®DSEULTRA®
STARTINGWITHQUALITY. SPECIFICATION
The DSE4410 is an Auto StartControl Module and the DSE4420 isan Auto Mains (Utility) FailureControl Module for single gen-setapplications. Both modules havebeen designed to work withelectronic and non electronicengines providing advanced enginemonitoring and protection features.The modules are available inmagnetic pick-up and Canbusversions.
The modules include a back-litLCD display which clearly show thestatus of the engine at all times.They monitor frequency, voltage,current, oil pressure, coolanttemperature and fuel level. Themodules have also been designedto display the warning andshutdown status of the engine.
Both modules include six digitalinputs and six outputs. Fouroutputs are configurable on themagnetic pick-up version and sixare configurable on the Canbusversion. The modules can eitherbe programmed using the frontpanel or by using the DSEConfiguration Suite PC software.
FEATURES• PC and front panel configurableCAN and magnetic pick-up versions• Six digital inputs• Six outputs (all six configurable onCANbus version, four configurableon magnetic pick-up version)
• Automatic mains (utility) supplymonitoring (DSE4420 only)
• Event log• 50/60 Hz calibration setting• Configurable timers• Automatic shutdown or warningwhen fault conditions are detected
• Manual and remote start• Engine pre-heat• Protected Solid State Outputs(PSS)
• Advanced metering capability• Front panel mounting• Front panel programming• Engine hours counter• LED indicators• Back-lit LCD display
BENEFITS• Transfers between mains (utility)and generator power(DSE4420 only)
• Hours counter provides accurateinformation for monitoring andmaintenance periods
• User-friendly set-up and buttonlayout. Multiple engine parametersare monitored simultaneously
• Module can be configured to suitindividual applications. Wide rangeof engines can be specifiedIP65/NEMA 12 rating offersadvanced resistance to wateringress
• License free PC software
OPERATIONThe module is operated using thefront STOP/RESET, MANUAL, AUTOand START push buttons.
Two additional push buttons next tothe LCD screen are provided toscroll through the modules’ meteringdisplays and to access the event log.
OVERSPEED PROTECTIONThe engine over speed trip settingcan be calibrated for 50Hz or 60Hznominal operation During enginecranking and for a user configurabletime after the engine starts running,all alarm conditions are suspendedto allow the engine to reach itsoptimum running speed.
CONFIGURATIONThe modules can be configuredusing the front panel or by remotePC using a USB connection leadand the DSE Configuration Suite PCsoftware.
ELECTRONIC ENGINECOMPATIBILITY• CAT• Cummins• Deutz• John Deere• MTU• Perkins• Scania• Volvo• Generic• Plus additional manufacturers
DC SUPPLY8V to 35V Continuous
CRANKING DROPOUTSAble to survive 0V for 50mS, providing supplywas at least 10V before dropout and supplyrecovers to 5V. This is achieved without theneed for internal batteries. LEDs and backlightwill not be maintained during cranking.
MAXIMUM OPERATING CURRENTTBC
MAXIMUM STANDBY CURRENTTBC
GENERATOR INPUT RANGE15V to 333V AC (L-N) absolute maximum50Hz - 60Hz (min 15V AC)
CHARGE FAIL/EXCITATION RANGE0V to 35V
VOLTAGE RANGE0.5V RMS minimum
FREQUENCY RANGE10,000 Hz (max)
15V to 333V AC (L-N) absolute maximum25V to 576V AC (L-L) absolute maximum50Hz - 60Hz (min 15V AC)
OVERALL180mm x 116mm x 42mm7.1” x 4.6” x 1.7”
PANEL CUT-OUT154mm x 98mm6” x 3.9”
MAXIMUM PANEL THICKNESS8mm (0.3”)
DSE4410 & DSE4420AUTO START & AUTO MAINS (UTILITY) FAILURE CONTROL MODULES
DC SUPPLY
MAGNETIC PICKUP
OUTPUTS
DIMENSIONS
MAINS (UTILITY) SENSING INPUT RANGE(DSE4420 ONLY)
OUTPUT A (FUEL)2 Amp DC at supply voltage
OUTPUT B (START)2 Amp DC at supply voltage
AUXILIARY OUTPUTS C,D2 Amp DC at supply voltage
BATTERY
-VE
+V
E SE
ND
ER
CO
MM
ON
FUE
LS
EN
DE
R
6 INPUTSPLANT +VEPLANT +VE
4 FET OUTPUTSENGINE ECU
H L
BATTERY NEGATIVE MUST BE GROUNDED
TERMINALS SUITABLE FOR 22-16 AWG (0.6mm - 1.3mm )FIELD WIRING
TIGHTENING TORQUE = 0.8Nm (7lb-in)
NOTE 1. THESE GROUND CONNECTIONS MUST BE ON THE EN-GINE BLOCK, AND MUST BE TO THE SENDER BODIES.
NOTE 3. MAINS BREAKER CLOSED OUTPUT SHOULD BECONFIGURED FOR DE-ENERGISE CLOSE MAINS, AND USE THENORMALLY CLOSED CONTACTS OF MBCR.
