Detection of Control Flow ErrorsSurvey of Hardware and Software Techniques
Greg Bronevetsky
CS717
Scope of Lecture
• No general techniques for detecting random faults
• Approach: focus on faults that show up as control flow errors– Control flow well defined problem– Legal paths through program reasonably
approximated via simple models
• If control flow errors made detectable, may detect majority of faults
• Will cover several papers in this field
CS717
Classes of Solutions
• Watchdog Processors– Separate processor watches instruction stream– Blows whistle on erroneous control flow– Pro:
• Small hit on application performance
– Con:• Needs new hardware
– Extra processor
» Though might be doable via Thread-Level Speculation
– Possibly, more bits in RAM
CS717
Classes of Solutions
• Software-only solutions– Extra instructions inserted into program– Check that jumps are correct– Pro:
• Works on existing hardware
– Con:• Potential for significant overhead• Inserted instructions can also fail
CS717
Outline
• Watchdog Processor– General overview– Concurrent Process Monitoring with No Reference
Signatures (1994)– SEIS (1995)
• Software– BSSC/ECI (1992)– CCA/ECCA (1999)– PECOS (2003)
• Control-flow Checking for Security
CS717
Watchdog Processors
• Watchdog processor acts as coprocessor• Can see all instructions loaded by CPU
– If watchdog above cache, CPU involvement required
• Signals error when sees invalid control flow
CPU
Watchdog
RAM
CS717
Block Signatures
• Each branch-free block gets a signature• Signature computed from block’s instructions• Signatures vary with scheme
– Ex: sum of the instructions in block
ld r3[0xff] r1add r1, r5, r2……mult r2, r2, r3
SB
jmp label
Block B, with signature SB
Insert SB before end of block
Watchdog sees all instructions, recomputes SB
At block end, watchdog compares computed signature
with embedded signatureError raised if not equal
Compile-time Runtime
CS717
Illegal Jump
• If illegal jump happens– watchdog will have partially
computed signature from prior block
– jump to wrong block will lead watchdog to complete signature with wrong instructions
– when watchdog sees next signature in code, will not match computed signature
Legal control flows
Illegal jump
Computed SBEmbedded SB
C
D
A
B
CS717
Error Coverage
• What if partial signature at point 1 equals partial signature at point 2?
• Then at end of block D Computed SB = Embedded SB
• Illegal jump not detected
• Problem if many blocks start out the same
Computed SB=Embedded SB
Point 1
Point 2
C
D
A
B
CS717
Error Detection Latency
• Latency - number of clock cycles before error is detected
• Blocks are typically small– 5-10 instructions
• Thus, time to fault detection fairly low• Requires many signatures to be embedded
– Memory overhead– Processor stalls while signature fetched
• Some schemes use one signature for >1 blocks– Worse detection latency
CS717
Limitations
• Approaches typically require knowledge of program control flow– Many cannot deal with programs that generate
jump destinations at runtime
• Only deal with errors manifested as control-flow errors– True for many errors– If error is originally a data error, long detection
latency
CS717
Outline
• Watchdog Processor– General overview– Concurrent Process Monitoring with No Reference
Signatures (1994)– SEIS (1995)
• Software– BSSC/ECI (1992)– CCA/ECCA (1999)– PECOS (2003)
• Control-flow Checking for Security
CS717
Upadbyaya & Ramamurthy
• Generalization of watchdog signatures approach
• Requires no signatures to be embedded into program code
• S.J. Upadbyaya and B. Ramamurthy, “Concurrent Process Monitoring with No Reference Signatures”, IEEE Transactions on Computers, 1994.
CS717
Outline of Scheme
• SIG: signature accumulated by watchdog• INST: current instruction• F: some signature generating function
– Ex: sum, XOR, etc.
