ProposedCapacity Expansion
in Existing Emulsion PlantLocated at Plot No.L-7, SIPCOT Industrial Park(Phase-II), Mambakkam Post, Sriperumbudur,
Kanchipuram District,Tamil Nadu.
August -2017
Prepared By
Dow Chemical International Private Limited
Application for Terms of Reference
Form I &
Pre Feasibility Report
Schedule : 5(f) – Category : B
PREFEASIBILITY REPORT
1 ABC/DOW/PFR/VER2.0
1.0 INTRODUCTION
1.1 IDENTIFICATION OF PROJECT
The project proponent M/s. Dow Chemical International Private Limited, Sriperumbudur,
Chennai, is engaged in the production of Emulsion. Their existing production line includes 1)
Water Based Latex Polymer and 2) Latex Polymer Cake. The unit was established prior to EIA
Notification 2006, after obtaining Consent to Establish (Annexure - I) in August 2006. The
company was established by Rohm and Haas India Pvt. Ltd. and later merged with Dow
Chemical International Private Limited, the court order regarding merger is enclosed as
(Annexure-II).
The proponent has proposed to increase the production capacity of Water Based Latex Polymer
& Latex Polymer Cake at their factory located at SIPCOT Industrial Park (Phase– II),
Sriperumbudur. This proposal has been submitted for obtaining Environmental Clearance for
increasing the production capacity of Water Based Latex Polymer & Latex Polymer Cake.
1.2 IDENTIFICATION OF PROJECT PROPONENT
M/s. Dow Chemical International Private Limited is a fully owned subsidiary of The Dow
Chemical Company, USA and The Dow Chemical Company, commonly referred to as Dow, is
an American multinational chemical corporation headquartered in Midland, Michigan, United
States.
1.3 BRIEF DESCRIPTION OF NATURE OF THE PROJECT
The unit currently manufactures two products namely
1) Water Based Latex Polymer - 40000 MT/Year
2) Latex Polymer Cake – 407 MT/Year
The proponent has planned to increase the total quantity of products manufactured at the factory
to the following quantities
1) Water Based Latex Polymer - 70000 MT/Year
2) Latex Polymer Cake – 1462 MT/year
PREFEASIBILITY REPORT
2 ABC/DOW/PFR/VER2.0
The proposed expansion will fall under Schedule 5(f) of the EIA Notification - 2006 and
Amendments thereon. As the project site is located inside a notified industrial estate this project
falls under ‘B’ category and requires clearance from SEIAA-Tamil Nadu.
1.4 NEED FOR THE PROJECT AND IMPORTANCE TO THE NATION
DCIPL Chennai plant caters to the Emulsions (which are primarily used for water based paints)
requirements of Southern, Central and Eastern Regions of India apart from south Asian countries
and the Middle East. Export earnings of over 25 crores /year in foreign exchange are achieved
due to the operation of this plant. In order to meet the increase in demand, it is very much
essential to go for the expansion activities.
2.0 SITE ANALYSIS
2.1 LOCATION
Dow Chemical International Private Limited is located at Plot No.L-7, SIPCOT Industrial Park
(Phase– II), Ponthur A B C Village, Sriperumbudur Taluk, Kancheepuram District, Tamil Nadu.
The satellite Imagery of the site is shown Figure 2.1. The location of the project site is
represented in Figure 2.2.
Figure 2.1 Satellite image of project site
PREFEASIBILITY REPORT
3 ABC/DOW/PFR/VER2.0
Figure 2.2 Location map of project site
PREFEASIBILITY REPORT
4 ABC/DOW/PFR/VER2.0
2.2 CONNECTIVITY
The site is well connected by the Bangalore and Chennai National Highway (NH48) at a distance
of 1.2 km. This unit is located in the Southern direction of this road. The raw material & product
is conveniently transported by this road.
Figure 2.3 Connectivity map of project site
2.3 LANDUSE CLASSIFICATION & LANDUSE BREAKUP
Tamil Nadu Government has recognized the location of this unit as “SIPCOT Industrial Area”
and encouraging entrepreneurs to come forward for setting up industries. The area is dominated
by large scale industries and other medium scale industries.
