound and dry before painting. The moisture content of thecement plaster must be below 8% when measured on a Doserhygrometer BD2 scale(or equivalent). Colour in accordance withfinishing schedule.
1
External: New Masonry walls, inner skin of exterior face to bebagwashed plastered and painted. Colour in accordance withfinishing schedule.Internal: New Masonry walls, to be bagwashed plastered andpainted. Colour in accordance with finishing schedule.
3
New masonry retaining wall to eng. details. Bagwashedplastered and painted. Colour in accordance with finishingschedule.
4
WALLS
Internal: Remove loose bad flaking plaster. Re-plaster wall.Scrub entire area with surgar soap solution to remove dirt,chalked material and any other contaminants. Rinse thoroughlywith fresh water and allow to dry. All surfaces must be clean,sound and dry before painting. the moisture content of thecement plaster surfaces must be below 8% when measured ona Doser Hydgrometer BD2 scale (or equivelant). Colour inaccordance with finishing schedule.
2
WINDOWSNew epoxy powder coated aluminium Window Frames with 4mmtoughened safety glazing all to specialists specs. Colour inaccordance with glazing schedule.
5
Existing Steel: Remove loose and flaking paint back to firmedge by scraping, sanding, etc. Feather edges. Wash paintsurfaces with surgar soap solution to remove dirt and othercontaminants. Rinse thorougly with fresh water and allow drying.Remove rust completely back to bright metal by sanding andscraping, or by using rust remover following instructions on thecontainer. Where rust cannot be removed completly then rusistis to be applied: all loose rust must be removed by scraping,chipping, etc. Where it is not possible or practical to remove rustcompletely, such as in hidden areas and deep recesses, rusistRust Converter may be applied. Sand old enamel paint to aneven matt finish to remove chalked material and to provide akey. Surfaces must be clean, sound and dry before painting.Application: Spot prime bare areas with Zinc phospahate primer.First coat Professional all purpose undercoat. Second and thirdcoat Proffesional brilliant white gloss enamel. 16hr drying timebetween coats. Colour in accordance with finishing schedule.
6
DOORSNew solid laminated timber flush panel door, with hardwoodveneer on both sides and solid concealed edge strips to beprimed and painted with Plascon Woodcare Ultra VarnishProduct Code: X33 & X44 and Plascon White. All to specilaistsspecs.
7
CEILINGRemove existing suspended ceiling and insulation. Install newOWAcoustic®Premium Constellation 3 bio-degradable mineralwool ceiling tiles, (NRC 0,70) size 600x600x15mm thicknesswith square edge and white painted finish, laid on fire ratedOWAconstruct S3 exposed demountable T24 suspensionsystem including galvanised main tees, cross tees and allsuspended with galvanised hangers at centres not exceeding1200mm. Ceiling perimeter to be finished with pre-paintedshadowline 50/15G or standard wall trim. With new 175mmThick Pink aerolite ceiling insulation on ceiling tiles.
8
Remove existing suspended ceiling and insulation. 9mm VinylFaced Gypsum Ceiling Panels, face-covered with whiteembossed vinyl, size 1200 x 600mm, laid on fire ratedOWAconstruct® S3 exposed demountable Butt-cut T24suspension system including galvanised main tees, cross tees,etc., all suspended with galvanised hangers at centres notexceeding 1200mm, with ceiling perimeter finished withOWAconstruct® L-trim plugged at 200mm centres, and allinstalled to manufacturer's instructions. With new 175mm ThickPink aerolite ceiling insulation on ceiling tiles.
9
FLOORS
New Paving, formed of 60mm mulit-coloured interlocking blocks,laid to slight falls and levels as required, on and including 20mmsand bed, treated with weed killer and compacted with a platecompactor to eng. details, with fine sand spread over and sweptinto joints.
22
Remove existing Epoxy Floor. Torch off and remove excessadhesive. Repair any damaged to subfloor and uneven surfaces.Prepair floor with TAL screed-master laid to slight falls onconcrete floor, to take new abeScreed PU installed strictly inaccordance to manufacturers specs.
21
LOCKERS"Symolokka 3927401" epoxy coated baked enamel steel locker unit,size 300 x 450 x 1950mm high, with one door, shelf coat rail on250mm high legs to manufacturers specs.
ROOF
New COLORPLUS® AZ200 colour: Deep Ocean IBR roofsheeting to be layed with 75mm "Isover Factorylite" reinforcedfoil faced glasswool insulation, fixed over steel purlinsconcurrent with roof sheeting in strict accordance withmanufacturers specs.
