Dot XL-6 / XL-9
INSTALLATION GUIDE
V0.8
Cover:
Dot XL-6
Dot XL-6 Diffuser Version
Dot XL-9
Dot XL-9 Diffuser Version
www.traxontechnologies.com©2015 traXon teChnoLogies - an osraM Business. aLL rights reserVeD. traXon™, tX ConneCt®, are traDeMarks of traXon teChnoLogies. u.s. patents, e.u. patents, japan patents, other patents penDing. speCifiCations are suBjeCt to Change without notiCe.
installation guide 08/15 V0.8 2 of 20
Content
1. introDuCtion 3
2. instaLLation 6
3. safety anD operation 14
4. systeM Configuration 15
5. Care anD MaintenanCe 17
6. teChniCaL speCifiCation 18
7. trouBLeshooting 19
8. warranty stateMent 19
www.traxontechnologies.com©2015 traXon teChnoLogies - an osraM Business. aLL rights reserVeD. traXon™, tX ConneCt®, are traDeMarks of traXon teChnoLogies. u.s. patents, e.u. patents, japan patents, other patents penDing. speCifiCations are suBjeCt to Change without notiCe.
installation guide 08/15 V0.8 3 of 20
INTRODUCTION1.
General1.1
the traxon™ Dot XL is an extra bright dot with 6 or 9 LeDs per dot casing. the dots are constructed on a flexible cable with a customizable pitch. with numerous additional customization options, the Dot XL’s flexibility is unparalleled and its application possibilities nearly limitless. the dots are single dot controllable by DMX512 or e:pix (DVi capable) making this durable, scalable solution equally ideal for vivid accent, text, graphics, and video replay in installations of any size and complexity. each string is connected via the Dot XL pixel Distributor which can be easily daisy chained to form large installations.
the ip67-rated, uV-resistant cover and aluminium casing make the Dot XL suitable for a variety of outdoor applications.
features:
DMX512 / e:pix Control• Daisy Chain system• auto-addressing• sMart Chip™ technology• outdoor applications (Dot XL ip66/ip67; pixel Distributor ip66; LeD engine ip67)• suitable for irregular surfaces, planes, and configurations• optional field-cut end cap for cable• optional Diffuser Dome available•
www.traxontechnologies.com©2015 traXon teChnoLogies - an osraM Business. aLL rights reserVeD. traXon™, tX ConneCt®, are traDeMarks of traXon teChnoLogies. u.s. patents, e.u. patents, japan patents, other patents penDing. speCifiCations are suBjeCt to Change without notiCe.
installation guide 08/15 V0.8 4 of 20
Dimensions1.2 Dot XL-6 / XL-9fig.1:
15.6mm/0.61”
3.3mm/0.13”
3.2mm/0.13”
16.5mm/0.65”
58mm/2.28”
66mm/2.60”
Ø66
mm
/2.6
0”
1.2mm/0.05”
8mm/0.31”
Ø4.2mm/0.17”
R20.4mm/0.80”
VERSION WITHDIFFUSER DOME
36mm/1.42”
14.6mm/0.57”
Dot XL-6 / XL-9 stringfig.2:
66mm/2.6”16.5mm/0.65”
3.3mm/0.13”15.6mm/0.6”
3.2mm/0.1”
58mm/2.3”
265mm/10.4”
~5000mm/197”
3.3mm/0.13”15.6mm/0.6”
36mm/1.42”
With Diffuser Dome
R20.4m
m/0.80”
www.traxontechnologies.com©2015 traXon teChnoLogies - an osraM Business. aLL rights reserVeD. traXon™, tX ConneCt®, are traDeMarks of traXon teChnoLogies. u.s. patents, e.u. patents, japan patents, other patents penDing. speCifiCations are suBjeCt to Change without notiCe.
installation guide 08/15 V0.8 5 of 20
Pixel Distributor1.3 pixel Distributorfig.3:
222mm/8.7”
204mm/8”
20m
m/0
.79”
9mm
/0.3
5”
198mm/7.8”
Cable length: 1000mm/39.4”
Cable length:300mm/11.8”
Ø6.3mm/0.25” x 4
M4 x 4
50m
m/2
”
89m
m/3
.5”
68mm/2.7”
LeD engine
pixelDistributor
Packing Contents1.4 packing Contentsfig.4:
Dot XL String
1 x Pixel Distributor 4 x Screws PSU Mounting
www.traxontechnologies.com©2015 traXon teChnoLogies - an osraM Business. aLL rights reserVeD. traXon™, tX ConneCt®, are traDeMarks of traXon teChnoLogies. u.s. patents, e.u. patents, japan patents, other patents penDing. speCifiCations are suBjeCt to Change without notiCe.
installation guide 08/15 V0.8 6 of 20
INsTallaTION2.