The total plot area of the facility is 61,700 sq.m. The land use breakup of the project site is given
in Table 2.1. The topo map of the project site and its surrounding area covering 10 km radius are
given in Figures 2.4 and Environmental settings are presented in Table 2.2.
PREFEASIBILITY REPORT
5 ABC/DOW/PFR/VER2.0
Figure 2.4 Topo map (10km around project site)
PREFEASIBILITY REPORT
6 ABC/DOW/PFR/VER2.0
Table 2.1 Land Use Break up of Project Site
S. No Land Use Breakup Details Area (Sq.m.) 1. Process Building Area 515 2. Non-Process Building Area 3293 3. Storage Area 3600 4. Parking Area 600 5. Driveway & Pathway Area 5500
6. Future Expansion Area 1000
7. Green Belt Development Area 21500 8. Open Area ( Including lawns) 25692
Total Area 61700
Table 2.2 Environmental Settings of Project Site
S. NO. PARTICULARS DETAILS 1 Site Latitude 12°55'32.12"N 2 Site Longitude 79°54'40.24" E 3 Site Elevation 60 m
4 Nearest highway Bangalore and Chennai National Highway (NH48) – 1.2 km (N)
5 Nearest railway station Tambaram Railway Station- 22 Km [E] 6 Nearest airport Chennai International Airport - 28 km (ENE) 7 Nearest town/ city Sriperumbudur Town – 5.5 KM [NE] 8 Topography Plain 9 Archaeologically important places Nil within 10 km radius
10 National parks/ Wildlife Sanctuaries
Nil within 10 km radius
11 Reservoir Sriperumbudur Lake - 4.3 KM ( NE) Thenneri Lake - 7.1 KM (SE)
12 Reserved/ Protected Forests Vattambakkam R.F. - 8.5 km (S) 13 Seismicity Zone III 14 Defence Installations Nil within 10 km radius 15 Nearest Port Chennai Port – 45 km (NE)
2.4 SITE SUITABILITY / ALTERNATE SITES CONSIDERED
The proposed expansion will take place within the existing facility leased from SIPCOT. This
site has the following advantages:
• As the factory is currently in operation, all infrastructural facilities are already in place.
• It is an only expansion of existing operation.
Hence, no alternative sites were considered.
PREFEASIBILITY REPORT
7 ABC/DOW/PFR/VER2.0
3.0 PROJECT DESCRIPTION
3.1 MAGNITUDE OF OPERATION
Production capacities of the products, existing and after expansion have been detailed in
Table 3.1.
Table 3.1 Production Capacity before and after expansion
Water Based Latex polymer
(MT/Year)
Latex Polymer Cake
(MT/Year)
Existing 40000 407
After expansion 70000 1462
3.2 RAW MATERIALS REQUIRED FOR PRODUCTION
Table 3.2 List of Raw Materials
Raw-Material
Name
Raw-Material
Quantity(MT/Day)
[Existing - 40000T/Year]
Raw-Material
Quantity(MT/Day) [After
Expansion - 70000T/Year]
Mode of
Transport
Butyl Acrylate 12 21 Ship
Methyl
Methacrylate 5.5 9.625 Ship
Ethyl Acrylate 1.7 2.975 Road
Vinyl Acetate 3 5.25 Road
Styrene 12 21 Road
2 Ethyl hexyl
Acrylate 5 8.75 Ship
Acrylonitrile 1 1.75 Road
Additives 2 3.5 Ship/Road
Water 77 134.75 In House
PREFEASIBILITY REPORT
8 ABC/DOW/PFR/VER2.0
3.3 PROCESS DESCRIPTION
This plant produces a wide range of acrylic, vinyl acetate, vinyl acrylic and other water based
latex polymers. Bulk monomers stored in storage tanks and other monomers from
drums/totes are pumped in measured quantities to Emulsion feed tank and water and
additives are added to disperse the monomer to form monomer emulsion using gentle
agitation. The reactor is cleaned and hot RO water is added to preset quantity along with
other additives. The preset quantity of monomer emulsion and additives from feed tank
(catalyst) are added to the reactor in a controlled manner so as to maintain the temperature
80-95.C by means of external cooling water circulation in the reactor. The polymerization of
monomers to desired product is completed with the final reactor level. The product emulsion
is transferred to drain the tank and final cooling and other additives addition effected to adjust
desired parameters in the product like pH, viscosity etc. The product after quality testing is
transferred to product storage tanks. The product from the storage tank is also packed in
drums/totes as per the requirement and mainly transported in tankers to customers.
