Features

Upto32Internalanalogueinputchannels

Upto32digitaland/oranalogueexternalchannels

Non-volatilestorageofchannelcalibrationdata

RealTimeclockwithbatterybackup

Upto250readingsperchannelwithtimestamp

Variableloggingmodesinclude:

• Configurablelineartimes

• Userconfigurabletabletimes

• Referencechannelincrementalmode

Automatictriggeringofdataloggingincluding:

• Configurabledelaytime

• Valuegreaterthanareferencechannelvalue

Automaticstoppingofdataloggingincluding:

• Configurabledelaytime

• Valuegreaterthanareferencechannelvalue

Automaticdatacollection

Automaticteststartandstopconditions

Onboardlargegraphicsdisplayandkeypad

Menudrivencommandselection

Onscreenlivedisplaysofgraphanddata tabulation

Passwordprotectedconfigurationandcalibration

Builtintransducerexcitationsupply

RS232serialinterfaceforcomputercontrol

CompatiblewithWindowsbasedClispStudio software

MPX3000DataLogger

MPX3000with4channeldigitaljunctionbox

The VJ Tech MPX3000 is a state of the art data logger ideally suited to Soil Mechanics Laboratories and is simple to use and flexible in operation. It can make a considerable improvement in laboratory productivity and cost effectiveness by automating test data collection, thus freeing the laboratory technician to perform other duties whilst the test is being conducted.

The MPX3000 data logger is supplied as a fully configurable system, which can be upgraded by adding channel modules. Up to 32 internal analogue channels, in blocks of 8 channels can be housed within the logger itself and a further 32 channels can be added externally by daisy chaining junction boxes each with 4 analogue or digital channels.

MPX3000DataLogger

VJT3000 MPX3000 Data Logger (basic unit without input channels)

VJT3000-8A 8 Channel Internal Analogue Module

VJT3000-4D-MIT 4 Channel External Digital Dial Gauge Module

AnalogueChannelInput LSCT, Pressure or Load Cell

DigitalChannelInput Digital Dial Gauge Input (Load, Strain or Volume)

TransducerExcitationSupply 10V DC

ComputerInterface RS232

LocalControlviaKeypad 20 keys

GraphicDisplay 240x128 pixels

Clock Battery backed real time clock

DataStorage Up to 12000 readings for a single channel test

PowerSupply 110-240VAC, 50/60Hz, 1ph

Dimensions(LxWxH) 380 x 450 x 150mm

Weight(kg) 8kg

OrderingInformation

VJT3000specifications

Accessories

DataLoggersandInterfaces

BuildingBetterTechnologyfortheCivilEngineeringIndustry

Page 2: Data Loggers Datasheet v2 (1)

VJTechLimitedUnit 1 io Trade Centre Deacon Way Reading RG30 6AZTel +44 118 945 3737 Fax +44 118 945 5209 Email [email protected] Web vjtech.co.uk

Features

On-boardbatterybackedmemoryfordatastorage andcalibration

RealTimeclockwithbatterybackup

Upto250readingsperchannelwithtimestamp

Variableloggingmodesinclude:

• Configurablelineartimes

• Userconfigurabletabletimes

• Referencechannelincrementalmode

Automatictriggeringofdataloggingincluding:

• Configurabledelaytime

• Valuegreaterthanareferencechannelvalue

Automaticstoppingofdataloggingincluding:

• Configurabledelaytime

• Valuegreaterthanareferencechannelvalue

Automaticdatacollection

Viewableloggeddata

Passwordprotectedconfigurationandcalibration

Transducerexcitationsupplyof+/-5VDC

RS232serialinterfaceforcomputercontrol

OptionalWindowsbasedCLISPStudiosoftware

MiniScanner2DataLogger

The VJ Tech MiniScanner2 is a simple to use four channel standalone data logging system specifically designed for use in soil testing laboratories. Data collection for tests such as Triaxial, Oedometer and Shearbox can be fully automated. Configuring the system is made easy by using a 4x4 membrane keypad with associated LCD display.

MiniScanner2DataLogger

The VJ Tech 4-Channel Digital Indicator PC Interface provides an interface for up to 4 Digital Dial Gauges to a USB port (via a USB to RS232 Interface) on a PC running Clisp Studio.

Also available are a 4-Channel Analogue PC Interface, a single channel Digital or Analogue PC Interface and a dual Analogue/Digital PC Interface.

This has the same specification as the VJT1000A MiniScanner2 except that it is designed as a dedicated CBR/Marshall Data Logger. Therefore, the unit has the added feature of ‘maximum hold’ but only requires 2 channels.

AnalogueandDigitalPCInterfaces

AnalogueChannelInput LSCT, Pressure or Load Cell

TransducerExcitationSupply 10V DC

ComputerInterface RS232

LocalControlviaKeypad Yes

GraphicDisplay Yes

PowerSupply 110-240VAC, 50/60Hz, 1ph

Dimensions(LxWxH) 280 x 350 x 150mm

Weight(kg) 6kg

VJT1000A MiniScanner2 4 Channel Data Logger

VJT1300A MiniScanner 2 Channel Data Logger for CBR/Marshall

VJT1000ASpecifications

OrderingInformation

VJT1010-4D 4-Channel Digital Indicator PC Interface (includes USB to RS232 Converter, Power Supply and RS232 cable)

VJT1010-4A 4-Channel Analogue transducer PC Interface (includes USB to RS232 Converter, Power Supply and RS232 cable)

VJT1010-1D Single Channel Digital Indicator PC Interface (includes USB to RS232 Converter, Power Supply and RS232 cable)

VJT1010-1A Single Channel Analogue transducer PC Interface (includes USB to RS232 Converter, Power Supply and RS232 cable)

VJT1010-1AD 2 Channel (1 x Analogue, 1 x Digital) PC Interface (includes USB to RS232 Converter, Power Supply and RS232 cable)

AnalogueandDigitalPCInterfaceOrderingInformation

4-Channel Digital Indicator PC Interface