13
Remove exist. roof structure. Construct new roof structurestrictly in accordance with manufacturers specs. Class A roofconstruction with COLORPLUS® AZ200 colour: Deep OceanIBR roof sheeting with an underlay of 375 micron polyethyleneplastic uPVC sheeting with 150mm lapped and sealed joints andnailed through underlay with stainless steel tie nails to andincluding 38 x 38mm sawn softwood battens at 345mm centreson gangnailed Grade 4 timber trusses at appropriate centresstrictly in accordance with manufacturers specs.
12
TIMBER & STEEL BENCHESSlatted seat ( 450mm wide 0, formed of 75 x 50mm angle roundedslats at 85mm centres, screwed from under to hollow section steelframes.
"ClearVU - Invisible Wall" marine fusion bond RAL 9005 - 700,1500mm high, in panels 3297mm long, including posts set insuitable concrete bases, all in accordane with manufacturersspecs.
14
FENCING
Remove loose plaster and bring back to stable sections. Applywire mesh to large areas. Small areas of less than 0.4 sqm maybe patched with non-shrink grout. Apply primer and 2 coats offinishing paint to match existing.
15
SLAB SOFFIT
Supply and fit “Beta” S/S/S Drywall partitions with boards fullheight to 2.700m fixed to concrete floor with 90mm skirtingchannel and suspended ceiling tees with 90mm Ceiling channel.Drywall Partition System comprising natural anodised aluminiumceiling channel, 65mm floor track and 64mm vertical studs at600mm centres, friction fitted, or riveted to ceiling channel andfloor tracks with similar additional vertical studs as necessary atcorners ends etc. and covered both sides with 12mm GypsumTapered Edge Wallboard screwed to studding with 25mm drywallscrews at maximum 230mm centres. Boards are to be buttjoined and tapered edges fitted with 50mm wide self-adhesive“Fibatape” and finished with jointing compound all in accordancewith the manufacturer’s instructions. Fit 76 x 1 ,6mm naturalanodised aluminium skirting to both sides of drywall.Intersections and abutments are measured separately anddescriptions shall be deemed to include any additional studs,corner beads, jointing compound, tape,etc. Strictly inaccordance to manufactueres specs.
16
PARTITIONS
DOOR: Extra over partition for 40mm hardwood flush panel door813 x 2032mm with hardwood edge strips hung to and including“Beta” natural anodised aluminium door frame with pre-fittedwool pile gaskets with one pair of 100mm natural anodisedaluminium sinkless hinges including 76mm Inox CylinderLockset and furniture, and additional studding as necessary.
17
Supply and fit “Beta” S/G/S Drywall partitions with boards to 1.050m high, glazed panes to door head height and boards aboveto ceiling height of 2.700m. Glazed panes to be framed all roundwith “Beta” aluminium glazing sections and beads, all pre-fittedwith woolpile gaskets. Glass to be 4mm clear float. Partitionsfixed to concrete floor with 90mm skirting channel andsuspended ceiling tees with 90mm Ceiling channel. DrywallPartition System comprising natural anodised aluminium ceilingchannel, 65mm floor track and 64mm vertical studs at 600mmcentres, friction fitted, or riveted to ceiling channel and floortracks with similar additional vertical studs as necessary atcorners ends etc. and covered both sides with 12mm GypsumTapered Edge Wallboard screwed to studding with 25mm drywallscrews at maximum 230mm centres. Boards are to be buttjoined and tapered edges fitted with 50mm wide self-adhesive“Fibatape” and finished with jointing compound all in accordancewith the manufacturer’s instructions. Fit 76 x 1 ,6mm naturalanodised aluminium skirting to both sides of drywall.Intersections and abutments are measured separately anddescriptions shall be deemed to include any additional studs,corner beads, jointing compound, tape,etc. Strictly inaccordance to manufactueres specs.
18
Supply and fit “Beta” G/G/G/ Drywall partitions with glazed panesfull height to 2.700m. Glazed panes to be framed all round with“Beta” Aluminium glazing sections and beads, all pre-fitted withwoolpile gaskets. Glass to be 6.5mm clear “Fadeban” laminatedsafety glass. Partitions fixed to concrete floor and suspendedceiling tees. Intersections and abutments are measuredseparately and descriptions shall be deemed to include anyadditional studs, corner beads, jointing compound, tape,etc.Strictly in accordance to manufactueres specs.