The reaction has following steps:
1. Initiation
2. Propagation
3. Termination
1) INITIATION: Under the influence of heat and/or chemical activators, the persulphate
bond breaks, giving a free radical. The radical then attacks the double bond of the monomer.
R-O-O-R 2 R-O
2) PROPAGATION: The radial reacts with one of the carbon atoms of the monomer with a
double bond. This leaves the second carbon with a free radical at other end to react with
another monomer unit.
R-O + M R-O-M
R-O-M + nM R-O-M-(M)n
3) TERMINATION: The reaction ends when two propagating units join, or when a radical
reacts with the propagating chain.
Coupling
R-O-(M)n + (M)m-O-R R-O-(M)m + n-O-R
PREFEASIBILITY REPORT
9 ABC/DOW/PFR/VER2.0
These latex products are a mixture of polymers are used in applications for Textile
processing, Water based Latex Coatings, Paper Coatings, etc., as a low VOC replacement for
solvent based polymers. The special features of our Latex Polymers are an improvement of
properties of many of the products made in India. This makes these products more cost and
quality competitive in both domestic and international markets.
Figure 3.1 Process Flow Chart [Existing – 40000 MT/Year]
PREFEASIBILITY REPORT
10 ABC/DOW/PFR/VER2.0
Figure 3.2 Process Flow Chart [After Expansion – 70000 MT/Year]
PREFEASIBILITY REPORT
11 ABC/DOW/PFR/VER2.0
3.4 MATERIAL BALANCE CHART [EXISTING – 40000 MT/YEAR]
PREFEASIBILITY REPORT
12 ABC/DOW/PFR/VER2.0
MATERIAL BALANCE CHART [AFTER EXPANSION – 70000 MT/YEAR]
Basis: Per Day
3.5 INFRASTRUCTURE REQUIREMENTS
A. PROCESS EQUIPMENTS:
i. Monomer Storage Tanks:
These are the tanks where the monomers will be stored. They will be transferred from
conventional road tankers or iso containers. Monomer Unloading will be done with vapour
return to the truck to eliminate emissions and odour during operations.
ii. Additive Tanks:
Various additive solutions, catalyst, activator solutions are made in these tanks in cold water.
There is no reaction or heat generation in these vessels.
iii. Monomer Emulsion Tanks:
PREFEASIBILITY REPORT
13 ABC/DOW/PFR/VER2.0
These are the tanks where monomer emulsion is prepared. Water is initially charged from
storage tank surfactants are charged to these tanks. Monomers are charged through a mass
meter from the monomer storage tanks. The contents are mixed until a stable mixture is
formed.
iv. Reactor:
The reaction is carried out in the reactor. A charge of water is initially added to the reactor. A
proportion of monomer emulsion is then transferred to the reactor from the monomer
emulsion tanks Catalyst, the activator is added from the additive tanks. The reaction
commences with some exotherm immediately the monomer emulsion, catalyst activator
solution feed is started and continued over the time prescribed in the Standard Operating
Procedure. The reaction is considered complete once the feeds are completed. The Heart of
reaction is removed from the reactor with cooling water running on limper coil of the reactor.
v. Drain Tank:
This is the vessel where the processing is finished. Once the reaction is completed in the
reactor the batch is transferred to the blend tank. Additives are added to this tank. Biocides
are added to the product in this vessel. Samples are taken from this vessel and analyzed.
Cooling is applied with cooling water in the limper coil of the vessel. For proposed
expansion activity, one additional drain tank will be installed.
vi. Latex Cake Separation:
The latex wash water from the process is collected and is coagulated in coagulation pits. The
Latex cake thus generated is separated in a separation process using filter press and the
separated water is sent to the effluent treatment plant. The latex cake is packed into
containers.
