Duct numbering for EE-
Wolfgang Funk - CERN CMS23/09/2003
06.B
06.A07.B
07.A
08.B
08.A09.B
09.A
10.B
10.A
11.B
11.A
12.B 12.A
13.B13.A
14.B14.A
1
Wolfgang Funk - CERN CMS23/09/2003
Duct 05.A
Duct 05.B
LV 6*7.4 (259)HV 1*15.3 (184)OF 2*4.3X2 (18)signal 2*9 (128)
LV 6*7.4 (259)HV 1*15.3 (184)OF 2*4.3X2 (18)signal 2*9 (128)
Bret
OF 15*4.3X2 (129)HV 37*3 (262)Sniff 1*6 (29)
P F
14/23
Pret
LV 10*12.2 (1169)CO 1*14 con (154)Signal 2*10 (158)
CO 1*14 is (314mm**2)CO 1*14 con (154)
N2 1*8 (51)
snN2
Sum: (2070)
Sum: (1528)
Similar to Duct 03.B
Similar to Duct 03.A
View towards I.P. for EE+
View from I.P. for EE-
Duct 06.B
Duct 06.A
2
Wolfgang Funk - CERN CMS23/09/2003
Duct 04.A
Duct 04.B
LV 6*7.4 (259)HV 1*15.3 (184)OF 4*4.3X2 (35) signal 2*9 (128)
LV 12*7.4 (518)HV 2*15.3 (368) signal 4*9 (256)
P FP ret
HV 37*3 (262)CO 1*14 is (314)
OF 15*4.3X2 (129)
LV 10*12.2 (1169mm**2)CO 1*14 con (154)
Signal 1*10 (79)
P F Sum: (1847)
Sum: (2008)
Similar to Duct 02.A
Similar to Duct 02.B
Duct 07.B
Duct 07.A
3
Wolfgang Funk - CERN CMS23/09/2003
Duct 03.A
Duct 03.B
LV 6*7.4 (259)HV 1*15.3 (184)OF 4*4.3X2 (35)signal 2*9 (128)
LV 6*7.4 (259)HV 1*15.3 (184)OF 2*4.3X2 (18)Signal 2*9 (128)
OF 15*4.3X2 (129)HV 37*3 (262)
LV 10*12.2 (1169)CO 1*14 con (154)Signal 2*10 (158)
CO 4*10 is (804mm**2)CO 1*14 is (314)CO 1*12 is (255)CO 1*14 con (154)
OESR
P FP ret
BF BF BF BF OESF
FES F
Sum: (2070)
Sum: (2532)
Similar to Duct 05.B
Similar to Duct 05.A
Duct 08.B
Duct 08.A
4
Wolfgang Funk - CERN CMS23/09/2003
Duct 02.A
Duct 02.B
LV 6*7.4 (259)HV 1*15.3 (184)OF 2*4.3X2 (18)signal 2*9 (128)
LV 12*7.4 (518)HV 2*15.3 (368)OF 3*4.3X2 (27)signal 4*9 (256)
P FP ret
LV 10*12.2 (1169mm**2)CO 1*14 con (154)
Signal 1*10 (79)
CO 2*14 is (628)Laser 1*10 (79)
OF 15*4.3X2 (129)Co 1*14 (154)
P F
MEM 12*2.2 (46)MEM 2*1.5X2 (6)
HV 37*3 (262)
Note: additional cables between MEM and balconies: LV 4*5 (88), Ving 1*5 (22), OF 2*4.3X2 (128) MEM cables (MEM 12*2.2 (46) and MEM 2*1.5X2 (6) are only between MEM and Dees
Sum: (2473)
Sum: (2659)
Sum: (2153)
Similar to Duct 04.B
Similar to Duct 04.A
DCS 1*11 (95)DCS 1*7.2 (41)DCS 1*5.8 (26)
Duct 09.B
Duct 09.A
5
P F retB ret
Wolfgang Funk - CERN CMS23/09/2003
Duct 18.B
LV 6*7.4 (259)HV 1*15.3 (184)OF 2*4.3X2 (18)signal 2*9 (128)
P FP ret
LV 10*12.2 (1169mm**2)CO 1*14 con (154)
Signal 1*10 (79)
Sum: (2153)
Similar to Duct 16.B
Duct 11.A
Duct 18.A
CO 2*14 is (628)Co 1*14 (154)
P F
HV 37*3 (262)OF 15*4.3X2 (129)
Sum: (2351)
Similar to Duct 16.A
Duct 11.B