Points To Consider2.1
plan your installation before mounting any luminaires. the following should be considered for a successful installation.
weather conditions and ambient temperature of installation site.• appropriate cable lengths and the use of optional field-cut end caps.• adequate space for better heat dissipation (150mm apart) of LeD engines (see 2.3 on-site • installation step 1).
appropriate anchor bolts where necessary to secure the Dot XLs.• the number of Dot XLs and appropriate pixel Distributors with LeD engines.• DMX512 controller to be used to control the Dot XLs.•
Pre-Installation Checks2.2
Installation Checklist2.2.1
prepare cables and all necessary accessories.1.
perform functional check of Dot XLs.2.
ensure the Data out connector on all pixel Distributors are covered by the waterproof 3. end Cap after testing (see fig 5). keep waterproof end Caps safe for reuse.
ensure all pre-installation checks laid out below have been followed.4.
Mount the Dot XLs on-site. if the installation is to be left uncompleted overnight, place all 5. non-connected LeD engines, pixel Distributors and Dot XLs in an indoor environment.
ensure all the Connection Cables, Dot XLs with LeD engines and pixel Distributors are initially stored in a dry area to guarantee the complete sealing of the system from water before installation.
www.traxontechnologies.com©2015 traXon teChnoLogies - an osraM Business. aLL rights reserVeD. traXon™, tX ConneCt®, are traDeMarks of traXon teChnoLogies. u.s. patents, e.u. patents, japan patents, other patents penDing. speCifiCations are suBjeCt to Change without notiCe.
installation guide 08/15 V0.8 7 of 20
Connector should be properly connected with cable connectors and the Data out of the last pixel Distributor should be covered by its waterproof end Cap to ensure ip66/67 rating.
seal last pixel Distributor with waterproof end Capfig.5:
Waterproof End Cap
Tightening Torque0.49~0.69Nm (5~7kgfcm)
Handling The Dot Xl string2.2.2
when transporting or preparing the Dot XL string, please handle with care. to reduce stress on cables, carry by the dots and not the cable during transit.
Correct way of handling Dot XL stringfig.6:
Allow slack on cable to reduce stress
Allow slack on cable to reduce stress
www.traxontechnologies.com©2015 traXon teChnoLogies - an osraM Business. aLL rights reserVeD. traXon™, tX ConneCt®, are traDeMarks of traXon teChnoLogies. u.s. patents, e.u. patents, japan patents, other patents penDing. speCifiCations are suBjeCt to Change without notiCe.
installation guide 08/15 V0.8 8 of 20
Requirements Of Cable Bending and Twisting2.2.3
please take eXtra precautions before bending or twisting Dot XL cable.
round Lead Cable must not be bent below the Minimum Bending radius (4x Cable Diameter) and the non-Bendable Length of 50mm near the connector end or near the cable overmold Must be adhered to.
Minimum Cable Bending and non-Bendable Length requirementfig.7:
(Minimum Bending Radius)38mm/1.50”
D
Ø9.5mm/0.37”≥4D
(Non-Bendable Length)
50mm/1.97”
the flat Dot XL Cable must not be bent/twisted below 20mm (0.79”) from edge of Dot housing (non-Bendable/non-twistable Length).
twisting the flat cable is not recommended. if twisting is necessary for installation, please adhere to the above non-twistable Length and ensure the mounting pitch is greater than or equal to 75% of the normal Dot to Dot pitch. the middle part of the cable must be secured to the mounting fixture with a cable tie (see 2.3 on-site installation steps 6-7 and figs 12-13). ensure no damage is generated on the cable.
Minimum Clearancefig.8:
20mm/0.79”
Minimum clearance from dot
Non-Bendable/Non-Twistable Length
note: water ingress incurred due to excess cable bending/twisting will not be under warranty by traxon technologies.
www.traxontechnologies.com©2015 traXon teChnoLogies - an osraM Business. aLL rights reserVeD. traXon™, tX ConneCt®, are traDeMarks of traXon teChnoLogies. u.s. patents, e.u. patents, japan patents, other patents penDing. speCifiCations are suBjeCt to Change without notiCe.
installation guide 08/15 V0.8 9 of 20
Optional Field-Cut End Cap2.2.4
to prematurely end the length of a string of Dots, the optional field-Cut end Cap should be used with silicone applied on open-ended cable. this should be done at least one (1) day before on-site installation to allow curing of silicone.
field-Cut sealing proceduresfig.9:
terminate cable with a straight cut. ensure there is enough clearance to work with. Clean the surface using alcohol.