• Initialize SIG to some value (such as all 0’s)• For every instruction in block,
SIG = F(SIG, INST)
CS717
Outline of Scheme
• When SIG satisfies a certain property, stop and mark instruction as check-point– Can use parity bit to mark
• At this point watchdog will notice check-point mark and will verify that its SIG also satisfies property
• Paper favorite property: m-out-of-n codeword– m 1’s out of n bits– Easy to reason about error coverage
CS717
An Single-Block Example
ld r3[0xff] r1
add r1, r5, r2……… mult r2, r2, r6
…
…
… st r6, r3[0xb2]
shl r1, r3[0xb2], 1
SIG = 0SIG = F(SIG, INST)
SIG = F(SIG, INST)
…
SIG = F(SIG, INST)m-out-of-n codeword!
mark instruction as
check-point
mult r2, r2, r6
WatchdogCompiler
SIG = 0SIG = F(SIG, INST)
SIG = F(SIG, INST)
…
SIG = F(SIG, INST)Verify that SIG is now an
m-out-of-n codeword
SIG = F(SIG, INST)
SIG = F(SIG, INST)...
SIG = F(SIG, INST)
SIG = F(SIG, INST)...
CS717
Branch Example
• Two blocks with different final signatures
• Join at block C• SIG will become legal
codeword at different points depending on whether we came from block A or B
• Must merge SIG1 and SIG2 into one
SIG1 SIG2
A B
C
CS717
Branch Example
• Idea: make sure that when we get to C, SIG is valid codeword
• But must still ensure that we correctly got to C
SIG1 SIG2
A B
C
CS717
At Compile-time
• Let TARGET = first instruction in block C• Before end of blocks A&B
SIG=F(SIG1, TARGET)EXIT_BYTE=value s.t. F(SIG, EXIT_BYTE) is a
valid codeword
TARGET
… code …
jmp label
EXIT_BYTE
• TARGET marked as a check-point
TARGET
SIG2= …SIG=F(SIG2, TARGET)
Insert EXIT_BYTE
… code …
jmp label
EXIT_BYTE
SIG1= …SIG=F(SIG1, TARGET)
Insert EXIT_BYTE
CS717
At Runtime
• At branch– Load Target instruction– Compute SIG=F(SIG2, TARGET)– Compute SIG=F(SIG, EXIT_BYTE)– SIG should now be a valid codeword
• TARGET is marked as check-point– Watchdog verifies that SIG is valid codeword
TARGET
… code …
jmp label
EXIT_BYTE
SIG2= …SIG=F(SIG2, TARGET)SIG=F(SIG2, EXIT_BYTE)
CS717
Summary of Scheme
• Scheme checks whether accumulated signature obeys given property– vs. ensuring that it matches a recorded signature
• Thus, don’t store signatures for each block– Savings in memory and fewer noops
• Need to store EXIT_BYTE– Paper suggests several mechanisms that don’t
require extra noop
• Can be generalized to any signature function and any property– Theoretical analysis given for m-out-of-n property
CS717
Performance Results
• They give some indications of what detection latency would be
• No information on – error coverage– performance overhead
CS717
Outline
• Watchdog Processor– General overview– Concurrent Process Monitoring with No Reference
Signatures (1994)– SEIS (1995)
• Software– BSSC/ECI (1992)– CCA/ECCA (1999)– PECOS (2003)
• Control-flow Checking for Security
CS717
Traditional Watchdog Techniques
• Monitor every single instruction• Not possible in machines with caches
(unless watchdog is part of processor)– External watchdog can’t see instructions fetches
from Instruction cache (I-cache)– With low I-cache miss rate, most control flow
invisible to watchdog
• In multi-tasking systems task switches will confuse watchdog
CS717
Assigned Signatures to the Rescue
• An Assigned Signature method– At various points in code, send unique signature to
watchdog– Watchdog knows legal order of signatures
• Pro:– Communication with watchdog explicit, will bypass
cache
• Con:– Since actual code invisible to watchdog, additional
required watchdog intelligence can be expensive
CS717
SEIS
• SEIS = Signature Encoded Instruction Stream• An Assigned Signature method• Aims to offer efficiency• Targets multiprocessing systems
• Documented in:I. Majzik, A. Pataricza, W. Hohl, J. Hönig and V. Sieh, “A High Speed Watchdog Processor for Multitasking Systems”, 1994.