19
Remove existing Floor covering. Remove excess adhesive.Repair any damage to subfloor and uneven surfaces. Preparefloor with TAL screed-master to take new 600 x 600 CeramicTiles. Colour to be confirmed.
24
Remove existing Carpet Tiles. Torch off and remove excessadhesive. Repair any damage to subfloor and uneven surfaces.Preparer floor with TAL screed-master to receive new 6mmCarpet Tiles. Colour to be confirmed.
23
Hack up and remove existing screed to floors.. Remove alldebris/loose unsound screed from the area to be repaired. I the caseof a crack, the contractor is to determine if the crack within the exist.screed layer has been transferred to the concrete slab. The Engineeris to carry out an inspecton. Based on the inspection and Engineersinstructions the concrete slab is to be repaired strictly in accordanceto eng. details.
EXIST. SCREED TO FLOORS
Apply "Pro Struct 528 : Structural Concrete'' or other equallyapproved product into the pre-saturated surface. Coverage will beapproximatley 1.4m2 at 10mm thick per 25kg of ''Pro Struct 528'' orother equally approved product. Ensure complete substrate contactand maximum compaction. Cure the repairs by keeping them dampfor 24hrs after the initial set has taken place. ALL STRUCTURALAND BUILDING REPAIR WORK TO BE CARRIED OUT UNDERSTRICT SUPERVISION OF A STRUCTURAL ENGINEER.
MORTAR REPAIR
STEEL
I fuba T2 Partition System comprising 12mm thick Compact HPLwhite panels supported by overhead bracing with grade 304 stainlesssteel supporting feet, plugged and screwed to floor and fixed intoposition by means of grade 304 stainless steel wall fixing bracketsplugged and screwed to walls. Partition doors: 762 x 1762mm highdoors including standard ironmongery comprising indicator bolts, hatand coat hooks with buffers.
TOILET PARTITIONS
Powder coated Aluminium be 600 x 600, with a frame filled in withfixed horizontal V-shaped aluminium louvres. Colour in accordancewith window shedule. Manufactured in strict accordance tomanufacturers specs.
LOUVRE VENTS
Remove Exist. tiles. Torch off and remove excess adhesive.Repair any damage to subfloor and uneven surfaces. Preparefloor to take new GRano Screed.
20
New In-Situ Surface Bed to eng. details with DPM underlay.Floor to be prepared with TAL screed-master laid to slight fallson concrete floor, to take new abeScreed PU installed strictly inaccordance to manufacturers specs.
25
New RC roof slab to eng. details. Prepare slab with screed toslaight falls to FBO's. Edges to be waterproofed and counterflashed to manufacturers specs.
26
Remove existing ceiling. Supply and install 3,600m CAPCO FireRated T38/ 40G main tees at 1,200m centres in one directionand 1,200m CAPCO Fire Rated T38/ 4OG cross tees at 450mmcentres perpendicular to main tees. Main tees to be suspendedat 1,200m centres by means of 25 x 25 x O,8mm galvanizedmild steel angle hangers fixed to bulb of main tee with wafer-tekscrews and to slab with 6 x 30mm express nails and washers.Fit 9,0mm thick gypsum board to underside of grid system withtapered edge of board facing down with 25mm drywall screws at150mm centres. Apply 50mm wide self-adhesive glass fibre tapeto all joints and finish with CAPCO Jointing Compound.Apply 3-5mm thick coat of CAPCO Gypsum Skimming Plaster to entiresurface of ceiling.
10
Supply and fit SIGMA ceiling transition 20 satin white epoxy coatedaluminium shadowline trim between same level gypsum flushplastered ceiling and exposed tee suspended ceiling. Ceilingtransition to be suspended from R. C. slab at 1,200m centres bymeans of 25 x 25mm G.M.S angle fixed with 6 x 30mm express nailsto slab and wafer-tek screws to ceiling transition.
CEILING TRANSITION
OCCUPANCY D2
owners signature
architects signature
drawing status
COUNCIL SUBMISSION
E-04
E-06
1 200 1 024 125 1 200
1 23
550
0
810
3 18
03
990
165 450615
4 57
523
0
325 23
0
9 300110
900
110
1 12
0
New opening in ex.wall, lintel to eng. etails
Lintel to eng. details
swdp
swdp
FBO
FBO
FBO
Timber slatted gate
FBO
swdp
New masonry balustrade to siton RC upstand beam tostructural eng. details
New masonry balustrade tosit on RC upstand beam tostructural eng. details
Air inlet onside off wall
svp
30m FHR &2x4,5kg DCP FE
Air inlet onside off wall
Ø110mm svp Air inlet onside off wall
Air inlet onside off wall
Ø110mm svp
Access Hatch
Ø110 VentedDropper 3
Ø110 VentedDropper 4
Air inlet onside off wall
Hygiezoneventilation systemto specialists specs.