1
35mm/1.38”
Minimum clearance from last node
apply rtV silicone (not included) on open-ended cable.
2
RTVSILICONE
RTVSILICONE
fill end cap cavity with rtV silicone and press open cable end inside.
3
(DO.AC.0003600)
RTVSILICONE
RTVSILICONE
RTVSILICONE
Cover parts with rtV silicone and close cover.
4
RTVSILICONE
Clean excess silicone from end cap.
5 place on flat surface and put pressure on end cap (eg. with a weighted object) for the cure time recommended by rtV silicone’s instructions.
6
www.traxontechnologies.com©2015 traXon teChnoLogies - an osraM Business. aLL rights reserVeD. traXon™, tX ConneCt®, are traDeMarks of traXon teChnoLogies. u.s. patents, e.u. patents, japan patents, other patents penDing. speCifiCations are suBjeCt to Change without notiCe.
installation guide 08/15 V0.8 10 of 20
Installation sequence2.2.5
plan for any possible bending of cables (refer to section 2.2.3 requirements of Cable 1. Bending and twisting).
always keep the waterproof end Cap on the pixel Distributors or keep them safe in a 2. container for reuse.
Connect Dot XLs with LeD engines and pixel Distributors in the daisy-chain manner 3. outlined in the system Diagram to form large installations.
perform functional check on all Dot XLs and inspect cables for any damage. Check for 4. any abnormalities with the signal.
report any functional defect found to your nearest traxon technologies office. Do not 5. attempt to install Dot XLs with functional defects on-site.
www.traxontechnologies.com©2015 traXon teChnoLogies - an osraM Business. aLL rights reserVeD. traXon™, tX ConneCt®, are traDeMarks of traXon teChnoLogies. u.s. patents, e.u. patents, japan patents, other patents penDing. speCifiCations are suBjeCt to Change without notiCe.
installation guide 08/15 V0.8 11 of 20
On-site Installation2.3
Do not attempt installation in wet or severe weather conditions.• Do not leave and expose any Dot XL, pixel Distributor or LeD engine • unconnected under wet/raining or snowing environment.
ensure all the cable connectors of Dot XLs are removed from the pixel • Distributors before installing.
Do not pull on cable of Dot XLs. ip failure induced by stressed/damaged • cables during or after installation will not be under warranty by traxon technologies.
aLways keep the cables protected from sharp objects and ensure no • damage is generated on the cable.
failure to keep Dot XLs within the operating temperature range of –20°C • to 50°C (–4°f to 122°f) and storage temperature range of –20°C to 70°C (–4°f to 158°f) will void the product’s warranty.
fix LeD engine atop pixel Distributor with included M4 screws. 1. note: keep adjacent LeD engines and pixel Distributors a minimum 150mm (5.91”) apart for better heat dissipation.
Mounting LeD engine atop pixel Distributorfig.10:
LED Engine mountson top of the Pixel Distributor
M4 screws(Included)
(Not included)M6 anchor bolts
(LED Engine is ordered separately)
Mount Pixel Distributorwith connectors facing down
≥150mm/5.91”clearance
≥150mm/5.91”clearance
≥150mm/5.91”clearance
≥150mm/5.91”clearance
≥150mm/5.91”clearance
≥150mm/5.91”clearance
Mount the pixel Distributor with 4x M6 anchor Bolts (not included). recommended 2. orientation is with connectors facing Down (see above diagram).
Dot XLs must be mounted without any stress induced at the boundary area of the cable 3. and Dot.
www.traxontechnologies.com©2015 traXon teChnoLogies - an osraM Business. aLL rights reserVeD. traXon™, tX ConneCt®, are traDeMarks of traXon teChnoLogies. u.s. patents, e.u. patents, japan patents, other patents penDing. speCifiCations are suBjeCt to Change without notiCe.
installation guide 08/15 V0.8 12 of 20
Dots Must be mounted to the installation surface via the mounting holes, either by 4. screw or cable tie.