CS717
SEIS Basic Idea
• Create control-flow graph of program– Nodes are jump-free blocks of code– Edges are possible control flows
• Assign unique label to each node s.t.– Labels have constant length– Labels of adjacent nodes have easy to detect
relationships• ex: label of each node contains IDs of valid successors
CS717
Label assignment
• Find Eulerian circuit through control-flow graph– Contains all edges exactly once– Touches nodes multiple times
• Guaranteed to exist if in all nodes in-degree = out-degree– Add phantom edges to graph to assure this
CS717
Label Assignment
• Walk circuit, assigning numbers to nodes in increasing order– When walking over phantom edge, skip a number
• Node’s label = concatenation of all assigned numbers (sublabels)– # sublabels per node = in-degree = out-degree
• If two nodes neighbors in control-flow graph, node A followed by node B– Node A label <a1, … ak>, node B label <b1, … bl>
– Then ai, bj s.t. bj = ai + 1
CS717
Example
CS717
Example
Initial Graph: in-degree out-degree
CS717
Example
Initial Graph: in-degree out-degreeAdd Phantom Edges
CS717
Example
Find Eulerian Circuit
CS717
Example
Assign Sublabels
0
1
25
,4
,6
7
11
,12
,10
,8
CS717
Example
Note: If node A succeeds node B, they’re off by 1 along some sublabel
0,6,12
1,4
2,85
7,10
11
CS717
At runtime
• In each block insert instruction to send block label to watchdog
• Watchdog watches incoming labels, stores last label seen
• If new label is neighbor of stored label along some sub-label, all OK– i.e. new label has some sub-label that is +1
relative to some sublabel of stored label
• If new label NOT neighbor of stored label, control-flow error!
CS717
Unbounded Signatures
• Method leads to efficient watchdog checks• Only problem:
– Number of successor/predecessor nodes unbounded
– Thus, label size unbounded
• Must cut out some labels without sacrificing correctness
CS717
Removing Sub-labels
• k predecessors k sublabels
• Pick one predecessor sublabel: ai
…,a1,… …,ak,…. . . . . . .
a1+1,…,ak+1
CS717
Removing Sub-labels
• k predecessors k sublabels
• Pick one predecessor sublabel: ai
• Have all predecessors use ai
• Node now needs one sublabel, not k
…,ai,… …,ai,…. . . . . . .
ai+1
CS717
Sub-label Removal Problem
• Problem: ajai but pre-predecessor still has aj-1
• Watchdog can’t tell if control-flow legal
ai+1
…,ai,…
…,aj-1,…
legal control flow?
