Eaton® Quick Connect® Air Brake Installation Guide
2 EATON Quick Connect Installation Guide E-BRQC-MR001-E July 2013 3EATON Quick Connect Installation Guide E-BRQC-MR001-E July 2013
Assembly Procedures
Step 1: Using a tube cutter, make a square cut edge (maximum 15˚ cutting angle allowed).
Note: Dull knives, side-cutters, or other cutting tools may NOT ensure a good, clean cut. Burrs, oval tubing, and contamination can damage seals and other system components.
Tube Insertion
Gentle Tug
90˚15˚ max.
ColletTube Support
O-Ring Body
Step 5: Allow the tube ample room for a gradual bend. Note: Severe bends can collapse tubing, resulting in leaks, line blockage, or flow restriction.
Step 2: Insert tubing straight into fitting until a solid stop is felt. The tubing grip and seal (on the O-ring) is now accomplished.
Step 3: Gently tug on tubing to ensure tubing is secure.
Parts Reference
Step 4: Install threaded end of fitting hand tight and make final adjustment with wrench on hex or flats of fitting body. Note: Never use a wrench near the tubing entry or collet head of fitting.
Disassembly Procedures
Step 1: Check to be sure there is no air pressure.
Step 2: Depress collet head using fingers or Weatherhead® tube-release toolto release grip on tubing.
Step 3: With the collet depressed, pull the tubing from the fitting.
Tube Release Tool
Keep Collet Depressed
Remove Tube
Keep Collet Depressed
Remove Tube
Eaton 14615 Lone Oak RoadEden Prairie, MN 55344USATel: 952 937-9800Fax: 952 974-7722www.hydraulics.eaton.com
EatonHydraulics Business EuropeRoute de la Longeraie 71110 MorgesSwitzerlandTel: +41 (0) 21 881 4600Fax: +41 (0) 21 881 4601www.eaton.com/hydraulics
EatonHydraulics Business Asia PacificEaton BuildingNo. 7 Lane 280 Linhong Rd.Changing DistrictShanghai 200335ChinaTel: (+86 21) 5200 0099Fax: (+86 21) 2230 7240
© 2013 Eaton All Rights Reserved Printed in USA Document No. E-BRQC-MR001-EJuly 2013