B. UTILITIES AND OTHERS
1. Boiler / Cooling Tower
2. Effluent Treatment Plant
3. Empty Raw Material container handling area
4. Electric Sub Station
5. MCC Room
6. R.O. Units ( Raw water and Recycle)
7. Fire Water Area
8. Administration Building & Security Area
PREFEASIBILITY REPORT
14 ABC/DOW/PFR/VER2.0
Table 3.3 List of Equipments
S. No Description Capacity
40000 MT/Annum (Existing)
70000 MT/ Annum (Future)
1 Storage tanks for Monomers 3 No change 2 Transfer Pumps 6 No change
3 Reactor feed tanks with agitator
2 No change
4 Additives tanks with agitator 6 No change
5 Additives Pumps 6 No change
6 Heat exchangers & pumps (lot)
4 6
7 Reactor with agitator 1 No change 8 Drain tank with agitator 1 2
9 DCS and Instrumentation(lot)
1 No change
10 Scrubber system-lot 1 No change
11 Product storage tanks 6 No change
12 Drumming Tank 1 No change
13 Cooling Tower /Pumps 1 No change
14 Water Storages/pumps 2 No change
15 RO Water system 2 3 16 Waste RO System 1 No change
15 Fire water storage/pumps 1 No change
16 Air compressor 2 No change
17 Air Receivers 2 No change
18 Boiler/stack 1 No change
19 ETP system- lot 1 No change
20 Triple effect Evaporator system
1 No change
PREFEASIBILITY REPORT
15 ABC/DOW/PFR/VER2.0
Figure 3.3 Site layout
PREFEASIBILITY REPORT
16 ABC/DOW/PFR/VER2.0
3.5.1 MANPOWER
The existing manpower is of about 31 Nos. Additionally, 3 Nos. will be deployed for the
expansion activity. After expansion, the totaling manpower will be 34 Nos. Currently 85
contract labours are working, additionally, 15 contract labours will be employed for the
expansion activity.
3.5.2 POWER
The Power requirement is 900 KVA sourced through TANGEDCO. DG set details are given
below. For the expansion activity, no additional power will be required.
Table 3.4 Details of DG sets
SL.NO. Equipment Capacity (KVA)
1 DG Set - 1 320
2 DG Set - 2 500
3.5.3 WATER REQUIREMENT
The unit proposes to consume 236 KLD of Fresh water. The entire quantity of raw water will
be supplied by SIPCOT. Water balance table for the operation of the existing & proposed
plant is as follows.
Table 3.5 Water Balance
S. NO. PARTICULARS
WATER REQUIREMENT (KLD)
EXISTING AFTER EXPANSION
1 Process 77 218 2 Cleaning & Vessel Washing 79 105 3 Cooling 64 112 4 Domestic 10 16
ACTUAL REQUIREMENT 235 451 FRESH WATER REQUIREMENT 114 236 COMBINED TREATED EFFLUENT I (ETP WITH RO) 101 173.5
COMBINED TREATED EFFLUENT II (MEE CONDENSATE) 20 41.5
TOTAL WATER REQUIREMENT 235 451
PREFEASIBILITY REPORT
17 ABC/DOW/PFR/VER2.0
Figure 3.4 Water balance chart (After Expansion)
PREFEASIBILITY REPORT
18 ABC/DOW/PFR/VER2.0
Initiatives for water reduction:
• The plant had implemented a scheme for source reduction of water coming from
washings by articulating a recycle scheme. The washings containing product are
collected hygienically directly from vessels and recycled appropriately to respective
products resulting in savings in water and reducing the load on effluent treatment
thereby accruing water, energy and treatment chemicals savings.
• The plant uses a cooling Air Handling unit for circulating temperature controlled air
to control room, Cold Storage room, panel room and in laboratories to keep a near
sterile atmosphere and pressurization. The cooling condensate water which was going
to drain is now collected in a tank and recycled to boiler feed after ensuring the
quality through checks.