Mounting the Dot XLsfig.11:
(Screws not included)
Suggested alternative method if screws are not viable
(Cable ties not included)
(Screws not included)
Suggested alternative method if screws are not viable
(Cable ties not included)
Cable segment must not be bent below 20mm from the housing of the Dot XLs and 5. cable overmold (Minimum Bending Length).
secure the cables between Dot XLs (approximately halfway, using cable tie) and create a 6. small clearance beneath the cable (see below diagram). ensure no damage is generated on the cable.
securing the cablefig.12:
Observe clearance
Cable tie
Mounting surface
www.traxontechnologies.com©2015 traXon teChnoLogies - an osraM Business. aLL rights reserVeD. traXon™, tX ConneCt®, are traDeMarks of traXon teChnoLogies. u.s. patents, e.u. patents, japan patents, other patents penDing. speCifiCations are suBjeCt to Change without notiCe.
installation guide 08/15 V0.8 13 of 20
if the cable between Dot XLs requires twisting due to a change in mounting direction, 7. ensure the mounting pitch after-twisting is more than or equal to 75% of the normal Dot to Dot pitch.
twisting requirementsfig.13:
≥75% LNon-Twistable Length20mm/0.79”
L = Length of cable
Secure center ofcable with cable tie
≥75% LNon-Twistable Length
20mm/0.79”
L = Length of cable Non-Twistable LengthSecure center ofcable with cable tie
www.traxontechnologies.com©2015 traXon teChnoLogies - an osraM Business. aLL rights reserVeD. traXon™, tX ConneCt®, are traDeMarks of traXon teChnoLogies. u.s. patents, e.u. patents, japan patents, other patents penDing. speCifiCations are suBjeCt to Change without notiCe.
installation guide 08/15 V0.8 14 of 20
saFETy aND OPERaTION3. Caution - unplug the power supply from the mains power before connecting any 1. cables as this can damage the products.
Caution - avoid looking directly into the LeD light source at close range for your own 2. safety.
persons installing this product should make sure:3.
the installation complies with all applicable codes, state and local laws, 1.
ordinances, standards and safety regulations.
the installation environment is carefully studied and suitable surge protection 2.
measure(s) is taken.
he or she is qualified for the handling of electrical equipment.3.
Do not attempt to install or use the product until installation instructions and safety labels 4. are fully understood. this product is designed for indoor and outdoor use.
ensure product operates within the specified temperature range. (refer to 6. teChniCaL 5. speCifiCation for more details.)
Do not attempt to open the product. not user serviceable.6.
Do not use the product if any part of it, or the power cables are damaged.7.
only use product for specified voltage, do not exceed. (refer to 6. teChniCaL 8. speCifiCation for more details.)
always maintain connection to ensure waterproofing.9.
if the product has been subjected to drastic temperature variances, for example, 10. following transportation, do not connect the fixture until it has reached room temperature, as moisture condensation may cause electric shock and product damages.
when installing the products and system power supplies, please ensure they will not 11. be exposed to moisture and extreme heat (and direct sunlight for outdoor products). Besides, keep a clean operating environment for the fixtures and system power supplies.
please study this installation guide thoroughly and check the latest technical 12. specification sheets available from the traxon website www.traxontechnologies.com before setup.
any non-compliance of the installation guide will void the traxon warranty.13.
www.traxontechnologies.com©2015 traXon teChnoLogies - an osraM Business. aLL rights reserVeD. traXon™, tX ConneCt®, are traDeMarks of traXon teChnoLogies. u.s. patents, e.u. patents, japan patents, other patents penDing. speCifiCations are suBjeCt to Change without notiCe.
installation guide 08/15 V0.8 15 of 20
sysTEM CONFIGURaTION4. system Diagram – Butler s2fig.14:
512
DM
X C
hann
els
per o
utpu
t
But
ler S
2
CO
NTR
OLL
ER
IND
OO
RO
UTD
OO
R
AC
110
V/22
0V 5
0/60
Hz
Inst
alla
tion
engi
neer
sho
uld
use
appr
opria
te p
lugs
for o
utdo
or c
onne
ctio
n.
TX C
onne
ct D
ata
Out
door
Cab
le0.
3m/1
ft or
3m
/10f
t ava
ilabl
e
Max
imum
num
ber o
f Pix
el D
istri
buto
rs in
the
dais
y ch
ain
depe
nds
on a
vaila
ble
DM
X an
d e:
pix
chan
nels
.
Dot
pitc
h: 1
00m
mm
inim
um
Flat
lead
cab
le:
1PXL
dot
s3
chan
nels
per
dot
Last
dot
of s
tring
Firs
t dot
of s
tring
DM
X A
ddre
ss:
Firs
t 3 c
hann
els
of s
tring
Rou
nd le
ad c
able
: 300
mm
For s
tand
ard
25-D
ot X
L-6
with
300
mm
pitc
h,m
ax. l
ead
cabl
e le
ngth
is 5
m.