…,aj,…
…,aj-1,…
a1+1,…,ak+1
CS717
Sub-label Removal Problem
• Paper rather cryptic on this issue• Possible solutions:
– More sublabels:• In predecessors replace single sublabel aj with sublabels
<ai, aj>• In node itself, replace, <a1, … , ak> with just ai
• Unclear if process will converge to specific label size bound
– Propagate replacement:• If predecessor node gets aj replaced with ai, in pre-
predecessor replace aj-1 with ai-1 and so on recursively• Many sublabels in program will be equal: reduced error
detection coverage
CS717
Constant Label Size
• Want label size constant, not just bounded• If label too large, use above procedure• If label too small, repeat a sublabel multiple
times– Has no effect on watchdog’s accuracy
• Paper’s target label size = 3 sublabels
CS717
Checking Procedure Calls
• Procedures have enhanced checking• At procedure start and end insert special
labels with unique procedure IDs• Watchdog maintains procedure stack
– Mirrors call stack– Ensures correct procedure returns
• Each block’s label contains ID of parent procedure– Allows for better&earlier detection of erroneous
inter-procedure jumps
CS717
Multi-Tasking Support
• Watchdog maintains several sets of last-label registers and procedure stacks– One per task– Switch between them during task switches– If more tasks than watchdog memory, caching
scheme can probably be used
• Program labels also contain task ID– Set at load time– Extra check for task scheduler and OS protection
mechanisms
CS717
Experimental Evaluation
• Program size overhead upto 30%• Execution time overhead can exceed 100%
– Particularly for programs with tight loops• one signature send for only few instructions in loop body
• Fault detection coverage: 50%• Authors implement several techniques to
reduce number of checks– Overhead brought down to 10%-15%– Fault detection coverage drops to 20%
CS717
Outline
• Watchdog Processor– General overview– Concurrent Process Monitoring with No Reference
Signatures (1994)– SEIS (1995)
• Software– BSSC/ECI (1992)– CCA/ECCA (1999)– PECOS (2003)
• Control-flow Checking for Security
CS717
Checking Control Flow in Software
• Modify program to contain instructions to check control flow
• Requires no additional hardware
• New instructions also vulnerable to faults
• Notable performance penalty– blocks are small: many additional instructions
CS717
BSSC
• BSSC = Block Signature Self Checking
• G. Miremadi, J. Karlsson, U. Gunneflo, J. Torin, “Two software techniques for on-line error detection”, FTCS 1992.
CS717
The Idea
• Assign signatures to block as you wish• Upon block entry, record signature• Upon block exit, check signature
ld r3[0xff] r1add r1, r5, r2……mult r2, r2, r3
jmp label
Block B, with signature SB
Compile-time Runtime
entry_proc() saves SB in static varchanges return ptr to next instruction
exit_proc() compares given SB to stored SB. If : YellsIf = : changes return ptr to next instruction
Insert exit_proc(SB) after block end
Insert entry_proc(SB) before block end
call entry_procSB
call exit_procSB
CS717
Optimization
• If SB= block’s starting address, can eliminate one signature
ld r3[0xff] r1add r1, r5, r2……mult r2, r2, r3
jmp label
Block B, with signature SB
Compile-time
Insert exit_proc(SB) after block end
Insert entry_proc() before block end
call entry_proc
call exit_procSB
• Address of instruction following entry_proc() call automatically pushed on stack before call
• Code planted at specific virtual address
CS717
Limitations of Technique
• BSSC ensures program leaves blocks it enters
call entry_proc(SA)
… block code …
call exit_proc(SA)
Legal Control Flow
Detected Bad Jumps
call entry_proc(SB)
… block code …
call exit_proc(SB)
call entry_proc(SC)
… block code …
call exit_proc(SC)
CS717
Limitations of Technique
• BSSC ensures program leaves blocks it enters• Cannot not detect:
– Erroneous jumps within block– Bad jumps to valid jump destinations
call entry_proc(SB)
… block code …
call exit_proc(SB)
InvisibleBad Jump
call entry_proc(SB)
… block code …
call exit_proc(SB)
call entry_proc(SB)
… block code …
call exit_proc(SB)
Legal Control Flow
call entry_proc(SB)
… block code …
call exit_proc(SB)
InvisibleBad Jump
CS717
ECI
• ECI = Error Capturing Instructions• G. Miremadi, J. Karlsson, U. Gunneflo, J.
Torin, “Two software techniques for on-line error detection”, FTCS 1992.
• Idea: fill unused memory with instructions that cause exception
• Bad jump to unused memory exception thrown
CS717
BSSC/ECI Results
BSSC + Some ECI All ECIOverhead 77%-128% ~6%Error Coverage 50%-56% 39%-50%
CS717
Outline
• Watchdog Processor– General overview– Concurrent Process Monitoring with No Reference
Signatures (1994)– SEIS (1995)
• Software– BSSC/ECI (1992)– CCA/ECCA (1999)– PECOS (2003)
• Control-flow Checking for Security
CS717
CCA/ECCA
• CCA = Control Flow Checking Using Assertions
• ECCA = Enhanced CCA
• Z. Alkhalifa, V.S.S. Nair, N. Krishnamurthy, J.A. Abraham. “Design and Evaluation of System-Level Checks for On-Line Control Flow Error Detection”, IEEE Transactions on Parallel and Distributed Systems, 1999.