• Steam is used to heat the water for direct use in the process in a heat exchanger and
the condensate is now collected and pumped back to boiler feed.
• The plant is having a zero discharge and is successfully recycling the entire water
back to plant use since inception.
• The plant has a rain water collection pit (1000 KL) and the water collected is tested
and put back into the water system. This collection pit is also connected to storm
drains from various locations.
• A close control is kept and a task force from the plant team is working on many
schemes on internal water recycles which will be implemented in due course.
PREFEASIBILITY REPORT
19 ABC/DOW/PFR/VER2.0
3.5.4 POLLUTION CONTROL MEASURES
3.5.4.1 AIR (EMISSIONS)
For existing plant, the following measures are taken up for control of gaseous emissions:
• The existing emission sources i.e., Polymer plant, Boiler, D.G sets are designed with
adequate stack heights and air pollution control measures to meet the standards set by the
TNPCB / CPCB.
Table 3.6 Details of air pollution control measures
S. No. Stack No Source Contro1
Measures Top
dimension
Height above
GL
Material of Construction
Exit Gas
Velocity (m/s)
Exit Gas
Temp
Max Discharge
(Cubic meter/min)
1. 1
Stack Attached to
Polymer Plant
Wet scrubber with a stack
0.4 35 Mild Steel 21.4 40 453
2. 2 Stack Attached
to Boiler 2 tons/hr capacity
Stack 0.3 45 Mild Steel & Stainless Steel 6.6 135 2090
3. 3 Stack Attached
to DG Set 320KVA
Stack 0.15 16 Mild Steel 7.2 170 850
4. 4 Stack Attached to DG Set 500
KVA Stack 0.15 16 Mild Steel 7.8 170 1090
The proposed air emissions generated from the above process will be treated in the existing
Air Pollution Control (APCS) System. The adequacy of the existing APC is sufficient for the
proposed activities
3.5.4.2 POSSIBLE FUGITIVE EMISSION SOURCES:
- Chemical storages
- Chemical transfer/charging from drums
- Process reactor vent
- Laboratory testing
Fugitive emissions control Measures:
• All monomer storage tanks are equipped with breather valves and intake and transfer
are in closed system adhering to highest safety standards.
PREFEASIBILITY REPORT
20 ABC/DOW/PFR/VER2.0
• For all chemicals charging through drums or other chemical containers chemical
charging booths connected to a caustic scrubber. VOC is monitored continuously in
the area and hooked up to Tamil Nadu Pollution control board Control room.
• Local exhaust ventilation system has been provided for chemicals/ powders
transferring to control fugitive emissions.
• The main Reactor equipped with a condenser for vapors and pressure relief system to
prevent any emissions from the process. Also, intermediate vessels handling raw
materials are equipped with breather valves (VPRV) to prevent emissions.
• In laboratories, lab hoods have been provided for all chemical analysis.
• Performance and face velocities for all LEVs, charging booths and lab hood is
periodically monitored.
3.5.5 WASTE GENERATION
3.5.5.1 WASTE WATER GENERATION DETAILS & MANAGEMENT
S. No. Particulars Water Generated
(KLD) Existing After Expansion
1. Process Effluent 79 138 2. Sewage 8.0 12.8
3. Utilities a. Boiler Blow down 2 3.0 b. Cooling tower bleed 13.0 19.8
These are three waste water streams generated namely, Process, Utility and Sewage
streams. These streams are collected separately and fed into the Effluent treatment plant
appropriately. The treated effluent is further processed in Reverse Osmosis plant.
The permeate from the R.O plant will be recycled and rejection will be evaporated by the
Mechanical Evaporator and Solar Evaporation Pan. The current effluent treatment
system is sufficient enough to handle the expansion activities.
