Download - Chevilles chimiques EN V2019...Hollow concrete blocks B 40 (fb ≥ 6.0 N/mm²) Vrec 1,80 Hollow clay bricks OPTIBRIC PV 3+ (fb ≥ 9.0 N/mm²) Vrec 1,30 Clay masonries POROTHERM GF

Transcript
Page 1: Chevilles chimiques EN V2019...Hollow concrete blocks B 40 (fb ≥ 6.0 N/mm²) Vrec 1,80 Hollow clay bricks OPTIBRIC PV 3+ (fb ≥ 9.0 N/mm²) Vrec 1,30 Clay masonries POROTHERM GF

139

Anchor sizeBase material

EASYMIXM8/M10

Hollow concrete blocks B 40 (fb ≥ 6.0 N/mm²)

Nrec 0,65

Hollow clay bricks OPTIBRIC PV 3+ (fb ≥ 9.0 N/mm²)

Nrec 0,40

Clay masonries POROTHERM GF R20 Th+ (fb ≥ 10.0 N/mm²)

Nrec 0,40

Clay masonries POROTHERM R37 (fb ≥ 8.0 N/mm²)

Nrec 0,40

Anchor sizeBase material

EASYMIXM8/M10

Hollow concrete blocks B 40 (fb ≥ 6.0 N/mm²)

Vrec 1,80

Hollow clay bricks OPTIBRIC PV 3+ (fb ≥ 9.0 N/mm²)

Vrec 1,30

Clay masonries POROTHERM GF R20 Th+ (fb ≥ 10.0 N/mm²)

Vrec 1,30

Clay masonries POROTHERM R37 (fb ≥ 8.0 N/mm²)

Vrec 1,30

EASYMIX1/1

Hybrid anchor, for fi xing in concrete andhollow and solid masonries

APPLICATION

M8X140-Ø16 Wall-mounted boiler Hand rails Bracketing

M10X140-Ø16 Water heaters Electrical switchboards Washroom

M10X140-Ø16 EXT. Air conditioning brackets Wall lights Signs

Technical data

180468080000010

Anchor size EASYMIX MALE STUD Drilling Ø

Drilling depth

Max. thick.part to be fixed

Max.tighten torque

Code

ExternalØ

Total length

ThreadØ

Total length

Thread length

Masonry Concrete(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (Nm) (Nm) Blister Boxdnom LS d L Lf dO hO tfix Tinst Tinst x4 x12

M8X140-Ø16 8 060230 060228

M10X140-Ø16 16 135 10 180 40 16 150 30 3 10 060231 060229

M10X140-Ø16 EXT. 10 060232 -

Setting timee

Temperature Curing time

25°C 45 min

15°C 60 min

5°C 90 min

Recommended loads (Nrec, Vrec) in masonries in kN

SHEARTENSILE

MATERIAL

Pre-dosed system : vinylester resin

Male stud: zinc coated steel 5.8(5 μm).

Outdoor version EXT: zinc flake coating (5 μm).

Tinst

h0tfix

Ls

d0

dnom

L

T25

Lfd

x2

x2

x2

TechnicalAssessmentSOCOTEC

Recommended loads (Nrec,Vrec) in concrete ≥C20/25 in kN

SHEARTENSILE

Anchor size EASYMIXM8/M10

Nrec 2,5

F = 1,4 ; Mc = 2,16

Anchor size EASYMIXM8/M10

Minimum spacing distances (mm)

smin 160

cmin 80

Anchor size EASYMIXM8/M10

Vrec 2,5

F = 1,4 ; Mc = 2,16

INSTALLATION

5

Nu,mNrec =5

Vu,mVrec =

M F

NRk *Nrec = M F

VRk *Vrec =

MAJ 09/19