CS717
CCA
• CCA a lot like BSSC but also checks branches for validity
call entry_proc(SB)
… block code …
call exit_proc(SB)
call entry_proc(SB)
… block code …
call exit_proc(SB)
Legal Control Flow
call entry_proc(SB)
… block code …
call exit_proc(SB)
Bad JumpsVisible with CCA
CS717
CCA Jump Checking
• Each basic block gets unique ID• Recorded on block entry, checked on block
exit (like BSSC)
ld r3[0xff] r1add r1, r5, r2……mult r2, r2, r3
jmp label
Block B, with signature SB
Record SB
Verify SB
CS717
CCA Jump Checking
• 2-element queue used to ensure valid flows are followed
ld r3[0xff] r1add r1, r5, r2……mult r2, r2, r3
jmp label
Block B, with signature SB
Dequeue signature, check its = to current block
Enqueue signature of following block
Enqueue Sig of next blockRecord SB
Verify SB
Dequeue Sig
CS717
Queue Example
BlockID=BFlowID=2
BlockID=CFlowID=2
Queue
1
BlockID=AFlowID=1
BlockID=DFlowID=3
CS717
Queue Example
BlockID=AFlowID=1
Queue
Enqueue 2
2
1
BlockID=DFlowID=3
BlockID=BFlowID=2
BlockID=CFlowID=2
CS717
Queue Example
BlockID=AFlowID=1
Queue
Enqueue 2
Dequeue & Check
2
1
BlockID=BFlowID=2
BlockID=CFlowID=2
BlockID=DFlowID=3
CS717
Queue Example
BlockID=AFlowID=1
Queue
Enqueue 2
Dequeue & Check
3
BlockID=DFlowID=3
BlockID=BFlowID=2
BlockID=CFlowID=2
Enqueue 3
2
CS717
Queue Example
BlockID=AFlowID=1
Queue
Enqueue 2
Dequeue & Check
3
BlockID=DFlowID=3
BlockID=BFlowID=2
BlockID=CFlowID=2
Enqueue 3
Dequeue & Check2
CS717
Queue Example
BlockID=AFlowID=1
Queue
Enqueue 2
Dequeue & Check
?
BlockID=DFlowID=3
BlockID=BFlowID=2
BlockID=CFlowID=2
Enqueue 3
Dequeue & Check3
Enqueue ?
CS717
Queue Example
BlockID=AFlowID=1
Queue
Enqueue 2
Dequeue & Check
?
BlockID=DFlowID=3
BlockID=BFlowID=2
BlockID=CFlowID=2
Enqueue 3
Dequeue & Check3
Enqueue ?
