SPECIFICATION 1300.98 replace
11.12.1998 1_________________________________________________________________________________________
_________________________________________________________________________________________
Made for NOKIA by INTERCOND ITALY Rev.2 (Modified , Intercond code)
COAXIAL CABLE
TYPE 11-RJD19/11R-N2 NOKIA CS Code: 73150
CONSTRUCTION
Inner conductor Annealed bare copper 0.310.005 mmDielectric Solid polyethylene 1.950.10 mmOuter conductor Double braid of tinned,annealed copper
wire.coverage 87%Nominal diameter of the copperwire shall be 0.10 mm nom. 2.70 mm
Sheath PVC , BLACK 3.550.15 mmMarking NOKIA TELECOMMUNICATION 73150
ELECTRICAL CHARACTERISTICS at +20 C
Characteristic impedance (IEC 1196 it.11.8) 75 3 WAttenuation nominal (IEC 1196 it.11.13)
1.0 Mhz 2.30 dB/100 m4.0 Mhz 4.50 dB/100 m5.0 Mhz 5.00 dB/100 m
70.0 Mhz 18.70 dB/100 mVelocity factor (IEC 1196 it. 11.9) 0.66Capacitance (IEC 1196 it. 11.3) 67 pF/mDC-resistance inner conductor(IEC 1196 it.11.1) 236 W/kmDC-resistance outer conductor 19.5 W/kmInsulation resistance (IEC 1196 it.11.2) 5 GW.km
MECHANICAL CHARACTERISTICS
Weight 22 kg/km Maximum pulling force 3 N
Minimum bending radius - single bending 25 mm
- repeated bending 75 mm Operating temperature range -40...+70C
Minimum installation temperature -20C
CONDITIONS OF DELIVERY
The cable lenght;nominal 1000 mThe cable shall be well wound on spoolwith the ends accessible for testing;Diameter spool 400 mmTag identification:
manufacturer name
SPECIFICATION 1300.98 replace
11.12.1998 2_________________________________________________________________________________________
_________________________________________________________________________________________
Made for NOKIA by INTERCOND ITALY Rev.2 (Modified , Intercond code)
order Nrtype cablecode cablelenght cable
Top Related