Download - Cs 73150

Transcript
  • SPECIFICATION 1300.98 replace

    11.12.1998 1_________________________________________________________________________________________

    _________________________________________________________________________________________

    Made for NOKIA by INTERCOND ITALY Rev.2 (Modified , Intercond code)

    COAXIAL CABLE

    TYPE 11-RJD19/11R-N2 NOKIA CS Code: 73150

    CONSTRUCTION

    Inner conductor Annealed bare copper 0.310.005 mmDielectric Solid polyethylene 1.950.10 mmOuter conductor Double braid of tinned,annealed copper

    wire.coverage 87%Nominal diameter of the copperwire shall be 0.10 mm nom. 2.70 mm

    Sheath PVC , BLACK 3.550.15 mmMarking NOKIA TELECOMMUNICATION 73150

    ELECTRICAL CHARACTERISTICS at +20 C

    Characteristic impedance (IEC 1196 it.11.8) 75 3 WAttenuation nominal (IEC 1196 it.11.13)

    1.0 Mhz 2.30 dB/100 m4.0 Mhz 4.50 dB/100 m5.0 Mhz 5.00 dB/100 m

    70.0 Mhz 18.70 dB/100 mVelocity factor (IEC 1196 it. 11.9) 0.66Capacitance (IEC 1196 it. 11.3) 67 pF/mDC-resistance inner conductor(IEC 1196 it.11.1) 236 W/kmDC-resistance outer conductor 19.5 W/kmInsulation resistance (IEC 1196 it.11.2) 5 GW.km

    MECHANICAL CHARACTERISTICS

    Weight 22 kg/km Maximum pulling force 3 N

    Minimum bending radius - single bending 25 mm

    - repeated bending 75 mm Operating temperature range -40...+70C

    Minimum installation temperature -20C

    CONDITIONS OF DELIVERY

    The cable lenght;nominal 1000 mThe cable shall be well wound on spoolwith the ends accessible for testing;Diameter spool 400 mmTag identification:

    manufacturer name

  • SPECIFICATION 1300.98 replace

    11.12.1998 2_________________________________________________________________________________________

    _________________________________________________________________________________________

    Made for NOKIA by INTERCOND ITALY Rev.2 (Modified , Intercond code)

    order Nrtype cablecode cablelenght cable