Dequeue & Check
CS717
CCA Summary
• CCA detects bad jumps – from/to insides of blocks– from end of one block to start of wrong block
• Coverage still not complete:
– Inserted code includes unchecked branches
• Major Issue: High Overhead
Enqueue SigRecord SB
… block code …
Verify SB
Dequeue & Check
InvisibleBad Jump
CS717
ECCA
• Same checks as CCA but via arithmetic• Idea:
– Each block gets unique prime ID > 2– Global variable id contains current signature– Before end of block insert:id=(nextBlockIDs + !!(id - lastBlockID))• nextBlockIDs = product of IDs of succeeding blocks• lastBlockID = ID of block we just left
– Before entering block insert:id=curBlock/(!(id%curBlock)*(id%2))• curBlock = ID of block we’re about to enter
• Claim, bad control flow will cause divide by 0
CS717
How ECCA Works
Invariant: Inside a block, id=ID of current blockid = 3Block ID = 3
id=(nextBlockIDs + !!(id - lastBlockID))
(id – lastBlockID) =0 if id = lastBlockIDNot 0 if id lastBlockID
!(id – lastBlockID) =1 if id = lastBlockID0 if id lastBlockID
!!(id – lastBlockID) =0 if id = lastBlockID1 if id lastBlockID
• If program left same block it entered, at end id = nextBlockIDs = product of ID’s of valid next blocks
• Otherwiseid = nextBlockIDs + 1 (which is even)
CS717
How ECCA Works
id = 3Block ID = 3
id=(nextBlockIDs + !!(id - lastBlockID))
id=curBlock/(!(id%curBlock)*(id%2))
Block ID = 5
Block ID = 7
Block ID = 11
Block ID = 13
id%curBlock =0 if id is multiple of curBlockNot 0 otherwise
!(id%curBlock) =1 if id is multiple of curBlock0 otherwise
id%2 =0 if id is even (error exiting last block)1 if id is odd
CS717
How ECCA Works
id=curBlock/(!(id%curBlock)*(id%2))
Block ID = 13
id%curBlock =0 if id is multiple of curBlockNot 0 otherwise
!(id%curBlock) =1 if id is multiple of curBlock0 otherwise
id%2 =1 if id is odd0 if id is even (error exiting last block)
curBlock/(!(id%curBlock)*(id%2)) =curBlock if all is welldivide by 0 exception if came from wrong block or erroneous jump into last block
Block ID = 5
Block ID = 7
Block ID = 11
CS717
ECCA Summary
• Same Checking as CCA but arithmetic• Introduces no new jumps into code• Experiments:
– Error coverages improves notably• from ~92% to ~99% or from ~45% to ~92%• predict <5% overhead if we coalesced 20 branch-free
intervals into block and had 500 blocks– high error detection latency
CS717
Outline
• Watchdog Processor– General overview– Concurrent Process Monitoring with No Reference
Signatures (1994)– SEIS (1995)
• Software– BSSC/ECI (1992)– CCA/ECCA (1999)– PECOS (2003)
• Control-flow Checking for Security
CS717
PECOS
• Checks control flow errors in software• Doesn’t need to know valid control flows at
compile time (!!)– Magic: they don’t really check bad branches
• S. Bagchi, Z. Kalbarczyk, R. Iyer, Y. Levendel. “Design and Evaluation of Preemptive Control Signature(PECOS) Checking”. Submission to IEEE Transactions on Computers, 2004.
CS717
PECOS Details
• PECOS checks for memory errors, not control-flow errors
• Memory error becomes control-flow error when faulty address used for branch
• Idea: make sure that data used for branches hasn’t changed since last write
• Will detect such errors BEFORE they manifest themselves– Error avoidance better than detection
CS717
Approach
• Right before branch, look at– Valid target address options: {X1, X2, …}
– Runtime target address: Xout
• In memory, register or instruction body
• Compute:
• If Xout not valid: divide by 0 exception
]))([(! 21 XXXX
X
outout
out
CS717
Branches with constant operands
• Branch has single valid destination: X1
jmp Xout
• Before branch load up X1
• Ensure that branch instruction’s Xout valid– via above calculation
• If instruction got corrupted: divide by 0 exception
regjmp
XX
X
out
out
)(! 1
CS717
Branches with runtime targets
• Ex: jmp register1• Find all reaching definitions of register1
• At def site, save assigned value Xout
• At branch, check value for corruption via above formula– Function returns probably done this way
regjmp
valregXreg
reg
registerupbackregtmp
valreg
)])([(!
...
