VESSEL : TB TYTYAN KARIMATA 02LOCATION : KELANIS
PIC : 2 MEI 2015
NO. ITEM CHECK POINTS Runninghours REMAKS
Operate satisfactorily. Yes No
Safety devices function properly. Yes No Emergency engine stop tidakberfungsi
Remote control function properly. Yes No
Check the alarm lamp operation Yes No
Water level at expansion tank Yes No
Check condition and level the Engine Oil 50 Yes No 2 Mei 2015
The oil filter 250 Yes No
The fuel filter 250 Yes No
Condition of the V- Belt Yes No
Damper vibration Yes No
Color of exhaust smoke 2000 Yes No Putih tipis
Sea water discharging volume Yes No Good order
Tightening torque of bolts 2000 Yes No
Operate satisfactorily. Yes No
Oil level ( between " Min " and " Max" )and condition of The Oil Yes
No
Inspect leakage of oil and water 100 Yes No
Clean the parts and pipes 10000 Yes No Sebagian ada yang dibalutdengan karet ban
Abnormal running 500 Yes No
Abnormal operating noises 500 Yes No
Tightening torque of bolts Yes No
Operate satisfactorily. Yes No
Safety devices function properly. Yes No Emergency engine stop tidakberfungsi
Remote control function properly. Yes No
Check the alarm lamp operation Yes No
Water level at expansion tank Yes No
Check condition and level the Engine Oil 50 Yes No 2 Mei 2015
The oil filter 250 Yes No
The fuel filter 250 Yes No
Condition of the V- Belt Yes No
Damper vibration Yes No
Color of exhaust smoke 2000 Yes No Putih tebal
Sea water discharging volume Yes No
Tightening torque of bolts 2000 Yes No
Operate satisfactorily. Yes No
Oil level ( between " Min " and " Max" )and condition of The Oil Yes
No
Inspect leakage of oil and water 100 Yes No
Clean the parts and pipes 10000 Yes No Sebagian ada yang dibalutdengan karet ban
PMS CHECKLIST
2
1
GEARBOXSTARBOARD
(TWIN DISC MG516)
MAIN ENGINESTARBOARDSIDE
(CATERPILLAR3412)
SATISFACTORY
MAIN ENGINEPORTSIDE
(CATERPILLAR3412)
GEARBOX PORT(TWIN DISC MG
516)
NO. ITEM CHECK POINTS Runninghours REMAKS
1
SATISFACTORY
MAIN ENGINEPORTSIDE
(CATERPILLAR3412)
Abnormal running 500 Yes No
Abnormal operating noises 500 Yes No
Tightening torque of bolts Yes No
Operate satisfactorily. Yes No
Safety devices function properly. Yes No
Water level at Expansion Tank 50 Yes No
Condition of the V - Belt Yes No
Condition The Oil and Level Oil 50 Yes No
Lubricating Oil Filter 250 Yes No
Color of exhaust smoke Yes No
Sea water discharging volume Yes No
Air Filter Yes No NA
Operate satisfactorily. Yes No Good order
Abnormal vibration Yes No
Output voltage Yes No
Operate satisfactorily. Yes No
Safety devices function properly. Yes No
Water level at Expansion Tank 50 Yes No
Condition of the V - Belt Yes No
Condition The Oil and Level Oil 50 Yes No
Lubricating Oil Filter 250 Yes No
Color of exhaust smoke Yes No
Sea water discharging volume Yes No
Air Filter Yes No NA
Operate satisfactorily. Yes No Good order
Abnormal vibration Yes No
Output voltage Yes No
Operate satisfactorily. Yes No Good order
Check wire terminal and tightness motordriven fire pump Yes
No
Clean fan, impeller and protective guardventilation passage motor driven main firepump
Yes No
Cleaning housing driven fire pump Yes No
Abnormal noise and vibrate Yes No
check all line main fire system fromleaking Yes
No
open and close all main fire valve, ensureall valve easy and ready for operate, addgrease at valve stem and change glandpacking if necessary
Yes No
Operate satisfactorily. Yes No Good order
Abnormal noise and vibrate Yes No
leakage from the pump casing Yes No
Greasing Yes NoFIRE PUMP6
4
GENERATORENGINES
STARBOARDSIDE(MITSUBISHI 4D33)
ALTERNATOR(NSR STC.30)
3
5
2
FIRE SISTEM
ALTERNATOR(NSR STC.30)
GEARBOXSTARBOARD
(TWIN DISC MG516)
GENERATORENGINES
PORTSIDE(MITSUBISHI 4D33)
NO. ITEM CHECK POINTS Runninghours REMAKS
1
SATISFACTORY
MAIN ENGINEPORTSIDE
(CATERPILLAR3412)
All valves operate satisfactorily. Yes No
Piping in good order. Yes No
Operate satisfactorily. Yes NoGood order (setiap haridifungsikan untuk mencucikapal)
leakage from the pump casing Yes No
All valves operate satisfactorily. Yes No
Hose in good order. Yes No
Ballast pump operate satisfactorily. Yes No
No heavy corrosion and leakage. Yes No
All valves operate satisfactorily. Yes No
Piping in good order. Yes No
Bilge & GS Pump operate satisfactorily. Yes No
No heavy corrosion and leakage. Yes No
All valves operate satisfactorily. Yes No
Piping in good order. Yes No
Sea water cooling Pump operatesatisfactorily. Yes
No
No heavy corrosion and leakage. Yes No
All valves operate satisfactorily. Yes No
Piping in good order. Yes No Sebagian ada yang dibalutdengan karet ban
Fuel oil Pump operate satisfactorily. Yes No
No heavy corrosion and leakage. Yes No
All valves operate satisfactorily. Yes No
Piping in good order. Yes No
Emergency stop operating satisfactorily Yes No
Operate satisfactorily. Yes No
Remote and control function properly. Yes No
Meters and gauges in good order. Yes No
No heavy corrosion and leakage. Yes No
All valves operate satisfactorily. Yes No
14 BLOWER E/R Operate satisfactorily. Yes No Sebelah kiri tidak berfungsi
15 EMERGENCYSTEERING Operate satisfactorily. YesNo
16 CONTROLCONSOL Operate satisfactorily. YesNo
17 CLEANLINESS ofE/R Must be clean without rubbish or waste oil. YesNo
Operate satisfactorily. Yes No
All valves operate satisfactorily. Yes No
Sulkarnaim Dede MulyanaChief Engineers Technical Superintendent
Date : 02 Mei 2015 Date : 02 Mei 2015
8
10
11
12HYDRAULIC
POWER PACK ANDCONTROL
9
FIRE PUMP6
18
13 PIPING
QUICK CLOSINGVALVE
FUEL OIL SYSTEM
EMERGENCY FIREPUMP7
BALLAST SYSTEMPORT & STBD
BILGE & GSSYSTEM
SEA WATERCOOLING SYSTEM