†NOTE 2. 120 R TERMINATING RESISTORMAY BE REQUIRED EXTERNALLYSEE ENGINE MANUFACTURERS LITERATURE
†
NOTE 1
15 16 12 13 14 17 18 19 20
1 32 4 5 10 11 21 22 23 24 25 26 6 7 8 9 14 12 13
U NL1
GEN VOLTS
+ -MPU
RE
CO
MM
EN
DE
DT
HA
TE
ME
RG
EN
CY
ST
OP
BR
EA
KS
TH
EFU
EL
AN
DC
RA
NK
OU
TP
UT
S
FUE
L
INP
UT
AC
ON
FIG
UR
ED
FOR
EM
ST
OP
US
ER
CO
NFI
GU
RA
BLE
-VE
INP
UT
B
US
ER
CO
NFI
GU
RA
BLE
-VE
INP
UT
C
US
ER
CO
NFI
GU
RA
BLE
-VE
INP
UT
D
US
ER
CO
NFI
GU
RA
BLE
-VE
INP
UT
E
US
ER
CO
NFI
GU
RA
BLE
-VE
INP
UT
F
US
ER
CO
NFI
GU
RA
BLE
OU
TP
UT
CG
EN
BR
EA
KE
RC
LOS
E
US
ER
CO
NFI
GU
RA
BLE
OU
TP
UT
DM
AIN
SB
RE
AK
ER
CLO
SE
US
ER
CO
NFI
GU
RA
BLE
+V
EO
UT
PU
TE
US
ER
CO
NFI
GU
RA
BLE
+V
EO
UT
PU
TF
MIN
2A
MP
MA
X20
AM
PA
NT
I-S
UR
GE
FUS
EB
AT
TE
RY
FUEL
WL
CRANK
GBCR
CHARGEALT
2A
MP
FUS
ES
2A
MP
FUS
ES
AP
PR
OP
RIA
TE
FUS
E
MPU
MAG PICK UP VERSION ONLY
TO LOAD
L3
N
L2
L1
L3
N
L2
L1
FROMMAINS(UTILITY)
FROMGENERATOR
FUE
LO
/PA
CR
AN
KO
/PB
PROGRAMMING PORT
USB
CON 1 CON 2
GBCR
DSE4420 ONLY
MODULE 4410/4420
MBCR
*
AP
PR
OP
RIA
TE
FUS
E
DO NOTCONNECT
THESCREEN
TO ENGINE
CONNECT THESCREEN TO
ENGINE ONLY
ELECTRONIC ENGINE VERSION ONLY
*
*
MBCR
®
RELATED MATERIALSTITLE PART NO’SDSE4410 Manual 057-092DSE4420 Manual 057-093DSE Configuration Suite PC Software Manual 057-101DSE4410 Installation Instructions 053-056DSE4420 Installation Instructions 053-057
DEEP SEA ELECTRONICS INC3230 Williams AvenueRockfordIL 61101-2668 USA
TELEPHONE+1 (815) 316 8706
FACSIMILE+1 (815) 316 8708
WEBSITEwww.deepseausa.com
DEEP SEA ELECTRONICS PLCHighfield HouseHunmanby Industrial EstateHunmanby, North YorkshireYO14 0PH England
TELEPHONE+44 (0)1723 890099
FACSIMILE+44 (0)1723 893303
WEBSITEwww.deepseaplc.com
Registered in England & Wales No.01319649 VAT No.316923457
DEEP SEA ELECTRONICS maintains a policy of continuous development and reserves the right tochange the details shown on this data sheet without prior notice. The contents are intended for guidance only.
055-068/01/16 (2)
This data sheet is printed on 9lives 55 Silk, which is produced with 55% recycled fibrefrom both pre and post-consumer sources, together with 45% virgin ECF fibre.
DSE4410 & DSE4420
BS EN 61000-6-2EMC Generic Emission Standard for theIndustrial EnvironmentBS EN 61000-6-4EMC Generic Emission Standard for theIndustrial Environment
ENVIRONMENTAL
TESTING STANDARDS
INSTRUMENTATION AND ALARMS
ELECTRICAL SAFETYBS EN 60950Safety of Information Technology Equipment,including Electrical Business Equipment
TEMPERATURE (OPERATING)BS EN 60068-2-2Test Ab to +70oC 60067-2-2 HotTest Ab to -30oC 60068-2-1 Cold
VIBRATIONBS EN 60068-2-6Ten sweeps in each of three major axes5Hz to 8Hz @ +/-7.5mm, 8Hz to 500Hz @ 2gn
HUMIDITYBS 2011 part 2.1 60068-2-30Test Cb Ob Cyclic93% RH @ 40oC for 48 hours
SHOCKBS EN 60068-2-27Three shocks in each of three major axes15gn in 11mS
ELECTRICAL SAFETY/ELECTROMAGNETIC COMPATIBILITY
TESTING STANDARDS
The DSE4410 and DSE4420 both providecomprehensive metering and alarm indications:
Generator frequencyUnder/over speedGenerator volts (L-L, L-N)Engine oil pressureEngine coolant temperatureFuel level (warning or shutdown)Hours run counterBattery voltsFail to start/stopEmergency stopFailed to reach loading voltage/frequencyCharge failLow DC voltageCAN diagnosticsMains volts 3 phase (DSE4420 only)AMF indications (DSE4420 only)
Top Related