Aerogel Composite Improves U-Value of Barrel Vault Ceiling
Floor to ceiling height conserved in museum
C A S E S T U D Y
Location: Imperial War Museum, London Fabrication Partner: The Proctor Group
Provide ceiling insulation for Barrel Vault area of Imperial War Museum in London. This area was overheating in the summer and very cold in the winter.Improve u-value to below 0.2W/m2K, while not reducing the floor to ceiling height.
The Proctor Group installed 20 mm of its Spacetherm blanket insulation on the ceiling. Spacetherm is a composite of Spaceloft® insulation and fibrous matting. It has a thermal conductivity of only 0.013W/mk, enabling high thermal performance in a thin, flexible blanket.
Spacetherm achieved a u-value of 0.18W/m2K, which exceeded the specification.Spacetherm’s 20 mm thickness barely reduced the floor to ceiling height.
•
•
••
••
CHALLENGES
DETAILS
SOLUTIONS
BENEFITS
Aspen Aerogels, Inc.30 Forbes Road, Building BNorthborough, MA 01532USA
Aspen Aerogels and Spaceloft are registered trademarks of Aspen Aerogels, Inc.© 2011 Aspen Aerogels, Inc.
REV 1.0
Phone:Fax:E-Mail:Web:
Spaceloft - High Performance Insulation for Building Envelopes