Chapter 13

Basic Relay Instructions

Page 2: Chapter 13

Objectives (1 of 2)

• Describe the function of the normally open, or examine if closed, instruction.

• Describe the function of the normally closed, or examine if open, instruction.

• Explain the function of one-shot instruction.

Page 3: Chapter 13

Objectives (2 of 2)

• Explain the function and programming of the latch and unlatch instructions.

• Explain input and output instruction formatting for the SLC 500 and MicroLogix PLCs.

• Given an address, identify the input or output point on an SLC 500 fixed or modular PLC and a MicroLogix 1000 PLC.

Page 4: Chapter 13

PLC Instructions

• Each PLC manufacturer has its own vocabulary of instructions called the PLC instruction set.

• Even though different PLCs have different instruction sets, there are basic instructions shared by all PLCs.

Page 5: Chapter 13

Bit or Relay Instructions

• Contacts and coils are the basic symbols found on a ladder program.

• Normally open and normally closed instructions are programmed to represent input conditions.

• Contacts and coils are referred to as relay instructions.

Page 6: Chapter 13

Overview of Bit Instructions

Page 7: Chapter 13

SLC 500 XIC Instruction

• SLC 500 normally open instruction is called the XIC or examine if closed instruction.

• XIC instruction directs the processor to test for an on condition from the referenced address bit.

Page 8: Chapter 13

XIC Instruction Interaction

Page 9: Chapter 13

XIC Input Instruction

Page 10: Chapter 13

SLC 500 XIO Instruction (1 of 3)

• SLC 500 normally closed instruction is called the XIO or examine if open instruction.

• XIO instruction directs the processor to test for an off condition from the referenced address bit.

Page 11: Chapter 13

SLC 500 XIO Instruction (2 of 3)

• The XIO instruction is normally closed, representing a 0 in the input status table.

• Finding a 0 in the status file referencing the instruction address means the device controlling the bit address is in the off condition.

Page 12: Chapter 13

SLC 500 XIO Instruction (3 of 3)

• A normally closed instruction evaluated as closed is a true instruction.

• Finding the normally closed instruction true, the instruction will continue to provide continuity through the instruction on the rung.

Page 13: Chapter 13

Instruction Controlling an Output Instruction

Page 14: Chapter 13

Physical Input Conditions and the Normally Closed XIO Instruction

Page 15: Chapter 13

SLC 500 Output Instruction (1 of 2)

• It is typically represented as an output coil.

• SLC 500 refers to an output enable or OTE instruction.

• Every rung must have an output instruction.

• Multiple outputs must be programmed in parallel.

Page 16: Chapter 13

SLC 500 Output Instruction (2 of 2)

• Output instruction is always the last instruction before the right power rail.

• Output instruction represents the action to be taken when the solved input logic results in a logically true or false rung.

Page 17: Chapter 13

Ladder Rung Containing XIC and OTE Instructions

Page 18: Chapter 13

Bit Instruction Addressing

• Each instruction on a ladder rung must have an address that associates with the field device and data table the instruction is examining.– Typical XIC address is I:1/0.– Typical OTE address is O:2/1.

Page 19: Chapter 13

Basic SLC 500 Input or Output Addressing Format

Page 20: Chapter 13

I:1/0 Breakdown (1 of 2)

• I = This is an input instruction. – Input address data stored in the input status

file

• : = element delimiter – Separate file type and file number

• 1 = Identifies the chassis slot in which the address’ module resides

Page 21: Chapter 13

I:1/0 Breakdown (2 of 2)

• / = bit delimiter– Separates the input bit slot reference from the

input bit reference

• 1 = screw terminal number of this input reference from the input module residing in chassis slot 1

Page 22: Chapter 13

Slot Identification in an SLC 500 Chassis (1 of 2)

• To accurately identify a specific input point among multiple input modules, each slot in a modular chassis is assigned a slot number.

• Power supply mounts on the left side of the chassis.

• First slot next to power supply is reserved for the processor.

Page 23: Chapter 13

Slot Identification in an SLC 500 Chassis (2 of 2)

• Processor always goes in the first slot, which is identified as slot 0.

• Slots are numbered in decimal numbers from left to right: slot 0, 1, 2, 3, 4, 5, 6.

• Four chassis are available.– 4-, 7-, 10-, and 13-slot chassis– Total 3 chassis 30 local I/O slots per PLC

Page 24: Chapter 13

Seven-Slot SLC 500 Chassis Slot Identification

Page 25: Chapter 13

The One-Shot Rising Instruction

• One-shot rising instruction (OSR) is an input instruction that allows an event to occur only once.

• OSR instruction fires on the rising edge (off-to-on transition) of the input pulse.

• It will not fire again until input transitions to off and then on.

Page 26: Chapter 13

SLC 500 Family One-Shot Rising Ladder Rung

Page 27: Chapter 13

Leading-Edge Versus Trailing-Edge One-Shot Timing Diagram

Page 28: Chapter 13

Internal Bit Controlling a One-Shot Instruction

Page 29: Chapter 13

Output Latch and Unlatch Instruction (1 of 2)

• An output latch (OTL) instruction is an output instruction used to maintain, or latch, an output on even if the status of the input logic changes.

• The output unlatch (OUT) instruction is used to unlatch the latched output.

Page 30: Chapter 13

Output Latch and Unlatch Instruction (2 of 2)

• OTL and OTU instructions are typically used in pairs.

• OTU is used by itself to unlatch status bits set by the processor.

• OTL and OUT are retentive instructions.

Page 31: Chapter 13

Retentive Instructions (1 of 2)

• Two types of instructions– Nonretentive– Retentive

• Non-retentive instructions do not retain their logical state through a rung true-to-false transition or power interruption.

• Retentive instruction retains its logical state through a rung transition or a power flow interruption.

Page 32: Chapter 13

Retentive Instructions (2 of 2)

• Retentive must have battery backup to retain state through power interruption.

• OTE instruction is non-retentive.

• OTL and OUT instructions are retentive.

Page 33: Chapter 13

Latching and Unlatching Ladder Logic

Page 34: Chapter 13

Latching Instruction Programmed Before the Unlatch Instruction

Page 35: Chapter 13

Internal Bit B3:0/0 Used as an Output

Page 36: Chapter 13

Each Bit File Element Consists of One 16-bit Word

Page 37: Chapter 13

Bit File Addressing (1 of 2)

• B = a bit instruction– Bit file address data is stored in the binary or

bit file, B3.

• 3 = identifies this as file 3

• : = element delimiter – Separate file type and file number

• 1 = identifies the element number

Page 38: Chapter 13

Bit File Addressing (2 of 2)

• / = bit delimiter– Separates the file designator from the bit

number

• 1 = bit number of this reference from bit file element 1

Page 39: Chapter 13

User-Defined Bit Files

• If your processor supports expanding data files and has enough memory, any data file over file 8 up to 255 can be created as a user-defined bit file.

• Each user-defined file can have up to 256 elements.– Sample addresses: B10:4/8 or B65:29/12