//
1
1
CS717
PECOS Experiments
• Evaluation code: DHCP server– largest I’ve seen in papers I read
• Error coverage improvement 95% 98.5%• Notably fewer process aborts/hangs
– 90% 52%– Allows more graceful response to errors
• Overheads tolerable: 15%-30%
CS717
PECOS Summary
• PECOS is a memory checker– More efficient than protecting all memory– Does not protect against instruction execution
errors• Paper argues these are rare since hamming distance
between branch&non-branch opcodes is large
• Detects memory errors before they cause crash / corrupt state
CS717
Outline
• Watchdog Processor– General overview– Concurrent Process Monitoring with No Reference
Signatures (1994)– SEIS (1995)
• Software– BSSC/ECI (1992)– CCA/ECCA (1999)– PECOS (2003)
• Control-flow Checking for Security
CS717
From Fault Tolerance to Security
• Above solutions have dealt with Random Fault Adversary
• Similar techniques can apply to Human Adversary• Many attacks inject code into target application and
jump to it• Not very different from what random faults do
• Paper: Milena Milenkovic, Aleksandar Milenkovic and Emil Jovanov, “Using Instruction Block Signatures to Counter Code Injection Attacks”, WASSA 2004.
CS717
Watchdog Processor for Security
• Target Systems:– Computers with caches– Computer assumed to be non-faulty– Faults come from application
• Thus, watchdog watches for errors above cache, not below
• Assumption: if attacker forces program to execute new code, program will never return to original control flow– True for attacks of today but can be circumvented
CS717
Basic Picture
• Compute signature for each code block
• On instruction cache fetch accumulate instructions into runtime signature
• On block end, check that runtime signature matches block’s compile-time signature
CPU
Cache
Checker
Instruction Stream
CS717
Checking Signatures
• Multiple ways to store/check signatures
• SIGT – uses table inside watchdog• SIGE – embeds signatures in program code• SIGC – assigns signatures to i-cache lines
• Signatures encrypted before execution– Harder for attacker to spoof them
CS717
SIGT
• Watchdog contains table of legal block signatures
• Table populated like cache– Swap in signatures as necessary– May be initialized with popular signatures at
program start
• When code block ends, compare its signature to table contents– May need to swap in appropriate signature
CS717
SIGE
• Signatures embedded in code before each block
• At block start watchdog loads signature
• At block end, runtime signature compared to signature just loaded
CS717
SIGC
• Signatures assigned to lines in the i-cache• Embedded in program code• When i-cache line fetched, signature also
fetched• Unlike SIGE, signatures not stored in cache
– Thus, lower impact on cache miss rate
• No need for compiler
CS717
Experimental Evaluation
• Codes: SPEC CPU2000• SIGT: small 2-way caches lead to low
signature table miss rates• SIGT/SIGE: overall i-cache miss rate doesn’t
increase that much– But in one code went up by factor of 12
• SIGC: not evaluated but suggested as way to keep i-cache miss rate down
CS717
Outline
• Watchdog Processor– General overview– Concurrent Process Monitoring with No Reference
Signatures (1994)– SEIS (1995)
• Software– BSSC/ECI (1992)– CCA/ECCA (1999)– PECOS (2003)
• Control-flow Checking for Security
CS717
Control-flow checking
• Fairly general-purpose technique
• Limited error detection coverage traded off for lower overhead than replication(though overhead not always low)
• Compile-time techniques– Primitive– The most advanced in random fault detection field
CS717
Uncovered Areas
• No techniques for placing watchdog inside processor itself(that I know of)
• Different techniques evaluated using very different codes&fault injection methodologies– Need to be compared on common ground
• Limited compiler intelligence– Control flow reduced to context-free grammars or
graph reachability• In reality Turing-complete
– Existing techniques don’t use program’s own dependencies on correct control flow
CS717
Using Control-flow Dependencies
• Current techniques insert new code/signatures into program
• But program’s own instructions depend on correct program flow
• Can we detect impact of bad control flows on program’s own instructions?– Will insert far fewer additional
instructions/signatures
CS717
Summary
• Field fairly mature but hardly finished
• Techniques catch a fair share of errors but leave plenty behind– Should be used along with other techniques
• Good example of giving decent solution to a limited version of detection problem