Hygiezoneventilation system tospecialists specs.
30m FHR &2x4,5kg DCP FEFEMALE ABLUTIONS
Ex. FFL 8.54
MALEABLUTIONS
Ex. FFL 8.54
59 LOCKERS
u
wc
ex. sh
whb
wc
wc
wc
wc
wc
wc
wc
uu
whb
whb
whb
whb
sh
sh
timbe
r & s
teel
ben
ch
timber & steel bench
whb
42 LOCKERS
sh
sh
sh
sh
sh
sh
sh
sh
whb
u
FD FD
Exi
stin
g pe
rimet
er o
f bui
ldin
g
W04
Wall to beDemolished
Wall to be Demolished
Lockers
Lockers
Lockers
Lock
ers
Lock
ers
Lock
ers
Lockers
Lockers
ex. wall
ex. wall
ex. wall
ex. wall
ex. w
all
ex. sh ex.sh
ex. shex.sh
ex.sh
ex. w
all
Exist.door
Exist. Stairs Up Ex. FFL 8.49
ex. w
all
ex. w
all
ex. w
all
ex. w
all
Ex. FFL 8.49
ssvp ss
vp
46kw HeatPump
46kw HeatPump
5000 litreStainless
Steel Tank
New. FFL 9.11 5000 litreStainless
Steel Tank
5000 litreStainless
Steel Tank
Heat pump and reticulation systemto wet services Eng. details
3
3
3
3
3
3
3
3
3
3 3
3
3
3
3
3
3
3
3
3
3
3
32
NewFBO
NewFBO
New SWDPNew SWDP
26
Ex. Wall
Exist. steel covered walkwayExist. steel covered walkway Exist. steel covered walkway
FD
timbe
r & s
teel
ben
ch
scre
ed to
fall
screed to fall
scre
ed to
fall
screed to fall
screed to fall
screed to fall
screed to fall
screed to fall
Exist Roof to be removedover Exist Room Below.
New RC slab to be addedto structural eng. details
New
mas
onry
bal
ustra
de to
sit
on R
Cup
stan
d be
am to
stru
ctur
al e
ng. d
etai
ls
3
3
3
3
3
3
3
3
3
46kw HeatPump
New stairs upTread 300mmRise 160mm
New. FFL 8.47
26
svp
FD
FD
re6
whb
whb
whb
re4
FD
re5
re7
whb
whb
7
7
30m FHR & 2x9kg DCP FE
ExistingFactory
ExistingFactory
BB
CC
E-0
7
165 2 155 125 1 035 125 2 081
4 35
598
011
077
0 230
6 21
53
455
110
900
110
1 13
5
8 07
511
055
5
5 521 230
5 521 3 779
1 00
016
51
078
110
1 02
511
01
038
110
1 07
5
12 7
55
900
125
900
125
900
125
900
11032
5 110
900
125
900
125
900
125
480
1 10
512
51
470
125
1 00
011
050
0
1 73
5
665 5 021
300 110 1 825 110410 1 935 5 686
5 71
0
230
580
230
2 95
0
230 2 605 230 8 470 230 3 180 2302 835 8 930 3 410
15 175
810
3 18
0
230
580
230
2 95
0
3 99
0
New masonry column extended fromexist. column below to structural eng.details.
New masonry column extendedfrom exist. column below tostructural eng. details.
swdp
Air inlet onside off wall
Ø110 VentedDropper 1
Ø110 VentedDropper 5
edge
of n
ew ro
of o
verh
ead
W01 W01
W01W01
W01
W01
W01
W01
W01
W01
W01
W01
W02
W02W02W02
W02
W04
W01
W01
W01
W01
W01
W01
W01
1
Exi
st. p
erim
eter
may
var
y on
site
Exist. perimeter mayvary on site
1
1
1
Exi
st. p
erim
eter
may
var
y on
site
W02
Exist. roof sheeting
Covered walk way to eng. details
Covered walk way to eng. details
Covered walk wayto eng. details
W01
Exist. RC Roof Slab
PROPOSED ABLUTIONS FIRST FLOOR PLAN1:50
JPD 1:50
3.102 F
OCTOBER 2013
D13.022
PROPOSED ABLUTIONS FIRST FLOOR PLAN
A A