8
P F
LV 12*7.4 (518)HV 2*15.3 (368)OF 4*4.3X2 (36)signal 4*9 (256)
DCS 1*11 (95)DCS 1*7.2 (41)DCS 1*5.8 (26)
retB ret
Wolfgang Funk - CERN CMS23/09/2003
Duct 17.A
LV 6*7.4 (259)HV 1*15.3 (184)OF 2*4.3X2 (18)Signal 2*9 (128)
LV 10*12.2 (1169)CO 1*14 con (154)Signal 2*10 (158)
P FP ret Sum: (2070)
Similar to Duct 15.A
Duct 12.B
Duct 17.B
LV 6*7.4 (259)HV 1*15.3 (184)OF 4*4.3X2 (35)signal 2*9 (128)
CO 4*10 is (804mm**2)CO 1*14 is (314)CO 1*12 con (113)CO 1*14 con (154)
OESRBF BF BF BF OES
FSum: (2382)
Similar to Duct 15.B
Duct 12.A
FES R
9
OF 15*4.3X2 (129)HV 37*3 (262)
Wolfgang Funk - CERN CMS23/09/2003
Duct 16.A
LV 12*7.4 (518)HV 2*15.3 (368) signal 4*9 (256)
P F Sum: (1847)
Similar to Duct 18.A
Duct 13.B
Duct 16.B
LV 6*7.4 (259)HV 1*15.3 (184)OF 4*4.3X2 (35) signal 2*9 (128)
P FP ret
LV 10*12.2 (1169mm**2)CO 1*14 con (154)
Signal 1*10 (79)
Sum: (2008)
Similar to Duct 18.B
Duct 13.A
10
HV 37*3 (262)CO 1*14 is (314)
OF 15*4.3X2 (129)
Wolfgang Funk - CERN CMS23/09/2003
Duct 15.A
LV 6*7.4 (259)OF 2*4.3X2 (18)signal 2*9 (128)
14/23
Pret
LV 10*12.2 (1169)CO 1*14 con (154)Signal 2*10 (158)
Sum: (1886)
Similar to Duct 17.A
Duct 14.B
Duct 15.B
LV 6*7.4 (259)HV 1*15.3 (184)OF 1*4.3X2 (18)signal 2*9 (128)
Bret
HV 37*3 (262)OF 15*4.3X2 (129)
Sniff 1*6 (29)
P F
CO 1*14 is (314mm**2)CO 1*14 con (154)
N2 1*8 (51)
snN2 Sum: (1641)
Similar to Duct 17.B
Duct 14.A
N2/sniff 1*12 (113)
N2
Note: ES N2 pipe is input on one Dee and output on other Dee (same diameter)
11
History
Wolfgang Funk - CERN CMS23/09/2003 12
1. Move ES services out of 10B-/10A- into 9A-/11B- (no space in ducts with ES pipes).2. Move PF from 7A- to 9A- and from 13B- to 11B- to avoid crossing of cooling pipe over
ring flange bean.3. Move half of OF from 6B-/8B-/13B-/11B- to 7A-/9A-/14A-/12A- to have less crossings.4. Move half of HV from 7A-/9A-/14A-/12A- to 6B-/8B-/13B-/11B- to have less crossings.5. Change of DCS scheme: no DCS cable anymore in 7B-/13A-, but 3 DCS cables in
9B-/11A-, no overall cross section increase.
New version 14/7/03 to avoid crossing of services at EE patch panel area according to Justin’s proposal of patch panel design of spring ’03:
New version 6/8/03 to increase LV cable sets to 20/Quadrant (before 18/Quadrant) because of new “EE-mechatronics’’ design of Tony:
1. 2 more LV EE cables each in ducts 7B-,9B-,11A-,13A- .
New version 11/8/03 to increase space in ducts for ES cooling pipes.
1. Move EE backplate return pipes from 10B-/10A- into 9A-/11B- .
Top Related