[email protected] www.seraphim-energy.com
BEHIND THE ECLIPSEWe challenged ourselves to push the boundaries of PV technology and pioneer new innovations in solar module design. The design of the Eclipse module takes into consideration every element that defines a perfect solar module. The culmination of our efforts is a module that is superior in performance, reliability, safety, and value.
Eclipse Module
400W-415W
Eclipse SRP-E01A(-HV)Eclipse SRP-E01A(-HV)
SRP-DS-EN-2020 V1.0| © Copyright 2020 Seraphim
Mechanical Specifications
Temperature Characteristics
Packing Configuration
Pieces per Pallet
Pallets per Container
Pieces per Container
Container
22
594
External Dimensions
Weight
Solar Cells
Front Glass
Frame
Junction Box
Output Cables
Connector
Mechanical Load
1941 x 1066 x 40 mm
23.5 kg
PERC Mono crystalline
3.2 mm AR coating tempered glass, low iron
Anodized aluminium alloy
IP68
4.0 mm ,cable length: 1000 mm
MC4 Compatible
Front side 5400Pa/ Rear side 2400Pa
-0.36 %/°C
-0.28 %/°C
+0.05 %/°C
-40~+85 °C
45±2 °C
I-V Curve
27
2
1066±2
1941
±2
Grounding holes2×Ø4
A A
10±1
1941
±216
61±1
1161
±1
1066±2
40±1
posi
tive
( + )
nega
tive
( - )
Con
nect
or
1000
I
II
SE
RIA
L N
UM
BE
R
SE
RIA
L N
UM
BE
R
1016±2
SER
IAL
NU
MBE
R
Mounting holes
SER
IAL
NU
MBE
R
Junction Box
Label
I
9
14
R4.5
5:1
70 70
7070
II2:1
Section A-A10:1
40
35
The Eclipse module takes advantage of Seraphim’s innovative module technology, using traditional solar cells to increase efficiency and reliability while reducing BOS cost. The Eclipse module bridges the gap between functionality and design, providing an elegant solution to all your solar energy needs.
Significantly Reduced Hot-Spot Effect
10% Reduction in BOS and Installation Cost
Installation
+System BOS
15% Greater Return on Projects
Reliable Connection
Low Resistance
Warranty
linear power output warranty
Guarantee on productmaterial and workmanship10
YEARS25YEARS
+15%
More Benefits
Certifications
Insurances
Temperature after shading test (at 5hrs, in °C)Maximum Temp
Average Temp
Minimum Temp
47.3°C
23.9°C
15.6°C
Improved Reliability and Durability
Better performance under shade
Beautifully designed
5400Pa Mechanical Load
1941 x 1066 x 40 mm
Electrical Characteristics
Maximum Power (Pmp)
Open Circuit Voltage (Voc)
Short Circuit Current (Isc)
Maximum Power Voltage (Vmp)
Maximum Power Current (Imp)
Module Efficiency at STC(ηm)
Power Tolerance
Maximum System Voltage
Maximum Series Fuse Rating
STC
400
45.10
11.34
37.20
10.76
NOCT
296
41.70
9.17
34.30
8.63
STC
405
45.30
11.42
37.40
10.83
NOCT
300
41.90
9.23
34.50
8.70
19.33 19.57
SRP-415-E01ASRP-415-E01A-HV
SRP-400-E01ASRP-400-E01A-HV
SRP-405-E01ASRP-405-E01A-HV
SRP-410-E01ASRP-410-E01A-HV
STC
410
45.50
11.51
37.60
10.91
NOCT
304
42.10
9.29
34.70
8.77
19.82
(0,+4.99)
1000 VDC / 1500 VDC
20A
0 10 20 30 40 50Voltage [V]
0
2
4
6
8
10
12
14
Cur
rent
[A]
Incident Irrad. = 1000 W/m²
Cells temp. = 25 °C
Incident Irrad. = 800 W/m²
Incident Irrad. = 600 W/m²
Incident Irrad. = 400 W/m²
Incident Irrad. = 200 W/m²
0 10 20 30 40 50Voltage [V]
0
2
4
6
8
10
12
Cur
rent
[A]
Incident Irrad. = 1000 W/m²Cells temp. = 10 °CCells temp. = 25 °CCells temp. = 40 °CCells temp. = 55 °CCells temp. = 70 °C
40’HQ
STC: lrradiance 1000 W/m2 module temperature 25°C AM=1.5,Power measurement tolerance: +/-3%;NOCT: lrradiance 800 W/m2 ambient temperature 20°C wind speed :1m/s Power measurement tolerance: +/-3%
SRP-XXX-E01A-HV: Maximum System Voltage1500 VDCSRP-XXX-E01A: Maximum System Voltage1000 VDC
100%
97.5% 97.5%95.1%
92.1%
89.1%
86.1%
83.1%
90%
80%
0 5 10 15 20 25
Addtional Value from Linear Warranty
Years
STC
415
45.70
11.58
37.80
10.98
NOCT
308
42.30
9.35
34.90
8.83
20.06