PREFEASIBILITY REPORT
21 ABC/DOW/PFR/VER2.0
3.5.5.2 SOLID WASTE (HAZARDOUS & NON-HAZARDOUS WASTES)
The solid waste generated from existing & proposed expansion is as follows: Hazardous Waste Generation
S.N
Name of Process Waste(Category No)
Quantity Waste Type Waste
Storage Waste Disposal Source of
generation of waste
Physical status Existing After
Expansion
1 5.1-Used or spent oil 2 T/Annum
3.5 T /Annum Recyclable MS Drums Recovery and Reuse- Authorized recyclers
Pump Seal Oil
Transformer Oil
Oily
2
20.1-Contaminated aromatic, aliphatic or
naphthenic solvents may or may not be fit for
reuse
40 T/Annum
70 T /Annum Incinerable MS Drums
Incineration- TSDF,
Gummidipoondi
Expired Raw Materials Liquid
3
33,1-Empty barrels/containers/liners
contaminated with hazardous
chemicals /wastes
250 T/Annum
437.5 T /Annum Recyclable
Concrete Surface with Impervious
Layer
Recovery and Reuse- Authorized recyclers
Empty Raw material
Drums Solid
4
33,1-Empty barrels/containers/liners
contaminated with hazardous
chemicals /wastes
2 T/Annum
3.5 T /Annum Incinerable MS Drums Incineration-
TSDF, Gummidipoondi
Bag liners which are
contaminated with
chemical powders
Solid
5 35.3-Chemical sludge from
waste water treatment
1 T/Annum
1.75 T /Annum Landfillable Plastic Drums Common Landfill-
TSDF, Gummidipoondi
Effluent Treatment
Plant sludge Solid
6 35.3-Chemical sludge from
waste water treatment
1 T/Annum
1.75 T /Annum Landfillable Plastic Drums Common Landfill-
TSDF, Gummidipoondi
ETP - Evaporator
Residue Solid
PREFEASIBILITY REPORT
22 ABC/DOW/PFR/VER2.0
Non Hazardous Waste Generation
Description of Non- Hazardous Waste
Qty of waste Generated (Kgs)
(Existing)
Qty of Waste Generated (kgs)
(After Expansion)
Discharged from
Accumulated Qty. (Kgs)
Disposal Method
Equipment/ facility used
Wooden & Card board / Paper scraps
1,000 1800 Logistics & office
Nil Recycled Approved Vendor
Metal scraps 930 1700 - Nil Recycled Approved
vendor
PREFEASIBILITY REPORT
23 ABC/DOW/PFR/VER2.0
3.6 RAINWATER HARVESTING & STORMWATER MANAGEMENT
The existing rainwater collection system & storm water management will be continued
effectively.
o Storm water drains have been provided along the factory to ensure that this is
totally separated from process effluent. This will minimize runoff of the
contaminated water to the land surrounding the site.
o Runoff from roof top area is collected by means of down take pipes and diverted
to rain water collection pit (1000 KL), the water collected is tested for its quality
and reused accordingly.
o The surface runoff is diverted to the channel provided along the site boundary and
discharged in the external storm water drain.
3.7 FUEL REQUIREMENT
S. No Name of fuel points of use Quantity (T/d)
Existing proposed
1 Diesel Diesel Generators 0.250 0.437
2 Furnace Oil Boiler Fuel 0.7 1.2
3 GREENBELT DEVELOPMENT
Well-developed greenbelt totaling 35% of plot area is maintained. This will be further
strengthened during the expansion activity.
4 ENVIRONMENTAL MANAGEMENT PLAN
Table 5.1 EMP budget
S. No. Infrastructure Capital cost* ( lakhs)
Recurring cost (Lakhs)
1. Air Pollution Control 100 5
2. Effluent Treatment Plant (ETP) & Rain water harvesting measures
350 15
3. Environment Monitoring and
Management 20 2
4. Solid and Hazardous Waste
Management 15 5
5. Occupational Health & Safety 25 7.5 6. Green belt Development 20 5
Total 530 39.5 * Existing and no changes for proposed
PREFEASIBILITY REPORT
24 ABC/DOW/PFR/VER2.0
5 PROJECT COST & IMPLEMENTATION SCHEDULE
The cost for the proposed expansion is estimated at 6 Crores. After obtaining Environmental
Clearance (EC) and Consent to Establish for the proposed expansion, construction activity
will be commenced.