Dot
XL
Pixe
l Dis
tribu
tor
LED
Eng
ine
75W
15V
Out
door
End
cap
TX C
onne
ct D
ata
Indo
or/O
utdo
or B
ridge
Cab
le (5
m/1
6.4f
t)
To o
ther
dis
tribu
tor c
hain
Max
imum
: 100
m
Max
imum
lead
cab
le le
ngth
dep
ends
on th
e nu
mbe
r of d
ots
and
the
dot p
itch.
To c
onst
ruct
a lo
nger
Dat
a B
ridge
Cab
le,
use
Indo
or D
ata
Cab
le a
nd O
utdo
or
RJ4
5 H
ousi
ng.
RJ4
5 M
ale
Con
nect
or H
ousi
ng IP
67
1000
mm
/39.
4”
300m
m/1
1.8”
But
ler
S2
www.traxontechnologies.com©2015 traXon teChnoLogies - an osraM Business. aLL rights reserVeD. traXon™, tX ConneCt®, are traDeMarks of traXon teChnoLogies. u.s. patents, e.u. patents, japan patents, other patents penDing. speCifiCations are suBjeCt to Change without notiCe.
installation guide 08/15 V0.8 16 of 20
system Diagram – Video Micro Converterfig.15:
IND
OO
RO
UTD
OO
R
AC
110
V/22
0V 5
0/60
Hz
Inst
alla
tion
engi
neer
sho
uld
use
appr
opria
te p
lugs
for o
utdo
or c
onne
ctio
n.
TX C
onne
ct D
ata
Out
door
Cab
le0.
3m/1
ft or
3m
/10f
t ava
ilabl
e
Max
imum
num
ber o
f Pix
el D
istri
buto
rs in
the
dais
y ch
ain
depe
nds
on a
vaila
ble
DM
X an
d e:
pix
chan
nels
.
Dot
pitc
h: 1
00m
mm
inim
um
Flat
lead
cab
le:
1PXL
dot
s3
chan
nels
per
dot
Last
dot
of s
tring
Firs
t dot
of s
tring
DM
X A
ddre
ss:
Firs
t 3 c
hann
els
of s
tring
Rou
nd le
ad c
able
: 300
mm
For s
tand
ard
25-D
ot X
L-6
with
300
mm
pitc
h,m
ax. l
ead
cabl
e le
ngth
is 5
m.
Dot
XL
Pixe
l Dis
tribu
tor
LED
Eng
ine
75W
15V
Out
door
1000
mm
/39.
4”
300m
m/1
1.8”
End
cap
Max
imum
lead
cab
le le
ngth
dep
ends
on th
e nu
mbe
r of d
ots
and
the
dot p
itch.
Max
imum
: 100
m
TX C
onne
ct D
ata
Indo
or/O
utdo
or B
ridge
Cab
le (5
m/1
6.4f
t)
DVI
So
urce
Ethe
rnet
Sour
ce
DVI
IN (D
VI-D
/DVI
-I)
DVI
IN (D
VI-D
/DVI
-I)
DVI
OU
T
DVI
OU
T
Ethe
rnet
Sw
itch
Each
out
put:
1536
cha
nnel
s.To
tal o
n 8
outp
uts:
122
88 c
hann
els.
Onl
y 6
outp
uts
are
avai
labl
e if
confi
gure
dfo
r 204
8 ch
anne
ls p
er o
utpu
t.
Max
imum
8 o
utpu
ts.
Vide
o M
icro
Con
verte
r (VM
C)
DA
ISY-
CH
AIN
ED V
MC
sM
AX.
UN
ITS
PER
CH
AIN
: 8
USE
DVI
SPL
ITTE
R F
OR
FU
RTH
ER V
MC
CH
AIN
S
SEE
VMC
SPE
CIF
ICA
TIO
N F
OR
MO
RE
INFO
RM
ATI
ON
To c
onst
ruct
a lo
nger
Dat
a B
ridge
Cab
le,
use
Indo
or D
ata
Cab
le a
nd O
utdo
or
RJ4
5 H
ousi
ng.
RJ4
5 M
ale
Con
nect
or H
ousi
ng IP
67
LCE2
fx
www.traxontechnologies.com©2015 traXon teChnoLogies - an osraM Business. aLL rights reserVeD. traXon™, tX ConneCt®, are traDeMarks of traXon teChnoLogies. u.s. patents, e.u. patents, japan patents, other patents penDing. speCifiCations are suBjeCt to Change without notiCe.
installation guide 08/15 V0.8 17 of 20
CaRE aND MaINTENaNCE5.
traxon™ products are of superior design and quality and should be treated with care. the recommendations below will help fulfill any warranty obligations and gain good use and longevity from the products.
Do not attempt or use the product(s) until you read and understand the installation • instructions. failure to adhere to these instructions could result in serious injury or property damage.
Do not use product(s) if cables are damaged. • Do not connect cables and connectors when wet or in wet area. Moisture on bare • connectors can cause electric shock and damage to product(s).
Do not use product(s) in extreme heat environment. ensure there is sufficient airflow and • use cool air circulation if required.
Do not drop, knock, or shake product(s). rough handling can damage the electronics and • void the warranty.
Do not use harsh chemicals, cleaning solvents, or strong detergents to clean products. • wipe with a damp cloth on housings and a dry cloth on electronics to remove dirt or dust.
Do not attempt to service or repair the product(s) unless done by an authorized service • personnel. Contact your local traxon office or distributor for details.
if the product is not working as specified, please contact your nearest authorized service • center or traxon technologies office for assistance.
www.traxontechnologies.com©2015 traXon teChnoLogies - an osraM Business. aLL rights reserVeD. traXon™, tX ConneCt®, are traDeMarks of traXon teChnoLogies. u.s. patents, e.u. patents, japan patents, other patents penDing. speCifiCations are suBjeCt to Change without notiCe.
installation guide 08/15 V0.8 18 of 20
TECHNICal sPECIFICaTION6.
Model Dot XL-6 Dot XL-9
Color range: 16.7 million additive rgB colors with variable intensity
Light source: 6 / 9 high intensity nichia sMD LeDs per dot
Beam angle: 120° (clear cover) 170° (diffuser dome)
power input: 15V DC
power Consumption (per dot):
2.5w max. 3.5w max.
weight: 80g (Dot); 670g (pixel Distributor)
operating temperature: –20°C to 50°C / –4°f to 122°f
storage temperature: –20°C to 70°C / –4°f to 158°f
as with all electronic devices, LeD output degrades over time - a term called lumen depreciation. this also explains why it is nearly impossible to expect photometric performances of two LeD products with different service life spans to be the same. the rate of LeD degradation is a complex function of many factors such as operating efficiency, duration of continuous operation, and operating conditions (e.g. ambient temperature).
Because LeDs are semiconductor devices, their performances are subject to inherent variability commonly found in semiconductor industry. to improve consistency in performance across the same product, LeD manufacturers “sort” LeDs into bins according to different preset parameters, such as forward driving voltage, illumination, etc. whereas binning is a sorting function, it is not a correction process. inherent variability in the manufacturing process always results in different binning distributions according to different production lots. traxon uses automatically binned LeDs on its products, thereby minimizing output variations within the model range.
www.traxontechnologies.com©2015 traXon teChnoLogies - an osraM Business. aLL rights reserVeD. traXon™, tX ConneCt®, are traDeMarks of traXon teChnoLogies. u.s. patents, e.u. patents, japan patents, other patents penDing. speCifiCations are suBjeCt to Change without notiCe.
installation guide 08/15 V0.8 19 of 20
TROUBlEsHOOTING7.
Caution: ensure power supply is off when disconnecting / connecting cables.
Problem Cause Possible Solutionsproduct does not light up after installation
incorrect power connection
Check Mains power• Check power supply leads and wire • connections
ensure output wires are connected with • proper polarity
shadowing Light source covered adjust pitch between Dot XL strings• Check for cables, wires or unwanted • debris covering LeD light source
Modules are dim
excess products connected
ensure the power supplies are not • overloaded due to an excess of products connected
flickering incorrect power input/excess products connected
ensure the input voltage is correct• ensure the power supplies are not • overloaded due to an excess of products connected
if problems persist or the product is not working as specified, please contact your nearest authorized service center or traxon technologies office for assistance.
WaRRaNTy sTaTEMENT8.
traxon technologies warrants its products against material or workmanship defects for a period of three (3) years from date of purchase, provided that the purchased items are used under the conditions stated in this user manual.
please refer www.traxontechnologies.com for all warranty terms and conditions.
please check for the latest updates and changes on the traxon website.© 2015 traXon teChnoLogies aLL right reserVeD. information is subject to change without prior notice.www.traxontechnologies.com
Top Related